Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Preventing Bio-Bloopers and XFEL Follies: Best Practices from your Friendly Instrument Staff

Serial Femtosecond Crystallography (SFX) at X-ray Free electron Lasers (XFELs) is a relatively new field promising to deliver unparalleled spatial and temporal resolution on biological systems and there dynamics. Over the past decade, though, there have been a handful of results that have truly delivered on these promises. Why? SFX has many paradigm shifting techniques not seen in typical structural biology arenas, such as creating a concentrated slurry of microcrystals rather than a handful of loopable prisms worthy of a catalog photo. Then taking that slurry and high speed jetting them towards the vacuum or helium interation region to destroy less than 1% of your sample and waste the other 99. The literature is full of techniques and methods promising to cure what ails your experiment, yet as an instrument scientist will tell you –and a first author might admit after a few drinks at the conference happy hour—is that there are a lot more failures than the success we published, results may vary. We will walk through a best practices on how to prepare your sample and chose a sample delivery technique that will amerliorate your studies rather than undermine your hardwork and hopefully lead to better experimental planning and execution, inching you closer to that scientific goal and that call from Stockholm. This will be written in a more editorialized fashion and is meant to give the reader an idea of what to try or how they should be thinking. Welcome to SFX, now what?

47 OTHER INSTRUMENTATION↗

Test and Validation of the Mars Science Laboratory Robotic Arm

The Mars Science Laboratory Robotic Arm (RA) is a key component for achieving the primary scientific goals of the mission. The RA supports sample acquisition by precisely positioning a scoop above loose regolith or accurately preloading a percussive drill on Martian rocks or rover-mounted organic check materials. It assists sample processing by orienting a sample processing unit called CHIMRA through a series of gravity-relative orientations and sample delivery by positioning the sample portion door above an instrument inlet or the observation tray. In addition the RA facilitates contact science by accurately positioning the dust removal tool, Alpha Particle X-Ray Spectrometer (APXS) and the Mars Hand Lens Imager (MAHLI) relative to surface targets. In order to fulfill these seemingly disparate science objectives the RA must satisfy a variety of accuracy and performance requirements. This paper describes the necessary arm requirement specification and the test campaign to demonstrate these requirements were satisfied.

manipulation↗

Rapid and efficient room-temperature serial synchrotron crystallography using the CFEL TapeDrive

Serial crystallography at conventional synchrotron light sources (SSX) offers the possibility to routinely collect data at room temperature using micrometre-sized crystals of biological macromolecules. However, SSX data collection is not yet as routine and currently takes significantly longer than the standard rotation series cryo-crystallography. Thus, its use for high-throughput approaches, such as fragment-based drug screening, where the possibility to measure at physiological temperatures would be a great benefit, is impaired. On the way to highthroughput SSX using a conveyor belt based sample delivery system – the CFEL TapeDrive – with three different proteins of biological relevance (Klebsiella pneumoniae CTX-M-14 β-lactamase, Nectria haematococca xylanase GH11 and Aspergillus flavus urate oxidase), it is shown here that complete datasets can be collected in less than a minute and only minimal amounts of sample are required.

36 MATERIALS SCIENCE↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray Emission Spectroscopy as an in Situ Diagnostic Tool for X-ray Crystallography of Metalloproteins Using an X-ray Free-Electron Laser

Serial femtosecond crystallography (SFX) using the ultrashort X-ray pulses from a X-ray free-electron laser (XFEL) provides a new way of collecting structural data at room temperature that allows for following the reaction in real time after initiation. XFEL experiments are conducted in a shot-by-shot mode as the sample is destroyed and replenished after each X-ray pulse, and therefore, monitoring and controlling the data quality by using in situ diagnostic tools is critical. To study metalloenzymes, we developed the use of simultaneous collection of X-ray diffraction of crystals along with X-ray emission spectroscopy (XES) data that is used as a diagnostic tool for crystallography, by monitoring the chemical state of the metal catalytic center. We have optimized data analysis methods and sample delivery techniques for fast and active feedback to ensure the quality of each batch of samples and the turnover of the catalytic reaction caused by reaction triggering methods. Here, we describe this active in situ feedback system using Photosystem II as an example that catalyzes the oxidation of H2O to O2at the Mn4CaO5active site. We used the first moments of the Mn Kβ1,3emission spectra, which are sensitive to the oxidation state of Mn, as the primary diagnostics. This approach is applicable to different metalloproteins to determine the integrity of samples and follow changes in the chemical states of the reaction that can be initiated by light or activated by substrates and offers a metric for determining the diffraction images that are used for the final data sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Liquid Jet Endstation for Hard X-ray Scattering and Spectroscopy at the Linac Coherent Light Source

The ability to study chemical dynamics on ultrafast timescales has greatly advanced with the introduction of X-ray free electron lasers (XFELs) providing short pulses of intense X-rays tailored to probe atomic structure and electronic configuration. Fully exploiting the full potential of XFELs requires specialized experimental endstations along with the development of techniques and methods to successfully carry out experiments. The liquid jet endstation (LJE) at the Linac Coherent Light Source (LCLS) has been developed to study photochemistry and biochemistry in solution systems using a combination of X-ray solution scattering (XSS), X-ray absorption spectroscopy (XAS), and X-ray emission spectroscopy (XES). The pump–probe setup utilizes an optical laser to excite the sample, which is subsequently probed by a hard X-ray pulse to resolve structural and electronic dynamics at their intrinsic femtosecond timescales. The LJE ensures reliable sample delivery to the X-ray interaction point via various liquid jets, enabling rapid replenishment of thin samples with millimolar concentrations and low sample volumes at the 120 Hz repetition rate of the LCLS beam. This paper provides a detailed description of the LJE design and of the techniques it enables, with an emphasis on the diagnostics required for real-time monitoring of the liquid jet and on the spatiotemporal overlap methods used to optimize the signal. Additionally, various scientific examples are discussed, highlighting the versatility of the LJE.

EXAFS↗

Mars Rover Sample Return mission delivery and return challenges

The Mars Rover Sample Return mission is a robotic exploration mission culminating in the return of atmospheric and surface samples from Mars to Earth. To accomplish this complex mission requires sophisticated autonomous systems for many time-critical operations associated with the delivery and return phases, since the round trip light times preclude Earth-based control of these operations. In addition, there are significant engineering and technology challenges to be addressed to meet the mission science and exploration objectives.

Cohen, Aaron↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

Autonomous Measurement of Electrochemical Redox Couples for In-Situ Characterization of Enceladus Plume Samples

A 3D-printed microfluidic electrochemical cell with integrated electrodes was developed to demonstrate autonomous in-situ electrochemical characterization of terrestrial seawater samples. The system is designed to extend the capabilities of the 2008 Phoenix Lander’s Wet Chemistry Laboratory (WCL) that analyzed the soluble chemistry of the Martian soil, by miniaturizing its fluidic architecture for analysis of µL-volume samples as expected from an Enceladus fly-by mission. The microfluidic device has a total fluid volume of 48 µL and includes dual channels each populated with 7 electrodes. Measurement of pH was measured using an iridium oxide electrode. Cyclic voltammetry with Au, Pt, and glassy carbon working electrodes was used to measure redox couples in synthetic seawater that contained inorganic and bio-organic molecules. Glassy carbon was found to have minimal risk of interference from constituents of synthetic seawater when measuring molecular organic redox species; however, care must be used to prevent interference due to potential oxidation or dissolution in the case of Au working electrodes. A completely autonomous end-to-end run including sample delivery was performed, to demonstrate the feasibility of microfluidic-based cyclic voltammetry measurements for in-situ characterization of redox couples in Ocean World samples.

Planetary Instruments↗

Solving protein structure from sparse serial microcrystal diffraction data at a storage-ring synchrotron source

In recent years, the success of serial femtosecond crystallography and the paucity of beamtime at X-ray free-electron lasers have motivated the development of serial microcrystallography experiments at storage-ring synchrotron sources. However, especially at storage-ring sources, if a crystal is too small it will have suffered significant radiation damage before diffracting a sufficient number of X-rays into Bragg peaks for peak-indexing software to determine the crystal orientation. As a consequence, the data frames of small crystals often cannot be indexed and are discarded. Introduced here is a method based on the expand–maximize–compress (EMC) algorithm to solve protein structures, specifically from data frames for which indexing methods fail because too few X-rays are diffracted into Bragg peaks. The method is demonstrated on a real serial microcrystallography data set whose signals are too weak to be indexed by conventional methods. In spite of the daunting background scatter from the sample-delivery medium, it was still possible to solve the protein structure at 2.1 Å resolution. The ability of the EMC algorithm to analyze weak data frames will help to reduce sample consumption. Furthermore, it will also allow serial microcrystallography to be performed with crystals that are otherwise too small to be feasibly analyzed at storage-ring sources.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

FMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425 , 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493 , 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015 , 1741 , 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 10 12 photons s −1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 10 12 photons s −1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25 , 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ , 5 , 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5 , 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Handheld Biosensor for COVID-19 Screening

We have made significant progress toward the development of an integrated nucleic acid amplification system for Autonomous Medical Devices Incorporated (AMDIs) Optikus handheld diagnostic device. In this effort, we developed a set of loop-mediated isothermal amplification (LAMP) primers for SARS-CoV-2 and then demonstrate amplification directly on a surface acoustic wave (SAW) sensor. We built associated hardware and developed a C-code to control the amplification process. The goal of this project was to develop a nucleic amplification assay that is compatible with SAW sensors to enable both nucleic and serological testing in a single handheld diagnostic device. Toward this goal, AMDI is collaborating Sandia National Laboratories to develop a rapid, portable diagnostic screening device that utilizes Sandias unique surface acoustic wave biosensor (SAW) for COVID-19 detection. Previously, the SANDIA- AMDI SAW sensor has successfully detected multiple high-profile bacteria viruses, including Ebola, HIV, Sin Nombre, and Anthrax. Over the last two years, AMDI and SANDIA have significantly improved the sensitivity and detection capability of the SAW biosensor and have also developed a modular hand-held, portable platform called the Optikus, which uses CD microfluidics and handheld instrumentation to automate all sample preparation, reagent introduction, sample delivery, and measurement for a number of different assay targets. We propose to use this platform for the development of a rapid (%3C30 minutes), point-of-care diagnostic test for detection of COVID-19 from nasal swab samples.

47 OTHER INSTRUMENTATION↗

High-speed fixed-target serial virus crystallography

Here, we report a method for serial X-ray crystallography at X-ray free-electron lasers (XFELs), which allows for full use of the current 120-Hz repetition rate of the Linear Coherent Light Source (LCLS). Using a micropatterned silicon chip in combination with the high-speed Roadrunner goniometer for sample delivery, we were able to determine the crystal structures of the picornavirus bovine enterovirus 2 (BEV2) and the cytoplasmic polyhedrosis virus type 18 polyhedrin, with total data collection times of less than 14 and 10 min, respectively. Our method requires only micrograms of sample and should therefore broaden the applicability of serial femtosecond crystallography to challenging projects for which only limited sample amounts are available. By synchronizing the sample exchange to the XFEL repetition rate, our method allows for most efficient use of the limited beam time available at XFELs and should enable a substantial increase in sample throughput at these facilities.

59 BASIC BIOLOGICAL SCIENCES↗

XANES and EXAFS of dilute solutions of transition metals at XFELs

This work has demonstrated that X-ray absorption spectroscopy (XAS), both Mn XANES and EXAFS, of solutions with millimolar concentrations of metal is possible using the femtosecond X-ray pulses from XFELs. Mn XAS data were collected using two different sample delivery methods, a Rayleigh jet and a drop-on-demand setup, with varying concentrations of Mn. Here, a new method for normalization of XAS spectra based on solvent scattering that is compatible with data collection from a highly variable pulsed source is described. The measured XANES and EXAFS spectra of such dilute solution samples are in good agreement with data collected at synchrotron sources using traditional scanning protocols. The procedures described here will enable XFEL-based XAS on dilute biological samples, especially metalloproteins, with low sample consumption. Details of the experimental setup and data analysis methods used in this XANES and EXAFS study are presented. This method will also benefit XAS performed at high-repetition-rate XFELs such as the European XFEL, LCLS-II and LCLS-II-HE.

Chatterjee, Ruchira (ORCID:000000020865061X)↗

Rayleigh-scattering microscopy for tracking and sizing nanoparticles in focused aerosol beams

Ultra-bright femtosecond X-ray pulses generated by X-ray free-electron lasers (XFELs) can be used to image high-resolution structures without the need for crystallization. For this approach, aerosol injection has been a successful method to deliver 70–2000 nm particles into the XFEL beam efficiently and at low noise. Improving the technique of aerosol sample delivery and extending it to single proteins necessitates quantitative aerosol diagnostics. Here a lab-based technique is introduced for Rayleigh-scattering microscopy allowing us to track and size aerosolized particles down to 40 nm in diameter as they exit the injector. This technique was used to characterize the `Uppsala injector', which is a pioneering and frequently used aerosol sample injector for XFEL single-particle imaging. The particle-beam focus, particle velocities, particle density and injection yield were measured at different operating conditions. It is also shown how high particle densities and good injection yields can be reached for large particles (100–500 nm). It is found that with decreasing particle size, particle densities and injection yields deteriorate, indicating the need for different injection strategies to extend XFEL imaging to smaller targets, such as single proteins. This work demonstrates the power of Rayleigh-scattering microscopy for studying focused aerosol beams quantitatively. It lays the foundation for lab-based injector development and online injection diagnostics for XFEL research. In the future, the technique may also find application in other fields that employ focused aerosol beams, such as mass spectrometry, particle deposition, fuel injection and three-dimensional printing techniques.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

CMS Data transfer operations after the first years of LHC collisions

CMS experiment utilizes distributed computing infrastructure and its performance heavily depends on the fast and smooth distribution of data between different CMS sites. Data must be transferred from the Tier-0 (CERN) to the Tier-1s for processing, storing and archiving, and time and good quality are vital to avoid overflowing CERN storage buffers. At the same time, processed data has to be distributed from Tier-1 sites to all Tier-2 sites for physics analysis while Monte Carlo simulations sent back to Tier-1 sites for further archival. At the core of all transferring machinery is PhEDEx (Physics Experiment Data Export) data transfer system. It is very important to ensure reliable operation of the system, and the operational tasks comprise monitoring and debugging all transfer issues. Based on transfer quality information Site Readiness tool is used to create plans for resources utilization in the future. We review the operational procedures created to enforce reliable data delivery to CMS distributed sites all over the world. Additionally, we need to keep data and meta-data consistent at all sites and both on disk and on tape. In this presentation, we describe the principles and actions taken to keep data consistent on sites storage systems and central CMS Data Replication Database (TMDB/DBS) while ensuring fast and reliable data samples delivery of hundreds of terabytes to the entire CMS physics community.

Kaselis, Rapolas↗

Serial femtosecond and serial synchrotron crystallography can yield data of equivalent quality: A systematic comparison

For the two proteins myoglobin and fluoroacetate dehalogenase, we present a systematic comparison of crystallographic diffraction data collected by serial femtosecond (SFX) and serial synchrotron crystallography (SSX). To maximize comparability, we used the same batch of micron-sized crystals, the same sample delivery device, and the same data analysis software. Overall figures of merit indicate that the data of both radiation sources are of equivalent quality. For both proteins, reasonable data statistics can be obtained with approximately 5000 room-temperature diffraction images irrespective of the radiation source. The direct comparability of SSX and SFX data indicates that the quality of diffraction data obtained from these samples is linked to the properties of the crystals rather than to the radiation source. Therefore, for other systems with similar properties, time-resolved experiments can be conducted at the radiation source that best matches the desired time resolution.

59 BASIC BIOLOGICAL SCIENCES↗