Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “saving energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Integrated and Advanced Lighting Controls: The Next Frontier in Energy Savings?

Lighting energy use has significantly declined as a portion of overall building energy usage due largely to the uptake of more efficient light-emitting diode technology. Although the per unit cost of lighting controls has declined, the installation and use of lighting controls are low and the installation and use of advanced controls are abysmally low. Increased use of advanced and connected lighting controls, and the ability to integrate lighting with other building systems (e.g., heat and air, plug loads, miscellaneous loads) that make the building “smarter,” offer the potential for additional energy savings. Studies into the performance of new, advanced lighting control technologies in commercial buildings have generated new findings. Although each field evaluation has interesting results individually, an analysis of their collective findings across a spectrum of commercial building types will help establish the current state of the technology and implications related to market readiness. This paper will analyze results from available field evaluation studies (recently completed as well as ongoing) of retrofit sites and share findings and insights including: • The amount of energy savings that may be expected from these systems. • Cost effectiveness, monetization, and cost points of these systems. • Ideal characteristics of these systems the most viable. • Lessons learned from the installation, commissioning, and occupant response of these systems. The results will support Department of Energy research investments and help inform efficiency programs of the potential of these emerging technologies and how they may fit within the clean energy future.

Myer, Michael↗

Miscellaneous Electric Loads: Characterization and Energy Savings Potential

Over time, miscellaneous electric loads (MELs) are expected to increase both in magnitude and share of residential and commercial building energy consumption. This trend is most apparent in North America, but it is also occurring in Japan and Europe. However, the contribution of MELs to building energy use is not currently well understood, both because the products in this category are transforming rapidly and the definition and classification of MELs is ambiguous. This study estimated the national energy consumption of 36 MELs using best-available data and found them to comprise 12% of delivered electricity to the U.S. residential and commercial building sectors. If 26 of these MELs were replaced with the most energy-efficient product models available on the market, their energy consumption could be halved to 6% of delivered electricity. National energy models will better account for building energy consumption by incorporating the MELs data collected and analyzed for this study, leading to improved policy decisions.

Miscellaneous electric loads, Plug loads, Taxonomy↗

Demand reduction and energy saving potential of thermal energy storage integrated heat pumps [Réduction de la demande et potentiel d'économie d'énergie des pompes à chaleur avec stockage d'énergie thermique intégré]

A heat pump (HP) moves heat from a low-temperature source to a high-temperature sink with an input of energy. Often, one temperature body fluctuates with time (e.g., diurnal ambient temperature), causing the HP efficiency to vary. Integrating thermal energy storage (TES) into a HP system adds a third temperature body, enabling the HP to be advantageously coupled to any two: the application, the ambient, or the TES at strategic times. Although TES integration with HPs is an important emerging technology to lower energy consumption and decrease energy demand during critical times, the favorable circumstances for TES integration are poorly understood. Here, this paper establishes the energy reduction and demand reduction potential of TES-integrated HPs with both analytical and numerical HP models. All possible temperature arrangements are considered for HP-TES systems with two fixed temperature bodies (application and TES) and one variable temperature (ambient). Results show that overall energy savings are most attainable when the TES temperature is near the application temperature, whereas a large temperature difference between the TES and the application leads to the most peak demand reduction. The potential for overall energy savings increases as the magnitude of ambient temperature fluctuations increases.

25 ENERGY STORAGE↗

The effect of linear regression modeling approaches on determining facility wide energy savings

Holistic energy management system business practices, such as the framework detailed in ISO 50001 – Energy management system, requirements and guidance for use , are centrally based upon the concept of energy performance improvement. For the purposes of ISO 50001, energy performance improvement can be determined for boundaries and following a process that is best suited for the implementing organization. Many organization and government ISO 50001 based programs, including the United States Department of Energy Superior Energy Performance (SEP) program, find value in demonstrating organizational energy performance improvement as the difference in energy consumption between two time periods within physically defined facility-boundaries. To make the difference in energy consumption for the two time periods meaningful, the amount of energy consumed must be adjusted to account for relevant variables. Relevant variables, such as metrics of production and weather conditions, affect directly the amount of energy consumed but are independent of the facility’s energy performance. Therefore, it is crucial to adjust the observed energy consumption by the relevant variables identified by the facility, so that the energy savings resulted from the energy performance improvement actions can be isolated and determined, which is the purpose of this program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Saving Energy: A QuickStart Guide for Small/Medium Manufacturers

The Quick Start Guide aims to serve as an introduction to energy efficiency for small to medium manufacturers, explaining why energy management is important and achievable for all organizations, not just well-resourced, energy-intensive large organizations. It also makes connections to the tools and resources available from DOE to help small to medium manufacturers drive energy savings and sustain the progress. Finally, it provides a list of common energy efficiency opportunities for energy consuming systems such as steam, process heating, and motor-driven systems. Explore the guide to see how smaller manufacturing companies can get started with energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emerging Plug Load Management Technologies that Save Energy and Time

This fact sheet introduces two emerging technologies that could streamline plug load management (PLM) for increased energy savings for building owners: learning behavior algorithms (LBA) and automatic and dynamic load detection (ADLD). Plug loads are responsible for 47% of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them challenging to manage. PLM systems exist today that use smart plugs to meter and control devices at the outlet level, but their uptake has been relatively slow in part because of the significant labor required for installation and maintenance. LBA and ADLD may address these challenges and provide additional energy efficiency and nonenergy benefits.

Plug and process loads, PPL, plug loads, plug load↗

Energy Analysis: Ways to Save Energy and Reduce the Emissions in Wastewater Treatment Plants

The key of this study is to explore the primary energy consumers in wastewater treatment plants, which is considered as one of the major energy consumers, and introduces the best solution to save energy and reduce emissions in these facilities. This study is based on the energy assessment and analyses of eleven wastewater treatment plants. Through the investigation, it was found that plants can save up to 44,158 MWh of the energy consumption which is 47% from the total electricity consumption with a 17% reduction in the total utility bills and that about 2.5 million dollars cost savings after reviewing the currently facilitated energy system. Additionally, an average of five years' payback period resulted in most energy-saving recommendations. A vast potential of greenhouse gas emissions can be reduced with a total range reduction between 13 to 35 million kg of CO 2 based on the speed reduction percentage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Voltage Controller Saves Energy, Prolongs Life of Motors

In 1985, Power Efficiency Corporation of Las Vegas licensed NASA voltage controller technology from Marshall Space Flight Center. In the following years, Power Efficiency made patented improvements to the technology and marketed the resulting products throughout the world as the Performance Controller and the Power Efficiency energy-saving soft start. Soft start gradually introduces power to an electric motor, thus eliminating the harsh, violent mechanical stresses of having the device go from a dormant state to one of full activity; prevents it from running too hot; and increases the motor's lifetime. The product can pay for itself through the reduction in electricity consumed (according to Power Efficiency, within 3 years), depending on the duty cycle of the motor and the prevailing power rates. In many instances, the purchaser is eligible for special utility rebates for the environmental protection it provides. Common applications of Power Efficiency's soft start include mixers, grinders, granulators, conveyors, crushers, stamping presses, injection molders, elevators with MG sets, and escalators. The device has been retrofitted onto equipment at major department store chains, hotels, airports, universities, and for various manufacturers

Source record↗

Reactors Save Energy, Costs for Hydrogen Production

While examining fuel-reforming technology for fuel cells onboard aircraft, Glenn Research Center partnered with Garrettsville, Ohio-based Catacel Corporation through the Glenn Alliance Technology Exchange program and a Space Act Agreement. Catacel developed a stackable structural reactor that is now employed for commercial hydrogen production and results in energy savings of about 20 percent.

Source record↗

Existing Whole-House Solutions Case Study: Group Home Energy Efficiency Retrofit for 30% Energy Savings, Washington, D.C.

Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes – such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study’s results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

BA-PIRC↗

Innovative Open-Source Energy Software to Drive and Enable Energy Savings and Process Optimization

U.S. Department of Energy (DOE) energy system-analysis software tools have been used for years helping to identify over 170 TBTU/year of energy savings through the Save Energy Now “Energy Savings Assessment” and Better Plants “In-Plant Training” Programs. While most of the fundamental energy savings opportunities do not evolve much with time, computer technology never stops, leaving most of these software tools inoperable on modern computers.This has sparked an initiative to revitalize the DOE energy system analysis tools into a new, open-source, integrated software tool suite - MEASUR. Designed for industrial energy coordinators, engineers, utility-program implementers and individuals who are interested in improving system efficiency, MEASUR can aide users in identifying, assessing, and quantifying energy savings opportunities within pump, fan, process heating, steam, motors, and compressed air systems. In addition, the software contains over 40 equipment and property calculators for simple energy-related calculations and analyses.This paper will present a results comparison for each energy-consuming system using data from past DOE-sponsored energy assessments (to establish the accuracy of the savings algorithms) to validate and verify the accuracy of the energy and cost savings calculated by MEASUR. Additionally, an example highlighting 3rd-party development of the tool’s opensource framework into real-time sensor systems and efficiency-optimization will be presented.

Armstrong, Kristina↗

The Value of Regression Models in Determining Industrial Energy Savings

Determination of industrial facility energy savings is commonly undertaken to comply with legal requirements, meet sustainability goals, and quantify greenhouse gas emissions, cost savings, and as one way to demonstrate energy performance improvement per the requirements of an energy management system standard, such as ISO 50001. At their most basic level, energy savings are determined through a process of accounting for baseline and reporting period energy consumption followed by a calculation of energy savings as the difference in the levels of energy consumption between the two periods. The determination of industrial facility-wide energy savings can be undertaken in a wide variety of ways and in relation to energy performance improvement, energy savings can be expressed as any number of energy performance indicators (EnPIs). Energy savings values will vary depending upon if an absolute, intensity, or regression basis of calculation is selected for use. The use of one of the three basis of energy savings calculation will alter the relevance, meaning, and comparability of the resulting energy savings values To increase consistency in the determination of energy savings values, standards such as the International Performance Measurement and Verification Protocol (IPMVP), ISO 17747 – Determination of Energy Savings in Organization, and the U.S. Department of Energy (U.S. DOE) Superior Energy Performance (SEP) program Measurement and Verification Protocol (SEP M&V Protocol) have been published. Industrial facilities in the United States, Mexico, and Canada are certified to the U.S. DOE SEP program after becoming ISO 50001 certified and verification by a third party of calculated energy savings per the SEP M&V Protocol. This paper discusses some of the different meanings energy savings values will have when calculated by using the three different bases. Additionally, data from five SEP certified industrial facilities are used to calculate energy savings values using the three bases and compared as energy performance improvement percentage (EPI %) values. Discussion of why a large degree in variation in EPI % values are seen for any given set of data is provided. Ultimately, while each energy saving calculation basis has merit and can be used appropriately in its own context, the regression basis is shown to best translates energy savings values into contextualized energy performance improvement values by conveying comparable information regarding operational and behavioural improvements not otherwise observable with the absolute or intensity bases.

Therkelsen, Peter↗

Energy Saving Melting and Revert Reduction Technology (Energy SMARRT): Manufacturing Advanced Engineered Components Using Lost Foam Casting Technology

This project was a subtask of Energy Saving Melting and Revert Reduction Technology (Energy SMARRT) Program. Through this project, technologies, such as computer modeling, pattern quality control, casting quality control and marketing tools, were developed to advance the Lost Foam Casting process application and provide greater energy savings. These technologies have improved (1) production efficiency, (2) mechanical properties, and (3) marketability of lost foam castings. All three reduce energy consumption in the metals casting industry. This report summarizes the work done on all tasks in the period of January 1, 2004 through June 30, 2011. Current (2011) annual energy saving estimates based on commercial introduction in 2011 and a market penetration of 97% by 2020 is 5.02 trillion BTU's/year and 6.46 trillion BTU's/year with 100% market penetration by 2023. Along with these energy savings, reduction of scrap and improvement in casting yield will result in a reduction of the environmental emissions associated with the melting and pouring of the metal which will be saved as a result of this technology. The average annual estimate of CO2 reduction per year through 2020 is 0.03 Million Metric Tons of Carbon Equivalent (MM TCE).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-cost, highly transparent flexible low-e coating film to enable electrochromic windows with increased energy savings

Five Quads of energy are lost through windows annually in the U.S. Low-e coatings are increasingly employed to reduce the wasted energy. Most commonly, the low-e coating is an oxide material applied directly to the glass at high temperature. With over 100,000,000 existing homes, a retrofit product is crucial to achieve widespread energy savings. Low-e films, i.e. coatings on polymeric substrates, are now also available to meet this need. However, the traditional oxide materials and process is incompatible with low temperature plastics. Alternate high performing low-e films typically incorporate materials that limit visible transmission to 35% or less. Further, the cost is high. The objective of this award was to develop a retrofit, integrated low-e/electrochromic window film to dramatically reduce energy lost through windows. While field testing of state-of-the-art electrochromic (EC) windows show the energy savings are maximized if a low-e coating is used in conjunction with the EC, available low-e films have a low visible transmission (~70% or less) that limits the achievable clear state and therefore, appearance and energy savings potential. Comprehensive energy savings models were completed at Lawrence Berkeley National Lab (LBNL). A parametric approach was used to project energy usage for windows with a large range of low-e properties across all U.S. climate zones, without limiting the study to materials that had already been produced commercially or made in a lab. The model enables projection of energy savings for low-e films as well as integrated low-e/EC products. This project developed a novel low-e film, optimized for compatibility with EC windows, using low temperature, high deposition rate processes for the growth of low-e coatings on plastic films by microwave plasma enhanced chemical vapor deposition. Silica films with good density and optical properties were demonstrated at deposition rates as high as 130Å/sec. A simple bi-layer low-e stack of silica and a transparent conductive oxide demonstrated 90% visible transmission with high thermal infrared reflectivity characteristic of conventional low-e coatings. A slightly more complex stack provided high solar infrared reflection without sacrificing visible transmission or thermal infrared reflection. Successful completion of the effort produced a prototype integrated low-e, dynamic window film with characterized energy saving potential. Cost modeling for the passive bi-layer, low-e film projects a manufacturing cost of ~$0.50/ft2 for a plant with 10M ft2/yr capacity. The novel thin film processes developed here enable high deposition rate (low cost), optical quality oxide coatings at low temperatures. When combined with engineered materials, ITN’s coating will result in low-cost, low-e films that reflect a high degree of infrared radiation without substantially reducing the visible transmission. The resultant window film will improve the U-value and achieve SHGC improvements over bare glass. The new low-e coating will be particularly attractive when combined with an electrochromic film. Low-e coating design guided by energy savings modeling allows customization of the product for different climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗