Solar System Pony Express: Data Mules on Cycler Orbits for High-Latency, Petabit-Scale Data Transfers
No abstract provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract provided
The design of a solar heating and cooling system is documented. Solar collectors, design approaches, system trade studies, and preliminary specifications are discussed.
The software and data base management system required to assess the performance of solar heating and cooling systems installed at multiple sites is presented. The instrumentation data associated with these systems is collected, processed, and presented in a form which supported continuity of performance evaluation across all applications. The CDPS consisted of three major elements: communication interface computer, central data processing computer, and performance evaluation data base. Users of the performance data base were identified, and procedures for operation, and guidelines for software maintenance were outlined. The manual also defined the output capabilities of the CDPS in support of external users of the system.
Design data brochure describes domestic solar water system that uses direct-feed system designed to produce 80 gallons of 140 F hot water per day to meet needs of single family dwelling. Brochure also reviews annual movements of sun relative to earth and explains geographic considerations in collector orientation and sizing.
Low energy cosmic radiation spectrum analysis for IMP 4 data on solar system
A prototype data acquisition system is described. The device characteristics, its performance and the system aspects connected to the integration of the data acquisition system into the space simulator instrumentation and environment are discussed. The data acquisition system has a modular architecture and manifold configuration capability. The input characteristics feature high resolution and accuracy/stability for the measurement of low level (thermocouple originated) analog signals, even in the presence of high common mode and S/N figures. The output is serial digital, compatible with ESA data handling standards. The device is designed to be installed in particularly hostile environments, such as that of a solar simulator.
The accomplishments of a project to study solar heating and air conditioning are outlined. Presentation materials (data packages, slides, charts, and visual aids) were developed. Bibliographies and source materials on materials and coatings, solar water heaters, systems analysis computer models, solar collectors and solar projects were developed. Detailed MIRADS computer formats for primary data parameters were developed and updated. The following data were included: climatic, architectural, topography, heating and cooling equipment, thermal loads, and economics. Data sources in each of these areas were identified as well as solar radiation data stations and instruments.
Results are presented from the analysis of solar-system astrometric data, notably the range data to the Viking landers on Mars. A least-squares fit of the parameters of the solar system model to these data limits a simple time variation in the effective Newtonian gravitational constant to (2 + or - 4) x 10 to the -12th/yr and a rate of drift of atomic clocks relative to the implicit clock of relativistic dynamics to (1 + or - 8) x 10 to the -12th/yr. The error limits quoted are the result of uncertainties in the masses of the asteroids.
The paper describes a computer-operated image-scanning and data-collection system for the magnetograph at the Mt. Wilson 150-foot Tower telescope. The system is based on a minicomputer with a 32K word core memory and a generalized interface unit for controlling image motion, a keyboard, and an associated television screen. Operation of the solar image guider and the data-collection assembly is outlined along with the observation and data-reduction procedures. Advantages of the system include the ability to move the image in almost any conceivable fashion, a wide choice of integration times, and increased accuracy in magnetic and Doppler calibrations as well as in setting of the magnetic zero level.
The Site Data Acquisition Subsystem (SDAS) designed to collect data from sensors located on residential or commercial buildings using a solar heating and/or cooling system is described. It takes the data obtained from sensors located on the solar system, processes the data into suitable format, stores the data for a period of time, and provides the capability for either telephone retrieval by the central data processing system or manual retrieval of the data for transfer to a central site. The SDAS is also designed so that it will not degrade the operation of the solar heating/cooling system which it is monitoring.
The Synchronous Meteorological Satellite (SMS) system is described which is being utilized in a program to obtain day and night information on the earth's weather by means of earth imaging, retransmission of imaged data, meteorological data collection and relay, and space environment monitoring. The components and functions of the ground system are discussed together with the basic satellite payloads. The launch and orbit of SMS-A are reviewed, and the functions of the visible IR spin-scan radiometer are described in detail. Other systems and units discussed include the data collection system, solar environment monitor, weather-facsimile unit, and central data distribution system. It is noted that SMS-A was used to support the Global Atlantic Tropical Experiment and that the SMS system will be complemented by geostationary environmental satellites from ESRO, Japan, and the USSR.
The solar heating and hot water system installed at the William Tao & Associates, Inc., office building in St. Louis, Missouri is described, including maintenance and construction problems, final drawings, system requirements, and manufacturer's component data. The solar system was designed to provide 50 percent of the hot water requirements and 45 percent of the space heating needs for a 900 sq ft office space and drafting room. The solar facility has 252 sq ft of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.
Versatile automatic system collects data from wind and solar energy sensors. System allows changes in data types, number of channels, sensor location and speed of recording.
The most significant data on fields and plasmas in the outer solar system, based on observations by Pioneer 10 and 11, are reviewed. Attention is given to (1) corotating shocks and the evolution of high speed solar wind streams, (2) the effect of the changing structure of the interplanetary medium on energetic particles, (3) the propagation of flare-generated shocks through the outer solar system, (4) radial gradients in the solar wind and interplanetary field, and (5) the dependence of the interplanetary sector structure on heliographic latitude.
The ratios Ne-22/Ne-20 and Mg-26/Mg-24 were measured in galactic cosmic rays by the IMP-7 satellite in the 60 to 230 MeV/nucleon range. The neon cosmic ray source ratio Ne-22/Ne-20 is about 0.38, which is much larger than the current solar system relationship; the Mg data agrees with the solar system isotopic ratio of 0.14 at the cosmic ray source. The Ne and Mg source ratios are explained by supernova models, and become a new constraint which should be satisfied by any model of cosmic ray origin.
The DDS SDOGS Integration Manager (DSIM) provides translation between native control and status formats for systems within DDS and SDOGS, and the ASIST (Advanced Spacecraft Integration and System Test) control environment in the SDO MOC (Solar Dynamics Observatory Mission Operations Center). This system was created in response for a need to centralize remote monitor and control of SDO Ground Station equipments using ASIST control environment in SDO MOC, and to have configurable table definition for equipment. It provides translation of status and monitoring information from the native systems into ASIST-readable format to display on pages in the MOC. The manager is lightweight, user friendly, and efficient. It allows data trending, correlation, and storing. It allows using ASIST as common interface for remote monitor and control of heterogeneous equipments. It also provides failover capability to back up machines.
Explore the source record for details and available documents.
A design calculation is detailed for a single-family residence housing a family of four in a nonspecific geographical area. The solar water heater system is designed to provide 80 gallons of 140 F hot water per day.