Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “single-phase distribution systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Elucidating Primary Degradation Mechanisms in High-Cycling-Capacity, Compositionally Tunable High-Entropy Hydrides

The hydrogen sorption properties of single-phase bcc (TiVNb) 100–x Cr x alloys (x = 0–35) are reported. All alloys absorb hydrogen quickly at 25 °C, forming fcc hydrides with storage capacity depending on the Cr content. Here, a thermodynamic destabilization of the fcc hydride is observed with increasing Cr concentration, which agrees well with previous compositional machine learning models for metal hydride thermodynamics. The steric effect or repulsive interactions between Cr–H might be responsible for this behavior. The cycling performances of the TiVNbCr alloy show an initial decrease in capacity, which cannot be explained by a structural change. Pair distribution function analysis of the total X-ray scattering on the first and last cycled hydrides demonstrated an average random fcc structure without lattice distortion at short-range order. If the as-cast alloy contains a very low density of defects, the first hydrogen absorption introduces dislocations and vacancies that cumulate into small vacancy clusters, as revealed by positron annihilation spectroscopy. Finally, the main reason for the capacity drop seems to be due to dislocations formed during cycling, while the presence of vacancy clusters might be related to the lattice relaxation. Having identified the major contribution to the capacity loss, compositional modifications to the TiVNbCr system can now be explored that minimize defect formation and maximize material cycling performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Nanoprecipitates to Enhance Radiation Tolerance in High-Entropy Alloys

The growth of advanced energy technologies for power generation is enabled by the design, development, and integration of structural materials that can withstand extreme environments, such as high temperatures, radiation damage, and corrosion. High-entropy alloys (HEAs) are a class of structural materials in which suitable chemical elements in four or more numbers are mixed to typically produce single-phase concentrated solid solution alloys (CSAs). Many of these alloys exhibit good radiation tolerance like limited void swelling and hardening up to relatively medium radiation doses (tens of displacements per atom (dpa)); however, at higher radiation damage levels (>50 dpa), some HEAs suffer from considerable void swelling limiting their near-term acceptance for advanced nuclear reactor concepts. In this study, we developed a HEA containing a high density of Cu-rich nanoprecipitates distributed in the HEA matrix. The Cu-added HEA, NiCoFeCrCu 0.12 , shows excellent void swelling resistance and negligible radiation-induced hardening upon irradiation up to high radiation doses (i.e., higher than 100 dpa). The void swelling resistance of the alloy is measured to be significantly better than NiCoFeCr CSA and austenitic stainless steels. Density functional theory simulations predict lower vacancy and interstitial formation energies at the coherent interfaces between Cu-rich nanoprecipitates and the HEA matrix. The alloy maintained a high sink strength achieved via nanoprecipitates and the coherent interface with the matrix at a high radiation dose (~50 dpa). From our experiments and simulations, the effective recombination of radiation-produced vacancies and interstitials at the coherent interfaces of the nanoprecipitates is suggested to be the critical mechanism responsible for the radiation tolerance of the alloy. Furthermore, the materials design strategy based on incorporating a high density of interfaces can be applied to high-entropy alloy systems to improve their radiation tolerance.

36 MATERIALS SCIENCE↗

A Report from the Thermal Science Research Center (TSRC)

A vertical flow loop was designed and assembled to determine the local (circumferential and axial) and mean wall temperature distributions for single-phase and two-phase (subcooled and saturated) downward flow in both uniformly-heated and single-side heated vertical channels. Freon-11 was used as the working fluid in order to directly relate and compare the results with a previous experimental campaign which employed this same working fluid. For a given steady-state experiment, the following parameters were held constant: (1) exit pressure, (2) inlet temperature, and (3) mass velocity. For a given configuration of the 2.2 m long cylindrical channel test section, which had a 1.2 m long heated section, the applied heat rate was varied from zero through successive quasi-steady states to a level which corresponded to localized film boiling in the test section. The measurements showed that the boiling curve changes significantly at higher mass velocities with respect to both the circumferential and axial directions. The slope of the boiling curve changes in a non-monotonic fashion with respect to the circumferential directions. The slope of the boiling curve changes in a non-monotonic fashion with respect to the circumferential direction. The measurements point to the existence of a dry-out phenomenon occurring at multiple levels of the applied heat for the single-side heated channel. In comparing the heat transfer for horizontal channel flow with a vertically downward flow, the results show that significantly lower heat transfer occurs in the horizontal flow. However, this trend reverses as both the Reynolds number and the applied heat rate increase. Both the Liu-Winterton and Shah correlations were compared with the experimental data. The Shah correlation predicted the uniformly heated tube data better. When a thermal hydraulic diameter approach was used for the single-side heated case, the data at upstream locations for Z/L less than 0.5 was bounded above by the Liu-Winterton correlation and below by the Shah correlation. At Z/L = 0.5, the Shah correlation bounded the data; and for Z/L greater than 0.5, both correlations overpredicted the data with the Shah correlation being closest to the data. The present results indicate that additional correlational development is needed. In addressing some of the advanced space thermal management objectives concerning accommodating high heat fluxes in non-uniformly heated systems, a large battery of experiments 88 have been completed where local two-dimensional wall temperature variations were measured for both single-phase and two-phase flow in a single-side heated circular tube. As noted above, the results show significant axial and circumferential variations. Accurately accounting for such variations can result in optimized future advanced space, enhanced (high heat flux) thermal management systems.

Boyd, Ronald D.↗

Destabilizing high-capacity high entropy hydrides via earth abundant substitutions: From predictions to experimental validation

The vast chemical space of high entropy alloys (HEAs) makes trial-and-error experimental approaches for materials discovery intractable and often necessitates data-driven and/or first principles computational insights to successfully target materials with desired properties. In the context of materials discovery for hydrogen storage applications, a theoretical prediction-experimental validation approach can vastly accelerate the search for substitution strategies to destabilize high-capacity hydrides based on benchmark HEAs, e.g. TiVNbCr alloys. Here, in this study, machine learning predictions, corroborated by density functional theory calculations, predict substantial hydride destabilization with increasing substitution of earth-abundant Fe content in the (TiVNb) 75 Cr 25-x Fe x system. The as-prepared alloys crystallize in a single-phase bcc lattice for limited Fe content x < 7, while larger Fe content favors the formation of a secondary C14 Laves phase intermetallic. Short range order for alloys with x < 7 can be well described by a random distribution of atoms within the bcc lattice without lattice distortion. Hydrogen absorption experiments performed on selected alloys validate the predicted thermodynamic destabilization of the corresponding fcc hydrides and demonstrate promising lifecycle performance through reversible absorption/desorption. This demonstrates the potential of computationally expedited hydride discovery and points to further opportunities for optimizing bcc alloy ↔ fcc hydrides for practical hydrogen storage applications.

36 MATERIALS SCIENCE↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Development of experimental and computational frameworks to predict subcooled flow boiling in the LANL Isotope Production Facility

Cooling is crucial to maintain the integrity of target systems in isotope production facilities. At Los Alamos National Laboratory (LANL)’s Isotope Production Facility (IPF), multiple encapsulated targets are stacked and irradiated in tandem with a 100 MeV, ~250μA proton beam. To facilitate effective heat removal, these stacked targets are separated and cooled via a series of water channels. At these beam currents, this high-energy proton beam heats the target system, likely initiating subcooled flow boiling in the cooling channels. However, in-beam monitoring of the IPF target system is not possible due to the extreme radiation environment, and the necessarily significant shielding. To better understand high-power target performance, we developed ex-situ experimental and computational frameworks to predict the behavior of subcooled flow boiling at IPF. Subcooled flow boiling experiments on Inconel 625 samples under IPF conditions (2 bar pressure, 10 GPM flow rate (i.e., 2249 kg/m 2 /s), 85 K subcooling) revealed that IPF's average operating power is at the early stage of boiling with a heat transfer coefficient of 48,000 W/m 2 /s. The proposed modeling framework enables us to predict a complete boiling curve, i.e., single-phase heat transfer, onset of nucleate boiling, two-phase heat transfer, and critical heat flux (CHF), with specification of input boiling parameters up to intermediate heat flux levels. The estimated CHF under IPF conditions is 5.2 MW/m 2 . Experimental data under reduced conditions (2 bar pressure, 1.5 GPM flow rate (i.e., 337 kg/m 2 /s), 45 K subcooling) served as validation cases for the computational modeling. This computational model can be further extended to more complicated systems replicating the real IPF configuration, for instance, to study void distribution as a function of the incident proton beam profile and coolant velocity profile of multiple cooling channels. Finally, the proposed experimental and computational frameworks provide a means to better understand cooling systems in the isotope production facilities at different accelerators, where in-beam monitoring of the cooling process is not available.

07 ISOTOPE AND RADIATION SOURCES↗

Deterministic Fabrication of Large-Area, High-Crystallinity Oxide Moiré Superlattices

Oxide twistronics extends moiré engineering beyond van der Waals materials, offering a promising platform for accessing emergent interfacial phenomena arising from the strong coupling of lattice, charge, and orbital degrees of freedom in complex oxides. However, deterministic fabrication of high-crystallinity oxide moiré superlattices over large lateral dimensions remains challenging due to the three-dimensional bonding network of oxides. Here, we demonstrate a scalable, generalized fabrication strategy that enables the formation of high-crystallinity oxide moiré superlattices with clean, chemically bonded interfaces and precisely controlled twist angles down to nominal values of 0.1°, achieving subdegree twist-angle accuracy across large contiguous lateral dimensions approaching the millimeter scale. Using NaNbO3 as a model system, we show that the resulting interlayer coupling drives pronounced structural reconstruction that modifies both the phase structure and ferroelectric domain configuration. Synchrotron-based X-ray 3D reciprocal space mapping reveals the emergence of a single-phase state in twisted bilayers, in contrast to the mixed-phase structure observed in single-layer membranes prior to twist assembly. The structural signatures are further consistent with gradual lattice rotation distributed along the thickness direction that may accommodate interfacial shear strain, distinct from reconstruction observed in van der Waals moiré systems which primarily occurs through in-plane stacking rearrangement. This collective lattice response is correlated with twist-dependent nanoscale electromechanical modulations observed by piezoresponse force microscopy. These results establish a scalable materials platform for oxide twistronics and support the implementation of twist-engineered functionalities in practical, macroscale device architectures.

Ghanbari, Reza [North Carolina State University (N↗

Deep Learning-enhanced Block-Diagram Modeling of Solar Power Systems

Data-driven models of power system inverter-based resources are desired to run simulations faster than with detailed electromagnetic transient models, to hide proprietary design details, to support control system design applications, and to aggregate the effects of distributed energy resources. This paper applies a customized Hammerstein Wiener framework to train block diagram models from thousands of electromagnetic transient simulations or experimental test records. The block diagram models integrate with larger grid simulations as voltagecontrolled current sources or current-controlled voltage sources for several simulators. Guidelines for block architecture and training are presented. Three-phase balanced, three-phase unbalanced, and single-phase examples all achieve an acceptable root mean square error of no more than 0.05 per-unit.

Mcdermott, Thomas E. [Private consulting company]↗

Ensuring Solution Uniqueness in Three-Phase Power System State Estimation

This paper is concerned with the issue of potential non-unique solutions in three-phase state estimation. Theory of observability analysis for positive sequence power system state estimation is based on certain assumptions that avoid possibility of multiple solutions. Also, it is shown that observability of a positive sequence network remains independent of the network parameters or the operating state. When extending single-phase observability analysis directly to the three-phase case, this paper considers the possibility of converging to multiple solutions, i.e. solution non-uniqueness, even for cases where state estimator successfully converges. The study illustrates via numerical examples the likelihood of converging to entirely different solutions for certain network parameters. It also examines how the operating state, particularly under unbalanced loading, leads to solution non-uniqueness. The paper then describes an alternative approach to ensure a unique solution in three-phase state estimation. This method aims to accurately and uniquely estimate the state of any unbalanced three-phase system, irrespective of load imbalance, network configuration, existence of synchronous generators or transformers.

Power System State Estimation, Three-Phase, Distri↗

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a novel statistical parameters based data driven approach for passive islanding detection. The proposed scheme relies in the voltage data, measured at the point of common coupling, and is comprised of three stages. The Stage-1 quickly detects what is termed as coarse islanding, Stage-2 computes the decaying DC detector (DDCD), and 3) finally, the digital relay logic (DRL) is devised in Stage-3. The proposed scheme is tested as per the IEEE-1547, UL 1741 and IEC-62116 standards. Various tests are investigated on the modified IEEE-13 bus system, modeled in PSCAD/EMTDC, under stringent test scenarios such as power mismatch, induction motor starting effect, capacitor bank switching and various level of loads changes, considered for both single and multiple DG systems. The test results reveal that the proposed scheme can detect islanding in less than 2 cycles, and results in nearly zero non detection zone (NDZ). Also, the scheme can very well be used for single-phase microgrids too as it relies only on the single phase voltage information.

anti-islanding protection↗

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a simple yet effective statistical parameters based passive islanding scheme. The proposed scheme relies only the voltage data, measured at the point of common coupling (PCC), and is comprised of three stages. The Stage-1 quickly computes what is termed as mean based coarse islanding detection (MID), Stage-2 computes the decaying DC detector (DDCD), and 3) finally, MID is used in conjunction with DDCD as per the statistical digital relay logic (SRDL) is devised in Stage-3 to distinguish between islanding events from non islanding events. Various tests are investigated on the Banshee's industrial Microgrid (MG), modelled in the Real Time Digital Simulator (RTDS), on the basis of the IEEE-1547, UL 1741 standards. The validation of the proposed islanding detection methodology (PIDM) in RTDS platform ensures the viability of the proposed scheme in practical systems. The test results reveal that the PIDM can detect islanding within 2 cycles, and results in a very small non detection zone (NDZ). Moreover, the scheme can very well be used for single-phase MG too as it relies only on the single phase voltage information.

anti-islanding protection↗

1 kV, 10-kW SiC-Based Quadruple Active Bridge DCX Stage in a DC to Three-Phase AC Module for Medium-Voltage Grid Integration

Interfacing low voltage dc to medium voltage three-phase ac grid is often based on series-stackable modular converter architectures. To minimize energy storage requirements, it is advantageous to employ a quadruple active bridge (QAB) stage operating as a "dc transformer" in each stackable module. The QAB stage offers three isolated dc link voltages, which then allow for flexible stacking of three single-phase dc-to-ac inverter stages. Each of the module phases processes a pulsating power having a component at twice the line frequency. This presents a challenge in maintaining zero voltage switching (ZVS) on the secondary sides of the QAB during low-power portions of the line cycle. This article is focused on the design of the QAB stage. A detailed analysis of ZVS switching waveforms is presented, including effects of nonlinear device capacitances. It is shown how ZVS can be achieved at all times using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. Analytical expressions are given for the optimal values of the magnetizing inductance and the dead times of the QAB primary and secondary bridges. This approach is verified by experimental results on a 1 kV, 10-kW SiC-based prototype, demonstrating a relatively flat efficiency curve with a peak efficiency of 97.1% at 75% load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

UNIFI's Grid-Forming (GFM) Inverter Reference Design: A Tutorial on Modeling, Control, and Experimental Implementation of GFM Inverters

The UNIFI Consortium's tutorial on grid-forming (GFM) inverters provides a comprehensive guide to the modeling, control, and experimental implementation of GFM inverters. As the integration of renewable energy accelerates, the transition from traditional grid following (GFL) to GFM inverters is crucial to ensure stable and sustainable power systems. This document outlines a reference design for three-phase and single-phase GFM inverters developed at the University of Texas at Austin. The tutorial also provides step-by-step guidance for accessing and using UNIFI’s GitHub repository, enabling users to design, build, and test GFM inverters efficiently. By fostering collaboration and equipping users with accessible resources, this initiative aims to drive widespread adoption of GFM technology across academia, utilities, and industries.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resonant AC power system proof-of-concept test program

Proof-of-concept testing was performed on a 20-kHz, resonant power system breadboard from 1981 through 1985. The testing began with the evaluation of a single, 1.0-kW resonant inverter and progressed to the testing of breadboard systems with higher power levels and more capability. The final breadboard configuration tested was a 25.0-kW breadboard with six inverters providing power to three user-interface modules over a 50-meter, 20-kHz bus. The breadboard demonstrated the ability to synchronize multiple resonant inverters to power a common bus. Single-phase and three-phase 20-kHz power distribution was demonstrated. Simple conversion of 20-kHz to dc and variable-frequency ac was demonstrated as was bidirectional power flow between 20-kHz and dc. Steady state measurements of efficiency, power-factor tolerance, and conducted emissions and conducted susceptibility were made. In addition, transient responses were recorded for such conditions as start up, shut down, load changes. The results showed the 20-kHz resonant system to be a desirable technology for a spacecraft power management and distribution system with multiple users and a utility-type bus.

Wappes, Loran J.↗

Mobile Centers For Secondary Power Distribution

Concept for distribution of 60-Hz ac power in large building devoted to assembly and testing of equipment improves safety, reduces number of outlets and lengthy cables, and readily accommodates frequent changes in operations and configuration. Power from floor recess fed via unobtrusive cable to portable power management center. A cart containing variety of outlets and circuit breakers, wheeled to convenient location near equipment to be assembled or tested. Power distribution system presents larger range of operational configurations than fixed location. Meets tighter standards to feed computers and delicate instruments. Industrial-grade power suitable for power tools and other hardware. Three-phase and single-phase outlets available from each.

Mears, Robert L.↗