Power system characteristics for more electric aircraft

It should not be suprising that more electric aircraft must meet significantly more difficult electrical power system requirements than were considereed when today's power distribution systems were being developed. Electric power, no longer a secondary system, will become a critical element of the primary control system. Functional reliability requiirements will be extremely stringent and can only be met by controlling element redundancy within a distributed power system. Existing electrical systems were not developed to have both the power system and the control/sensing elements distributed and yet meet the requirements of lighting tolerance and high intensity radio frequency (HIRF). In addition, the operation of electric actuators involves high transient loading and reverse energy flows. Such phenomena were also not anticipated when power quality was specified for either 270 vdc or 400 Hertz ac power systems. This paper will expand upon the issues and discuss some of the technologies involved in their resolution.

Hansen, Irving G.↗

Roadmap for Advancement of Low-Voltage Secondary Distribution Network Protection

Downtown low-voltage (LV) distribution networks are generally protected with network protectors that detect faults by restricting reverse power flow out of the network. This creates protection challenges for protecting the system as new smart grid technologies and distributed generation are installed. This report summarizes well-established methods for the control and protection of LV secondary network systems and spot networks, including operating features of network relays. Some current challenges and findings are presented from interviews with three utilities, PHI PEPCO, Oncor Energy Delivery, and Consolidated Edison Company of New York. Opportunities for technical exploration are presented with an assessment of the importance or value and the difficulty or cost. Finally, this leads to some recommendations for research to improve protection in secondary networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An interstellar precursor mission

A mission out of the planetary system, launched about the year 2000, could provide valuable scientific data as well as test some of the technology for a later mission to another star. Primary scientific objectives for the precursor mission concern characteristics of the heliopause, the interstellar medium, stellar distances (by parallax measurements), low-energy cosmic rays, interplanetary gas distribution, and the mass of the solar system. Secondary objectives include investigation of Pluto. The mission should extend to 400-1000 AU from the sun. A heliocentric hyperbolic escape velocity of 50-100 km/sec or more is needed to attain this distance within a reasonable mission duration (20-50 years). The trajectory should be toward the incoming interstellar gas. For a year 2000 launch, a Pluto encounter and orbiter can be included. A second mission targeted parallel to the solar axis would also be worthwhile. The mission duration is 20 years, with an extended mission to a total of 50 years. A system using one or two stages of nuclear electric propulsion (NEP) was selected as a possible baseline. The most promising alternatives are ultralight solar sails or laser sailing, with the lasers in earth orbit, for example. The NEP baseline design allows the option of carrying a Pluto orbiter as a daughter spacecraft.

Jaffe, L. D.↗

Spacecraft 2000

The Spacecraft 2000 program has been conceived by NASA with the objective to maintain the U.S. in a strong technical position in the space arena. The program is to involve a cooperative NASA/industry effort with long-range technology development aims. The technology areas addressed are related to spacecraft power, spacecraft energy storage, power management and distribution, autonomous operation-control, onboard systems integration, secondary propulsion, communications technologies, and systems/subsystems technology verification. Aspects of Spacecraft 2000 interactions with industry are discussed, taking into account visitations of NASA personnel to selected industrial concerns, most critical concerns (general), major technical concern, technology drivers for future spacecraft power systems, technology considerations for secondary propulsion, and questions of commercialization. Plans related to a Spacecraft 2000 program formulation are also considered.

Faymon, K. A.↗

Influence of Inverter-Based Resources on Microgrid Protection: Part 1: Microgrids in Radial Distribution Systems

Microgrids are being deployed at a rising rate, primarily as a means of increasing power system resilience. Commonly, a microgrid today includes at least some inverter-based resources (IBRs), and many microgrids have modes or conditions under which they are entirely energized by IBRs. Also, most microgrids today are deployed on radial distribution circuits, but it is conceivable that they could also be considered for deployment on secondary network systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced secondary power system for transport aircraft

A concept for an advanced aircraft power system was identified that uses 20-kHz, 440-V, sin-wave power distribution. This system was integrated with an electrically powered flight control system and with other aircraft systems requiring secondary power. The resulting all-electric secondary power configuration reduced the empty weight of a modern 200-passenger, twin-engine transport by 10 percent and the mission fuel by 9 percent.

Hoffman, A. C.↗

A Simple Halogen-Free Magnesium Electrolyte for Reversible Magnesium Deposition through Cosolvent Assistance

Rechargeable Mg batteries are one of the most investigated polyvalent-metal storage batteries owing to the increased safety associated with the nondendritic nature of Mg electrodeposition, high volumetric capacity, and low cost. To realize the commercial applications of Mg batteries, there are still a number of challenges remaining unsolved, in particular, the lack of halogen free Mg electrolytes, as the use of the halogens remains a major limiting factor to achieving high voltage cathodes. The research presented here introduces an innovative approach to prepare a halogen-free Mg-based electrolyte in a simple, nonsynthetic method that can plate and strip Mg reversibly. Results suggest that by introducing a secondary amine cosolvent the magnesium bis(trifluoromethanesulfonyl)imide (Mg(TFSI) 2 ) salt can be easily dissolved into a wide array of polar but aprotic ether solvents. A systematic structural investigation of a representative Mg(TFSI) 2 electrolyte in the cosolvent systems with the secondary amine was performed using pair distribution function (PDF) analysis, single crystal diffraction analysis, and NMR. The experimental atomic scale understanding reveals an ion pair structure of Mg 2+ coordinated with six oxygen donors from the bis(trifluoromethanesulfonyl)imide (TFSI) anions and the THF solvent located in the first solvation shell. The as-formed neutral ion pair structure acts as the active component for reversible Mg deposition. We believe this new route of preparing Mg electrolytes can extend the current understanding of Mg electrolyte functionality for rechargeable Mg batteries and offers more guidance for the future electrolyte design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Microgrids in Resilient Distribution Systems With Reconfigurable Cyber-Physical Networks

Modern distribution systems energized by inverter-interfaced distributed generators (DGs) operate as coupled cyber-physical networks (C/P-networks), where the controllable components in the physical network (P-network) are coordinated through the cyber network (C-network). The concept of dynamic microgrids (MGs) operation has been adopted to enable distribution system autonomous operation with varying electric boundaries. To further enhance system operation resiliency and flexibility, dynamic MGs operation with reconfigurable C/P-networks is discussed in this work. An evaluation framework is proposed to assess the operational feasibility of distribution feeders with multiple inverter-based dynamic MGs and come out with possible restoration solutions in the context of cross-layer C/P-network reconfiguration. Furthermore, distributed controllers are developed for components with different operating characteristics to realize seamless system topology variations and provide coordinated secondary regulation in various operation modes. Furthermore, the proposed evaluation framework along with the developed distributed controller has been validated using a Hardware-in-the-Loop (HIL) real-time CPS testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing Distributed Functions in an Integrated Hazard Analysis

Large scale integration of today's aerospace systems is achievable through the use of distributed systems. Validating the safety of distributed systems is significantly more difficult as compared to centralized systems because of the complexity of the interactions between simultaneously active components. Integrated hazard analysis (IHA), a process used to identify unacceptable risks and to provide a means of controlling them, can be applied to either centralized or distributed systems. IHA, though, must be tailored to fit the particular system being analyzed. Distributed systems, for instance, must be analyzed for hazards in terms of the functions that rely on them. This paper will describe systems-oriented IHA techniques (as opposed to traditional failure-event or reliability techniques) that should be employed for distributed systems in aerospace environments. Special considerations will be addressed when dealing with specific distributed systems such as active thermal control, electrical power, command and data handling, and software systems (including the interaction with fault management systems). Because of the significance of second-order effects in large scale distributed systems, the paper will also describe how to analyze secondary functions to secondary functions through the use of channelization.

Morris, A. Terry↗

Towers: Critical Initial Infrastructure for the Moon, Such as a Power Module Support

Towers are an efficient structure commonly used to elevate systems against a gravity field, such as above the surface of a planet or the Moon. Towers can be used to elevate antennas, transmitters and sensors for communication, navigation, and observation infrastructure in support of surface operations. Near the Lunar poles, elevation of rotating solar panels enables nearly continuous panel illumination for solar power production despite the Sun remaining near the horizon year-round. Further, once technology is developed for tower assembly, this same technology can be extended to the assembly of a variety of structures including rocket blast containment shields, bridges, shelters, and habitats from either Earth-sourced or Lunar-sourced structural members. Environmental factors on the Lunar surface are vastly different than those found on Earth and have significant impact on the design of towers. Towers designed for the Lunar surface have no heritage nor Earth analog. The designs discussed herein are therefore breaking new ground creating a fundamentally new class of structures outside of current experience and intuition. The purpose of this paper is to: a) describe the unique environmental factors affecting tower design on the Lunar surface compared to Earth-based systems, b) evaluate two structural forms for the tower; telescoping tubes and an assembled truss, as well as c)provide recommendations on when each structural form is most suitable. A major contribution presented in the current paper is to provide parametric plots and supporting equations of mass and volume versus module power level and blanket height above the Lunar surface for the solar array application, to enable system level studies of optimum power module distribution and size. A secondary contribution are plots of the mass and volume of aluminum or structural glass required for assembled truss towers formed from Lunar derived structural members. An objective of achieving 1 MW of total power has been used to enable comparison of structural forms, because the total mass of solar arrays is consistent. It will be shown that for moderate module sizes, up to ~50 kW power modules, based on a telescoping tube tower have advantages, but for power modules from 50 kW to 200 kW an assembled truss tower can be created with half to one third of the tube tower mass. More significantly, when shipped from Earth, an assembled truss tower can be packed into 1/14th to 1/25th of the tube tower volume. Truss designs in the 100 kW to 200 kW range will be shown to be a favorable when assembled from either graphite-epoxy angles shipped from Earth or aluminum angles fabricated from Lunar materials. 50 kW towers are an attractive choice for both a telescoping or assembled tower with the solar arrays elevated 10 m above the Lunar surface, while increased solar array elevation favors 100 kW to 200 kW power modules.

assembly↗

Packaging and distributing ecological data from multisite studies

Studies of global change and other regional issues depend on ecological data collected at multiple study areas or sites. An information system model is proposed for compiling diverse data from dispersed sources so that the data are consistent, complete, and readily available. The model includes investigators who collect and analyze field measurements, science teams that synthesize data, a project information system that collates data, a data archive center that distributes data to secondary users, and a master data directory that provides broader searching opportunities. Special attention to format consistency is required, such as units of measure, spatial coordinates, dates, and notation for missing values. Often data may need to be enhanced by estimating missing values, aggregating to common temporal units, or adding other related data such as climatic and soils data. Full documentation, an efficient data distribution mechanism, and an equitable way to acknowledge the original source of data are also required.

Information Systems↗

Allocating Reserves in Active Distribution Systems for Tertiary Frequency Regulation

This paper proposes a cooperative game theory-based approach for reserve optimization to enable distributed energy resources (DERs) participate in tertiary frequency regulation. Tertiary frequency regulation schemes ensure that reserve requirements of primary and secondary frequency regulation are fulfilled with a minimum cost. While the available reserve from a single distribution system may not suffice tertiary frequency regulation, stacked reserve from several distribution systems can enable them participate in tertiary frequency regulation at scale. In this paper, a two-stage strategy is proposed to effectively and precisely allocate spinning reserve requirement from each DER in distribution systems. In the first stage, two types of characteristic functions are computed: worthiness index (WI) and power loss reduction (PLR). In the second stage, the equivalent Shapley values are computed based on the characteristic functions, which are used to determine distribution factors for reserve allocation among DERs. The effectiveness of the proposed method for allocating reserves among DERs is demonstrated through several case studies on modified versions of the IEEE 13-node and 33-node distribution systems.

Gautam, Mukesh↗

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flight, Wind-Tunnel, and Computational Fluid Dynamics Comparison for Cranked Arrow Wing (F-16XL-1) at Subsonic and Transonic Speeds

Geometrical, flight, computational fluid dynamics (CFD), and wind-tunnel studies for the F-16XL-1 airplane are summarized over a wide range of test conditions. Details are as follows: (1) For geometry, the upper surface of the airplane and the numerical surface description compare reasonably well. (2) For flight, CFD, and wind-tunnel surface pressures, the comparisons are generally good at low angles of attack at both subsonic and transonic speeds, however, local differences are present. In addition, the shock location at transonic speeds from wind-tunnel pressure contours is near the aileron hinge line and generally is in correlative agreement with flight results. (3) For boundary layers, flight profiles were predicted reasonably well for attached flow and underneath the primary vortex but not for the secondary vortex. Flight data indicate the presence of an interaction of the secondary vortex system and the boundary layer and the boundary-layer measurements show the secondary vortex located more outboard than predicted. (4) Predicted and measured skin friction distributions showed qualitative agreement for a two vortex system. (5) Web-based data-extraction and computational-graphical tools have proven useful in expediting the preceding comparisons. (6) Data fusion has produced insightful results for a variety of visualization-based data sets.

John E Lamar↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers: Preprint

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network--that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest--in the sense of electrical distance--from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for real-time operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗