Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroRadiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Shortwave Array Spectroradiometer–Hemispheric (SASHe) Instrument Handbook

The Shortwave Array Spectroradiometer–Hemispheric (SASHe) provides measurements of direct solar, hemispheric diffuse, and total hemispheric shortwave irradiance over a continuous spectral range from approximately 300 nm to 1700 nm at a rate of about 30 seconds. The SASHe design connects an optical collector located outdoors to a pair of spectrometers and data collections systems located indoors within a climate-controlled building via an umbilical cable of fiber optic and electrical cables. The light collector uses a small Spectralon button as a hemispheric diffuser with a shadowband to distinguish signal from diffuse sky and direct sun.

54 ENVIRONMENTAL SCIENCES↗

Moderate spectral resolution solar irradiance measurements, aerosol optical depth, and solar transmission, from 360 to 1070 nm, using the refurbished rotating shadow band spectroradiometer (RSS)

Abstract. This paper reports on a third-generation rotating shadow band spectroradiometer (RSS) used to measure global and diffuse horizontal plus direct normal irradiances and transmissions at 1002 wavelengths between 360 and 1070 nm. The prism-dispersed spectral data are from the Atmospheric Radiation Measurement (ARM) Southern Great Plains site in north-central Oklahoma (36.605∘ N, 97.486∘ W) and cover dates between August 2009 and February 2014. The refurbished RSS isolates the detector in a vacuum chamber with pressures near 10−7 torr. This prevents the deposition of outgassed vapors from the interior of the spectrometer shell on the cooled detector that affected the operation of the first commercial RSS. Methods for (1) ensuring the correct wavelength registration of the data and (2) deriving extraterrestrial responses over the entire spectrum, including throughout strong water vapor and oxygen bands, are described. The resulting data produced are archived as ARM data records and include cloud-screened aerosol optical depths, spectral irradiances and direct normal solar transmission, as well as normalized diffuse and global irradiances.

54 ENVIRONMENTAL SCIENCES↗

Shortwave Array Spectroradiometer-Hemispheric (SAS-He): design and evaluation

A novel ground-based radiometer, referred to as the Shortwave Array Spectroradiometer-Hemispheric (SAS-He), is introduced. This radiometer uses the shadow-band technique to report total irradiance and its direct and diffuse components frequently (every 30 s) with continuous spectral coverage (350–1700 nm) and moderate spectral (~2.5 nm ultraviolet–visible and ~6 nm shortwave-infrared) resolution. The SAS-He's performance is evaluated using integrated datasets collected over coastal regions during three field campaigns supported by the US Department of Energy's Atmospheric Radiation Measurement (ARM) program, namely the (1) Two-Column Aerosol Project (TCAP; Cape Cod, Massachusetts), (2) Tracking Aerosol Convection Interactions Experiment (TRACER; in and around Houston, Texas), and (3) Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE; La Jolla, California). We compare (i) aerosol optical depth (AOD) and total optical depth (TOD) derived from the direct irradiance, as well as (ii) the diffuse irradiance and direct-to-diffuse ratio (DDR) calculated from two components of the total irradiance. As part of the evaluation, both AOD and TOD derived from the SAS-He direct irradiance are compared to those provided by a collocated Cimel sunphotometer (CSPHOT) at five (380, 440, 500, 675, 870 nm) and two (1020, 1640 nm) wavelengths, respectively. Additionally, the SAS-He diffuse irradiance and DDR are contrasted with their counterparts offered by a collocated multifilter rotating shadowband radiometer (MFRSR) at six (415, 500, 615, 675, 870, 1625 nm) wavelengths. Overall, reasonable agreement is demonstrated between the compared products despite the challenging observational conditions associated with varying aerosol loadings and diverse types of aerosols and clouds. For example, the AOD- and TOD-related values of root mean square error remain within 0.021 at 380, 440, 500, 675, 870, 1020, and 1640 nm wavelengths during the three field campaigns.

47 OTHER INSTRUMENTATION↗

Infrared spectroradiometer for rocket exhaust analysis

Infrared spectroradiometer measures high-resolution spectral absorption, emission, temperature, and concentration of chemical species in radically symmetric zones of the exhaust plumes of large rocket engines undergoing static firing tests. Measurements are made along predetermined lines of sight through the plume.

Herget, W. F.↗

Improved relay optical element for spectroradiometer using cryogenically cooled detector

By coating half of one element in the relay optical system of a spectroradiometer with a very high emissivity paint, the effect of the reflected radiation from the back of the filter wheel is eliminated optically. This causes the detector to view a constant level of radiation, regardless of how the reflectivity of the back of the filter wheel changes.

Kraemer, A. R.↗

Compact spectroradiometer

Development and characteristics of spectroradiometer with wedge filters to eliminate adverse effect of pinholes in filters

Seward, H. H.↗

Study of dual-channel infrared spectroradiometer systems

A dual channel infrared spectroradiometer system was installed at a high altitude facility where spectral data were obtained from F2/H2, FLOX/CH4, FLOX/B2H6, OF2/CH4, and OF2/B2H6 propellant combinations. A good HF emission spectra was obtained for tests with the OF2B2H6 propellant combination. Subsequently, data were obtained on the LOX/GH2 propellant combination at sea level and altitude conditions that were inconsistent because the calculation of plume properties led to physically unrealistic results. The inconsistencies resulted from measurement accuracy not being within the narrow limits required by the data reduction scheme. Although the anticipated program results were not obtained, the data gathered are useful for guiding future experimental efforts and formulations of less sensitive analytical models.

Wrubel, J. A.↗