Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft X-ray imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

X-ray observations of the North Polar Spur

The X-ray enhancement associated with the North Polar Spur (Radio Loop I) was observed by a soft X-ray instrument on OSO 8 during August 1975. This paper presents image-processed maps of the region scanned, a detailed analysis of the X-ray data, and interpretations of the data in terms of supernova remnant models. If the neutral hydrogen ridge, radio continuum ridge, and X-ray emission ridge are all associated, then they cannot all be fitted by a single supernova remnant model because they require different energies of explosion. A reheated supernova remnant model does appear compatible with all the available observations.

Iwan, D.↗

Results from the central Hyades survey

Results of a soft X-ray survey of the central 5 deg of the Hyades star cluster made with the Einstein Observatory Imaging Proportional Counter are presented. Virtually all of the late F and early G stars in the cluster were detected at an X-ray luminosity of greater than 10 to the 28.5 erg/sec, although only about 50% of the stars in the cluster as a whole were detected. Plots of X-ray luminosity against B-V index indicate that the typical solar-type star in the Hyades is emitting soft X-rays at a level approximately 30 times that of the active sun. Histograms of the X-ray to bolometric luminosity ratio reveal a gradual distinction between late A-early F stars, which are expected to possess little or no convective envelope, and solar-type (F8-G5) stars, with convective outer atmospheres. Results confirm the dependence of stellar coronal activity on rotation, and establish the prevalence of stellar coronae throughout the main sequence and the giant regions of the H-R diagram.

Stern, R. A.↗

Multi-anode microchannel arrays

The Multi-Anode Microchannel Arrays (MAMA's) are a family of photoelectric, photon-counting array detectors being developed for use in instruments on both ground-based and space-borne telescopes. These detectors combine high sensitivity and photometric stability with a high-resolution imaging capability. MAMA detectors can be operated in a windowless configuration at extreme-ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. Prototype MAMA detectors with up to 512 x 512 pixels are now being tested in the laboratory and telescope operation of a simple (10 x 10)-pixel visible-light detector has been initiated. The construction and modes-of-operation of the MAMA detectors are briefly described and performance data are presented.

Timothy, J. G.↗

S056 X-ray telescope experiment on the Skylab Apollo Telescope Mount

This paper describes the S056 X-ray instrument which was carried aboard the Skylab Apollo Telescope Mount as part of the solar instrument cluster. The instrument, which was built at the NASA Marshall Space Flight Center, consisted of a glancing incidence X-ray telescope to record solar images in the 6-40-A region, together with an X-ray event analyzer to monitor the total solar soft X-ray flux in several wavelength bands. The X-ray telescope used film as a recording medium and thin foil filters to isolate specific wavelength bands. The instrument subsystems are described in detail and typical results presented.

Underwood, J. H.↗

Image Data Processing System (IDAPS) user manual, S-056 experiment. Volume 1: System description. Volume 2: Batch IDAPS. Volume 3: Interactive IDAPS

Image data processing system (IDAPS) developed to satisfy the image processing requirements of the Skylab S-056 experiment is described. The S-056 experiment was designed to obtain high-resolution photographs of the sun in the far ultraviolet, or soft X-ray, portion of the electromagnetic spectrum. Thirty-five thousand photographs were obtained by the three flights of the program; and, faced with such a massive volume of imagery, the designers of the experiment decided to develop a computer-based system which would reduce the image processing workload. The purpose of the IDAPS User Manual is to give the IDAPS user the necessary information and instructions to effectively utilize the system.

Source record↗

Glancing incidence telescope for far ultraviolet and soft X-rays

Glancing-incidence telescope makes observations of distant celestial radiant bodies at wavelengths in the spectral region between 3 and 500 angstroms. The device can be used as a fore-optics system for a laboratory extreme ultraviolet spectrometer, or for the collection or imaging of thermal neutrons.

Neupert, W. M.↗

X-ray scattering study

A soft X-ray glancing incidence telescope mirror and a group of twelve optical flat samples were used to study the scattering of X-rays. The mirror was made of Kanigen coated beryllium and the images produced were severely limited by scattering of X-rays. The best resolution attained was about fifteen arc seconds. The telescope efficiency was found to be 0.0006. The X-ray beam reflected from the twelve optical flat samples was analyzed by means of a long vacuum system of special design for these tests. The scattering then decreased with increasing angle of incidence until a critical angle was passed. At larger angles the scattering increased again. The samples all scattered more at 44 A than at 8 A. Metal samples were found to have about the same scattering at 44 A but greater scattering at 8 A than glass samples.

Wriston, R. S.↗

Optical and X-ray properties of the newly discovered BL Lacertae object PKS 2155-304 /= H2155-304/

The soft X-ray source H 2155-304 has been precisely located with the HEAO 1 scanning modulation collimator, and identified with an object of bolometric magnitude approximately 14. The linear polarization, variability, spectrum, and diffuse image of the optical flux, together with the positional coincidence of the radio source PKS 2155-304, indicate that this object is a new member of the BL Lacertae class. Its characteristics are compared with those of other X-ray-emitting BL Lacertae objects, particularly Mrk 421.

Griffiths, R. E.↗

Transmission ultrasonography

Review of the results of the application of an advanced signal-processing technique, called time delay spectrometry, in obtaining soft tissue transmission images by transmission ultrasonography, both in vivo and in vitro. The presented results include amplitude ultrasound pictures and phase ultrasound pictures obtained by this technique. While amplitude ultrasonographs of tissue are closely analogous to X-ray pictures in that differential absorption is imaged, phase ultrasonographs represent an entirely new source of information based on differential time of propagation. Thus, a new source of information is made available for detailed analysis.

Heyser, R. C.↗

Iodine imaging using spectral analysis

Existing radiographic imaging systems provide images which represent an integration or averaging over the energy spectrum. In order to provide noninvasive angiography it is necessary to image the relatively small amounts of iodine which are available following an intravenous administration. This is accomplished by making use of the special spectral characteristics of iodine. Two methods will be presented. One involves a special grating for encoding the iodine information in the form of a fine line pattern. This is subsequently decoded to provide images of iodinated structures which are otherwise almost invisible. The second method utilizes a scanned X-ray beam which is rapidly switched in the high energy region. In this region, iodine experiences significant variations in the attenuation coefficient while bone and soft tissue do not. An efficient and accurate X-ray detector can be used with scanned X-ray beams. This provides a high degree of sensitivity enabling the visualization of small vessels containing relatively dilute iodine.

Macovski, A.↗

Fabrication of a focusing soft X-ray collector payload

A large area X-ray focusing collector with arc minute resolution and a position sensitive detector capable of operating in the soft X-ray region was developed for use on sounding rockets in studying stellar X-ray sources. The focusing payload consists of the following components, which are described: (1) a crossed paraboloid mirror assembly; (2) an aspect camera and star tracker; (3) a focal plane assembly containing an imaging proportional counter and its preamplifiers, high voltage power supplies and gas system; (4) a fiducial system; and (5) housekeeping, data handling, instrumentation and telemetry electronics. The design, tests, and operation are described.

Davis, J. M.↗

Photon-counting detector arrays based on microchannel array plates

The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

Timothy, J. G.↗

Observation of soft X-ray emission from the supernova remnant HB9

The number of known X-ray emitting supernova remnants in our galaxy has significantly grown as a result of the soft X-ray survey by the HEAO-1 spacecraft. The HEAO-1 A-2 experiment has observed soft X-ray emission from the old supernova remnant HB9 which lies close to the previously identified X-ray source, Capella. Spectral data and the low optical obscuration in the direction of the remnant suggest that HB9 is a good candidate for detecting Fe XIV coronal forbidden-line emission. Mapping of the coronal line emission in association with the imaging X-ray data expected from HEAO-2 would allow the temperature profile of the emitting shell to be determined in a manner similar to that used by Tuohy, Nousek, and Garmire (1979) for the Cygnus Loop, which is in a similar evolutionary phase to HB9.

Tuohy, I. R.↗

Study of X-ray optics

The testing is reported of a polished Kanigen coated beryllium mirror in a soft X-ray telescope to be flown on a Skylark sounding rocket. This test involved inserting the telescope in a 220 foot long vacuum line and taking photographs of an X-ray resolution source. These photographs were then used to evaluate the performance of the telescope mirror as a function of distance from the focal plane and the angular distance off the telescope axis. A second test was made in which a point source was used to study the imaging characteristics by means of a pinhole and proportional counter placed in the telescope focal plane. A third test was conducted using a position sensitive detector. The efficiency and resolution was increased by polishing.

Froechtenigt, J. F.↗

Rocket studies of solar corona and transition region

The XSST (X-Ray Spectrometer/Spectrograph Telescope) rocket payload launched by a Nike Boosted Black Brant was designed to provide high spectral resolution coronal soft X-ray line information on a spectrographic plate, as well as time resolved photo-electric records of pre-selected lines and spectral regions. This spectral data is obtained from a 1 x 10 arc second solar region defined by the paraboloidal telescope of the XSST. The transition region camera provided full disc images in selected spectral intervals originating in lower temperature zones than the emitting regions accessible to the XSST. A H-alpha camera system allowed referencing the measurements to the chromospheric temperatures and altitudes. Payload flight and recovery information is provided along with X-ray photoelectric and UV flight data, transition camera results and a summary of the anomalies encountered. Instrument mechanical stability and spectrometer pointing direction are also examined.

Acton, L. W.↗

X-ray studies of quasars and active galaxies with the Einstein Observatory

Preliminary results of the first six months of an X-ray survey of active galaxies and quasars performed with the imaging proportional counter on board the Einstein Observatory are presented. Consideration is given to detections of Seyfert galaxies, N galaxies, BL Lac objects and quasars, and properties of selected representative objects are discussed in detail. The statistical properties, including class averages and correlation coefficients, of the various X-ray active galaxies are calculated in an attempt to determine the relation of X-ray properties to the similarities and differences between the various classes of galaxies. Evidence is obtained for a continuity of high-energy behavior among all active galaxies, and it is noted that they all exhibit flux variability, often on a short time scale. The soft X-ray emission can be explained in terms of the synchrotron self-Compton model, or alternatively by thermal emission from hot gas. A significant correlation is obtained between the X-ray and optical fluxes for all objects considered, indicating that optical quasar counts may be used to infer the contribution of quasars to the diffuse X-ray background.

Ku, W. H.-M.↗

X-ray properties of quasars

The X-ray properties of 111 catalogued quasars have been examined with the imaging proportional counter on board the Einstein Observatory. Thirty-five of the objects, of redshift between 0.064 and 3.53, were detected as X-ray sources. The 0.5-4.5-keV X-ray properties of these quasars are correlated with their optical and radio continuum properties and with their redshifts and variability characteristics. The X-ray luminosity of quasars tends to be highest for those objects which are bright in the optical and radio regimes and which exhibit optically violent variability. These observations suggest that quasars should be divided into two classes on the basis of radio luminosities, spectra, evolution and underlying morphology and that quasars can make up a significant portion of the diffuse soft X-ray background only if the slope of the optical quasar log N-log S relation is steeper than 2 to m sub b of about 21.5.

Ku, W. H.-M.↗

Quantitative micro-luminescence and related studies of fine and/or glassy lunar surface materials

Papers on Raman and soft X-ray spectroscopy of lunar glasses and electron microscopy of lunar fines are presented. Individual particles of glasses from Apollo 11, 12, 14, and 15 samples were analyzed separately. Silicon emission shifts vary between parent rock types and can be interpreted as a range of Si-O distances from 1.612 to 1.637 A. Aluminum emission shifts relate to the amount of 4- and 6-coordinated Al in the glass. Raman spectra show broadened bands. Certain bands recur in many specimens and relate to the main normative minerals for the glass bulk composition, olivine, pyroxene, and anorthite. Quantitative size and shape analyses were carried out on six Apollo 14 and 15 samples of fines by computer evaluation of scanning electron microspace images. For the size range of 0.50 to 30 micron diameter, the distributions are log-normal on a number count basis. Aspect ratios range from 0.1 to 1.0 with an average value of about 0.6. The aspect ratios and a shape complexity factor vary only slightly among the samples.

Roy, R.↗