Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “smoothness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Geographic smoothing of solar photovoltaic electric power production in the Western USA

We examined the geographic smoothing of solar photovoltaic generation from 15 utility-scale plants in California, Nevada, and Arizona and from 19 commercial building installations in California. This is the first comparison of geographic smoothing from utility-scale and building-mounted PV and the first examination of solar PV smoothing in this region. Our research questions were (1) how does geographic smoothing of commercial building rooftop PV compare to that of utility scale PV?, (2) is the geographic smoothing found for utility-scale plants the same for the western US as in India?, and (3) how does the geographic smoothing for PV compare to that of wind? By examining the power output of these generators in the frequency domain, we quantified the smoothing obtained by combining the output of geographically separated plants. We found that utility-scale and commercial rooftop plants exhibited similar geographic smoothing, with 10 combined plants reducing the amplitude of fluctuations at 1 h to 18%–28% of those seen for a single plant. We find that combining a few PV sites together reduces fluctuations, but that the point of quickly diminishing returns is reached after ∼5 sites, and that for all the locations and plant sizes considered, PV does not exhibit as much geographic smoothing as is seen for combining wind plants. We present preliminary theoretical arguments for why geographic smoothing of PV plants is less effective than that for wind plants. The slope of the high-frequency part of the PV power spectrum can at best be geographically smoothed (steepen) to an asymptotic spectrum of [Formula: see text]. This limit for PV has considerably less smoothing than that for wind's geographic smoothing, shown theoretically and from observed data to be [Formula: see text].

Klima, Kelly↗

Spline-Based Smoothing of Airfoil Curvatures

Constrained fitting for airfoil curvature smoothing (CFACS) is a splinebased method of interpolating airfoil surface coordinates (and, concomitantly, airfoil thicknesses) between specified discrete design points so as to obtain smoothing of surface-curvature profiles in addition to basic smoothing of surfaces. CFACS was developed in recognition of the fact that the performance of a transonic airfoil is directly related to both the curvature profile and the smoothness of the airfoil surface. Older methods of interpolation of airfoil surfaces involve various compromises between smoothing of surfaces and exact fitting of surfaces to specified discrete design points. While some of the older methods take curvature profiles into account, they nevertheless sometimes yield unfavorable results, including curvature oscillations near end points and substantial deviations from desired leading-edge shapes. In CFACS as in most of the older methods, one seeks a compromise between smoothing and exact fitting. Unlike in the older methods, the airfoil surface is modified as little as possible from its original specified form and, instead, is smoothed in such a way that the curvature profile becomes a smooth fit of the curvature profile of the original airfoil specification. CFACS involves a combination of rigorous mathematical modeling and knowledge-based heuristics. Rigorous mathematical formulation provides assurance of removal of undesirable curvature oscillations with minimum modification of the airfoil geometry. Knowledge-based heuristics bridge the gap between theory and designers best practices. In CFACS, one of the measures of the deviation of an airfoil surface from smoothness is the sum of squares of the jumps in the third derivatives of a cubicspline interpolation of the airfoil data. This measure is incorporated into a formulation for minimizing an overall deviation- from-smoothness measure of the airfoil data within a specified fitting error tolerance. CFACS has been extensively tested on a number of supercritical airfoil data sets generated by inverse design and optimization computer programs. All of the smoothing results show that CFACS is able to generate unbiased smooth fits of curvature profiles, trading small modifications of geometry for increasing curvature smoothness by eliminating curvature oscillations and bumps (see figure).

Li, W.↗

Diamond Smoothing Tools

Diamond smoothing tools have been proposed for use in conjunction with diamond cutting tools that are used in many finish-machining operations. Diamond machining (including finishing) is often used, for example, in fabrication of precise metal mirrors. A diamond smoothing tool according to the proposal would have a smooth spherical surface. For a given finish machining operation, the smoothing tool would be mounted next to the cutting tool. The smoothing tool would slide on the machined surface left behind by the cutting tool, plastically deforming the surface material and thereby reducing the roughness of the surface, closing microcracks and otherwise generally reducing or eliminating microscopic surface and subsurface defects, and increasing the microhardness of the surface layer. It has been estimated that if smoothing tools of this type were used in conjunction with cutting tools on sufficiently precise lathes, it would be possible to reduce the roughness of machined surfaces to as little as 3 nm. A tool according to the proposal would consist of a smoothing insert in a metal holder. The smoothing insert would be made from a diamond/metal functionally graded composite rod preform, which, in turn, would be made by sintering together a bulk single-crystal or polycrystalline diamond, a diamond powder, and a metallic alloy at high pressure. To form the spherical smoothing tip, the diamond end of the preform would be subjected to flat grinding, conical grinding, spherical grinding using diamond wheels, and finally spherical polishing and/or buffing using diamond powders. If the diamond were a single crystal, then it would be crystallographically oriented, relative to the machining motion, to minimize its wear and maximize its hardness. Spherically polished diamonds could also be useful for purposes other than smoothing in finish machining: They would likely also be suitable for use as heat-resistant, wear-resistant, unlubricated sliding-fit bearing inserts.

Voronov, Oleg↗

Estimation of Smoothing Error in SBUV Profile and Total Ozone Retrieval

Data from the Nimbus-4, Nimbus-7 Solar Backscatter Ultra Violet (SBUV) and seven of the NOAA series of SBUV/2 instruments spanning 41 years are being reprocessed using V8.6 algorithm. The data are scheduled to be released by the end of August 2011. An important focus of the new algorithm is to estimate various sources of errors in the SBUV profiles and total ozone retrievals. We discuss here the smoothing errors that describe the components of the profile variability that the SBUV observing system can not measure. The SBUV(/2) instruments have a vertical resolution of 5 km in the middle stratosphere, decreasing to 8 to 10 km below the ozone peak and above 0.5 hPa. To estimate the smoothing effect of the SBUV algorithm, the actual statistics of the fine vertical structure of ozone profiles must be known. The covariance matrix of the ensemble of measured ozone profiles with the high vertical resolution would be a formal representation of the actual ozone variability. We merged the MLS (version 3) and sonde ozone profiles to calculate the covariance matrix, which in general case, for single profile retrieval, might be a function of the latitude and month. Using the averaging kernels of the SBUV(/2) measurements and calculated total covariance matrix one can estimate the smoothing errors for the SBUV ozone profiles. A method to estimate the smoothing effect of the SBUV algorithm is described and the covariance matrixes and averaging kernels are provided along with the SBUV(/2) ozone profiles. The magnitude of the smoothing error varies with altitude, latitude, season and solar zenith angle. The analysis of the smoothing errors, based on the SBUV(/2) monthly zonal mean time series, shows that the largest smoothing errors were detected in the troposphere and might be as large as 15-20% and rapidly decrease with the altitude. In the stratosphere above 40 hPa the smoothing errors are less than 5% and between 10 and 1 hPa the smoothing errors are on the order of 1%. We validate our estimated smoothing errors by comparing the SBUV ozone profiles with other ozone profiling sensors.

Kramarova, N. A.↗

Employing Relaxed Smoothness Constraints on Imaginary Part of Refractive Index in AERONET Aerosol Retrieval Algorithm

In the Aerosol Robotic Network (AERONET) retrieval algorithm, smoothness constraints on the imaginary part of the refractive index provide control of retrieved spectral dependence of aerosol absorption by preventing the inversion code from fitting the noise in optical measurements and thus avoiding unrealistic oscillations of retrievals with wavelength. The history of implementation of the smoothness constraints in the AERONET retrieval algorithm is discussed. It is shown that the latest version of the smoothness constraints on the imaginary part of refractive index, termed standard and employed by Version 3 of the retrieval algorithm, should be modified to account for strong variability of light absorption by brown-carbon-containing aerosols in UV through mid-visible parts of the solar spectrum. In Version 3 strong spectral constraints were imposed at high values of the Ångström exponent (440–870 nm) since black carbon was assumed to be the primary absorber, while the constraints became increasingly relaxed as aerosol exponent deceased to allow for wavelength dependence of absorption for dust aerosols. The new version of the smoothness constraints on the imaginary part of the refractive index assigns different weights to different pairs of wavelengths, which are the same for all values of the Ångström exponent. For example, in the case of four-wavelength input, the weights assigned to short-wavelength pairs (440–675, 675–870 nm) are small so that smoothness constraints do not suppress natural spectral variability of the imaginary part of the refractive index. At longer wavelengths (870–1020 nm), however, the weight is 10 times higher to provide additional constraints on the imaginary part of refractive index retrievals of aerosols with a high Ångström exponent due to low sensitivity to aerosol absorption for longer channels at relatively low aerosol optical depths. The effect of applying the new version of smoothness constraints, termed relaxed, on retrievals of single-scattering albedo is analyzed for case studies of different aerosol types: black- and brown-carbon-containing fine mode aerosols, mineral dust coarse mode aerosols, and urban industrial fine mode aerosol. It is shown that for brown-carbon-containing aerosols employing the relaxed smoothness constraints resulted in significant reduction in retrieved single-scattering albedo and spectral residual errors (compared to standard) at the short wavelengths. For example, biomass burning smoke cases showed a reduction in single-scattering albedo and spectral residual error at 380 nm of ∼ 0.033 and ∼ 17 %, respectively, for the Rexburg site and ∼ 0.04 and ∼ 12.7 % for the Rimrock site, both AERONET sites in Idaho, USA. For a site with very high levels of black-carbon-containing aerosols (Mongu, Zambia), the effect of modification in the smoothness constraints was minor. For mineral dust aerosols at small Ångström exponent values (Mezaira site, UAE), the spectral constraint on the imaginary part of the refractive index was already relaxed in Version 3; therefore the new relaxed constraint results in minimal change. In the case of weakly absorbing urban industrial aerosols at the GSFC site, there are significant changes in retrieved single-scattering albedo using relaxed assumption, especially reductions at longer wavelengths: ∼ 0.016 and ∼ 0.02 at 875 and 1020 nm, respectively, for 440 nm aerosol optical depth (AOD) ∼ 0.3. The modification of smoothness constraints on the imaginary part of the refractive index has a minor effect on retrievals of other aerosol parameters such as the real part of the refractive index and parameters of the aerosol size distribution. The implementation of the relaxed smoothness constraints on the imaginary part of the refractive index in the next version of the AERONET inversion algorithm will produce significant impacts at some sites in short wavelength channels (380 and 440 nm) for some biomass burning smoke cases with significant brown carbon content and possibly in mid-visible channels (500 and 675 nm) to near-infrared channels (870 to 1020 nm) for some urban industrial aerosol types. However, most differences in single-scattering albedo retrievals between those applying the new relaxed constraint and the standard constraint will be within the uncertainty of the single-scattering albedo retrievals, depending on the level of aerosol optical depth, Ångström exponent, brown carbon content and wavelength.

Aliaksandr Siniuk↗

Comparing smoothing techniques for extracting MOSFET threshold voltage

Measurement noise acts as a barrier to the accurate calculation of threshold voltage by derivative-based extraction methods. We examined several smoothing techniques and their effects on measurement noise in threshold voltage extracted by the linear extrapolation method and the g m /I d method. We applied these techniques on a set of SiC power MOSFET devices before and after they had undergone accelerated thermal testing. The smoothing methods examined are least-squares polynomial fitting, low-pass filtering using Butterworth and Chebyshev fillers, and differential smoothing. These methods are compared by their shift in threshold voltage compared to unsmoothed data and their standard deviation among the measurements of each device. All methods performed poorly at smoothing when extracting via the g m /I d due to the large amounts of high-magnitude subthreshold noise, mostly tending to extract threshold voltages far below the expected value. Differential smoothing provided results closest to the expected value with an absolute shift of 1.2 V on average. The smoothing methods performed better with the LE method. On a failed device, all smoothing methods except polynomial smoothing preserved the large threshold voltage anomaly for four out of five measurements. These results show that choice of smoothing method, if used must be evaluated based on the device and extraction method.

42 ENGINEERING↗

Is there a clinical benefit with a smooth compensator design compared with a plunged compensator design for passive scattered protons?

In proton therapy, passive scattered proton plans use compensators to conform the dose to the distal surface of the planning volume. These devices are custom made from acrylic or wax for each treatment field using either a plunge-drilled or smooth-milled compensator design. The purpose of this study was to investigate if there is a clinical benefit of generating passive scattered proton radiation treatment plans with the smooth compensator design. We generated 4 plans with different techniques using the smooth compensators. We chose 5 sites and 5 patients for each site for the range of dosimetric effects to show adequate sample. The plans were compared and evaluated using multicriteria (MCA) plan quality metrics for plan assessment and comparison using the Quality Reports [EMR] technology by Canis Lupus LLC. The average absolute difference for dosimetric metrics from the plunged-depth plan ranged from −4.7 to +3.0 and the average absolute performance results ranged from −6.6% to +3%. The manually edited smooth compensator plan yielded the best dosimetric metric, +3.0, and performance, + 3.0% compared to the plunged-depth plan. It was also superior to the other smooth compensator plans. Our results indicate that there are multiple approaches to achieve plans with smooth compensators similar to the plunged-depth plans. The smooth compensators with manual compensator edits yielded equal or better target coverage and normal tissue (NT) doses compared with the other smooth compensator techniques. Further studies are under investigation to evaluate the robustness of the smooth compensator design.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-343: Dosimetric Investigation for Fluence Smoothing On VMAT Plans in Monaco for Head - Neck Cancers

Purpose: The study investigates the effect of fluence smoothing parameter on VMAT plans for ten head-neck cancer patients using Monaco5.00.04. Methods: VMAT plans were created using Monaco5.00.04 planning system for 10 head-neck patients. Four plans were generated for each patient using available smoothing parameters i.e. high, medium, low and off. The number of monitor units required to deliver 1 cGy was defined as a modulation degree; and was taken as a measure of plan complexity. Routinely used plan quality parameters Conformity index (CI) and Homogeneity index (HI) were used in the study. As a protocol our center, practices “medium” smoothing for clinical implementation. Plans with medium smoothing were opted as reference plans due to the clinical acceptance and dosimetric verifications made on these plans. Plans were generated by varying the smoothing parameter and re-optimization was done. The PTV was evaluated for D98%, D95%, D50%, D1% and prescription isodose volume (PIV). For critical organs; spine and parotids the parameters recorded were D1cc and Dmean respectively. Results: The cohort had the median prescription as 6000 cGy in the range of 6600 cGy - 4500 cGy. The modulation degree was observed to increase up to 6% from reference to the most complex plan. High smoothing had about 11% increase in segments which marginally (0.5 to 1%) increased the homogeneity index while conformity index remains constant. For spine the maximum D1cc was observed in medium smoothing as 4639.8 cGy, this plan was clinically accepted and dosimetrically verified. Similarly for parotids, the Dmean was 2011.9 cGy and 1817.05 cGy. Conclusion: The sensitivity of plan quality in terms of smoothing options (high, medium, low and off) available in Monaco 5.00.04 was resulted in minimal difference in terms of target coverage, conformity index and homogeneity index. Similarly changing smoothing did not result in any enhanced advantage in sparing of critical organs.

60 APPLIED LIFE SCIENCES↗

A Meshfree Cell-based Smoothed Point Interpolation Method for Solid Mechanics Problems

In the framework of a weakened weak (W{sup 2}) formulation using a generalized gradient smoothing operation, this paper introduces a novel meshfree cell-based smoothed point interpolation method (CS-PIM) for solid mechanics problems. The W{sup 2} formulation seeks solutions from a normed G space which includes both continuous and discontinuous functions and allows the use of much more types of methods to create shape functions for numerical methods. When PIM shape functions are used, the functions constructed are in general not continuous over the entire problem domain and hence are not compatible. Such an interpolation is not in a traditional H{sup 1} space, but in a G{sup 1} space. By introducing the generalized gradient smoothing operation properly, the requirement on function is now further weakened upon the already weakened requirement for functions in a H{sup 1} space and G{sup 1} space can be viewed as a space of functions with weakened weak (W{sup 2}) requirement on continuity. The cell-based smoothed point interpolation method (CS-PIM) is formulated based on the W{sup 2} formulation, in which displacement field is approximated using the PIM shape functions, which possess the Kronecker delta property facilitating the enforcement of essential boundary conditions [3]. The gradient (strain) field is constructed by the generalized gradient smoothing operation within the cell-based smoothing domains, which are exactly the triangular background cells. A W{sup 2} formulation of generalized smoothed Galerkin (GS-Galerkin) weak form is used to derive the discretized system equations. It was found that the CS-PIM possesses the following attractive properties: (1) It is very easy to implement and works well with the simplest linear triangular mesh without introducing additional degrees of freedom; (2) it is at least linearly conforming; (3) this method is temporally stable and works well for dynamic analysis; (4) it possesses a close-to-exact stiffness, which is much softer than the overly-stiff FEM model and much stiffer than the overly-soft node-based smoothed point interpolation method (NS-PIM); (5) the results of the present method are of better accuracy and higher convergence rate than the linear FEM model using the same set of triangular meshes.

97 MATHEMATICS AND COMPUTING↗

On finite-dimensional smoothed-particle Hamiltonian reductions of the Vlasov equation

The inclusion of spatial smoothing in finite-dimensional particle-based Hamiltonian reductions of the Vlasov equation and related models is considered. Here, this work investigates the underlying Hamiltonian structure of such smoothed particle-based methods for Hamiltonian systems and the small-scale regularization such methods implicitly make in approximating the continuum theory. In the context of the Vlasov–Poisson equation and other mean-field Lie–Poisson systems, of which Vlasov–Poisson is a special case, smoothing amounts to a convolutive regularization of the Hamiltonian. This regularization may be interpreted as a change of the inner product structure used to identify the dual space in the Lie–Poisson Hamiltonian formulation. In particular, the shape function used for spatial smoothing may be identified as the kernel function of a reproducing kernel Hilbert space whose inner product is used to define the Lie–Poisson Hamiltonian structure. It is likewise possible to introduce smoothing in the Vlasov–Maxwell system, but in this case the Poisson bracket must be modified rather than the Hamiltonian. The smoothing applied to the Vlasov–Maxwell system is incorporated by inserting smoothing in the map from canonical to kinematic coordinates. In the filtered system, the Lorentz force law and the current, the two terms coupling the Vlasov equation with Maxwell’s equations, are spatially smoothed.

Hamiltonian mechanics↗

Adaptive diffusion smoothing: A diffusion-based method to reduce IMRT field complexity

Inverse-planned intensity modulated radiation therapy (IMRT) is often able to achieve complex treatment planning goals that are unattainable with forward three-dimensional (3D) conformal planning. However, the common use of IMRT has introduced several new challenges. The potentially high degree of modulation in IMRT beams risks the loss of some advantages of 3D planning, such as excellent target coverage and high delivery efficiency. Previous attempts to reduce beam complexity by smoothing often result in plan degradation because the smoothing algorithm cannot distinguish between areas of desirable and undesirable modulation. The purpose of this work is to introduce and evaluate adaptive diffusion smoothing (ADS), a novel procedure designed to preferentially reduce IMRT beam complexity. In this method, a discrete diffusion equation is used to smooth IMRT beams using diffusion coefficients, automatically defined for each beamlet, that dictate the degree of smoothing allowed for each beamlet. This yields a method that can distinguish between areas of desirable and undesirable modulation. The ADS method has been incorporated into our optimization system as a weighted cost function penalty, with two diffusion coefficient definitions designed to promote: (1) uniform smoothing everywhere or (2) smoothing based on cost function gradients with respect to the plan beamlet intensities. The ADS method (with both coefficient types) has been tested in a phantom and in two clinical examples (prostate and head/neck). Both types of diffusion coefficients produce plans with reduced modulation and minimal dosimetric impact, but the cost function gradient-based coefficients show more potential for reducing beam modulation without affecting dosimetric plan quality. In summary, adaptive diffusion smoothing is a promising tool for ensuring that only the necessary amount of beam modulation is used, promoting more efficient and accurate IMRT planning, QA, and delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-314: Dosimetric Effect of Smooth Drilling On Proton Compensators in Prostate Patients

Purpose: To evaluate the dosimetric effect of smooth drilling of proton compensators in proton prostate plans when compared to typical plunge drilling settings. Methods: Twelve prostate patients were planned in Eclipse treatment planning system using three different drill settings Smooth, Plunge drill A, and Plunge drill B. The differences between A and B were: spacing X[cm]: 0.4(A), 0.1(B), spacing Y[cm]: 0.35(A), 0.1(B), row offset [cm]: 0.2(A), 0(B). Planning parameters were kept consistent between the different plans, which utilized two opposed lateral beams arrangement. Mean differences absolute dosimetry in OAR constraints are presented. Results: The smooth drilled compensator based plans yielded equivalent target coverage to the plans generated with drill settings A and B. Overall, the smooth compensators reduced dose to the majority of organs at risk compared to settings A and B. Constraints were reduced for the following OAR: Rectal V75 by 2.12 and 2.48%, V70 by 2.45 and 2.91%, V65 by 2.85 and 3.37%, V50 by 2.3 and 5.1%, Bladder V65 by 4.49 and 3.67%, Penial Bulb mean by 3.7 and 4.2Gy, and the maximum plan dose 5.3 and 7.4Gy for option A vs smooth and option B vs smooth respectively. The femoral head constraint (V50<5%) was met by all plans, but it was not consistently lower for the smooth drilling plan. Conclusion: Smooth drilled compensators provide equivalent target coverage and overall slightly cooler plans to the majority of organs at risk; it also minimizes the potential dosimetric impacts caused by patient positioning uncertainty.

60 APPLIED LIFE SCIENCES↗

Leiomodin and tropomodulin in smooth muscle

Evidence is accumulating to suggest that actin filament remodeling is critical for smooth muscle contraction, which implicates actin filament ends as important sites for regulation of contraction. Tropomodulin (Tmod) and smooth muscle leiomodin (SM-Lmod) have been found in many tissues containing smooth muscle by protein immunoblot and immunofluorescence microscopy. Both proteins cofractionate with tropomyosin in the Triton-insoluble cytoskeleton of rabbit stomach smooth muscle and are solubilized by high salt. SM-Lmod binds muscle tropomyosin, a biochemical activity characteristic of Tmod proteins. SM-Lmod staining is present along the length of actin filaments in rat intestinal smooth muscle, while Tmod stains in a punctate pattern distinct from that of actin filaments or the dense body marker alpha-actinin. After smooth muscle is hypercontracted by treatment with 10 mM Ca(2+), both SM-Lmod and Tmod are found near alpha-actinin at the periphery of actin-rich contraction bands. These data suggest that SM-Lmod is a novel component of the smooth muscle actin cytoskeleton and, furthermore, that the pointed ends of actin filaments in smooth muscle may be capped by Tmod in localized clusters.

Carrier Proteins/analysis/genetics/metabolism↗

Thermal oscillation smoothing of DT solid layers for HAPL and NIF scale targets

Deuterium-Tritium (D-T) solid fuel layers must meet stringent roughness specifications for both the ICF and IFE laser fusion programs and native beta-layering alone is unable to provide sufficient solid layer smoothing to meet these specifications at 18.3 K or below. Consequently, several supplemental smoothing options have been proposed to resolve this issue, including a technique called 'Thermal Breathing'. This technique consists of oscillating the temperature of the solid D-T layer about its equilibration temperature for a period of one to several hours. Recently, thermal oscillations have been used to successfully smooth rough solid D{sub 2} in spherical targets. In order to study this particular smoothing technique, we examined the effects of thermal oscillations on equilibrated D-T solid layers, using both ICF and IFE scale layering cells and layer thicknesses. The D-T solid layers that were Subjected to thermal breathing in these studies were equilibrated at temperatures ranging from 16.0 K to 19.25 K, followed by 1.5 to 2 hours of temperature oscillations. During the HAPL scale experiments the amplitude and period of the oscillations were both varied to examine parametric effects of these variables on final layer roughness. In both sets of experiments, once the oscillations completed we allowed the layers to 'relax' at their initial equilibration temperature for another 1 to 2 hours, to observe any 'rebounding' or re-roughening that might occur. The rCF scale experiments were performed using a 2 mm beryllium torus, for which the layer was free from optical distortions that were observed in our IFE scale cell (a 4 mm dia. sapphire sphere-cylinder). Our results showed a temperature dependent smoothing effect ofthe DT solid layer ranging from 20% to 35% over the temperature range of 17.3 K to 19.0 K for the rCF-scale, 2-mm celL The final RMS roughness for layers grown in this 2-mm Be torus was on average less than 1 /lm for modes 7 and above. Results for the rFE scale cell showed a temperature dependent smoothing effect that varied from 5% to more than 30% over a 16.0 K to 18.3 K temperature span, and which resulted in an average overall RMS roughness of3.8 /lm at 17.3 K and 3.2 /lm at 18.3 K. We discuss the configuration ofboth of these DT layering cells, the equilibration and oscillation parameters were used, and results that show thermal oscillations can make significant contributions to the smoothing of normally equilibrated beta-layered surfaces, as well as potentially reducing the time required to produce smooth solid DT surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Smooth halos in the cosmic web

Dark matter halos can be defined as smooth distributions of dark matter placed in a non-smooth cosmic web structure. This definition of halos demands a precise definition of smoothness and a characterization of the manner in which the transition from smooth halos to the cosmic web takes place. We introduce entropic measures of smoothness, related to measures of inequality previously used in economy and with the advantage of being connected with standard methods of multifractal analysis already used for characterizing the cosmic web structure in cold dark matter N-body simulations. These entropic measures provide us with a quantitative description of the transition from the small scales portrayed as a distribution of halos to the larger scales portrayed as a cosmic web and, therefore, allow us to assign definite sizes to halos. However, these ''smoothness sizes'' have no direct relation to the virial radii. Finally, we discuss the influence of N-body discreteness parameters on smoothness.

79 ASTRONOMY AND ASTROPHYSICS↗

Differential gene expression profiling of human adipose stem cells differentiating into smooth muscle-like cells by TGFβ1/BMP4

Regenerative repair of the vascular system is challenging from the perspectives of translational medicine and tissue engineering. There are fundamental hurdles in front of creating bioartificial arteries, which involve recaputilation of the three-layered structure under laboratory settings. Obtaining and maintaining smooth muscle characteristics is an important limitation, as the transdifferentiated cells fail to display mature phenotype. This study aims to shed light on the smooth muscle differentiation of human adipose stem cells (hASCs). To this end, we first acquired hASCs from lipoaspirate samples. Upon characterization, the cells were induced to differentiate into smooth muscle (SM)-like cells using a variety of inducer combinations. Among all, TGFβ1/BMP4 combination had the highest differentiation efficiency, based on immunohistochemical analyses. hSM-like cell samples were compared to hASCs and to the positive control, human coronary artery-smooth muscle cells (hCA-SMCs) through gene transcription profiling. Microarray findings revealed the activation of gene groups that function in smooth muscle differentiation, signaling pathways, extracellular modeling and cell proliferation. Our results underline the effectiveness of the growth factors and suggest some potential variables for detecting the SM-like cell characteristics. Evidence in transcriptome level was used to evaluate the TGFβ1/BMP4 combination as a previously unexplored effector for the smooth muscle differentiation of adipose stem cells. - Highlights: • Human adipose stem cells (hASCs) were isolated, characterized and cultured. • Growth factor combinations were evaluated for their effectiveness in differentiation using IHC. • hASCs were differentiated into smooth muscle (SM)-like cells using TGF-β1 and BMP4 combination. • Microarray analysis was performed for hASCs, SM-like cells and coronary artery-SMCs. • Microarray data was used to perform hierarchical clustering and interpretation of activated pathways.

60 APPLIED LIFE SCIENCES↗

NUMERICAL CONVERGENCE IN SMOOTHED PARTICLE HYDRODYNAMICS

We study the convergence properties of smoothed particle hydrodynamics (SPH) using numerical tests and simple analytic considerations. Our analysis shows that formal numerical convergence is possible in SPH only in the joint limit N → ∞, h → 0, and N{sub nb} → ∞, where N is the total number of particles, h is the smoothing length, and N{sub nb} is the number of neighbor particles within the smoothing volume used to compute smoothed estimates. Previous work has generally assumed that the conditions N → ∞ and h → 0 are sufficient to achieve convergence, while holding N{sub nb} fixed. We demonstrate that if N{sub nb} is held fixed as the resolution is increased, there will be a residual source of error that does not vanish as N → ∞ and h → 0. Formal numerical convergence in SPH is possible only if N{sub nb} is increased systematically as the resolution is improved. Using analytic arguments, we derive an optimal compromise scaling for N{sub nb} by requiring that this source of error balance that present in the smoothing procedure. For typical choices of the smoothing kernel, we find N{sub nb} ∝N {sup 0.5}. This means that if SPH is to be used as a numerically convergent method, the required computational cost does not scale with particle number as O(N), but rather as O(N {sup 1} {sup +} {sup δ}), where δ ≈ 0.5, with a weak dependence on the form of the smoothing kernel.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing the pressure smoothing scale of the intergalactic medium

The thermal state of the intergalactic medium (IGM) at z < 6 constrains the nature and timing of cosmic reionization events, but its inference from the Lyα forest is degenerate with the 3D structure of the IGM on ∼100 kpc scales, where, analogous to the classical Jeans argument, the pressure of the T ≃ 10{sup 4} K gas supports it against gravity. We simulate the IGM using smoothed particle hydrodynamics, and find that, at z < 6, the gas density power spectrum does not exhibit the expected filtering scale cutoff, because dense gas in collapsed halos dominates the small-scale power masking pressure smoothing effects. We introduce a new statistic, the real-space Lyα flux, F{sub real}, which naturally suppresses dense gas, and is thus robust against the poorly understood physics of galaxy formation, revealing pressure smoothing in the diffuse IGM. The F{sub real} power spectrum is accurately described by a simple fitting function with cutoff at λ{sub F}, allowing us to rigorously quantify the pressure smoothing scale for the first time: we find λ{sub F} = 79 kpc (comoving) at z = 3 for our fiducial thermal model. This statistic has the added advantage that it directly relates to observations of correlated Lyα forest absorption in close quasar pairs, recently proposed as a method to measure the pressure smoothing scale. Our results enable one to quantify the pressure smoothing scale in simulations, and ask meaningful questions about its dependence on reionization and thermal history. Accordingly, the standard description of the IGM in terms of the amplitude T{sub 0} and slope γ of the temperature–density relation T=T{sub 0}(ρ/ ρ-bar ){sup γ−1} should be augmented with a third pressure smoothing scale parameter λ{sub F}.

79 ASTRONOMY AND ASTROPHYSICS↗