Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “slow control system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Time scale analysis of a closed-loop discrete optimal control system

A two-time scale discrete control system is considered. The closed-loop optimal linear quadratic (LQ) regulator for the system requires the solution of a full-order algebraic matrix Riccati equation. Alternatively, the original system is decomposed into reduced-order slow and fast subsystems. The closed-loop optimal control of the subsystems requires the solution of two algebraic matrix Riccati equations of order lower than that required for the full-order system. A composite, closed-loop suboptimal control is created from the sum of the slow and fast feedback optimal controls. Numerical results obtained for an aircraft model show a very close agreement between the exact (optimal) solutions and computationally simpler composite (suboptimal) solutions. The main advantage of the method is the considerable reduction in the overall computational requirements for the closed-loop optimal control of digital flight systems.

Naidu, D. S.↗

Flight-Test Validation and Flying Qualities Evaluation of a Rotorcraft UAV Flight Control System

This paper presents a process of design and flight-test validation and flying qualities evaluation of a flight control system for a rotorcraft-based unmanned aerial vehicle (RUAV). The keystone of this process is an accurate flight-dynamic model of the aircraft, derived by using system identification modeling. The model captures the most relevant dynamic features of our unmanned rotorcraft, and explicitly accounts for the presence of a stabilizer bar. Using the identified model we were able to determine the performance margins of our original control system and identify limiting factors. The performance limitations were addressed and the attitude control system was 0ptimize.d for different three performance levels: slow, medium, fast. The optimized control laws will be implemented in our RUAV. We will first determine the validity of our control design approach by flight test validating our optimized controllers. Subsequently, we will fly a series of maneuvers with the three optimized controllers to determine the level of flying qualities that can be attained. The outcome enable us to draw important conclusions on the flying qualities requirements for small-scale RUAVs.

Mettler, Bernard↗

Linear regulator design for stochastic systems by a multiple time-scales method

This short paper develops a hierarchically structured, suboptimal controller for a linear stochastic system composed of fast and slow subsystems. It is proved that the controller is optimal in the limit as the separation of time scales of the subsystems becomes infinite. The methodology is illustrated by design of a controller to suppress the phugoid and short-period modes of the longitudinal dynamics of the F-8 aircraft.

Teneketzis, D.↗

Linear regulator design for stochastic systems by a multiple time scales method

This paper develops a hierarchically-structured, suboptimal controller for a linear stochastic system composed of fast and slow subsystems. It is proved that the controller is optimal in the limit as the separation of time scales of the subsystems becomes infinite. The methodology is illustrated by design of a controller to suppress the phugoid and short period modes of the longitudinal dynamics of the F-8 aircraft.

Teneketzis, D.↗

Directly Fused Porphyrin‐Tetracyanopentacenequinone Conjugates: Role of the Cross‐Conjugated, Powerful Electron Acceptor in Promoting Highly Efficient Charge Separation

Tetracyanopentacenequinone, a powerful electron acceptor, is fused directly to the porphyrin π-system to create a new class of donor-acceptor conjugates. Owing to the direct fusion and electron-deficient property of tetracyanopentacenequinone, strong intramolecular charge transfer both in the ground and excited states was witnessed. As a control, porphyrin fused with pentacenequinone was also investigated. Upon complete spectral and electrochemical characterization, the excited state properties were initially probed by time-dependent DFT studies, and the occurrence of electron transfer from different excited states was established. Free-energy calculations revealed higher exothermic electron transfer (>600 mV) than the control pentacenequinone-porphyrin systems. Pump-probe studies covering broad spatial and temporal regions revealed efficient excited state charge separation. This was unlike the control pentacenequinone-porphyrin system, where slow charge separation was witnessed only in the case of the zinc derivatives but not the free-base ones, followed by the populating of the triplet excited state. The lifetimes of the charge-separated states ranged between 30–500 ps depending on the solvent and metal ion in the porphyrin cavity. Nanosecond transient absorption studies established the charge recombination path to populate the triplet state of porphyrin or directly to the ground state as a function of solvent polarity and the nature of the conjugate. Furthermore, the significance of cross-conjugated tetracyanopentacenequinone fused directly to the porphyrin π system in promoting highly exothermic and efficient charge separation, irrespective of its cross conjugation, is borne out from this study.

Cross conjugation↗

Design of feedback control systems for unstable plants with saturating actuators

A new control design methodology is introduced for multi-input/multi-output systems with unstable open loop plants and saturating actuators. A control system is designed using well known linear control theory techniques and then a reference prefilter is introduced so that when the references are sufficiently small, the control system operates linearly as designated. For signals large enough to cause saturations, the control law is modified in such a way to ensure stability and to preserve, to the extent possible, the behavior of the linear control design. Key benefits of this methodology are: the modified feedback system never produces saturating control signals, integrators and/or slow dynamics in the compensator never windup, the directionaL properties of the controls are maintained, and the closed loop system has certain guaranteed stability properties. The advantages of the new design methodology are illustrated in the simulation of an approximation of the AFTI-16 (Advanced Fighter Technology Integration) aircraft multivariable longitudinal dynamics.

Kapasouris, Petros↗

A slow response temperature controller

The circuit diagram for a temperature controller for use with very fast-acting (low thermal mass) furnace systems is presented and its features described. The operation of the slow response temperature controller is discussed.

Mullins, O.↗

Machine Learning-Based Model Predictive Control of Two-Time-Scale Systems

In this study, we present a general form of nonlinear two-time-scale systems, where singular perturbation analysis is used to separate the dynamics of the slow and fast subsystems. Machine learning techniques are utilized to approximate the dynamics of both subsystems. Specifically, a recurrent neural network (RNN) and a feedforward neural network (FNN) are used to predict the slow and fast state vectors, respectively. Moreover, we investigate the generalization error bounds for these machine learning models approximating the dynamics of two-time-scale systems. Next, under the assumption that the fast states are asymptotically stable, our focus shifts toward designing a Lyapunov-based model predictive control (LMPC) scheme that exclusively employs the RNN to predict the dynamics of the slow states. Additionally, we derive sufficient conditions to guarantee the closed-loop stability of the system under the sample-and-hold implementation of the controller. A nonlinear chemical process example is used to demonstrate the theory. In particular, two RNN models are constructed: one to model the full two-time-scale system and the other to predict solely the slow state vector. Both models are integrated within the LMPC scheme, and we compare their closed-loop performance while assessing the computational time required to execute the LMPC optimization problem.

97 MATHEMATICS AND COMPUTING↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Monitoring and Assessment of Neuro-Adaptive Controllers for Aerospace Applications Using a Bayesian Approach

Modern exploration missions require modern control systems-control systems that can handle catastrophic changes in the system's behavior, compensate for slow deterioration in sustained operations, and support fast system ID. Adaptive controllers, based upon Neural Networks have these capabilities, but they can only be used safely if proper verification & validation (V&V) can be done. In this paper we present our V & V approach and simulation result within NASA's Intelligent Flight Control Systems (IFCS).

Gupta, Pramod↗

Automatic speed control of highway traffic

Vehicle control system monitors all vehicles in its range, and automatically slows down speeding vehicles by activating governor in vehicle. System determines only maximum speed; speeds below maximum are controlled by vehicle operator. Loss of transmitted signal or activation of emergency over-ride will open fuel line and return control to operator.

Klingman, E. E.↗

Altitude Wind Tunnel Investigation of the Performance of Compressor, Combustor, and Turbine Components of Prototype J47D (RX1-1) Turbojet Engine

As a portion of an over-all performance investigation of the prototype J47D (RX-1) turbojet engine, performance of the compressor, combustor, and turbine components has been determined in the Lewis altitude wind tunnel over a range of altitude from 5000 to 55,000 feet and at flight Mach numbers from 0.19 to 0.92. Investigations were conducted with the engine operating on an electronic control schedule and slow with a two-lever control system by which fuel flow and exhaust-nozzle area could be controlled separately. Two combustor configurations were investigated.

ENGINES, TURBO-JET↗

A Sweet H 2 S/H 2 O 2 Dual Release System and Specific Protein S-Persulfidation Mediated by Thioglucose/Glucose Oxidase

H 2 S and H 2 O 2 are two redox regulating molecules that play important roles in many physiological and pathological processes. While each of them has distinct biosynthetic pathways and signaling mechanisms, the crosstalk between these two species is also known to cause critical biological responses such as protein S-persulfidation. So far, many chemical tools for the studies of H 2 S and H 2 O 2 have been developed, such as the donors and sensors for H 2 S and H 2 O 2 . However, these tools are normally targeting single species (e.g. only H 2 S or only H 2 O 2 ). As such, the crosstalk and synergetic effects between H 2 S and H 2 O 2 can hardly been studied with those tools. Here, we report a unique H 2 S/H 2 O 2 dual donor system by employing 1-thio-ß-D-glucose and glucose oxidase (GOx) as the substrates. This enzymatic system can simultaneously produce H 2 S and H 2 O 2 in a slow and controllable fashion, without generating any bio-unfriendly byproducts. This system was demonstrated to cause efficient S-persulfidation on proteins. In addition, we expanded the system to thiolactose and thioglucose-disulfide, therefore, additional factors (ß-galactosidase and cellular reductants) could be introduced to further control the release of H 2 S/H 2 O 2 . This dual release system should be useful for future research on H 2 S and H 2 O 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control of large wind turbine generators connected to utility networks

This is an investigation of the control requirements for variable pitch wind turbine generators connected to electric power systems. The requirements include operation in very small as well as very large power systems. Control systems are developed for wind turbines with synchronous, induction, and doubly fed generators. Simulation results are presented. It is shown how wind turbines and power system controls can be integrated. A clear distinction is made between fast control of turbine torque, which is a peculiarity of wind turbines, and slow control of electric power, which is a traditional power system requirement.

Hinrichsen, E. N.↗

Pole placement and order reduction in two-time-scale control systems through Riccati iteration

A transformation of variables taken from singular perturbations may be applied to two-time-scale linear systems in state space form to reduce the system to block-diagonal form with slow and fast modes decoupled. The transformation is easily computed by applying the new Riccati iteration. The iteration yields a solution to the nonsymmetric algebraic Riccati equation obtained by partitioning the original system matrix A. The numerical procedure is initiated with the trivial iterate L(0) = 0, and is globally convergent to the desired unique time scale decoupling solution. After transformation, the decoupled system may be used in controller design to achieve exact closed loop pole placement in the slow subsystem without altering the poles of the fast subsystem. The decoupled form may also be used to reduce system order by wetting a small parameter to zero. Provided the fast subsystem is stable, the order reduction can be expected to yield a good approximation to the original system. These methods are demonstrated using the 16th order linear model of a turbofan engine.

Anderson, L. R.↗

Flight Investigation of a Normal-Acceleration Automatic Longitudinal Control System in a Fighter Airplane

A flight investigation was made to obtain experimental information on the handling qualities of a normal-acceleration type of automatic longitudinal control system. The control system was installed in a subsonic fighter-type airplane. In hands-off (stick-free) flight the normal-acceleration control system attempted to regulate the normal acceleration to a constant value which is dependent on the automatic-control-system trim setting. In maneuvering flight a given pilot's stick deflection produced a proportional change in normal acceleration, the change in acceleration being independent of flight condition. A small side-located controller stick was used by the pilot to introduce signals into the automatic control system. In the flight program emphasis was placed on the acceleration-limiting capabilities of the control system. The handling qualities were investigated in maneuvers such as slow and rapid pull-ups and turns and also in flight operations such as cruising, stalls, landings, aerobatics, and air-to-air tracking. Good acceleration limiting was obtained with the normal-acceleration control system by limiting the magnitude of the input signal that the pilot could introduce into the control system. The same values of control-system gain settings could be used from an acceleration-limiting stand-point at both 10,000 and 30,000 feet for the complete speed range of the airplane. The response characteristics of the airplane-control system combination were also satisfactory at both high and low altitude with these same values of control-system gain setting. In the pilot's opinion, the normal-acceleration control system provided good stability and control characteristics in flight operations such as cruising, stalls, landings, aerobatics, and air-to-air tracking.

Sjoberg, S. A.↗

Enhancements and Deployment of the TDAQ System for the Mu2e Experiment

The Real Time Processing Systems Division at Fermilab has deployed new features to the Off-The-Shelf Data Acquisition framework (otsdaq) for the Mu2e experiment. The Mu2e experiment will search for the coherent neutrino-less conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement of 10,000 times over existing limits. Such a charged lepton flavor-violating reaction probes new physics at a scale unavailable at present or planned high-energy colliders. The Mu2e Trigger and Data Acquisition (TDAQ) system uses otsdaq as its online Data Acquisition System (DAQ) framework. otsdaq integrates the artdaq and art frameworks for event transfer, filtering, and processing. otsdaq is a web-based DAQ software suite focusing on flexibility and scalability and provides a multi-user interface accessible through a web browser. artdaq handles the entire data stream, which is read over the peripheral component interconnect express (PCIe) bus to a software filter algorithm that selects events combined with the data flux coming from a cosmic-ray veto (CRV) system. Detector front-ends are configured through the PCIe bus by customized otsdaq plugins. The otsdaq slow controls infrastructure has been further developed using the experimental physics and industrial control system (EPICS) open-source platform for monitoring, controlling, alarming, and archiving. The detector control system (DCS) for Mu2e has been integrated into otsdaq. The production TDAQ and DCS system has been deployed at the experimental hall and is being debugged and optimized for experiment operations. We report on the feature enhancements and deployment of otsdaq for Mu2e.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Transformational Natural Gas Fueled Dynamic SOFC for Data Center in-Rack Power (Final Technical Report)

Data centers consume 250TWh or 1% of global electricity use in 2019. This electricity demand is expected to grow exponentially in the future. The current data center power supply relies on electric grids with diesel engines and batteries as backup; the latter is critically important because a sudden loss of power could erase crucial data, causing catastrophic economic loss. However, such a double protection architecture is costly, inefficient and polluting. In search for better in-rack power system, fuel-cell based generators have recently emerged as a promising alternative to diesel engines and batteries because of its potential to be more cost-effective, more efficient and less polluting. Among many types of fuel cells, solid oxide fuel cells stand out to be a front runner because of their ability to directly operate on natural gas that has an existing infrastructure. However, there are several critical challenges facing SOFC generators to meet the rigorous power requirements of data centers: high cost, poor reliability and more importantly, slow response to the datacenters’ dynamic load change. The unexpected overload conditions in data centers can cause fuel starvation; the latter can initiate microcracks in the anode structure, thus jeopardizing the lifetime of the SOFC generator. The current efforts to increase transient power capabilities of traditional SOFCs and therefore protect SOFC stacks from internal damage during transient loading, rely primarily upon mathematical algorithms. One of the challenges to these control methodologies is the physical limitations of the fuel delivery system such as slow response of mass flow controllers to fast power demand.

30 DIRECT ENERGY CONVERSION↗