Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spallation source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Neutronics Analyses for the Spallation Neutron Source Second Target Station

The Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), two of the word-class neutron scattering facilities, are located at the Oak Ridge National Laboratory. The SNS and HFIR are funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Science, and are operated as user facilities, available to researchers from all over the world. Currently there are thirteen neutron scattering instruments in operation at the HFIR and twenty at the SNS First Target Station.Producing the cutting edge science requires continuous improvements and development of the facilities and instruments. The SNS was designed from the beginning to allow addition of the Second Target Station (STS), and an upgrade of the accelerator power. At this time both advances: the accelerator upgrade and the construction of the STS are in preparation.Current baseline design for the STS calls for a rotating compact tungsten target. The target station is driven with short (<1 μs) proton pulses at 10 Hz repetition rate and 467 kW proton beam power, and is optimized for high intensity and high resolution long wavelength neutron applications. The proton beam footprint as small as acceptable from the mechanical and heat removal aspects is planned to generate a compact-volume neutron production zone in the target, which is essential for tight coupling of the target and the moderators and for achieving high-intensity peak thermal and cold neutron fluxes. The STS will allow operation of approximately 22 beamlines and will expand and complement the current national neutron scattering capabilities.This paper will present an update of the status of the neutronics analyses performed for the STS and will discuss the performance of the moderators, heating rates, activation analyses, and shielding calculations which provide input in the engineering design.

Remec, Igor↗

Conceptual moderator studies for the Spallation Neutron Source short-pulse second target station

Candidate moderator configurations for a short-pulse second target station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) have been identified using a global optimizer framework built around the MCNPX particle transport code. Neutron brightness metrics were selected as the figure-of-merit. We assumed that STS would use one out of six proton pulses produced by an SNS accelerator upgraded to operate at 1.3 GeV proton energy, 2.8 MW power and 60 Hz repetition rate. The simulations indicate that the peak brightness can be increased by a factor of 5 and 2.5 on a per proton pulse basis compared to the SNS first target station for both coupled and decoupled para-hydrogen moderators, respectively. Additional increases by factors of 3 and 2 were demonstrated for coupled and decoupled moderators, respectively, by reducing the area of neutron emission from 100 × 100 mm{sup 2} to 20 × 20 mm{sup 2}. This increase in brightness has the potential to translate to an increase of beam intensity at the instruments’ sample positions even though the total neutron emission of the smaller moderator is less than that of the larger. This is especially true for instruments with small samples (beam dimensions). The increased fluxes in the STS moderators come at accelerated poison and de-coupler burnout and higher radiation-induced material damage rates per unit power, which overall translate into lower moderator lifetimes. A first effort was undertaken to group decoupled moderators into a cluster collectively positioning them at the peak neutron production zone in the target and having a three-port neutron emission scheme that complements that of a cylindrical coupled moderator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating Data Acquisition, Reduction, and Analysis at the Spallation Neutron Source

ORNL operates the world's brightest neutron source, the Spallation Neutron Source (SNS). Funded by the US DOE Office of Basic Energy Science, this national user facility hosts hundreds of scientists from around the world, providing a platform to enable break-through research in materials science, sustainable energy, and basic science. While the SNS provides scientists with advanced experimental instruments, the deluge of data generated from these instruments represents both a big data challenge and a big data opportunity. For example, instruments at the SNS can now generate multiple millions of neutron events per second providing unprecedented experiment fidelity but leaving the user with a dataset that cannot be processed and analyzed in a timely fashion using legacy techniques. To address this big data challenge, ORNL has developed a near real-time streaming data reduction and analysis infrastructure. The Accelerating Data Acquisition, Reduction, and Analysis (ADARA) system provides a live streaming data infrastructure based on a high-performance publish subscribe system, in situ data reduction, visualization, and analysis tools, and integration with a high-performance computing and data storage infrastructure. ADARA allows users of the SNS instruments to analyze their experiment as it is run and make changes to the experiment in real-time and visualize the results of these changes. In this paper we describe ADARA, provide a high-level architectural overview of the system, and present a set of use-cases and real-world demonstrations of the technology.

Campbell, Stuart I↗

A New 2.5 MeV Injector and Beam Test Facility for the Spallation Neutron Source

The U.S. Spallation Neutron Source (SNS) now operates with 1.2 MW of beam power on target with the near-term goal of delivering 1.4 MW and a longer-term goal of delivering >2 MW to support a planned second target station. Presently, H- beam pulses (50-60 mA, 1 ms, 60 Hz) from an RF-driven, Cs-enhanced, multi-cusp ion source are first accelerated to 2.5 MeV by a Radio Frequency Quadrupole (RFQ) accelerator, injected into a ~1 GeV linac, compressed to <1μs in an accumulator ring and ultimately delivered to a liquid mercury target for pulsed neutron production. In recent years concerns about the RFQ performance has motivated the procurement of a new RFQ and the creation of a Beam Test Facility (BTF) to allow off-line testing. The purpose of the BTF is to first validate performance of the new RFQ before installing it in place of the existing RFQ and later to serve as a stand-alone 2.5 MeV research accelerator employing the original SNS RFQ. After validating the new RFQ with respect to energy, emittance and transmission, the initial applications of the BTF will be to conduct 6D beam dynamic studies, develop & demonstrate ion sources capable of meeting the current and future requirements of the SNS, and contribute to neutron moderator development. This report provides a facility update, description of the BTF ion source systems as well as a discussion of the first LEBT and RFQ beam current measurements performed at the BTF.REFERENCES

Welton, Robert F.↗

Event-based processing of neutron scattering data at the Spallation Neutron Source

Here, the Spallation Neutron Source at Oak Ridge National Laboratory, USA, ushered in a new era of neutron scattering experiments through the use of event-based data. Tagging each neutron event allows pump–probe experiments, measurements with a parameter asynchronous to the source, measurements with continuously varying parameters and novel ways of testing instrument components. This contribution will focus on a few examples. A pulsed magnet has been used to study diffraction under extreme fields. Continuous ramping of temperature is becoming standard on the POWGEN diffractometer. Battery degradation and phase transformations under heat and stress are often studied on the VULCAN diffractometer. Supercooled Al 2 O 3 was studied on NOMAD. A study of a metallic glass through its glass transition was performed on the ARCS spectrometer, and the effect of source variation on chopper stability was studied for the SEQUOIA spectrometer. Besides a summary of these examples, an overview is provided of the hardware and software advances to enable these and many other event-based measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Residual Stress Measurements of Front Window Welds in a Prototypical Spallation Neutron Source Target Module

Spallation Neutron Source (SNS) target modules are fabricated from 316L stainless steel by welding together sections of machined components using electron beam welding. The failure of the tenth operational SNS target (Target 10) at an electron beam weld prompted an investigation into the residual stress remaining in the weld joint after joining to determine if welding procedures for SNS target fabrication produce detrimental residual stresses in or near the welds. Due to an issue with fabrication, the front section of an SNS target was removed from fabrication and made available for residual stress measurements. The residual stresses in an electron beam weld joining the front window and front body of the target prototype was measured at several locations near EBW2 weld between outer window and front body using the VUCLAN instrument. Different stress free d hkl 0 methods were used to calculated the residual strain and residual stress. Furthermore, the results show tensile residual stress up to 350MPa along the weld direction which peaked at weld location.

36 MATERIALS SCIENCE↗

Conceptual Design for Replacement of the DTL and CCL with Superconducting RF Cavities in the Spallation Neutron Source Linac

The Spallation Neutron Source Linac utilizes normal conducting RF cavities in the low energy section from 2.5 MeV to 186 MeV. Six Drift Tube Linac (DTL) structures accelerate the beam to 87 MeV, and four Coupled Cavity Linac (CCL) structures provide further acceleration to 186 MeV. The remainder of the Linac is comprised of 81 superconducting cavities packaged in 23 cryomodules to provide final beam energy of approximately 1 GeV. The superconducting Linac has proven to be substantially more reliable than the normal conducting Linac despite the greater number of stations and the complexity associated with the cryogenic plant and distribution. A conceptual design has been initiated on a replacement of the DTL and CCL with superconducting RF cavities. The motivation, constraints, and conceptual design are presented.

Champion, Mark S↗

Remote Sampling of Failed Spallation Neutron Source Targets

The Spallation Neutron Source (SNS) is a unique high powered particle accelerator-based source of neutrons for research and development purposes. Protons are accelerated into a mercury-filled stainless steel target where they “spall” off neutrons that are then collimated into beams for use in multiple experiments simultaneously. The mercury targets are intended to last up to one year and then must be changed out remotely due to activation by the high intensity proton and neutron beams. In the recent past several of these million dollar targets have failed in a matter of weeks. A team was assembled to acquire samples that could be used for diagnostics of the failures. The team developed a remote sampling tool that was small, economical, simple, easy to use, and could be fabricated and deployed quickly.

Noakes, Mark↗

Electrostatic levitation facility optimized for neutron diffraction studies of high temperature liquids at a spallation neutron source

Neutron diffraction studies of metallic liquids provide valuable information about inherent topological and chemical ordering on multiple length scales as well as insight into dynamical processes at the level of a few atoms. However, there exist very few facilities in the world that allow such studies to be made of reactive metallic liquids in a containerless environment, and these are designed for use at reactor-based neutron sources. We present an electrostatic levitation facility, NESL (for Neutron ElectroStatic Levitator), which takes advantage of the enhanced capabilities and increased neutron flux available at spallation neutron sources (SNSs). NESL enables high quality elastic and inelastic neutron scattering experiments to be made of reactive metallic and other liquids in the equilibrium and supercooled temperature regime. The apparatus is comprised of a high vacuum chamber, external and internal neutron collimation optics, and a sample exchange mechanism that allows up to 30 samples to be processed between chamber openings. Two heating lasers allow excellent sample temperature homogeneity, even for samples approaching 500 mg, and an automated temperature control system allows isothermal measurements to be conducted for times approaching 2 h in the liquid state, with variations in the average sample temperature of less than 0.5%. To demonstrate the capabilities of the facility for elastic scattering studies of liquids, a high quality total structure factor for Zr{sub 64}Ni{sub 36} measured slightly above the liquidus temperature is presented from experiments conducted on the nanoscale-ordered materials diffractometer (NOMAD) beam line at the SNS after only 30 min of acquisition time for a small sample (∼100 mg)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron and Photon Background Measurements at the Spallation Neutron Source Facility - Paper 67

The Spallation Neutron Source facility is a short-pulsed spallation source for condensed matter research using slow neutron scattering. Neutron beams with useful energies ranging from 0.1 meV to 10 eV are brought from a target-moderator-reflector assembly down neutron beamlines to scatter from a variety of materials under study. As of early 2014, SNS routinely provides 1.4 MW (time-averaged) proton power at around 940 MeV to a mercury spallation target at 60 Hz in sub-microsecond pulses. In nearly all cases, the pulsed nature of the neutron source is used, via time-of-flight techniques, to precisely identify the energy of each neutron detected. These neutrons are frequently of such low energy, and consequent slow velocity, that they are not detected until several additional accelerator pulses have taken place. A time-dependent background feature, commonly called the 'prompt pulse,' can contaminate the recorded data. This prompt pulse arises in part from fast and high-energy neutrons and photons produced during the various source reactions, and appears at the same apparent time as the proton pulse striking the target (that is, with negligible time-of-flight delay), often obscuring the data of interest in the individual experiment. We describe here measurements of the fast and high-energy neutron and photon background around the SNS neutron scattering instruments appearing in time with the SNS accelerator pulse structure. Our measurements to date indicate that the liquid scintillator array we have deployed can satisfactorily function in the SNS environment and provide neutron-photon discriminated time/energy spectra of background sources contribution to observed, problematic SNS scattering instrument backgrounds. We will continue measurements and analysis to provide unfolded neutron energy spectra, and through longitudinal studies correlate observed changes in those spectra to external changes at SNS. (authors)

43 PARTICLE ACCELERATORS↗

Spin exchange optical pumping based polarized {sup 3}He filling station for the Hybrid Spectrometer at the Spallation Neutron Source

The Hybrid Spectrometer (HYSPEC) is a new direct geometry spectrometer at the Spallation Neutron Source at the Oak Ridge National Laboratory. This instrument is equipped with polarization analysis capability with 60 Degree-Sign horizontal and 15 Degree-Sign vertical detector coverages. In order to provide wide angle polarization analysis for this instrument, we have designed and built a novel polarized {sup 3}He filling station based on the spin exchange optical pumping method. It is designed to supply polarized {sup 3}He gas to HYSPEC as a neutron polarization analyzer. In addition, the station can optimize the {sup 3}He pressure with respect to the scattered neutron energies. The depolarized {sup 3}He gas in the analyzer can be transferred back to the station to be repolarized. We have constructed the prototype filling station. Preliminary tests have been carried out demonstrating the feasibility of the filling station. Here, we report on the design, construction, and the preliminary results of the prototype filling station.

43 PARTICLE ACCELERATORS↗

Producing persistent, high-current, high-duty-factor H{sup -} beams for routine 1 MW operation of Spallation Neutron Source (invited)

Since 2009, the Spallation Neutron Source (SNS) has been producing neutrons with ion beam powers near 1 MW, which requires the extraction of {approx}50 mA H{sup -} ions from the ion source with a {approx}5% duty factor. The 50 mA are achieved after an initial dose of {approx}3 mg of Cs and heating the Cs collar to {approx}170 deg. C. The 50 mA normally persist for the entire 4-week source service cycles. Fundamental processes are reviewed to elucidate the persistence of the SNS H{sup -} beams without a steady feed of Cs and why the Cs collar temperature may have to be kept near 170 deg. C.

43 PARTICLE ACCELERATORS↗

Deep Learning for Intelligent Bubble Size Detection in the Spallation Neutron Source Visual Target

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) will undergo proton power upgrade (PPU), increasing the proton beam power from 1.4 MW to 2.8 MW. From 2.8 MW, 2.0 MW will go to the current First Target Station and the rest will go to the future Second Target Station (STS). The First Target Station uses a liquid mercury target that is contained in a 316L stainless steel vessel. The proton beam is pulsed at 60 Hz, with a pulse of about 0.7μs. When the proton beam hits the target, the intense energy deposition leads to a rapid rise in temperature in the mercury. This temperature rise creates pressure waves that propagate through the mercury and cause cavitation erosion. The power upgrade will cause stronger pressure waves that will further increase damage because of cavitation. Injecting small helium bubbles in the mercury has been an efficient method of mitigating the pressure wave at 1.4 MW. However, at higher power, additional mitigation is necessary. Therefore, the 2 MW target vessel will be equipped with swirl bubblers and an additional gas injection port near the nose to inject more gas in the target. To develop a gas injection strategy and design, flow visualization in water with a transparent prototypical target (“visual target”) was performed. Bubble sizes and their spatial distribution in the flow loop are crucial to understanding the effectiveness of the bubbles in mitigating pressure waves. Bubbles were generated in the visual target under varied conditions of input pressures with helium and air. Images were captured using a high-speed camera at varied frame rates at different positions away from the swirl bubbler and different depths in the flow loop under varying lighting conditions. Initially, methods such as circular Hough transforms were applied after a series of images processing to obtain a general distribution of bubble sizes. Bubbles smaller than 500 μm are preferred to effectively mitigate the effect of pressure waves, which demands an accurate bubble detection and sizing system. Intelligent detection and identification of bubble sizes alleviate misdetection and improves accuracies. Employing neural networks, intelligent detection of bubble sizes and their distribution was developed and provides a robust alternative to traditional techniques. Human intervention was employed to label in-focus and out-of-focus bubbles in the set of training images. An object detection network using a pretrained convolutional neural network was created that extracted the features from the training images. Data augmentation was used to improve network accuracy through a random transformation of the original data.

Rasheed, Fayaz↗

An apparatus for studying electrical breakdown in liquid helium at 0.4 K and testing electrode materials for the neutron electric dipole moment experiment at the Spallation Neutron Source

In this study, we have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and ~600 Torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of 1–2 cm between them, and a potential up to ±50 kV can be applied to each electrode. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes 12 cm in diameter for a wide range of pressures at 0.4 K. We also measured the current between two electrodes. Our initial results, I < 1 pA at 45 kV, correspond to a lower bound on the effective volume resistivity of liquid helium of ρ V > 5 × 10 18 Ω cm. This lower bound is 5 times larger than the bound previously measured. Finally, we report the design, construction, and operational experience of the apparatus, as well as initial results

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the cesiation process for the spallation neutron source (SNS) H - ion sources

RF-driven (internal and external antenna), Cs-enhanced H - ion sources at the Spallation Neutron Source (SNS) facility are capable of producing high current (>60 mA), high duty-factor (1 ms, 60 Hz) H - beams lasting multiple months. A solid reaction Cs dispenser system is used to cesiate the ion source. This work reports on our continuous effort to optimize the ion source cesiation process guided by the Cs signal observed with the plasma emission spectroscopy to mitigate the Cs induced high voltage sparking while assuring to enable high H - beam currents

Han, Baoxi↗