Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “small-signal stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Application of small-signal modeling and measurement techniques to the stability analysis of an integrated switching-mode power system

Small-signal modeling techniques are used in a system stability analysis of a breadboard version of a complete functional electrical power system. The system consists of a regulated switching dc-to-dc converter, a solar-cell-array simulator, a solar-array EMI filter, battery chargers and linear shunt regulators. Loss mechanisms in the converter power stage, including switching-time effects in the semiconductor elements, are incorporated into the modeling procedure to provide an accurate representation of the system without requiring frequency-domain measurements to determine the damping factor. The small-signal system model is validated by the use of special measurement techniques which are adapted to the poor signal-to-noise ratio encountered in switching-mode systems. The complete electrical power system with the solar-array EMI filter is shown to be stable over the intended range of operation.

Wong, R. C.↗

Seamless Transition of Critical Infrastructures using Droop Controlled Grid-forming Inverters

Seamless recovery of power to critical infrastructures, after grid failure, is a crucial need arising in scenarios that are increasingly becoming more frequent. Here, this article proposes a seamless transition strategy using a single and unified mode-dependent droop controlled grid-forming inverters. The control strategy achieves the following objectives: 1) regulates the output active and reactive power by the droop-controlled inverters to a desired value while operating in on-grid mode; 2) seamless transition and recovery of power injections into the load after grid failure by inverters that operates in grid-forming mode all the time; 3) requires only a single bit of information on the grid/network status for the mode transition. A framework for assessing the stability of the system and to guide the choice of parameters for controllers is developed using control-oriented modeling. A controller hardware-in-the-loop-based real-time simulation study on a test system based on the realistic electrical network of a commercial-scale medical center is conducted for initial prototyping of the control strategy. A hardware experiment is conducted with two 3 - $\phi$, 480 -V, 125 -kVA grid-forming inverters, a 3 - $\phi$, 480 -V, 270 -kVA grid simulator, a physical grid switch, and a physical load bank. The experimental data establishes the effectiveness of the always grid-forming operation and control of inverters in meeting power delivery objectives when on-grid and off-grid under various kinds of loads and scenarios while minimizing transients during transitions. Furthermore, performance comparison with existing strategies showcases the advantage of the proposed strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diodes stabilize LED output

Small-signal diodes are placed in series with light-emitting diodes (LED's) to stabilize LED output against temperature fluctuations. Simple inexpensive method compensates for thermal fluctuations over a broad temperature range. Requiring few components, technique is particularly useful where circuit-board space is limited.

Deters, R. A.↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

damping controller↗

System Modeling and Robust Stability Region Analysis for Multi-inverters Based on VSG

As the number of inverter-interfaced distributed generators (IIDGs) increases, the decrease in the inertia of the microgrid affects the stability of microgrid voltage and current. The virtual synchronous generator (VSG) control method simulates the output characteristics of the synchronous machine to improve the inertia and damping of the microgrid. However, low-frequency oscillations can occur in systems with multi-VSGs connected in parallel, primarily when operating in island mode. Therefore, this article develops the small-signal state-space model for multi-inverters based on VSG and analyses the robust stability region (RSR) of the control parameters. Firstly, an extensible small-signal state-space model is established and simplified in the dq axis, which is a necessary preprocessing for the subsequent stability analysis. Secondly, the guardian map method based on bialternate product operation is constructed, and the RSR is established through translation mapping and rotation mapping. Therefore, the solution of RSR is transformed into the problem of identifying the Hurwitz matrix. Finally, the simulations and experiments verify that the calculated region can ensure stable operation during startup and meet the requirement to suppress low-frequency oscillations. In conclusion, the method of solving RSR proposed in this paper provides a basis for selecting controller parameters in practical engineering.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Linearized stability analysis and design of a flyback dc-dc boost regulator.

Analytic expressions for the small-signal power-stage describing functions of a switched dc-dc boost regulator are derived from an approximate continuous circuit model which is developed by a time-averaging technique. Closed-loop stability is attained through the design of frequency compensation of the loop gain. Open- and closed-loop regulator output impedances are derived from the linearized models for the given configuration. The analysis and design are compared with and confirmed by breadboard measurements.

Wester, G. W.↗

Fuzzy Current-Mode Control and Stability Analysis

In this paper a current-mode control (CMC) methodology is developed for a buck converter by using a fuzzy logic controller. Conventional CMC methodologies are based on lead-lag compensation with voltage and inductor current feedback. In this paper the converter lead-lag compensation will be substituted with a fuzzy controller. A small-signal model of the fuzzy controller will also be developed in order to examine the stability properties of this buck converter control system. The paper develops an analytical approach, introducing fuzzy control into the area of CMC.

Kopasakis, George↗

A Lyapunov-Based Generalized Dc-Side Controller Design for PV-Connected Systems

The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1k VA experimental setup that interfaces a PV module to the grid.

generalized PV controller↗

Investigations of stability and dynamic performances of switching regulators employing current-injected control

The stability and dynamic performances of a buck/boost regulator employing a current-injected control are examined. Small-signal models for the power state, the multi-loop error processor and the duty-cycle pulse-modulator are developed. The error-processor model which incorporates the current-injected loop, the dc loop and the compensation network permits evaluation of the effects of each individual control loop and their combined efforts toward shaping the performance characteristics of the closed-loop system. Comparisons are made between this modeling approach and earlier approaches. Some important yet subtle dissimilarities are discussed. This model predicts the constant-frequency 50 percent duty-cycle instability which is inherent to the current-injected control.

Lee, F. C.↗

On Stability of PQ-Controlled Grid-Following and Droop-Control Grid-Forming Inverters

In this paper, the nonlinearity impacts of PQ-control schemes and LCL filter parameter variations on the stability of grid-interactive inverters are studied under weak grid conditions. This work demonstrates that the control nonlinearity and parameter variations can cause unexpected instability at low power levels. This instability issue in the nominal operating range may occur under specific control parameters due to the shift of the low-frequency eigenvalues of PQ-controlled inverters. A full-order small-signal model for PQ-controlled inverters is applied to analyze this instability issue. Furthermore, the impacts of the droop coefficients on the stability of the droop-controlled grid-forming inverter are also investigated using the closed-loop inverter model. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator and a hardware setup of a microgrid fed by two 5 kVA 208V inverters.

Hossen, Tareq↗

Rotated-Droop Control for Enhanced Stability and Power Decoupling in Microgrids With Complex Line Impedances

Classical droop control in microgrids predominantly assumes inductive line impedance, which simplifies implementation but causes power coupling and steady-state errors in systems with resistive and inductive lines. This paper proposes a rotated-droop control strategy for grid-forming inverters that reformulates the power equations by incorporating the magnitude and angle of the line impedance within a rotated reference frame. This method enhances the decoupling of active and reactive power dynamics without increasing complexity or requiring communication links. A small-signal state-space model was created to capture the dynamic behavior of the system under varying impedance parameters, preserving the original droop gains by rotating the power control structure. This allows eigenvalue-based stability analysis and enhances damping and transient performance. Simulation and experimental results validated the improved power-sharing performance, faster response, and robustness of the proposed method under different impedance conditions. This approach maintains the decentralized structure of the conventional droop control while enabling greater adaptability and scalability, making it suitable for modern inverter-based microgrids with dynamic topologies.

Campo-Ossa, Daniel Dario [Univ. of Puerto Rico, Ag↗

Quantitative energy extraction measurements in a photoionization-stabilized self-sustained XeF laser

Detailed time-correlated gain, fluorescence, and laser energy measurements were used to obtain quantitative data on energy extraction efficiencies for a photoionization-stabilized self-sustained XeF laser. A current pulse of 25 ns full width at half-maximum produced an 80-cu-cm XeF plasma in NF3:Xe:He gas mixtures with a maximum output energy of 80 mJ. The results show that the maximum small-signal gain and the maximum specific output energy is proportional to the NF3 content of the gas mixture. This suggests that there is an optimum fractional utilization of the NF3 molecules in the discharge. Under high-gain conditions, 30-40% of the energy stored in XeF(asterisk) can be extracted in a gain-switched pulse. The output energy represents less than 1% of the input energy.

Lee, C. M.↗

A Lyapunov-Based Generalized Dc-Side Controller Design for PV-Connected Systems: Preprint

The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1-kVA experimental setup that interfaces a PV module to the grid.

dc-dc control↗

Stability analysis and compensation of a boost regulator with two-loop control

A useful stability measure has been demonstrated by Wester (1973) for switching regulators with a single feedback loop by applying the Nyquist criterion to the approximate loop gain determined by a time-averaging technique. This approach is extended and applied to the characterization, stability analysis, and compensation design of a switching regulator with two-loop control. The role and relative significance of each control loop is clarified on the basis of a description of circuit operation, and the major and minor loops are identified. In view of the inapplicability of linear feedback theory, describing functions of the feedback loops and power stage are derived, using small-signal analysis. Several phenomena revealed from an analysis of the major loop gain are discussed.

Wester, G. W.↗