Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “standalone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The proximity effect and critical field behavior of Re/Al bilayers

Abstract We report the perpendicular critical field H c 2 properties of disordered Re-Al bilayers via magneto-transport measurements. The bilayers consisted of a d Re = 3 nm bottom layer of Re and an upper Al layer with thickness varying between d Al = 0 − 3 nm. We find that in this range of Al thicknesses, the bilayer transition temperature T c increases with increasing Al thickness, although their monolayer counterparts have T c Re > T c Al . Furthermore, H c 2 of the bilayers has a local maximum at an Al coverage of 1.5 nm with a critical field that is 50% larger than that of the standalone 3 nm Re film. At higher Al thicknesses H c 2 drops rapidly but remains more than an order of magnitude greater that that of comparable thickness standalone Al film. Our data show that a thin, disordered Re under-layer can dramatically increase the magnetic field tolerance of the Al over-layer. This would allow one to retain the desirable chemical and metallurgical properties of Al without sacrificing high field compatibility in quantum circuits, such as topological qubit devices and superinductor circuits.

Womack, F. N. (ORCID:0009000810391507)↗

The AXEAP2 program for K β X-ray emission spectra analysis using artificial intelligence

The processing and analysis of synchrotron data can be a complex task, requiring specialized expertise and knowledge. Our previous work addressed the challenge of X-ray emission spectrum (XES) data processing by developing a standalone application using unsupervised machine learning. However, the task of analyzing the processed spectra remains another challenge. Although the non-resonant K β XES of 3 d transition metals are known to provide electronic structure information such as oxidation and spin state, finding appropriate parameters to match experimental data is a time-consuming and labor-intensive process. Here, a new XES data analysis method based on the genetic algorithm is demonstrated, applying it to Mn, Co and Ni oxides. This approach is also implemented as a standalone application, Argonne X-ray Emission Analysis 2 ( AXEAP2 ), which finds a set of parameters that result in a high-quality fit of the experimental spectrum with minimal intervention. AXEAP2 is able to find a set of parameters that reproduce the experimental spectrum, and provide insights into the 3 d electron spin state, 3 d –3 p electron exchange force and K β emission core-hole lifetime.

36 MATERIALS SCIENCE↗

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗

A Networked Microgrid Framework and Testbed for Communication, Controls, and Optimization Testing

This paper presents the development and experimental results of a networked AC microgrid testbed located at Oak Ridge National Laboratory. The testbed comprises two, 480V three-phase, four wire microgrids designed to operate standalone, grid-tied, or as a network of microgrids. This testbed represents both the state of the industry, by incorporating grid-assets commonly found in real microgrids, and the state of the art, as it is a platform to evaluate advanced controllers. The main elements of this networked microgrid testbed are presented in this paper including a Scenario Manager, local microgrid controls, and a networked microgrid control. The Scenario Manager has the objective of emulating real-world conditions. The local microgrid controller oversees standalone, grid-tied, or islanded operation. The microgrid control is a higher-level control that coordinates interaction between islanded microgrids. This paper delves into these controllers and validates their operation in the networked microgrid testbed showcasing the operational flexibility and advance control capabilities.

Ferrari Maglia, Max↗

Enhancing Network Anomaly Detection Using Graph Neural Networks

In the world of Internet of Things (IoT) networks, where devices are constantly communicating, keeping them secure from cyber threats is critical. This paper introduces a novel approach to detecting unusual and potentially harmful activities in these networks using graph neural networks (GNNs). We combine two specific types of GNNs-GraphSAGE and graph attention networks (GAT)-to create a model that understands and represents the behaviors and interactions in a network. GraphSAGE creates an embedding of network activities by examining local data interactions, while GAT directs the model's focus to the most critical interactions. By integrating these two methods in a single model that considers different types of interactions (both host and flow nodes), we aim to create a system that accurately represents the current state of a network and can also spot anomalies effectively while reducing false positives and negatives. Our innovative approach has demonstrated promising results, achieving an accuracy of 98% on the UNSW-NB15 dataset, significantly outperforming standalone GraphSAGE and GAT models. This underscores its potential as a robust framework for securing IoT networks against cyber threats and anomalies.

Marfo, William↗

Retargetable Optimizing Compilers for Quantum Accelerators via a Multi-Level Intermediate Representation

In this work, we present a multi-level quantum-classical intermediate representation (IR) that enables an optimizing, retargetable compiler for available quantum languages. Our work builds upon the Multi-level Intermediate Representation (MLIR) framework and leverages its unique progressive lowering capabilities to map quantum languages to the LLVM machine-level IR. We provide both quantum and classical optimizations via the MLIR pattern rewriting sub-system and standard LLVM optimization passes, and demonstrate the programmability, compilation, and execution of our approach via standard benchmarks and test cases. In comparison to other standalone language and compiler efforts available today, our work results in compile times that are 1000x faster than standard Pythonic approaches, and 5-10x faster than comparative standalone quantum language compilers. Our compiler provides quantum resource optimizations via standard programming patterns that result in a 10x reduction in entangling operations, a common source of program noise. We see this work as a vehicle for rapid quantum compiler prototyping.

43 PARTICLE ACCELERATORS↗

Grid-Forming and Grid-Following Inverter Comparison of Droop Response

With the increase in penetration of inverter-based resources (IBRs) in the electrical power system, the ability of these devices to provide grid support to the system has become a necessity. With standards previously developed for the interconnection requirements of grid-following inverters (GFLI) (most commonly photovoltaic inverters), it has been well documented how these inverters “should” respond to changes in voltage and frequency. However, with other IBRs such as grid-forming inverters (GFMIs) (used for energy storage systems, standalone systems, and as uninterruptable power supplies) these requirements are either: not yet documented, or require a more in deep analysis. With the increased interest in microgrids, GFMIs that can be paralleled onto a distribution system have become desired. With the proper control schemes, a GFMI can help maintain grid stability through fast response compared to rotating machines. This paper will present an experimental comparison of commercially available GFMI and GFLI ' responses to voltage and frequency deviation, as well as the GFMI operating as a standalone system and subjected to various changes in loads.

Grid Support, Inverter, Droop Control, Volt-VAR, F↗

Accelerating Noisy VQE Optimization with Gaussian Processes

Hybrid variational quantum algorithms, which combine a classical optimizer with evaluations on a quantum chip, are the most promising candidates to show quantum advantage on current noisy, intermediate-scale quantum (NISQ) devices. The classical optimizer is required to perform well in the presence of noise in the objective function evaluations, or else it becomes the weakest link in the algorithm. We introduce the use of Gaussian Processes (GP) as surrogate models to reduce the impact of noise and to provide high quality seeds to escape local minima, whether real or noise-induced. We build this as a framework on top of local optimizations, for which we choose Implicit Filtering (ImFil) in this study. ImFil is a state-of-the-art, gradient-free method, which in comparative studies has been shown to outperform on noisy VQE problems. The result is a new method: "GP+ImFil". We show that when noise is present, the GP+ImFil approach finds results closer to the true global minimum in fewer evaluations than standalone ImFil, and that it works particularly well for larger dimensional problems. Using GP to seed local searches in a multi-modal landscape shows mixed results: although it is capable of improving on ImFil standalone, it does not do so consistently and would only be preferred over other, more exhaustive, multistart methods if resources are constrained.

Muller, Juliane↗

AGU/AMS Abstract Search and Display Software

The AGU/AMS Abstract Search and Display Software is a standalone web application which enables the searching, storing, and displaying of abstracts featured at the annual American Geophysical Union (AGU) and American Meteorological Society (AMS) meetings. This application is designed for those who wish to host a standalone web application and feature a select subset of posters and talks scheduled for the AGU/AMS meetings. Please read the entirety of this README.md file before attempting to download and use the application. There are three views available via the UI: Lookup - enables searching and submitting posters for displaying on the summary view Manual Submission - allows individual manual submission of posters given a poster ID Summary - displays all posters submitted by users from the lookup view

Darnell, Wade↗

3rd harmonic magnetometry assessment of NbTiN-based SIS structures

In the quest for alternative superconducting materials to bring accelerator cavity performance beyond the bulk niobium (Nb) intrinsic limits, a promising concept proposes that superconductor-insulator-superconductor (SIS) thin film structures can delay magnetic flux penetration in accelerator cavities to higher fields [1]. NbTiN is a candidate superconductor for such structures. We have demonstrated high quality NbTiN and AlN deposited by reactive direct current magnetron sputtering (DCMS), both for individual layers and multilayers. Interface quality has been assessed for bi-layer stacks with various NbTiN and AlN thicknesses from 500 and 30 nm down to 3 and 1 nm. These SIS structures show continued sharp interfaces. The Hfp enhancement of the films was examined with 3rd harmonic magnetometry. The system was designed and built in an ongoing collaboration with CEA Saclay. It can measure 1? to 2? samples on a temperature controlled stage. This contribution presents the assessment of the first penetration field enhancement with 3rd harmonic magnetometry for standalone films and multilayer nanostructures.

Valente, Anne-Marie↗

Modeling Environmental Effects on Ventilated Spent Fuel Storage Systems

This report describes newly developed external environment wind effects models of spent nuclear fuel (SNF) dry storage systems. The primary purpose of these wind effects models is to better understand particle deposition on SNF canisters in the context of chloride-induced stress corrosion cracking. The goal of this effort is to further the understanding and improve the wind effects model of the Nuclear Horizontal Modular Storage (NUHOMS ® ) Advanced Horizontal Storage Module–High Seismic (AHSM-HS) storage system in support of the planned Canister Deposition Field Demonstration (CDFD) project (Durbin et al. 2021, Suffield et al. 2021). The steps in this wind effects investigation begin with a validation case of comparing experimental data with a STAR-CCM+ computational fluid dynamics (CFD) model of the Belowground Vertical Dry Cask Simulator (BVDCS) with the external environment explicitly modeled. Next, a test case is performed with the AHSM-HS models comparing solar-loading strategies for a standalone and wind effects model in STAR-CCM+ and a standalone model in ANSYS Mechanical Parametric Design Language (APDL). The final portion of this study compares results of the validation exercise with applications of wind effects models for two horizontal storage systems, a site specific NUHOMS ® horizontal storage module and a NUHOMS ® AHSM-HS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hybrid Power Plants: Status of Operating and Proposed Plants, 2022 Edition [Slides]

Falling battery prices and the growth of variable renewable generation are driving a surge of interest in “hybrid” power plants that combine, for example, wind or solar generating capacity with co-located batteries. While most of the current interest involves pairing photovoltaic (PV) plants with batteries, other types of hybrid or co-located plants with wide-ranging configurations have been part of the U.S. electricity mix for decades. This annually updated briefing tracks and maps existing hybrid or co-located plants across the United States while also synthesizing data mined from power purchase agreements (PPAs) and generation interconnection queues to shed light on near- and long-term development pipelines. The scope includes co-located hybrid plants that pair two or more generators and/or that pair generation with storage at a single point of interconnection, and full hybrids that feature co-location and co-control. The focus is on plants with one megawatt (MW) or more of capacity; smaller (often behind-the-meter) projects are also increasingly common, but are not included in this data synthesis. Key findings from the latest briefing include: -At the end of 2021, there were nearly 300 hybrid plants (>1 MW) operating across the United States, totaling nearly 36 gigawatts (GW) of generating capacity and 3.2 GW/8.1 GWh of energy storage. PV+storage plants are by far the most common, dominating in terms of plant number (140), storage capacity (2.2 GW/7.0 GWh), storage:generator ratio (53%), and storage duration (3.2 hours). But there are nearly twenty other hybrid plant configurations as well, including several different fossil hybrid categories (each dominated by the fossil component) as well as wind+storage, wind+PV, wind+PV+storage, geothermal+PV, and others. -Last year was a breakout year for PV+storage hybrids in particular: 67 of the 74 hybrids added in 2021 were PV+storage. By the end of 2021, there were more GW of battery capacity installed in PV+storage hybrids (2.2 GW) than as standalone storage plants (1.8 GW). The difference is even starker in energy terms, with PV+storage plants hosting twice as much battery capacity as standalone storage plants (7 GWh vs. 3.5 GWh, respectively). Much of the battery capacity added in hybrid form in 2021 was a battery retrofit to a pre-existing PV plant. -Data on plants under development from the interconnection queues of all seven ISOs/RTOs plus 35 individual utilities suggest that these hybridization trends are likely to continue. At the close of 2021, there were more than 670 GW of solar plants in the nation’s queues; 285 GW (~42%) of this capacity was proposed as a hybrid, most typically pairing PV with battery storage (PV+storage represented nearly 90% of all hybrid capacity in the queues). For wind, 247 GW of capacity sat in the queues, with 19 GW (~8%) proposed as a hybrid, again most-often pairing wind with storage (wind+storage represented ~4% of all hybrid capacity in the queues). Meanwhile, nearly half of all storage in the queues is estimated to be part of a hybrid plant. While many of these proposed plants will not ultimately reach commercial operations, the depth of interest in hybrid plants—especially PV+storage—is notable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microcam: A Low Power and Privacy Preserving Multi-modal Platform for Occupancy Detection (Final Report)

Heating, ventilation, and air conditioning (HVAC) consumes a significant portion of the energy used in buildings. Much of this is wasted energy, used when buildings are either not occupied at all, or occupied well under their maximum design conditions. This project has focused on residential occupancy detection to autonomously control HVAC systems and save energy. Limitations of existing occupancy sensors include one or more of the following: (i) they employ sensors or algorithms that are not able to detect stationary occupants; (ii) they cannot classify the source of the motion (such as a pet); (iii) depending on the camera resolution and employed algorithms, they do not allow for embedded or onboard computation, and require external or cloud-based processing; (iv) many algorithms developed for camera-based systems are sensitive to lighting changes, and thus prone to missed detections or false alarms; (v) Most existing systems depend on adjustment of settings for different scenarios, complicating self-commissioning; (vi) they cannot provide high enough accuracy; (vii) they are costly; (viii) they are not battery-powered, thus limiting ease of use and installation. In this project, Syracuse University and its partner SRI have developed a low-cost, high accuracy, standalone residential occupancy sensing platform, referred to as the MicroCam, to address all of the aforementioned challenges. MicroCam can operate on typical alkaline batteries without relying on the “cloud” or external computing resources, and consists of low-power, Artificial Intelligence (AI)-based, IoT platforms. Each platform has multi-modal sensors and can process motion, audio and video data, and send binary occupancy result to a lead platform. All sensor data is processed locally on platforms, and the only transmitted data is the binary occupancy state. In addition, preliminary work has been done on images wherein occupants are not discernable. Thus, MicroCam is a standalone solution preserving privacy of the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Power Plants: Status of Operating and Proposed Plants, 2023 Edition [Slides]

Improving battery technology and the growth of variable renewable generation are driving a surge of interest in “hybrid” power plants that combine, for example, wind or solar generating capacity with co-located batteries. While most of the current interest involves pairing photovoltaic (PV) plants with batteries, other types of hybrid or co-located plants with wide-ranging configurations have been part of the U.S. electricity mix for decades. This annually updated briefing tracks and maps existing hybrid or co-located plants across the United States while also synthesizing data from power purchase agreements (PPAs) and generation interconnection queues to shed light on near- and long-term development pipelines. The scope includes “co-located hybrids” that pair two or more resources (e.g., multiple types of generation and/or generation with storage) that are operated largely independently behind a single point of interconnection, and “full hybrids” that also feature coordinated operations of the co-located resources. The focus is on plants with one megawatt (MW) or more of capacity; smaller (often behind-the-meter) projects are also increasingly common, but are not included in this data synthesis. Key findings from the latest briefing include: -At the end of 2022, there were 374 hybrid plants (>1 MW) operating across the United States (+25% compared to the end of 2021), totaling nearly 41 GW of generating capacity (+15%) and 5.4 GW/15.2 GWh of energy storage (+69%/+88%). PV+storage plants are by far the most common, dominating in terms of plant number (213), storage capacity (4.0 GW/12.5 GWh), storage:generator capacity ratio (49%), and storage duration (3.1 hours). But there are nearly twenty other hybrid plant configurations as well, including several different fossil hybrid categories (each dominated by the fossil component) as well as wind+storage, wind+PV, wind+PV+storage, geothermal+PV, and others. -Last year was another strong year for PV+storage hybrids in particular: 59 of the 62 hybrids added in 2022 were PV+storage. As of the end of 2022, there was roughly as much storage capacity operating within PV+storage hybrid plants as in standalone storage plants (~4 GW each). In storage energy terms, however, PV+storage edged out standalone storage by ~2 GWh (12.5 GWh vs. 10.4 GWh, respectively). -Interconnection queue data show continued strong developer interest in hybridization. At the close of 2022, there were 51% more hybrid plants—representing 59% more generating capacity—in interconnection queues across the United States than there were at the end of 2021. Solar dominates these proposed plants as well: at the close of 2022, there were 457 GW of solar capacity proposed as a hybrid (representing ~48% of all solar capacity in the queues), most typically pairing PV with battery storage. At the same time, there were 24 GW of wind capacity proposed as a hybrid (representing ~8% of all wind capacity in the queues), again most-often pairing wind with storage. Meanwhile, more than half of all storage in the queues is estimated to be part of a hybrid plant. While many of the plants proposed in the queues will not ultimately reach commercial operations, the depth of interest in hybrid plants—especially PV+storage—is notable, particularly in certain regions. For example, in CAISO, 97% of all solar capacity and 45% of all wind capacity in the queues is proposed as a hybrid. -The report also surveys power purchase agreement (PPA) price data from a sample of operating and proposed PV+storage plants. Though PV+storage PPA prices have fallen over time, “levelized storage adders” have recently increased somewhat to ~$\$ $7000/MW-month, ~$\$ $60/MWh-stored (assuming one full cycle per day), or ~$\$ $15/MWh-PV. Some of the recent price increase could simply reflect a trend towards higher battery:PV capacity ratios over time, which increases costs, all else being equal. The well-publicized impact of inflationary and supply chain pressures on battery prices is no doubt a contributor as well.

25 ENERGY STORAGE↗

Liquid rocket booster study. Volume 2, book 5, appendix 9: LRB alternate applications and evolutionary growth

The analyses performed in assessing the merit of the Liquid Rocket Booster concept for use in alternate applications such as for Shuttle C, for Standalone Expendable Launch Vehicles, and possibly for use with the Air Force's Advanced Launch System are presented. A comparison is also presented of the three LRB candidate designs, namely: (1) the LO2/LH2 pump fed, (2) the LO2/RP-1 pump fed, and (3) the LO2/RP-1 pressure fed propellant systems in terms of evolution along with design and cost factors, and other qualitative considerations. A further description is also presented of the recommended LRB standalone, core-to-orbit launch vehicle concept.

Source record↗

Access Control of Web- and Java-Based Applications

Cybersecurity has become a great concern as threats of service interruption, unauthorized access, stealing and altering of information, and spreading of viruses have become more prevalent and serious. Application layer access control of applications is a critical component in the overall security solution that also includes encryption, firewalls, virtual private networks, antivirus, and intrusion detection. An access control solution, based on an open-source access manager augmented with custom software components, was developed to provide protection to both Web-based and Javabased client and server applications. The DISA Security Service (DISA-SS) provides common access control capabilities for AMMOS software applications through a set of application programming interfaces (APIs) and network- accessible security services for authentication, single sign-on, authorization checking, and authorization policy management. The OpenAM access management technology designed for Web applications can be extended to meet the needs of Java thick clients and stand alone servers that are commonly used in the JPL AMMOS environment. The DISA-SS reusable components have greatly reduced the effort for each AMMOS subsystem to develop its own access control strategy. The novelty of this work is that it leverages an open-source access management product that was designed for Webbased applications to provide access control for Java thick clients and Java standalone servers. Thick clients and standalone servers are still commonly used in businesses and government, especially for applications that require rich graphical user interfaces and high-performance visualization that cannot be met by thin clients running on Web browsers

Tso, Kam S.↗

Generic Airspace Research Phase 5 Report

Human-in-the-loop testing was completed to assess the subjective preferences, usage, and operational benefits of Integrated and Separated Controller Information Tools (CITs) in support of Generic Airspace Research. Participants controlled traffic in in a busy, high altitude sector with the aid of the CITs. When the participants were asked which CIT that they preferred to use, they overwhelmingly chose the integrated version of the CIT. The primary reason for this seemed to be that it allowed participants to remain focused on the traffic situation, whereas the Standalone CIT required them to focus their attention for short periods away from the radar presentation. In contrast to their preference, there were little or no differences in the CIT usage and the operational differences. There were similar numbers of losses of separation and participants accessed each CIT equally. Although the information accessed was the similar for the two conditions, participants actively turned off the data on the Integrated CIT, presumably to reduce the clutter on the radar scope. Further work is needed to isolate which information can and should be available to controllers in the Integrated vs. Standalone format.

controller information tool↗

An Evaluation of Detect and Avoid (DAA) Displays for Unmanned Aircraft Systems: The Effect of Information Level and Display Location on Pilot Performance

A consortium of government, industry and academia is currently working to establish minimum operational performance standards for Detect and Avoid (DAA) and Control and Communications (C2) systems in order to enable broader integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS). One subset of these performance standards will need to address the DAA display requirements that support an acceptable level of pilot performance. From a pilot's perspective, the DAA task is the maintenance of self separation and collision avoidance from other aircraft, utilizing the available information and controls within the Ground Control Station (GCS), including the DAA display. The pilot-in-the-loop DAA task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots' ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The authors propose an eight-stage pilot-DAA interaction timeline from which several pilot response time metrics can be extracted. These metrics were compared across the four display conditions. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays. Implications of the findings on understanding pilot performance on the DAA task, the development of DAA display performance standards, as well as the need for future research are discussed.

detect and avoid↗