Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Profiling the Usage of an Extreme-Scale Archival Storage System

Profiling the archival storage system in scientific computing environments has received much less attention compared to the parallel file system, but is equally important since it stores the final data products safely, for a long duration. In this paper, we analyze eight years worth of data transfer logs for accessing the archival file system (HPSS) in the Oak Ridge Leadership Computing Facility (OLCF), which has been hosting the world's largest supercomputers and file systems. Our analysis encompasses about 135 million data transfer activities to the 80 PB High Performance Storage System (HPSS), between 2010 and 2017. We analyze the logs from several dimensions, including studying the workload characteristics (e.g., access patterns, frequency of accesses and temporal behavior), file system characteristics (e.g., directory depth, file system scaling trends, file types), and scientific user behavior (e.g., domain-specific usage and organization). Based on the analysis, we derive insights into the future evolution of the archive in terms of provisioning, desired features and functionality from the archive software, role and right sizing of the archive tiers, quota management, and the importance of smart and efficient metadata and storage management. We believe our study will prove useful for both operating current archival storage and better provisioning future systems.

Sim, Hyogi↗

Temperature Dependent Raman Spectroscopic Study of the Fe Doped La{sub 0.67}Sr{sub 0.33}MnO{sub 3} Prepared Using Ball Milling Method

Polycrystalline samples of La{sub 0.67}Sr{sub 0.33}Mn{sub 0.65}Fe{sub 0.35}O{sub 3} (LSMFO) were synthesized using the standard ball mill method with different calcination temperatures ranging from 800 to 1100°C for 7 h. The phase purity of these samples was confirmed using X-ray diffraction (XRD) patterns. All samples were found to have rhombohedral crystal structure with R 3-bar c space group. The lattice parameters, cell volume, bond angle and bond length have been obtained using the Rietveld refinement by FullProf software. The average crystallite size calculated using the Debye-Scherrer formula was found between 27 and 60 nm. Surface morphology of the prepared samples has been examined using a scanning electron microscope (SEM). SEM images show the formation of well-arranged grain sizes distributed from 240 to 400 nm, much larger than one estimated using the Scherrer formula. All tiny particles are highly agglomerated with the increasing temperature and porosity decreases with increasing temperature. An analysis of the frequency and peak broadening of Raman modes as a function of temperature clearly shows the significant temperature effect on the A{sub 1g} and E{sub g} modes of LSMFO. The shifts and broadening of the A{sub 1g} and E{sub g} modes are discussed in light of the oxygen sublattice distortion. Our study shows the reduction in distortion with increasing calcination temperature, which suggests a decrease in the JT effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

GeneratorSE.jl

SAND2026-22941O GeneratorSE.jl is a Julia software package for analytical sizing of variable-speed wind turbine generators. It translates and maintains generator sizing methods from the NREL WISDEM GeneratorSE framework in a Julia package form. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Michelen Strofer, Carlos [Sandia National Lab. (SN↗

Sandia Particle Holography Processor v. 1.0

HoloSand is a suite of MATLAB® functions for measurement of particle properties from digital holograms. Functions to read and display digital holograms are included along with scripts to extract three-dimensional particle positions, sizes, and velocities. This software is a research tool used to process experimental data. A user of this software would first record digital holograms of a particle field and then use this software to measure the three-dimensional particle information encoded in the hologram. Applications range from basic laboratory fluids research to applied particle measurements. The software has no known military applications. The software solves the diffraction integral equation to numerically refocus digital holograms and then applies the hybrid and cross-correlation methods described in the references to extract three-dimensional particle information. User input is required to read-in the hologram and select optimum settings for image segmentation.

Guildenbecher, Daniel↗

High Resolution Scanning Configurations for the Canberra Tomographic Gamma Scanner - 17323

The Canberra Tomographic Gamma Scanner (TGS) is a Non-Destructive Assay (NDA) system that combines high resolution gamma ray spectroscopy (HRGS) with low-spatial-resolution imaging for the measurement of heterogeneous drummed waste with matrix densities in the range of 0 to 1 g/cc. The TGS methodology uses a two-pass scanning protocol; a 10-15 μCi {sup 152}Eu transmission source is used to interrogate density and composition of the matrix in the first pass, and passive gamma ray spectroscopy is used to collect emission spectra in the second, while the drum is rotated and translated to vary the view path. In standard implementations, the transmission and emission data are used to reconstruct three dimensional images of the matrix and activity distribution inside the drum on a 10x10x16 grid of discrete volume elements or 'voxels'. These images allow attenuation corrections to be calculated and applied on a view by view, and voxel by voxel basis, reducing the over- and under-correction biases obtained by assay techniques which assume homogeneous distributions of material. The most recent TGS system deployed by Canberra featured, among other new developments, the ability to perform higher resolution image re-construction, which may prove beneficial for the assay of more highly mixed matrices or oddly shaped assay items within a container. These additional scanning protocols reconstruct the image data into 14x14 and 20x20 voxel grids, using a smaller collimator aperture size. The hardware and software implementations of these higher resolution scans are discussed, and the calibration and initial evaluations of performance are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

recon3d

SAND2025-00533O recon3d is a software tool that provides automated 3D reconstruction and meshing capabilities. It processes labeled 3D image data from various sources, starting from image stacks, and calculates 3D feature distributions like size, shape, and location. The software also has tools for downscaling rectilinear grid data and creating tetrahedral meshes directly from image data. recon3d can be used by novice users via the command line with a properly formatted configuration file. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Emery, John↗

SPLAT II: An Aircraft Compatible, Ultra-Sensitive, High Precision Instrument for In-Situ Characterization of the Size and Composition of Fine and Ultrafine Particles

The properties of aerosols depend on the size and internal compositions of the individual particles. The vast majority of atmospheric aerosols are smaller than 200 nm, yet the single particle mass spectrometers, the only instruments that can characterize the size and internal compositions of individual particles, typically detect these small particles with extremely low efficiencies. In this paper we describe a new instrument called SPLAT II that provides unparalleled sensitivity to small particles, detecting 100% of particles that are larger than 125 nm and 40% of 100 nm particles. This instrument also brings an increase by a factor of 10 in temporal resolution, sizing up to 500 particles per second and characterizing the composition of up to 100 of them. SPLAT II uses a two-laser, two-step process to evaporate the particles and generate ions, producing high quality, reproducible mass spectra of the refractive and non-refractive aerosol fractions to yield the complete compositions of individual particles. The instrument control board provides for size dependent delays for lasers’ triggers to eliminate a size dependent hit rate. The mass spectra are recorded with 14-bit vertical resolution and analyzed using custom software packages. The instrument’s high sizing resolution and sensitivity makes it possible to combine it with the differential mobility analyzer(s) and measure particle size, composition, density, dynamic shape factor, hygroscopicity, and fractal dimension.

47 OTHER INSTRUMENTATION↗

The sizes of z ∼ 6–8 lensed galaxies from the Hubble Frontier Fields Abell 2744 data

We investigate the sizes of z ∼ 6–8 dropout galaxies using the complete data of the Abell 2744 cluster and parallel fields in the Hubble Frontier Fields program. By directly fitting light profiles of observed galaxies with lensing-distorted Sérsic profiles on the image plane with the glafic software, we accurately measure intrinsic sizes of 31 z ∼ 6–7 and 8 z∼8 galaxies, including those as faint as M{sub UV}≃−16.6. We find that half-light radii r{sub e} positively correlates with UV luminosity at each redshift, although the correlation is not very tight. The largest (r{sub e}>0.8 kpc) galaxies are mostly red in UV color while the smallest (r{sub e}<0.08 kpc) ones tend to be blue. We also find that galaxies with multiple cores tend to be brighter. Combined with previous results at 2.5≲z≲12, our result confirms that the average r{sub e} of bright ((0.3–1)L{sub z=3}{sup ∗}) galaxies scales as r{sub e}∝(1+z){sup −m} with m=1.24±0.1. We find that the ratio of r{sub e} to virial radius is virtually constant at 3.3 ± 0.1% over a wide redshift range, where the virial radii of hosting dark matter halos are derived based on the abundance matching. This constant ratio is consistent with the disk formation model by Mo et al. with j{sub d}∼m{sub d}, where j{sub d} and m{sub d} are the fractions of the angular momentum and mass within halos confined in the disks. A comparison with various types of local galaxies indicates that our galaxies are most similar to circumnuclear star-forming regions of barred galaxies in the sense that a sizable amount of stars are forming in a very small area.

79 ASTRONOMY AND ASTROPHYSICS↗

N-S3 Cellular Vehicle-to-Everything (C-V2X) Cosimulation Framework [SWR-24-54]

This is a vehicular networking simulator designed to enable synchronized network simulation with vehicle traffic simulation software. The communications model is based on the 3GPP LTE-V2X Mode 4 protocol, but includes several other wireless network protocol models as well. This simulator includes both a V2X network simulation implemented in ns-3 as well as an interface to automatically configure, run, and interact with a set of ns-3 instances based on network size and available hardware. This software has been tested with Aimsun NEXT 2.0 simulator (with V2X SDK), but uses a generic interface for compatibility with any comparable vehicle traffic simulator across the HELICS co-simulation framework. This software is intended as a generalized extension to vehicle traffic simulation, and does not model any vehicle traffic on its own.

Wang, Qichao↗

Updimensioning strategy derived from synthetic equiaxed grain structures for approximating 3D grain size distributions from 2D visualizations with 1D parameters

We generated synthetic equiaxed grain structures using computer graphics software to explore the relationship between various grain size determination methods and true three-dimensional (3D) grain diameters. Mirroring grain measurement techniques, the synthetic 3D grain structures are imaged as 2D micrographs which are measured to yield 1D grain size parameters. Synthetic grain structures provide data at a mass scale and permit exploration of both polished and fractured surface micrographs, revealing one-to-one correspondence between exposed 2D grain cross-sections and individual 3D grains. Analysis of this correspondence yielded a procedure to approximate 3D equiaxed grain size and volume distributions based on the mode of the 2D fractograph grain size distribution. The 3D approximation procedure is shown to be less susceptible to different imaging conditions that affect small, undiscernible grains compared to the standard planimetric and linear intercept methods, which by design also tend to underestimate the 3D grain diameter. The procedure requires larger sample sizes to lower variance and a deeper analysis which could become more practical with machine learning (ML) models for grain boundary segmentation, which synthetic grain structures can help train. This work lays the foundation for analyzing other grain distributions such as columnar and composite grains in similar depth.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-348: Verification MU Calculation for Conformal Radiotherapy with Multileaf Collimator Using Report AAPM TG 114

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for 3D conformal radiotherapy with multileaf high and low resolution according to the report of AAPM TG 11 Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS. A 6MV photon beam produced by Primus and Novalis linear accelerators equipped with an Optifocus MLC and HDMLC, respectively. TPS dose calculation algorithms were pencil beam and Monte Carlo. 1082 treatments plans were selected for the study. The algorithm was written in free and open source CodeBlocks C++ platform. Treatment plans were imported by the software using RTP format. Equivalent size field is obtained from the positions of the leaves; the effective depth of calculation can be introduced by TPS's dosimetry report or automatically calculated starting from SSD. The inverse square law is calculated by the 3D coordinates of the isocenter and normalization point of the treatment plan. The dosimetric parameters TPR, Sc, Sp and WF are linearly interpolated. Results: 1082 plans of both machines were analyzed. The average uncertainty between the TPS and the independent calculation was −0.43% ± 2.42% [−7.90%, 7.50%]. Specifically for the Primus the variation obtained was −0.85% ± 2.53% and for the Novalis 0.00% ± 2.23%. Data show that 94.8% of the cases the uncertainty was less than or equal to 5%, while 98.9% is less than or equal to 6%. Conclusion: The developed software is appropriate for use in calculation of UM. This software can be obtained upon request.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

The Effect of the Ill-posed Problem on Quantitative Error Assessment in Digital Image Correlation

Here, this work explores the effect of the ill-posed problem on uncertainty quantification for motion estimation using digital image correlation (DIC) (Sutton et al. 2009). We develop a correction factor for standard uncertainty estimates based on the cosine of the angle between the true motion and the image gradients, in an integral sense over a subregion of the image. This correction factor accounts for variability in the DIC solution previously unaccounted for when considering only image noise, interpolation bias, contrast, and the software settings such as subset size and spacing.

97 MATHEMATICS AND COMPUTING↗

Experimental Investigation on Metallic Droplet Behavior in Molten BOF Slag

In order to better understand the metallic droplet behavior during a slag treatment process, a physical modeling based on the similarity principle was performed in a transparent scaled-down vessel at room temperature. Paraffin oil, 20 wt pct copper sulfate solution, and compressed air were used to simulate the molten slag, metallic droplet, and carrier gas, respectively. The droplets injected into paraffin oil during the experiment were captured by a high speed camera and were analyzed by Image Pro Plus software to obtain the droplet size distribution. The critical droplet size in the physical modeling and slag treatment process is quantitatively correlated. The results show that droplet breakage phenomenon is dominant over its coalescence in the current industrial practice, and droplet breakage is enhanced with increasing gas flow rate and/or lance depth. No significant effect of the nozzle configuration was found on the droplet breakage and coalescence. The droplet size distribution varies with the lance position. Gas flow rate and lance depth are the most important factors for droplet breakage, the extent of which can be reduced through a proper selection of the operational conditions. A linear relationship between the droplet size and the input energy flux is obtained.

36 MATERIALS SCIENCE↗

Multi-institutional Feasibility Study of a Fast Patient Localization Method in Total Marrow Irradiation With Helical Tomotherapy: A Global Health Initiative by the International Consortium of Total Marrow Irradiation

Purpose: To develop, characterize, and implement a fast patient localization method for total marrow irradiation. Methods and Materials: Topographic images were acquired using megavoltage computed tomography (MVCT) detector data by delivering static orthogonal beams while the couch traversed through the gantry. Geometric and detector response corrections were performed to generate a megavoltage topogram (MVtopo). We also generated kilovoltage topograms (kVtopo) from the projection data of 3-dimensional CT images to reproduce the same geometry as helical tomotherapy. The MVtopo imaging dose and the optimal image acquisition parameters were investigated. A multi-institutional phantom study was performed to verify the image registration uncertainty. Forty-five MVtopo images were acquired and analyzed with in-house image registration software. Results: The smallest jaw size (front and backup jaws of 0) provided the best image contrast and longitudinal resolution. Couch velocity did not affect the image quality or geometric accuracy. The MVtopo dose was less than the MVCT dose. The image registration uncertainty from the multi-institutional study was within 2.8 mm. In patient localization, the differences in calculated couch shift between the registration with MVtopo-kVtopo and MVCT-kVCT images in lateral, cranial–caudal, and vertical directions were 2.2 ± 1.7 mm, 2.6 ± 1.4 mm, and 2.7 ± 1.1 mm, respectively. The imaging time in MVtopo acquisition at the couch speed of 3 cm/s was <1 minute, compared with ≥15 minutes in MVCT for all patients. Conclusion: Whole-body MVtopo imaging could be an effective alternative to time-consuming MVCT for total marrow irradiation patient localization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a portable mechanical hysteresis measurement and imaging system for impact characterization in honeycomb sandwich structures

Honeycomb sandwich materials are commonly used for aero-structures, but because the outer skins are typically thin, 2-10 plys, the structures are susceptible to impact damage. NDI methods such as tap tests, bond testers and TTU ultrasound are successfully deployed to find impact damage, but identifying the type/degree of damage is troublesome. As the type/degree of impact damage guides decisions by the maintenance, repair and overhaul (MRO) community regarding repair, the ability to characterize impacts is of interest. Previous work demonstrated that additional impact characterization may be gleaned from hysteresis loop area, as determined from an out-of-plane load-vs-displacement plot, where this parameter shows a correlation with impact energy. This presentation reports on current work involving the development of a portable hysteresis measurement and imaging system based on an instrumented tapper. Data processing and analysis methods that allow production of the load/displacement data from a single accelerometer are discussed, with additional reporting of tests of software to automatically vary pixel size during scanning to decrease C-scans inspection time.

36 MATERIALS SCIENCE↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗