Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft X-ray detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

Sealed position sensitive hard X-ray detector having large drift region for all sky camera with high angular resolution

A sealed position sensitive proportional counter filled with two atmospheres of 95% xenon and 5% methane, and containing a drift region of 24 atm cm, has operated in a stable manner for many months. The detector contains G-10 frames to support the anode and cathode wires. The detector was sealed successfully by a combination of vacuum baking the G-10 frames at 150 C for two weeks followed by assembly into the detector in an environment of dry nitrogen, and the use of passive internal getters. The counter is intended for use with a circumferential cylindrical collimator. Together they provide a very broad field of view detection system with the ability to locate cosmic hard X-ray and soft gamma ray sources to an angular precision of a minute of arc. A set of instruments based on this principle have been proposed for satellites to detect and precisely locate cosmic gamma ray bursts.

Gorenstein, P.↗

Determination of the structure and heating mechanisms of coronal loops from soft X-ray observations with the solar probe

High resolution soft X-ray imaging from the solar probe is justified in terms of the expected scientific returns which include the determination of the temperature and density structure of a coronal loop. The advantages of the grazing incidence telescope over the multiple pinhole camera are discussed. An instrument package is described which includes a grazing incidence mirror, a thermal prefilter, a three position filter wheel and a focal plane detector baselined as an 800 by 800 back-illuminated charge coupled device. The structural assembly together with the data processing equipment would draw heavily on the designs being developed for the Solar Polar Mission.

Davis, J. M.↗

Introducing new resonant soft x-ray scattering capability in SSRL

Resonant soft x-ray scattering (RSXS) is a powerful technique for probing both spatial and electronic structures within solid-state systems. Here, we present a newly developed RSXS capability at beamline 13-3 of the Stanford Synchrotron Radiation Lightsource, designed to enhance materials science research. This advanced setup achieves a base sample temperature as low as 9.8 K combined with extensive angular motions (azimuthal ϕ and flipping χ), enabling comprehensive exploration of reciprocal space. Two types of detectors—an Au/GaAsP Schottky photodiode and a charge-coupled device detector with over 95% quantum efficiency—are integrated to effectively capture scattered photons. Extensive testing has confirmed the enhanced functionality of this RSXS setup, including its temperature and angular performance. The versatility and effectiveness of the system have been demonstrated through studies of various materials, including superlattice heterostructures and high-temperature superconductors.

Kuo, Cheng-Tai [SLAC National Accelerator Laborato↗

Mapping of electrical potential distribution with charged particle beams

Potentials were measured using a beam of soft X-rays in air at 2 x 10 to the -5 power Torr. Ions were detected by a continuous-dynode electron multiplier after they passed through a retarding field. Ultimate resolution depends upon the diameter of the X-ray beam which was 3 mm. When the fields in the region of interest were such to disperse the ions, only a small fraction were detected and the method of measurement was not very reliable. Yet reasonable data could be collected if the ions traveled in parallel paths toward the detector. Development should concentrate on increasing the aperture of the detector from the pinhole which was used to something measured in centimeters. Also increasing the strength of the source would provide a stronger signal and more reliable data. Measurements were made at an estimated ion current to 10 to the -15 power A from a 10 cm length of the X-ray beam, this current being several orders of magnitude below what would have a perturbing effect on the region to be measured. Consequently, the source strength can be increased and prospects for this method of measurement are good.

Robinson, J. W.↗

A ten-day observation of Hercules X-1 from the OSO-7 satellite

The MIT X-ray detectors aboard the OSO-7 spacecraft viewed Hercules X-1 from November 14 to 24, 1972. X-ray turn-on in the 35-day cycle was observed to occur between phases 0.67 and 0.70 (November 18.64-18.70). A significant decrease in the X-ray intensity occurred near mid-orbital phase, approximately 1.5 days after X-ray turn-on. Using the 1-6 keV data obtained during the 35-day off state, we conclude that if the optical light curve is due to heating of the large star by a blackbody source of soft X-rays, then the source must be large (radius greater than 5,000 km) and cool (temperature (kT) less than 90 eV). During one eclipse period (November 20.8-21.0) we find evidence for 1-6 keV X-ray emission.

Mcclintock, J. E.↗

Instrumentation for solar spectrophotometry at extreme ultraviolet and soft X-ray wavelengths

The solar extreme ultraviolet and soft X-ray (XUV) spectrum at wavelengths between 20 and 300 A contains a wealth of emission lines from ions formed at temperatures from 10 to the 5th K to greater than 2 x 10 to the 7th K. The requirements for high resolution spectrophotometric instrumentation are discussed in the light of data obtained with extreme ultraviolet and X-ray telescopes flown on Skylab. The design of a grazing-incidence spectroheliometer for active region and flare studies over the wavelength range from 40 to 630 A is presented and recently developed high-efficiency detectors and detector-arrays for use at XUV wavelengths are described.

Timothy, J. G.↗

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

Extreme-ultraviolet observations of dwarf novae from Apollo-Soyuz

The paper reports on EUV observations of four dwarf novae (SS Cyg, Z Cha, VW Hyi, and AE Aqr) in July 1975 during the Apollo-Soyuz Test Project, which were performed by using pointed grazing-incidence optics and a channel-electron multiplier as a photon detector. An EUV flux in the range from 55 to 150 A was detected from SS Cyg during an optical outburst at an intensity level considerably below that of Rappaport et al. (1974). Upper limits are placed on the EUV fluxes from Z Cha, VW Hyi, and AE Aqr. Multicolor optical photometry of SS Cyg and AE Aqr is also examined which was obtained simultaneously with the EUV observations. It is concluded that intrinsic EUV flux variability is probably a characteristic of SS Cyg and that the same system exhibits an extremely large range of soft X-ray luminosities while remaining at about the same visible light level. Several models for the SS Cyg system are compared with the EUV data.

Margon, B.↗

Study of X-ray optics

The testing is reported of a polished Kanigen coated beryllium mirror in a soft X-ray telescope to be flown on a Skylark sounding rocket. This test involved inserting the telescope in a 220 foot long vacuum line and taking photographs of an X-ray resolution source. These photographs were then used to evaluate the performance of the telescope mirror as a function of distance from the focal plane and the angular distance off the telescope axis. A second test was made in which a point source was used to study the imaging characteristics by means of a pinhole and proportional counter placed in the telescope focal plane. A third test was conducted using a position sensitive detector. The efficiency and resolution was increased by polishing.

Froechtenigt, J. F.↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Optimizing microfluidic flow cell geometry for in situ resonant soft X-ray characterization of molecular nanostructures

Liquid-phase resonant soft X-ray scattering (LP-RSoXS) is an emerging label-free technique to probe chemically resolved nanostructures of molecular or hybrid materials in liquid environments. Still, quantitative analysis is hindered by the pressure-induced deformation of thin silicon nitride (SiN) membranes used as windows in microfluidic flow cells, which attenuates the signal in nonlinear ways, making experimental optimization difficult. Here, in this work, we directly characterize this deformation under experimental conditions for a variety of cell configurations. We use this to develop a predictive model that combines transmission effects of SiN bowing, incident X-ray beam profiles, and material-dependent resonant scattering cross sections to simulate the effective scattering intensity at the detector across the carbon K-edge. Maps of the total signal across the flow cell window reveal that increasing the window width and polymer concentration shifts the anisotropic intensity distributions from the center toward the edges of the window. It was determined that an optimal SiN thickness of 50 nm, with a window aperture of 104 μm, maximizes the total signal for typical solute concentrations and energies across the carbon K-edge. Our results overturn the assumption that corner regions dominate the scattering signal, offering explicit design guidelines for maximizing LP-RSoXS signals and significantly advancing the quantitative application of this technique to the characterization of molecular and hybrid nanostructured materials in liquids.

Grabner, Devin [Washington State Univ., Pullman, W↗

Continuum radiated power density $(P^{\textrm{C}}_{\textrm{rad}})$ and effective charge $(Z_{\textrm{eff}})$ estimates from multi-energy photon-counting measurements

Multi-energy soft x-ray pinhole cameras have been designed, built, calibrated, and operated at Madison symmetric Torus, Alcator C-Mod, and more recently at Tokamak a configuration variable and Tungsten Environment in Steady-State Tokamak (WEST), to measure plasma emission across multiple energy ranges. Here we describe a new methodology to estimate the local continuum radiated power density and the plasma effective charge (Z eff ) directly from photon-counting measurements of the line-free continuum emission (Bremsstrahlung and Radiative Recombination) in several energy bands between 11 and 18 keV. This capability is particularly valuable for confinement systems using metal plasma-facing components, where x-ray losses from interactions with the sputtered wall can represent a significant fraction of the total radiated power (P rad ). The approach leverages a well-characterized detector responsivity, modeled by a complementary error function, and interprets the differential multi-energy measurements between adjacent energy levels through the probability density function of a Gaussian distribution. The implementation of this diagnostic technique is currently under development on the WEST tokamak, aiming at the goal of providing real-time P rad and Z eff measurements during long-pulse operation (up to 1000 s) in the 2026 campaign.

WEST↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

Variable X-ray sources.

The behavior of the quasi-periodic rapid variable Cyg X-1, the periodic variable Cen X-3, and the aperiodic variable Sco X-1 is described. Observations of Cyg X-1 were made by pointing the Uhuru satellite to a position where the object was in the band visible to the X-ray detectors; observations were also obtained by other methods. It appears that the X-ray emitting region is a few light sec in size, and some of the fast variations originate in a region as small as several earth radii in size. It is believed at present that a pulsating white dwarf could explain the X-ray behavior of Cen X-3. X-ray data from Sco X-1 reveal that it behaves in soft X rays much as it is well known to do in visible light.

Kellogg, E. M.↗

Soft X-ray detection with the Fairchild 100 by 100 CCD

The soft X-ray sensitivity of the Fairchild 100 x 100 element CCD is studied for possible use as a detector in plasma physics research. The experimental setup and laboratory results are reported including data on slow scan operation of the CCD and performance when cooled. Results from digital computer processing of the data to correct for element-to-element nonuniformities are also discussed.

Renda, G.↗

Absorption of CO2-laser radiation in a hypocycloidal-pinch plasma

Absorption of a 50-J pulsed CO2 laser beam in the plasma produced in a hypocycloidal-pinch apparatus was studied. The apparatus consists of three disk electrodes with a 5-cm hole on the axis. The current sheets are snow-plowed toward the center of the hole to produce a plasma with a density greater than 10 to the 18th/cu cm and a temperature near 1 keV which emits soft X rays for 5 microsec. IR detectors measured the laser radiation incident onto, transmitted through, and scattered from the plasma as functions of time. For a period up to 70 microsec from the onset of X-ray emission, neither transmitted nor scattered laser radiation was observed above the detector threshold of 0.3% of the incident flux. This indicates effective absorption of the laser beam (greater than 99%) and that the particle confinement time extends far beyond the energy confinement time of 5 microsec. Thus, the plasma in this apparatus appears much more amenable to laser heating than that in a theta pinch.

Lee, J. H.↗