Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor enabled coatings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves the resistance measurement of a thin film of niobium. During coating, the change in resistance reflects the conversion of the film to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the thickness, allowing for increased precision in future depositions.

Howard, K. [Unlisted] (ORCID:0000000325613308)↗

The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS)

EUNIS (Extreme Ultraviolet Normal Incidence Spectrograph) is a high-efficiency extreme ultraviolet spectrometer that is expected to fly for the first time in 2004 as a sounding rocket payload. Using two independent optical systems, EUNIS will probe the structure and dynamics of the inner solar corona high spectral resolution in two wavelength regions: 17-21 nm with 3.5 pm resolution and 30-37 nm with 7 pm resolution. The long wavelength channel includes He II 30.4 nm and strong lines from Fe XI-XVI; the short wavelength channel includes strong lines of Fe IX-XIII. Angular resolution of 2 arcsec is maintained along a slit covering a full solar radius. EUNIS will have 100 times the throughput of the highly successful SERTS payloads that have preceded it. There are only two reflections in each optical channel, from the superpolished, off-axis paraboloidal primary and the toroidal grating. Each optical element is coated with a high-efficiency multilayer coating optimized for its spectral bandpass. The detector in each channel is a microchannel plate image intensifier fiber- coupled to three 1K x 1K active pixel sensors. EUNIS will obtain spectra with a cadence as short as 1 sec, allowing unprecedented studies of the physical properties of evolving and transient structures. Diagnostics of wave heating and reconnection wil be studied at heights above 2 solar radii, in the wind acceleration region. The broad spectral coverage and high spectral resolution will provide superior temperature and density diagnostics and will enable underflight calibration of several orbital instruments, including SOHO/CDS and EIT, TRACE, Solar-B/EIS, and STEREO/EUVI. EUNIS is supported by NASA through the Low Cost Access to Space Program in Solar and Heliospheric Physics.

Oegerle, William↗

Next-generation wildlife tracking devices and integrated sensors for measuring species-environment interactions and advancing conservation

Global land use and climate change have magnified the importance of collecting accurate animal movement and environmental data to improve our ability to model species interactions with the environment and promote effective conservation. Advanced animal tracking devices that couple cutting-edge technologies with our expanding need for ecological information is critical. In addition to further optimizing device size to monitor small, sensitive species, new paradigms for collecting, storing, and transmitting data about animals and their environments will propel wildlife tracking devices forward. Advanced telemetry capabilities will increase our ability to pair location and sensor data from tagged wildlife with remote sensing data. The USGS Western Ecological Research Center, NASA Ames Research Center, and collaborators have been developing new wildlife tracking devices and integrated environmental sensors to address these challenges. We describe a new, miniaturized solar GPS-enabled Globalstar satellite transmitter with accelerometer capability that is 20% lighter and 25% less expensive than existing commercially available tags. We also introduce a novel peer-to-peer, solar-powered network tag that uses long-range, low-power, wireless platform technology. Concurrently, we began adapting a carbon nanotube (CNT) sensor to detect dimethyl sulfide (DMS), a trace gas relevant to marine ecology and climate studies. CNT sensors offer a small, lightweight, and low-power technology that can detect changes in resistance across carbon nanotubes coated with adsorbent selected to specifically bind with a variety of reactive trace gasses. We flew a prototype sensor in a small UAS and sampled an apparent increase in DMS concentration consistent with a well-defined marine frontal boundary. Currently we are integrating project components to create a hybridized architecture of networked peer-to-peer and satellite tags with integrated CNT and additional on-board and remote sensors to advance animal tracking and to provide information for next generation wildlife conservation.

Ian G. Brosnan↗

Facilitating Large‐Scale Snow Shedding from In‐Field Solar Arrays using Icephobic Surfaces with Low‐Interfacial Toughness

Abstract Large‐scale accrual of snow and ice on solar arrays in northern latitudes can cause significant power generation losses during winter. Depending on environmental conditions, snow can encompass a wide range in physical characteristics from dry snow (modulus ≈100 kPa and density ≈0.1 g cm −3 ) to bulk ice (modulus ≈8 GPa and density ≈0.9 g cm −3 ). This variation in snow morphology has made the development of a passive, broad‐spectrum, snow and ice‐shedding surface challenging. Here, the authors develop one of the first surfaces that simultaneously possesses both low‐interfacial strength ( τ˄ ice < 50 kPa) and toughness (Γ ice < 0.5 J m −2 ) with ice. These surfaces, fabricated via the addition of mobile polymer chains/oils to a thin polymeric coating, require extremely low detachment forces for ice, enabling its passive shedding at virtually any accretion length scale. Preliminary evidence that the new surfaces can shed different forms of snow and ice from field‐deployed solar arrays, over a range of subzero temperatures for several weeks, leading to significant increases in power generation is provided. The optically transparent surfaces are easily scalable and can be widely deployed by the solar industry in areas that see persistent snow. Other applications include automotive windshields, LIDAR covers for autonomous vehicles, and cold climate optical sensors.

Dhyani, Abhishek↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves a four-point resistance measurement of a thin film of niobium, inside the coating region. During coating, the change in resistance reflects the conversion of the film from Nb to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the Nb3Sn film thickness, allowing for increased precision in future depositions for cavity applications.

Howard, K. [Chicago U.] (ORCID:0000000325613308)↗

Continuous Fiber Bath Treatments at Pilot Scale: A Novel Testbed System

The technical demands on high performance textiles continues to expand, and the research community has answered the call with innovative fiber bath treatments for enhanced properties and sizings for improved composites. However, little translation to greater scale has been demonstrated. To fill this gap, a novel, multifunctional system has been developed to explore polymer fiber treatment methods, the deployment of nanoadditive coatings and other sizings, and smart processing methods at the pilot scale. Continuous tows of fibers can be passed through a temperature-controlled, crossflow bath with an immersion residence time exceeding 2 hours. The modular system is resistant to corrosive solutions, includes additional inline stations for washing and drying after processing, is equipped with a bevy of sensors, pumps, and valves monitored and controlled by a LabView program, and can be fully contained in a standard lab fume hood. This new testbed system, when coupled with high fidelity materials characterization methods, will enable rapid evaluation of new fiber treatment methods at pilot-scale.

36 MATERIALS SCIENCE↗

Orientation matters: Measuring the correct surface of polyamide membranes with quartz crystal microbalance

The surface of polyamide reverse osmosis (RO) membranes which regulates interface-dominated phenomena, such as partitioning and fouling, is the one facing the feed during operation. However, the opposite surface of the polyamide selective layer, the one facing the permeate and in contact with the polysulfone porous support, is commonly analyzed in quartz crystal microbalance (QCM) measurements due to limitations of state-of-the-art transfer methodologies. Such measurements on the back surface cannot be generalized because the polyamide layer is chemically and morphologically asymmetric. Herein, we introduce a simple method to coat QCM sensors with polyamide active layers in the correct orientation (i.e., exposing their front surface) and show that interface-dominated phenomena differ significantly between orientations. We start by describing a transfer protocol to coat any surface with a polyamide layer on its front surface orientation. We then systematically analyze the chemical and morphological differences between the two surfaces of the polyamide layer of a commercial RO membrane. Finally, we demonstrate that interface-dominated phenomena depend on the orientation by showing that NaCl partitioning at pH 6 was 1.3 to 2.3-fold higher on the front surface and that organic fouling with humic acid occurred at a lower rate on this surface. The new method presented herein enables measurements on the front surface of polyamide RO membranes, which should be the standard in any future QCM studies.

Fouling behavior↗

A Multi-Sensor, Low Volume, Automated Culture System for Space Biology Experiments

Optical density (absorbance) is commonly used in microbiology to measure cell concentration and other colorimetric indicators. It is the main type of bioscience data returned from the BioSentinel small spacecraft mission, which was recently launched as a secondary payload on Artemis I. The flight unit takes absorbance measurements of yeast cultures at 570 nm, 630 nm, and 850 nm to track cell concentration and oxidation-reduction (redox) state of the metabolic indicator dye alamarBlue over time [1]. Because the data returned from a small spacecraft mission is necessarily limited, BioSentinel uses a specialized ground-based experiment apparatus to map the absorbance data onto several other parameters. This culture apparatus is composed of a polycarbonate base and lid which contain ports for several commercial sensors, including a standard 12 mm dissolved oxygen probe, gaseous CO2, fluid pressure, and two micro-probes for measuring pH and redox potential. It also contains a pressure relief valve, a rubber membrane for culture interaction, and a 12mm port for the custom optical probe designed to match in-flight measurements. Modules in two corners expand the culture volume into narrow columns, enabling solid-state optical density measurement and dielectric spectroscopy. The apparatus can be fit to a plate for magnetic stirring. The apparatus’s optical probe allows mapping between the flight unit’s optical data and the additional parameters measured by the ground-based experiments. Within the probe, a linear actuator pulls a plunger, drawing culture volume into the optical path. The actuator then pushes out the plunger and culture volume, cleaning any stray yeast from the inside surface of the probe. The probe chassis is 3D-printed from biocompatible resin with the optoelectronics cured inside an optically clear conformal coat which functions as a lens. To optimize the probe’s dimensions, including optical path, a test harness was developed to manipulate and measure distance while the LED light sources and photodiode detector are in operation. The test harness was composed of two 3/64” thick polycarbonate plates mounted to a set of calipers. The LEDs and photodiode were mounted on the outside of each plate. A cuvette of sample fluid was then clamped between the plates in line between the LEDs and photodiode. The test harness generated a 78% signal change between water and a dye standard for the green (570 nm) LED, a 90% signal change for the red (630 nm) LED, and a 25% signal change between water and overgrown yeast for the infrared (850 nm) LED. The improvements to the ground experiment apparatus (culture volume reduction, inclusion of an optical probe to measure flight-like optical data, and magnetic stirring for culture homogeneity) allow for more flight-like measurements to be taken and more accurate mapping of these additional parameters to the optical data returned from the flight unit. This enhancement to mission science return will give insight into how deep space radiation may affect human biology for future long-term space exploration.

Multi-Sensor↗

Membrane potential sensing: Material design and method development for single particle optical electrophysiology

We review the development of “single” nanoparticle-based inorganic and organic voltage sensors, which can eventually become a viable tool for “non-genetic optogenetics.” The voltage sensing is accomplished with optical imaging at the fast temporal response and high spatial resolutions in a large field of view. Inorganic voltage nanosensors utilize the Quantum Confined Stark Effect (QCSE) to sense local electric fields. Engineered nanoparticles achieve substantial single-particle voltage sensitivity (~2% Δλ spectral Stark shift up to ~30% ΔF/F per 160 mV) at room temperature due to enhanced charge separation. A dedicated home-built fluorescence microscope records spectrally resolved images to measure the QCSE induced spectral shift at the single-particle level. Biomaterial based surface ligands are designed and developed based on theoretical simulations. The hybrid nanobiomaterials satisfy anisotropic facet-selective coating, enabling effective compartmentalization beyond non-specific staining. Self-spiking- and patched-HEK293 cells and cortical neurons, when stained with hybrid nanobiomaterials, show clear photoluminescence intensity changes in response to membrane potential (MP) changes. Organic voltage nanosensors based on polystyrene beads and nanodisk technology utilize Fluorescence (Förster) Resonance Energy Transfer (FRET) to sense local electric fields. Voltage sensing FRET pairs achieve voltage sensitivity up to ~35% ΔF/F per 120 mV in cultures. Non-invasive MP recording from individual targeted sites (synapses and spines) with nanodisks has been realized. However, both of these QCSE- and FRET-based voltage nanosensors yet need to reach the milestone of recording individual action potentials from individual targeted sites.

59 BASIC BIOLOGICAL SCIENCES↗

NASA Tech Briefs, February 2014

Topics include: JWST Integrated Simulation and Test (JIST) Core; Software for Non-Contact Measurement of an Individual's Heart Rate Using a Common Camera; Rapid Infrared Pixel Grating Response Testbed; Temperature Measurement and Stabilization in a Birefringent Whispering Gallery Resonator; JWST IV and V Simulation and Test (JIST) Solid State Recorder (SSR) Simulator; Development of a Precision Thermal Doubler for Deep Space; Improving Friction Stir Welds Using Laser Peening; Methodology of Evaluating Margins of Safety in Critical Brazed Joints; Interactive Inventory Monitoring; Sensor for Spatial Detection of Single-Event Effects in Semiconductor-Based Electronics; Reworked CCGA-624 Interconnect Package Reliability for Extreme Thermal Environments; Current-Controlled Output Driver for Directly Coupled Loads; Bulk Metallic Glasses and Matrix Composites as Spacecraft Shielding; Touch Temperature Coating for Electrical Equipment on Spacecraft; Li-Ion Electrolytes Containing Flame-Retardant Additives; Autonomous Robotic Manipulation (ARM); CARVE Log; Platform Perspective Toolkit; Convex Hull-Based Plume and Anomaly Detection; Pre-Filtration of GOSAT Data Using Only Level 1 Data and an Intelligent Filter to Remove Low Clouds; Affordability Comparison Tool - ACT; "Ascent - Commemorating Shuttle" for iPad; Cassini Mission App; Light-Weight Workflow Engine: A Server for Executing Generic Workflows; Model for System Engineering of the CheMin Instrument; Timeline Central Concepts; Parallel Particle Filter Toolkit; Particle Filter Simulation and Analysis Enabling Non-Traditional Navigation; Quasi-Terminator Orbits for Mapping Small Primitive Bodies; The Subgrid-Scale Scalar Variance Under Supercritical Pressure Conditions; Sliding Gait for ATHLETE Mobility; and Automated Generation of Adaptive Filter Using a Genetic Algorithm and Cyclic Rule Reduction.

Source record↗

Multifunctional fiber-reinforced composites for passive sensing and energy harvesting with enhanced mechanical performance

Fiber-reinforced polymer composites (FRPCs) are valid alternatives to metals, especially in the aerospace industry, for their superior strength-to-weight ratio. FRPCs are generally manufactured by stacking layers of fibers and infusing them with epoxy-based adhesives to result in laminates. Such layer-by-layer structure often ensues a poor interlaminar property of the composites. Additionally, FRPCs can sustain complex damage modes because of their inherent anisotropic characteristics. For example, delamination can occur due to low-velocity impact at a subsurface level, which can result in premature catastrophic failures if undetected. Thus, structural monitoring is crucial to identify such damage. Point-based sensors (e.g., strain gauges, accelerometers, among many) can be embedded in the FRPCs for structural monitoring. However, their electrical power demand often embroils their usage. Therefore, the main objective of this research is to design and implement multifunctional composites that can simultaneously perform passive sensing and energy harvesting while exhibiting better mechanical performance. Previous research efforts have demonstrated that a continuous feed-through deposition of functional materials on fiber surfaces simultaneously enhanced the mechanical and sensing properties of the FRPCs. This study explores a similar approach to encode passive sensing and energy harvesting properties in the FRPCs by integrating ferroelectric microparticles on the fiber surfaces. Upon ensuring their superior interlaminar shear strength, sensing and energy harvesting properties were characterized through experimental studies. The outcome is a multifunctional composite fabricated by coating the fibers with functional microparticles through a high throughput, scalable, and low-cost approach that enables passive sensing, energy harvesting, and improved mechanical performance.

Gupta, Sumit↗

Additive manufacturing enabled hot-wire apparatus with suppressed edge effect error

This invention describes a method of structuring a metal or metal coated wire in a manner such that it provides enhanced accuracy when used in a hot-wire apparatus for transient thermal conductivity measurements for low-density materials. This is accomplished by using a diameter varying structure with two ends of the wire of sufficiently small diameter that the edge-effect induced error can be reduced by generating a more uniform temperature profile along the wire, whereas in conventional apparatus the temperatures always drop at the ends of a finite wire due to its ends that are being cooled by the wire-supports.

36 MATERIALS SCIENCE↗

An Overview of SHERLOC Raman and Fluorescence Spectroscopy Results Obtained During Perseverance’s Green Zone Campaign at Jezero Crater, Mars

The Perseverance rover landed in Jezero crater, Mars, in February 2021. The field site was chosen because orbiter data provided evidence that the crater hosted an ancient (>2.7 Ga) fluvio-lacustrine environment. The Octavia E. Butler landing site is located ~1.9 km east of the erosional remnant of the Jezero river delta. Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is an arm-mounted instrument that combines fluorescence and Raman spectroscopy with microscopic imaging to analyze geological materials in order to better understand the history of the environments recorded in the rocks within Jezero crater and to search for potential biosignatures. SHERLOC has two microscopic cameras, the Autofocus and Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering, (WATSON). These subsystems obtain high spatial resolution (10.1–100 µm/pixel) images to identify grain-scale structure and texture. SHERLOC spectroscopy enables high-sensitivity detection, characterization, and spatially-resolved correlation of trace organic materials. SHERLOC’s 248.6 nm deep UV laser generates a 100 µm-diameter spot. Photons generated by Raman scattering and fluorescence emission are collected and the spectra are downlinked to Earth for analysis. Knowledge of where the laser is pointed allows for mineral and compositional maps to be generated and overlain in ACI and WATSON images. Early spectroscopy observations focused on natural rock surfaces at targets named Nataani (sol 83), Bi_la_sana (sol 98) and Foux (sol 141). These surfaces included patches of aeolian dust that had settled upon the rocks. Perseverance’s abrasion tool is expected to become available in August 2021; it will grind to depths of 14 mm to remove dust and penetrate coatings and weathering rinds. This presentation will summarize major results from analysis of the rocks examined by SHERLOC during Perseverance’s first science and sample coring campaign (Green Zone Campaign).

Luther W Beegle↗

Electrochemical Detection of Oxycodone and Its Main Metabolites with Nafion-Coated Single-Walled Carbon Nanotube Electrodes

Oxycodone is a strong opioid frequently used as an analgesic. Although proven efficacious in the management of moderate to severe acute pain and cancer pain, use of oxycodone imposes a risk of adverse effects such as addiction, overdose, and death. Fast and accurate determination of oxycodone blood concentration would enable personalized dosing and monitoring of the analgesic as well as quick diagnostics of possible overdose in emergency care. However, in addition to the parent drug, several metabolites are always present in the blood after a dose of oxycodone, and to date, there is no electrochemical data available on any of these metabolites. In this paper, a single-walled carbon nanotube (SWCNT) electrode and a Nafion-coated SWCNT electrode were used, for the first time, to study the electrochemical behavior of oxycodone and its two main metabolites, noroxycodone and oxymorphone. Both electrode types could selectively detect oxycodone in the presence of noroxycodone and oxymorphone. However, we have previously shown that addition of a Nafion coating on top of the SWCNT electrode is essential for direct measurements in complex biological matrices. Therefore, in this work, the Nafion/SWCNT electrode was further characterized and used for measuring clinically relevant concentrations of oxycodone in buffer solution. The limit of detection for oxycodone with the Nafion/SWCNT sensor was 85 nM, and the linear range was 0.5–10 μM in buffer solution. Furthermore, this study shows that the fabricated Nafion/SWCNT sensor has potential to be applied in clinical concentration measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Longevity evaluation of SiC based alpha voltaic batteries with surface alpha sources

The alpha emitting actinide 241 Am is electrodeposited on the surface of the Pt electrode of in-house fabricated SiC Schottky diodes. With 17 nCi 241 Am directly coated on the top of a device, the 2-pi geometry yields a high energy (5.486 MeV) and a long-term irradiation accumulating to a high fluence (1.6 × 10 9 alpha particles’ infusion/month). The forward, reverse I/V, and dark current, are periodically measured to monitor key characteristics of device durability for any sign of degradation over time. The direct deposition of actinides on the surface of the device also enables the evaluation of radiation damage through alpha particles’ energy spectroscopic performance, which shows a clear spectrum degradation that can be reversed by optical excitation of the device prior to spectrum acquisition. As an analytical aide, the device performance is also simulated by Allpix 2 . Lastly, this study provides an insight into the durability of 4H-SiC as an energy converter option for alpha-voltaic batteries and the survivability in the other harsh environment found in nuclear fuel cycle, high energy physics, fission, fusion, and space exploration where rad-hard sensors are required.

Americium↗

Actuated Hybrid Mirror Telescope

The figure depicts the planned Actuated Hybrid Mirror Telescope (AHMT), which is intended to demonstrate a new approach to the design and construction of wide-aperture spaceborne telescopes for astronomy and Earth science. This technology is also appropriate for Earth-based telescopes. The new approach can be broadly summarized as using advanced lightweight mirrors that can be manufactured rapidly at relatively low cost. More specifically, it is planned to use precise replicated metallic nanolaminate mirrors to obtain the required high-quality optical finishes. Lightweight, dimensionally stable silicon carbide (SiC) structures will support the nanolaminate mirrors in the required surface figures. To enable diffraction- limited telescope performance, errors in surface figures will be corrected by use of mirror-shape-control actuators that will be energized, as needed, by a wave-front-sensing and control system. The concepts of nanolaminate materials and mirrors made from nanolaminate materials were discussed in several previous NASA Tech Briefs articles. Nanolaminates constitute a relatively new class of materials that can approach theoretical limits of stiffness and strength. Nanolaminate mirrors are synthesized by magnetron sputter deposition of metallic alloys and/or compounds on optically precise master surfaces to obtain optical-quality reflector surfaces backed by thin shell structures. As an integral part of the deposition process, a layer of gold that will constitute the reflective surface layer is deposited first, eliminating the need for a subsequent and separate reflective-coating process. The crystallographic textures of the nanolaminate will be controlled to optimize the performance of the mirror. The entire deposition process for making a nanolaminate mirror takes less than 100 hours, regardless of the mirror diameter. Each nanolaminate mirror will be bonded to its lightweight SiC supporting structure. The lightweight nanolaminate mirrors and SiC supporting structures will be fabricated from reusable master molds. The mirror-shape-control actuators will be low-power, high-capacitance lead magnesium niobate electrostrictive actuators that will be embedded in the SiC structures. The mode of operation of these actuators will be such that once power was applied, they will change in length and once power was removed, they will maintain dimensional stability to nanometer precision. This mode of operation will enable the use of low-power, minimally complex electronic control circuitry. The wave-front-sensing and control system will be designed and built according to a two-stage architecture. The first stage will be implemented by a Shack- Hartmann (SH) sensor subsystem, which will provide a large capture range. The second, higher-performance stage will be implemented by an image-based wave-front-sensing subsystem that will include a phase-retrieval camera (PRC), and will utilize phase retrieval and other techniques to measure wavefront error directly. Phase retrieval is a process in which multiple images of an unresolved object are iterated to estimate the phase of the optical system that acquired the images. The combination of SH and phase-retrieval sensors will afford the virtues of both a dynamic range of 105 and an accuracy of <10 nm.

Hickey, Gregory↗

Distributed Capacitive Sensor for Sample Mass Measurement

Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.

Toda, Risaku↗