Five-channel scanning radiometer Quarterly reports 17, 18, and 19, 15 Oct. 1964 - 15 Jul. 1965
Medium resolution infrared radiometer calibration
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Medium resolution infrared radiometer calibration
Purpose: To report the acute toxicities associated with pencil beam scanning proton beam radiation therapy (PBS) for whole pelvis radiation therapy in women with gynecologic cancers and the results of a dosimetric comparison of PBS versus intensity modulated radiation therapy (IMRT) plans. Methods and Materials: Eleven patients with posthysterectomy gynecologic cancer received PBS to the whole pelvis. The patients received a dose of 45 to 50.4 Gy relative biological effectiveness (RBE) in 1.8 Gy (RBE) daily fractions. Acute toxicity was scored according to the Common Terminology Criteria for Adverse Events, version 4. A dosimetric comparison between a 2-field posterior oblique beam PBS and an IMRT plan was conducted. The Wilcoxon signed rank test was used to assess the potential dosimetric differences between the 2 plans and PBS target coverage robustness relative to setup uncertainties. Results: The median patient age was 55 years (range 23-76). The primary site was cervical in 7, vaginal in 1, and endometrial in 3. Of the 11 patients, 7 received concurrent cisplatin, 1 each received sandwich carboplatin and paclitaxel chemotherapy, both sandwich and concurrent chemotherapy, and concurrent and adjuvant chemotherapy, and 1 received no chemotherapy. All patients completed treatment. Of the 9 patients who received concurrent chemotherapy, the rate of grade 2 and 3 hematologic toxicities was 33% and 11%, respectively. One patient (9%) developed grade 3 acute gastrointestinal toxicity; no patient developed grade ≥3 genitourinary toxicity. The volume of pelvic bone marrow, bladder, and small bowel receiving 10 to 30 Gy was significantly lower with PBS than with intensity modulated radiation therapy (P<.001). The target coverage for all PBS plans was robust relative to the setup uncertainties (P>.05) with the clinical target volume mean dose percentage received by 95% and 98% of the target volume coverage changes within 2% for the individual plans. Conclusions: Our results have demonstrated the clinical feasibility of PBS and the dosimetric advantages, especially for the low-dose sparing of normal tissues in the pelvis with the target robustness maintained relative to the setup uncertainties. Future studies with larger patient numbers are planned to further validate our preliminary findings.
Mutual impedance effects in electronically-scanned antenna arrays
Electronically scanned antenna array and beam scanning
This document provides a scanned version of a 1987 SAND report that was never formally published. However, this report was referenced within the MELCOR Reference Manual and, therefore, provides historical information and technical basis for the MELCOR code. This document is being made available to permit users of the MELCOR code access to the information. The title page has been edited to prevent any confusion with regards to the possible documentation identifiers, such as the SAND report number or the intended date of publication. Beyond these modifications, a cover, distribution, and back cover are prepended and appended to the document to conform to modern SAND report style guidelines. The first four chapters of this report were updated and released under the title "Fission Product Behavior During Severe LWR Accidents: Recommendations for the MELCOR Code System. Volume I" and were made available by the U.S. NRC through the Adams database under accession number ML19227A327. No prior release of the remaining content of this report has occurred.
We report the measurement of K *0 meson at midrapidity (|y|< 1.0) in Au+Au collisions at $\sqrt{s_{NN}}$ = 7.7, 11.5, 14.5, 19.6, 27 and 39 GeV collected by the STAR experiment during the RHIC beam energy scan (BES) program. The transverse momentum spectra, yield, and average transverse momentum of K *0 are presented as functions of collision centrality and beam energy. The K *0 /K yield ratios are presented for different collision centrality intervals and beam energies. The K *0 /K ratio in heavy-ion collisions are observed to be smaller than that in small system collisions (e+e and p+p). The K *0 /K ratio follows a similar centrality dependence to that observed in previous RHIC and LHC measurements. The data favor the scenario of the dominance of hadronic re-scattering over regeneration for K *0 production in the hadronic phase of the medium.
Nighttime lunar surface differential flux scans at 22 microns
4D scanning transmission electron microscopy (STEM) is experiencing a revolution both in terms of data size, and data veracity, as are many other areas of experimental data acquisition. This presents enormous opportunities to make new scientific discoveries, but is also hamstrung by aging software that is no longer fit for purpose. Experimental data acquisition platforms must make the same investments in software infrastructure that the simulation community made decades ago to take advantage of high-performance computing (HPC) if they hope to realize the full potential of the latest advances made in detector technology. This requires rethinking the design and deployment of hardware, moving away from small, fixed commodity computing capabilities with closed interfaces to open, modular, scalable systems designed for parallelism and throughput. The technical approach will leverage best-in-class open source technologies, and develop new approaches strategically to build an open source platform for experimental data acquisition targeting high data rate electron microscopy. The project will develop a software platform that uses the power and performance of modern HPC resources to ingest the large volume of data produced by electron microscopes using direct electron detectors. A set of configurable pipelines will be used to enable the processing to be tailored to the problem being investigated with builtin visualization of data at interactive rates. This project will leverage investments made by the DOE and other agencies to provide a powerful software platform for the experimental data community working with most powerful electron microscopes, such as 4D STEM detectors. It will create a platform that serves as a reference for the community. Permissive open source licensing will make the platform available to all, with a simple deployment strategy offering the ability to keep data close to where it is generated. This advanced software platform will require customization for each deployment, creating opportunities for software services that are typically offered to extend open source software platforms.
Magnetostrictively scanned interferometer for airborne recording of coronal temperatures during solar eclipse
Breadboard design of scanning celestial attitude determination system
Development and construction of automatic photometer scan and data system
We report a novel scanning probe electron energy spectrometer (SPEES) which combines a double toroidal analyzer with a scanning tunneling microscope to achieve both topography imaging and electron energy spectroscopy mapping of surface in situ. The spatial resolution of spectroscopy mapping is determined to be better than 0.7 ± 0.2 μm at a tip sample distance of 7 μm. Meanwhile, the size of the field emission electron beam spot on the surface is also measured, and is about 3.6 ± 0.8 μm in diameter. This unambiguously demonstrates that the spatial resolution of SPEES technique can be much better than the size of the incident electron beam.
We report a scanning optical spectrometer based on the use of a stretchable elastomeric reflective grating. The grating is obtained by supersonic cluster beam implantation of silver nanoparticles on polydimethylsiloxane previously grooved by molding to create a replica of a commercial digital versatile disk grating. The use of a stretchable grating allows the spectrometer spanning the whole optical wavelength range by solely extending the diffraction element by more than 100% of its original dimensions. The stretchable reflective optical grating shows excellent performances and stability upon thousands of stretching cycles. The use of this elastomeric element makes the optical layout and the mechanics of the spectrometer extremely simple and advantageous for those applications where spectral resolution is not a major requirement. As a proof of principle, we present the absorption spectrum of Rhodamine B in solution obtained by our spectrometer and compared to commercial instruments.
We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.
Optical tracking and detector system with fiber optics cone for Mariner B spacecraft
Fabrication and testing of antenna system for use with airborne range and orbit determination transponder stations - direction finding and digital switching systems, and phase shifter
Channel electron multipliers for cathode luminescent collection of topographic details
A series of ILS approaches using seven airline-rated Boeing 737 pilots in an FAA qualified simulator have been conducted. The test matrix included both manual and coupled approaches with and without atmospheric turbulence in Category II weather. A nonintrusive oculometer system was used to track the pilot's eye-point-of-regard throughout the approach. The results indicate that, in general, the pilots use a different scan technique for the manual and coupled conditions; however, the introduction of atmospheric turbulence does not greatly affect the scan behavior in either case. A comparison is made between the objective measures of the instrument scan (oculometer data) and the pilots' opinions of their instrument use. The data show a high degree of consistency among pilots for both the quantitative data and the qualitative data (pilots' opinions). However, there is a slightly lower agreement between the quantitative and qualitative measures.