Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An Evaluation of Energy Storage Cost and Performance Characteristics

The energy storage industry continues to expand globally as costs continue to fall and opportunities in consumer, transportation and grid applications are defined. As the rapid evolution of the industry continues, it has become increasingly important to understand how varying technologies compare in terms of cost and performance. This paper defines and evaluates cost and performance parameters of six battery energy storage technologies (BESS) - lithium-ion batteries, lead-acid batteries, redox flow batteries, sodium-sulfur batteries, sodium metal halide batteries, and zinc-hybrid cathode batteries - four non-BESS storage technologies - pumped storage hydropower, flywheels, compressed air energy storage, and ultracapacitors - and combustion turbines. Cost and performance information was compiled based on an extensive literature review, conversations with vendors and stakeholders, and costs of systems procured at sites across the United States. Detailed cost and performance estimates are presented for 2018 and projected out to 2025. Annualized costs were also calculated for each technology.

Mongird, Kendall↗

High-performance mass storage system for workstations

Reduced Instruction Set Computer (RISC) workstations and Personnel Computers (PC) are very popular tools for office automation, command and control, scientific analysis, database management, and many other applications. However, when using Input/Output (I/O) intensive applications, the RISC workstations and PC's are often overburdened with the tasks of collecting, staging, storing, and distributing data. Also, by using standard high-performance peripherals and storage devices, the I/O function can still be a common bottleneck process. Therefore, the high-performance mass storage system, developed by Loral AeroSys' Independent Research and Development (IR&D) engineers, can offload a RISC workstation of I/O related functions and provide high-performance I/O functions and external interfaces. The high-performance mass storage system has the capabilities to ingest high-speed real-time data, perform signal or image processing, and stage, archive, and distribute the data. This mass storage system uses a hierarchical storage structure, thus reducing the total data storage cost, while maintaining high-I/O performance. The high-performance mass storage system is a network of low-cost parallel processors and storage devices. The nodes in the network have special I/O functions such as: SCSI controller, Ethernet controller, gateway controller, RS232 controller, IEEE488 controller, and digital/analog converter. The nodes are interconnected through high-speed direct memory access links to form a network. The topology of the network is easily reconfigurable to maximize system throughput for various applications. This high-performance mass storage system takes advantage of a 'busless' architecture for maximum expandability. The mass storage system consists of magnetic disks, a WORM optical disk jukebox, and an 8mm helical scan tape to form a hierarchical storage structure. Commonly used files are kept in the magnetic disk for fast retrieval. The optical disks are used as archive media, and the tapes are used as backup media. The storage system is managed by the IEEE mass storage reference model-based UniTree software package. UniTree software will keep track of all files in the system, will automatically migrate the lesser used files to archive media, and will stage the files when needed by the system. The user can access the files without knowledge of their physical location. The high-performance mass storage system developed by Loral AeroSys will significantly boost the system I/O performance and reduce the overall data storage cost. This storage system provides a highly flexible and cost-effective architecture for a variety of applications (e.g., realtime data acquisition with a signal and image processing requirement, long-term data archiving and distribution, and image analysis and enhancement).

Chiang, T.↗

Integrated heat pipe-thermal storage system performance evaluation

An integrated thermal energy storage (TES) system, developed as a part of an organic Rankine cycle solar dynamic power system is described, and the results of the performance verification tests of this TES system are presented. The integrated system consists of potassium heat-pipe elements that incorporate TES canisters within the vapor space, along with an organic fluid heater tube used as the condenser region of the heat pipe. The heat pipe assembly was operated through the range of design conditions from the nominal design input of 4.8 kW to a maximum of 5.7 kW. The performance verification tests show that the system meets the functional requirements of absorbing the solar energy reflected by the concentrator, transporting the energy to the organic Rankine heater, providing thermal storage for the eclipse phase, and allowing uniform discharge from the thermal storage to the heater.

Keddy, E.↗

Pathways to High-Performance Salt Hydrate Thermochemical Energy Storage Materials and Systems

Thermochemical materials (TCMs) based on salt hydrates are promising for thermal energy storage as they combine high energy densities with low reaction temperatures. However, their adoption is hindered by poor structural integrity and degradation under hygrothermal cycling. Storage performance is governed not only by the chemical reaction, but also by the coupled thermo-chemo-mechanical behavior that evolves with cycling. Understanding and controlling this coupling across length scales (material-to-reactor) is necessary to improve TCM stability and lifetime. In this perspective, we discuss the shortcomings of current characterization approaches and emphasize the need for measuring transport properties and structural transformations using in situ techniques that capture the dynamic evolution of these materials. We also outline opportunities for multiscale modeling frameworks that link thermodynamics and mechanics, enabling predictive evaluation of composite architectures designed for cycling stability. We conclude by identifying research questions that must be addressed to transform TCMs into viable energy storage technologies.

Composites↗

SIRIUS: Science-Driven Data Management for Multi-Tiered Storage

The data sets being generated by large applications on very large-scale systems are increasing in both size and complexity. At the same time, there are new ways available to store and access these data sets. The goal in this project is to develop software that applications can use to make use of new and existing storage technologies in more sophisticated ways. One challenge in scientific data management is handling ‘hot’ vs ‘cold’ data. Data that is hot is data that is needed (or will be needed soon) in order for the program to continue progressing, while cold data is either output (and so will not be need further during the life of the program) or will not be needed until significantly later in the program’s run. Hot data should be stored in a way that allows fast access. On most systems, economic factors lead to an inverse relationship between storage performance and storage capacity and so fast access storage is limited. This makes it important to correctly place hot and cold data and avoid cold data unnecessarily consuming precious resources. In this reporting period, we addressed this challenge in various ways and at various levels. Data management frameworks offer only limited control to applications in how data is stored. We have added software capabilities for seamlessly moving data between layers of the storage technology using promote and demote functions to existing software frameworks. This gives direct control to applications in deciding what priority data receives. Additionally, we integrated different storage layer management frameworks in order to allow data to be exchanged and moved between storage layers in a consistent way across the application. Further, applications are not always able to directly decide what storage level makes sense for a given piece of data without an understanding of the underlying storage technologies. Data storage frameworks are often positioned to make these sorts of decisions in service of the application. We have added machine-learning based capabilities to data staging frameworks in order to make intelligent decisions about where data should be stored given learning about patterns in previous usage of similar data.

97 MATHEMATICS AND COMPUTING↗

Use of HSM with Relational Databases

Hierarchical storage management (HSM) systems have evolved to become a critical component of large information storage operations. They are built on the concept of using a hierarchy of storage technologies to provide a balance in performance and cost. In general, they migrate data from expensive high performance storage to inexpensive low performance storage based on frequency of use. The predominant usage characteristic is that frequency of use is reduced with age and in most cases quite rapidly. The result is that HSM provides an economical means for managing and storing massive volumes of data. Inherent in HSM systems is system managed storage, where the system performs most of the work with minimum operations personnel involvement. This automation is generally extended to include: backup and recovery, data duplexing to provide high availability, and catastrophic recovery through use of off-site storage.

Breeden, Randall↗

Giant energy-storage density with ultrahigh efficiency in lead-free relaxors via high-entropy design

Next-generation advanced high/pulsed power capacitors rely heavily on dielectric ceramics with high energy storage performance. However, thus far, the huge challenge of realizing ultrahigh recoverable energy storage density (W rec ) accompanied by ultrahigh efficiency (η) still existed and has become a key bottleneck restricting the development of dielectric materials in cutting-edge energy storage applications. Here, we propose a high-entropy strategy to design “local polymorphic distortion” including rhombohedral-orthorhombic-tetragonal-cubic multiphase nanoclusters and random oxygen octahedral tilt, resulting in ultrasmall polar nanoregions, an enhanced breakdown electric field, and delayed polarization saturation. A giant W rec ~10.06 Jcm –3 is realized in lead-free relaxor ferroelectrics, especially with an ultrahigh η ~90.8%, showing breakthrough progress in the comprehensive energy storage performance for lead-free bulk ceramics. This work opens up an effective avenue to design dielectric materials with ultrahigh comprehensive energy storage performance to meet the demanding requirements of advanced energy storage applications.

25 ENERGY STORAGE↗

Building Battery Energy Storage System Performance Data into an Economic Assessment

Economic assessments of battery energy storage systems (BESSs) rely on optimal dispatch methods to capture temporal interdependency of BESS operations and coupling among different grid applications. Many existing BESS economic assessment studies are based on a simplified first-order scalar model using BESS nameplate numbers. Such a method cannot accurately capture varying capabilities and nonlinear dynamics of a BESS, leading to inaccurate assessment results. This paper presents a practical implementation of performance data into the economic assessment of the BESSs recently developed within the Snohomish Public Utility District system in Washington State. Extensive testing conducted over multiple seasons is used to assess the technical performance and develop high-fidelity models of the BESSs. A dynamic programming algorithm is proposed to optimally dispatch the BESSs and assess the potential benefits from stacked value streams. The proposed method can be adapted for the economic assessment of other BESSs with different applications.

Wu, Di↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Eighth Goddard Conference on Mass Storage Systems and Technologies in Cooperation with the Seventeenth IEEE Symposium on Mass Storage Systems

This document contains copies of those technical papers received in time for publication prior to the Eighth Goddard Conference on Mass Storage Systems and Technologies which is being held in cooperation with the Seventeenth IEEE Symposium on Mass Storage Systems at the University of Maryland University College Inn and Conference Center March 27-30, 2000. As one of an ongoing series, this Conference continues to provide a forum for discussion of issues relevant to the management of large volumes of data. The Conference encourages all interested organizations to discuss long term mass storage requirements and experiences in fielding solutions. Emphasis is on current and future practical solutions addressing issues in data management, storage systems and media, data acquisition, long term retention of data, and data distribution. This year's discussion topics include architecture, future of current technology, new technology with a special emphasis on holographic storage, performance, standards, site reports, vendor solutions. Tutorials will be available on stability of optical media, disk subsystem performance evaluation, I/O and storage tuning, functionality and performance evaluation of file systems for storage area networks.

Kobler, Benjamin↗

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

Fundamentals of hydrogen storage in nanoporous materials

Abstract Physisorption of hydrogen in nanoporous materials offers an efficient and competitive alternative for hydrogen storage. At low temperatures (e.g. 77 K) and moderate pressures (below 100 bar) molecular H 2 adsorbs reversibly, with very fast kinetics, at high density on the inner surfaces of materials such as zeolites, activated carbons and metal–organic frameworks (MOFs). This review, by experts of Task 40 ‘Energy Storage and Conversion based on Hydrogen’ of the Hydrogen Technology Collaboration Programme of the International Energy Agency, covers the fundamentals of H 2 adsorption in nanoporous materials and assessment of their storage performance. The discussion includes recent work on H 2 adsorption at both low temperature and high pressure, new findings on the assessment of the hydrogen storage performance of materials, the correlation of volumetric and gravimetric H 2 storage capacities, usable capacity, and optimum operating temperature. The application of neutron scattering as an ideal tool for characterising H 2 adsorption is summarised and state-of-the-art computational methods, such as machine learning, are considered for the discovery of new MOFs for H 2 storage applications, as well as the modelling of flexible porous networks for optimised H 2 delivery. The discussion focuses moreover on additional important issues, such as sustainable materials synthesis and improved reproducibility of experimental H 2 adsorption isotherm data by interlaboratory exercises and reference materials.

08 HYDROGEN↗

Adsorption of Natural Gas in Metal–Organic Frameworks: Selectivity, Cyclability, and Comparison to Methane Adsorption

Evaluation of metal–organic frameworks (MOFs) for adsorbed natural gas (ANG) technology employs pure methane as a surrogate for natural gas (NG). This approximation is problematic, as it ignores the impact of other heavier hydrocarbons present in NG, such as ethane and propane, which generally have more favorable adsorption interactions with MOFs compared to methane. Herein, using quantitative Raman spectroscopic analysis and Monte Carlo calculations, we demonstrate the adsorption selectivity of high-performing MOFs, such as MOF-5, MOF-177, and SNU-70, for a methane and ethane mixture (95:5) that mimics the composition of NG. The impact of selectivity on the storage and deliverable capacities of these adsorbents during successive cycles of adsorption and desorption, simulating the filling and emptying of an ANG tank, is also demonstrated. Finally, the study reveals a gradual reduction in the storage performance of MOFs, particularly with smaller pore volumes, due to ethane accumulation over long-term cycling, until a steady state is reached with substantially degraded storage performance.

03 NATURAL GAS↗

Alkali metal/halide thermal energy storage systems performance evaluation

A pseudoheat-pipe heat transfer mechanism has been demonstrated effective in terms of both total heat removal efficiency and rate, on the one hand, and system isothermal characteristics, on the other, for solar thermal energy storage systems of the kind being contemplated for spacecraft. The selection of appropriate salt and alkali metal substances for the system renders it applicable to a wide temperature range. The rapid heat transfer rate obtainable makes possible the placing of the thermal energy storage system around the solar receiver canister, and the immersing of heat transfer fluid tubes in the phase change salt to obtain an isothermal heat source.

Phillips, W. M.↗

Probabilistic Modeling of Climate Change Impacts on Renewable Energy and Storage Requirements for NM's Energy Transition Act (SAND Report)

This report provides a study of the potential impacts of climate change on intermittent renewable energy resources, battery storage, and resource adequacy in Public Service Company of New Mexico’s Integrated Resource Plan for 2020 – 2040. Climate change models and available data were first evaluated to determine uncertainty and potential changes in solar irradiance, temperature, and wind speed in NM in the coming decades. These changes were then implemented in solar and wind energy models to determine impacts on renewable energy resources in NM. Results for the extreme climate-change scenario show that the projected wind power may decrease by ~13% due to projected decreases in wind speed. Projected solar power may decrease by ~4% due to decreases in irradiance and increases in temperature in NM. Uncertainty in these climate-induced changes in wind and solar resources was accommodated in probabilistic models assuming uniform distributions in the annual reductions in solar and wind resources. Uncertainty in battery storage performance was also evaluated based on increased temperature, capacity fade, and degradation in round-trip efficiency. The hourly energy balance was determined throughout the year given uncertainties in the renewable energy resources and energy storage. The loss of load expectation (LOLE) was evaluated for the 2040 No New Combustion portfolio and found to increase from 0 days/year to a median value of ~2 days/year due to potential reductions in renewable energy resources and battery storage performance and capacity. A rank-regression analyses revealed that battery round-trip efficiency was the most significant parameter that impacted LOLE, followed by solar resource, wind resource, and battery fade. An increase in battery storage capacity to ~25,000 – 30,000 MWh from a baseline value of ~14,000 MWh was required to reduce the median value of LOLE to ~0.2 days/year with consideration of potential climate impacts and battery degradation.

54 ENVIRONMENTAL SCIENCES↗

Recent Progress on Cerium Oxide‐Based Nanostructures for Energy and Environmental Applications

Cerium oxide (CeO 2 ) photo/electrocatalysts for energy storage and environmental applications have attracted considerable interest because of stable crystal structure, low toxicity/cost, superior chemical stability, stable redox (Ce 3+ /Ce 4+ ) pairs, abundant oxygen defects, and capablility for intense interaction with other materials. However, the wide bandgap and poor conductivity lower the CeO 2 photo/electrocatalytic and energy storage performances. To overcome these limitations, various modification strategies (tuning morphology, doping or loading of metal nanoparticles, and heterostructures) have been applied for the improvement of photocatalytic (removal of organic contaminants from water/wastewater and H 2 production and CO 2 reduction reactions) efficiency, electrocatalytic (hydrogen/oxygen evolution reactions and CO 2 reduction reactions), and energy storage performances (supercapacitor) of CeO 2 ‐based materials. Herein, the recent progress of CeO 2 ‐based materials for electro(photo)catalysis and energy storage applications has been discussed. The challenges and possible direction of CeO 2 ‐based materials for electro(photo)catalysis and energy storage applications have been emphasized. Furthermore, this comprehensive review is expected to advance the design of CeO 2 ‐based materials and their applications in electro(photo)catalysis and energy.

Ray, Schindra Kumar [Department of Chemistry North↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

Effect of Storage on Performance of Super Nickel-Cadmium Cells

A study was undertaken to examine the capacity maintenance features of SUPER nickel-cadmium cells when stored for extended periods to determine whether the features change when the same kinds of positive plates as that used in nickel-hydrogen cells are used, The cells maintained their capacity when stored at 0 C in the discharged state and at 0 C in the charged state by continuously trickle charging. There was a capacity loss when stored in the open-circuit condition at 28 C. A cycling test at 17% depth of discharge for 2400 cycles using cells stored at various conditions showed that cells maintained good end of discharge voltage regardless of their storage history. However, the EOD voltages of stored cells were lower by 10 mV compared to those of fresh cells. The capacity at the end of the cycling test decreased for the stored cells by 2-7 Ah. The storage related capacity loss is lower for SUPER Ni-Cd cells compared to that of Ni-H2 cells containing a hydrogen precharge. The results suggest the pivotal role of hydrogen pressure in the capacity loss phenomenon.

Vaidyanathan, Hari↗