Engineering PapersSearch

SEARCH · Engineering Papers

Results for “stage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Single-stage evaluation of highly-loaded high-Mach-number compressor stages 5. Data and performance of baseline, corner-blow wall suction and combined corner blow wall suction stator

A single-stage compressor with a rotor tip speed of 1600 ft/sec and a 0.5 hub tip ratio was used to investigate the effects of several stator endwall treatment methods on stage range and performance. These endwall treatment methods consisted of stator corner-blow, annular wall suction upstream of stator leading edge, and combined corner-blow and annular wall suction. The overall stage performance with corner blow was essentially the same as the baseline performance. The performance for the annular wall suction and the combined corner-blow and wall suction showed a reduction in peak efficiency of 2.5 percentage points compared to the baseline data.

Nikkanen, J. P.

Single-stage experimental evaluation of tandem-airfoil rotor and stator blading for compressors. Part 2: Data and performance for stage A

Stage A, comprised of a conventional rotor and stator, was designed and tested to establish a performance baseline for comparison with the results of subsequent tests planned for two tandem-blade stages. The rotor had an inlet hub/tip ratio of 0.8 and a design tip velocity of 757 ft/sec. At design equivalent rotor speed, rotor A achieved a maximum adiabatic efficiency of 85.1 percent at a pressure ratio of 1.29. The stage maximum adiabatic efficiency was 78.6 percent at a pressure ratio of 1.27.

Brent, J. A.

Single-stage experimental evaluation of tandem-airfoil rotor and stator blading for compressors. Part 5: Analysis and design of stages D and E

A conventional and a tandem bladed stage were designed for a comparative experimental evaluation in a 0.8 hub/tip ratio single-stage compressor. Based on a preliminary design study, a radially constant work input distribution was selected for the rotor designs. Velocity diagrams and blade leading and trailing edge angles selected for the conventional rotor and stator were used in the design of the tandem blading. The effects of axial velocity ratio and secondary flow on turning were included in the selection of blade leading and trailing edge angles. Design values of rotor tip velocity and stage pressure ratio were 757 ft/sec and 1.26, respectively.

Brent, J. A.

Space shuttle program. Expendable second stage reusable space shuttle booster. Volume 2: Technical summary. Book 2: Expendable second stage vehicle definition

A definition of the expendable second stage for use with the reusable space shuttle booster is presented. The subjects discussed are: (1) expendable second stage design, (2) structural subsystem, (3) propulsion subsystem, (4) avionics subsystems, (5) recovery and deorbit subsystem, and (6) expendable second stage vehicle installation, assembly, and checkout.

Source record

Cold-air investigation of a 3 1/2-stage fan-drive turbine with a stage loading factor of 4 designed for an integral lift engine. 1: Turbine design and performance of first stage

The design of the 3 1/2-stage turbine is described, and the cold-air performance of the first stage, modified for axial inlet conditions, is presented. The performance of the modified single-stage turbine and of two comtemporary high-stage-loading-factor turbines is compared with that estimated with a reference prediction method.

Whitney, W. J.

Performance of two-stage fan having low-aspect-ratio first-stage rotor blading

The NASA two stage fan was tested with a low aspect ratio first stage rotor having no midspan dampers. At design speed the fan achieved an adiabatic design efficiency of 0.846, and peak efficiencies for the first stage and rotor of 0.870 and 0.906, respectively. Peak efficiency occurred very close to the stall line. In an attempt to improve stall margin, the fan was retested with circumferentially grooved casing treatment and with a series of stator blade resets. Results showed no improvement in stall margin with casing treatment but increased to 8 percent with stator blade reset.

Urasek, D. C.

Performance of two-stage fan with a first-stage rotor redesigned to account for the presence of a part-span damper

The NASA two-stage fan was tested with a redesigned first-stage rotor. The redesign included a new design approach to account for the presence of a part-span damper. At design speed the fan achieved a peak efficiency of 0.803, which is 1.9 percentage points higher than the original design. The peak efficiencies of the first stage and first rotor were 0.789 and 0.821, respectively. An improvement in efficiency of up to 5 percentage points in the damper region was achieved over the original large damper version. The stall margin, based on flow conditions at peak efficiency, was 10 percent at design speed.

Gorrell, W. T.

Experimental Vibration Damping Characteristics of the Third-stage Rotor of a Three-stage Transonic Axial-flow Compressor

Rotor blade aerodynamic damping is experimentally determined in a three-stage transonic axial flow compressor having design aerodynamic performance goals of 4.5:1 pressure ratio and 65.5 lbm/sec weight flow. The combined damping associated with each mode is determined by a least squares fit of a single degree of freedom system transfer function to the nonsynchronous portion of the rotor blade strain gage output power spectra. The combined damping consists of the aerodynamic damping and the structural and mechanical damping. The aerodynamic damping varies linearly with the inlet total pressure for a given corrected speed, weight flow, and pressure ratio while the structural and mechanical damping is assumed to remain constant. The combined damping is determined at three inlet total pressure levels to obtain the aerodynamic damping. The third-stage rotor blade aerodynamic damping is presented and discussed for the design equivalent speed with the stator blades reset for maximum efficiency. The compressor overall preformance and experimental Campbell diagrams for the third-stage rotor blade row are also presented.

Newman, Frederick A.

Experimental vibration damping characteristics of the third-stage rotor of a three-stage transonic axial-flow compressor

Rotor blade aerodynamic damping is experimentally determined in a three-stage transonic axial flow compressor having design aerodynamic performance goals of 4.5:1 pressure ratio and 65.5 lbm/sec weight flow. The combined damping associated with each mode is determined by a least squares fit of a single degree of freedom system transfer function to the nonsynchronous portion of the rotor blade strain gage output power spectra. The combined damping consists of the aerodynanmic damping and the structural and mechanical damping. The aerodynamic damping varies linearly with the inlet total pressure for a given corrected speed, weight flow, and pressure ratio while the structural and mechanical damping is assumed to remain constant. The combined damping is determined at three inlet total pressure levels to obtain the aerodynamic damping. The third-stage rotor blade aerodynamic damping is presented and discussed for the design equivalent speed with the stator blades reset for maximum efficiency. The compressor overall performance and experimental Campbell diagrams for the third-stage rotor blade row are also presented.

Newman, Frederick A.

Investigation of Two-Stage Counterrotating Compressor. III: Design of Second-Stage Rotor and Preliminary Over-All Performance

At the design speed of a two-stage counterrotating compressor, an overall average pressure ratio of 4.3 was obtained at a specific weight flow of 27.2 pounds per second per square foot frontal area with an adiabatic efficiency of 0.75. Preliminary tests indicate that a weight-flow mismatching exists between the two rotors that causes the first rotor to operate at less than peak efficiency at design speed. At lower speeds, the first stage was forced to operate in the stalled region in single-stage tests. With the second rotor installed, no periodic rotating stall was observed, although random fluctations of similiar magnitude were noted.

Wilcox, Ward W

Overview of Transonic to Hypersonic Stage Separation Tool Development for Multi-Stage-to-Orbit Concepts

An overview of research efforts at NASA in support of the stage separation and ascent aerothermodynamics research program is presented. The objective of this work is to develop a synergistic suite of experimental, computational, and engineering tools and methods to apply to vehicle separation across the transonic to hypersonic speed regimes. Proximity testing of a generic bimese wing-body configuration is on-going in the transonic (Mach numbers 0.6, 1.05, and 1.1), supersonic (Mach numbers 2.3, 3.0, and 4.5) and hypersonic (Mach numbers 6 and 10) speed regimes in four wind tunnel facilities at the NASA Langley Research Center. An overset grid, Navier-Stokes flow solver has been enhanced and demonstrated on a matrix of proximity cases and on a dynamic separation simulation of the bimese configuration. Steady-state predictions with this solver were in excellent agreement with wind tunnel data at Mach 3 as were predictions via a Cartesian-grid Euler solver. Experimental and computational data have been used to evaluate multi-body enhancements to the widely-used Aerodynamic Preliminary Analysis System, an engineering methodology, and to develop a new software package, SepSim, for the simulation and visualization of vehicle motions in a stage separation scenario. Web-based software will be used for archiving information generated from this research program into a database accessible to the user community. Thus, a framework has been established to study stage separation problems using coordinated experimental, computational, and engineering tools.

Murphy, Kelly J.

Performance of 15-Stage Experimental J71 Axial-Flow Compressor: II - Individual Stage Performance Characteristics

The first four stages were found to cause a major part of the poor low-speed efficiency of this compressor. The low design-speed over-all pressure ratio at surge was caused by the first and the twelfth to fifteenth stages. The multiple over-all performance curves in the intermediate-speed range were at least partly the result of double-branched characteristic curves for the third and seventh stages.

Lucas, James G.

Effect of Various Blade Modifications on Performance of a 16-Stage Axial-Flow Compressor. II - Effect on Over-All Performance Characteristics of Increasing Twelfth through Fifteenth Stage Stator-Blade Angles 3 deg

The stator-blade angles in the twelfth through fifteenth stages of a 16-stage axial-flow compressor were increased 3O. The over-all performance of this modified compressor is compared to the performance of the compressor with original blade angles. The matching characteristics of the modified compressor and a two-stage turbine were obtained and compared to those of the compressor with original blade angles and the same turbine.

Hatch, James E.

Effect of Various Blade Modifications on Performance of a 16-Stage Axial-Flow Compressor. III - Effect on Over-All Performance Characteristics on Increasing Stator-Blade Angles in Inlet Stages

The stator-blade angles in the first four stages of a 16-stage axial-flow compressor were increased in order to decrease the angles of attack of these stages, and thereby to improve part-speed performance. The performance of this modified compressor was compared with that of the same compressor with original blade angles.

Medeiros, Arthur A.