Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “roof”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Impact of post-rainfall evaporation from porous roof tiles on building cooling load in subtropical China

Rainfall occurs frequently in subtropical regions of China, with the subsequent water evaporation from building roofs impacting the thermal performance and the energy consumption of buildings. In this paper, we proposed a novel simulation method using actual meteorological data to evaluate this impact. New features were developed in EnergyPlus to enable the simulation: (1) an evaporation latent heat flux source term was added to the heat balance equation of the external surface and (2) algorithms for the evaporative cooling module (ECM) were developed and implemented into EnergyPlus. The ECM experimental results showed good agreement with the simulated results. The ECM was used to assess the impact of evaporation from porous roof tiles on the cooling load of a one-floor building in subtropical China. The results show that the evaporation process decreased the maximal values of the external and internal roof surface temperatures by up to 6.4 °C and 3.2 °C, respectively, while the lower internal surface temperature decreased the room accumulated cooling load by up to 14.8% during the hot summer period. Lastly, the enhanced EnergyPlus capability can be used to evaluate the evaporative cooling performance of roofs with water-storage mediums, as well as to quantify their impact on building cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling potential air temperature reductions yielded by cool roofs and urban irrigation in the Kansas City Metropolitan Area

In this work, we evaluate two mitigation strategies for urban heat island (UHI) in the Kansas City Metropolitan Area (KCMA). Using the Weather Research and Forecasting (WRF) model, we assess the potential benefits of reflective “cool” roofs and urban irrigation on air temperature in typical summer conditions between 2011 and 2015, and during six of the strongest historical heat waves from 2005 to 2016. Under the typical summer conditions, we simulate 2-m air temperature for 10 summer weeks, finding average daytime (07:00–19:00 local time) temperature reductions of 0.08 and 0.28 °C for cool roofs and urban irrigation, respectively. During the six heat-wave episodes, we find daytime temperature reductions of 0.02 and 0.26 °C for the two scenarios, similar to those under typical summer conditions. Our results suggest that urban irrigation can be more efficient than cool roofs in mitigating UHI in metropolitan regions where the majority of the land cover is comprised of areas with low urban (i.e., non-vegetated) fractions. Finally, we find the alteration of surface conditions due to enhanced roof albedos influences precipitation within the WRF simulation, in particular during the heat waves. Further research would be necessary to determine the robustness of this last finding.

54 ENVIRONMENTAL SCIENCES↗

Systematic Comparison of the Influence of Cool Wall versus Cool Roof Adoption on Urban Climate in the Los Angeles Basin

This study for the first time assesses the influence of employing solar reflective “cool” walls on the urban energy budget and summertime climate of the Los Angeles basin. Here, we systematically compare the effects of cool walls to cool roofs, a heat mitigation strategy that has been widely studied and employed, using a consistent modeling framework (the Weather Research and Forecasting model). Adoption of cool walls leads to increases in urban grid cell albedo that peak in the early morning and late afternoon, when the ratio of solar radiation onto vertical walls versus horizontal surfaces is at a maximum. In Los Angeles County, daily average increase in grid cell reflected solar radiation from increasing wall albedo by 0.80 is 9.1 W m –2 , 43% of that for increasing roof albedo. Cool walls reduce canyon air temperatures in Los Angeles by 0.43 K (daily average), with the peak reduction (0.64 K) occurring at 09:00 LST and a secondary peak (0.53 K) at 18:00 LST. Per 0.10 wall (roof) albedo increase, cool walls (roofs) can reduce summertime daily average canyon air temperature by 0.05 K (0.06 K). Results reported here can be used to inform policies on urban heat island mitigation or climate change adaptation.

54 ENVIRONMENTAL SCIENCES↗

An agent based model for joint placement of PV panels and green roofs

Photovoltaic panels generate electricity directly from sunlight, making them a favored renewable technology. Green roofs are rooftops covered with vegetation, which provide a variety of benefits, namely, reducing stormwater runoff, improving air quality, and biodiversity. Green roofs are capable of improving the efficiency of Photovoltaic panels, as shown by the recent studies. Optimal placement of Photovoltaic panels and green roofs is a challenging problem due to the complications imposed by uncertainties associated with future climate conditions, specifically due to climate change. An agent based model to optimally place Photovoltaic panels and green roofs is developed in this study. We propose a tabu search metaheuristic algorithm to solve the developed model. Then, a real-world case for a mid-sized city in the U.S. is solved as a case study for the model. We further conduct numerical analysis and provide insights.

Li, Xueping↗

Development of a Long-Life-Cycle, Highly Water-Resistant Solar Reflective Retrofit Roof Coating

Highly water-resistant and solar-reflective coatings for low-slope roofs are potentially among the most economical retrofit approaches to thermal management of the building envelope. Therefore, they represent a key building technology research program within the Department of Energy. Research efforts in industry and the Department of Energy are currently under way to increase long-term solar reflectance on a number of fronts. These include new polymer coatings technologies to provide longer-lasting solar reflectivity and improved test methodologies to predict long-term soiling and microbial performance. The focus on long-term improvements in soiling and microbial resistance for maximum reflectance does not address the single most important factor impacting the long-term sustainability of low-slope roof coatings: excellent water resistance. The hydrophobic character of asphaltic roof products makes them uniquely suitable for water resistance, but their low albedo and poor exterior durability are disadvantages. A reflective coating that maintains very high water resistance with increased long-term resistance to soiling and microbial activity would provide additional energy savings and extend roof service life.

36 MATERIALS SCIENCE↗

The Advancement of Cool Roof Standards in China from 2010 to 2015

Since the initiation of the U.S.-China Clean Energy Research Center-Building Energy Efficiency (CERC-BEE) cool roof research collaboration between the Lawrence Berkeley National Laboratory Heat Island Group and Chinese institutions in 2010, new cool surface credits (insulation trade- offs) have been adopted in Chinese building energy efficiency standards, industry standards, and green building standards. JGJ 75-2012: Design Standard for Energy Efficiency of Residential Buildings in Hot Summer and Warm Winter Zone became the first national level standard to provide cool surface credits. GB/T 50378-2014: Assessment Standard for Green Building is the first national level green building standard that offers points for heat island mitigation. JGJ/T 359-2015: Technical Specification for Application of Architectural Reflective Thermal Insulation Coating is the first industry standard that offers cool coating credits for both public and residential buildings in all hot-summer climates (Hot Summer/Cold Winter, Hot Summer/Warm Winter). As of December 2015, eight provinces or municipalities in hot-summer regions have credited cool surfaces credits in their residential and/or public building design standards; five other provinces or municipalities in hot-summer regions recommend, but do not credit, the use of cool surfaces in their building design standards. Cool surfaces could be further advanced in China by including cool roof credits for residential and public building energy efficiency standards in all hot-summer regions; developing a standardized process for natural exposure and aged-property rating of cool roofing products; and adapting the U.S.-developed laboratory aging process for roofing materials to replicate solar reflectance changes induced by natural exposure in China.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility of determining flat roof heat losses using aerial thermography

The utility of aerial thermography for determining rooftop heat losses is investigated. Actual rooftop heat losses were obtained both from in-situ instrumentation of test roofs with known thermal resistances and aerial thermography obtained from overflights at an altitude of 305 m. It is found that the roof heat losses calculated using the remotely determined roof temperature agreed to within 17% of those calculated from ground measurements. However it is noted that an acceptable quantitative determination of roof heat losses using aerial thermography is only feasible when the convective term is accurately known or minimized. In addition, the sensitivity of the heat loss determination to environmental conditions is also evaluated. Finally, the analysis shows that the most reliable determinations can probably be obtained under conditions of total cloud cover with low wind speeds and at low ambient temperatures.

Bowman, R. L.↗

The Successful Transfer of Space Derived Convergent Spray Technology(TM): An Application for Industrial Roof Coatings and Interstate Bridge Repair

Although the levels of volatile organic compound (VOC) emissions from industrial roof coatings and paint operations have been reduced in recent years, the roof coating partnership was an effort to further reduce VOC emission levels and to also demonstrate the use of reclaimed automobile tire rubber as a filler material in roof coating systems. Different materials and coatings were evaluated and tested before the final selection was used to coat the roofs of two small buildings at NASA's MSFC (Marshall Space Flight Center) during fiscal year 1997. The primary objective of the Bridge repair partnership was to strategically leverage public and private sector funds for the purpose of developing a bridge repair process that was cheaper, better, and faster than conventional methods. It was also, imperative that this process be environmentally friendly and capable of performing under extreme conditions for a period of not less than 2 years.

McMillan, Vernotto↗

Experimental comparison of pyranometer, reflectometer, and spectrophotometer methods for the measurement of roofing product albedo

Albedo (solar reflectance) can be measured outdoors with a pyranometer or indoors with a hemispherical reflectometer or a spectrophotometer. The current study evaluates these methods and their applicability to roofing materials by measuring and comparing the ASTM E1918 (pyranometer), non-ASTM E1918A (alternative pyranometer), ASTM C1549 (reflectometer), and E903 (spectrophotometer) albedos of 10 roofing products, including three single-ply membranes, one asphalt shingle, three roofing aggregates, and three high-profile tiles. It uses full-size (4 m × 4 m) assemblies in the E1918 and E1918A trials; corrects the E1918 albedos to remove shadow and background errors; and evaluates C1549 and E903 albedos with two different irradiance spectra, one global horizontal and the other beam normal. E1918A albedos matched E1918 corrected (E1918_cor) albedos to within 0.036. Furthermore, agreement between C1549 air mass 1 global horizontal (C1549_G1) albedo and E1918_cor albedo was within 0.015 for membrane and shingle coupons, and within 0.031 for aggregates, though the uncertainty in the latter agreement was up to 0.043. After minor corrections, C1549_G1 albedos of flat or slightly convex tile chips were 0.032–0.052 higher than the E1918_cor albedos of their corresponding high-profile tile assemblies because high-profile surfaces have concavities. Switching to the beam-normal albedo C1549_1.5E increased the C1549 albedos of the 10 tested products by 0.004–0.054, with the largest increases (C1549_1.5E – C1549_G1) accruing to spectrally selective cool colors. Using C1549_1.5E albedo to characterize a chip of a cool-colored tile compounded the error induced by representing a high-profile surface by a flat or slightly convex specimen.

14 SOLAR ENERGY↗

Observation and Estimation of Evapotranspiration from an Irrigated Green Roof in a Rain-Scarce Environment

While the rain-driven evapotranspiration (ET) process has been well-studied in the humid climate, the mixed irrigation and rain-driven ET process is less understood for green roof implementations in dry regions, where empirical observations and model parameterizations are lacking. This paper presents an effort of monitoring and simulating the ET process for an irrigated green roof in a rain-scarce environment. Annual ET rates for three weighing lysimeter test units with non-vegetated, sedums, and grass covers were 2.01, 2.52, and 2.69 mm d -1 , respectively. Simulations based on the three Penman–Monteith equation-derived models achieved accuracy within the reported range of previous studies. Compared to the humid climate, the overestimation of high ET rates by existing models is expected to cause a larger error in dry environments, where the enhanced ET process caused by repeated irrigations overlapped with hot, dry conditions often occurs during summer. The studied sedum species did not show significantly lower ET rates than native species, and could not effectively take advantage of the deep moisture storage. Therefore, native species, instead of the shallow-rooted species commonly recommended in humid climates, might be a better choice for green roofs in rain-scarce environments.

54 ENVIRONMENTAL SCIENCES↗

Field Evaluation of Four Novel Roof Designs for Energy-Efficient Manufactured Homes

A five-bay roof test structure was built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes. The roof structure in Jamestown, California was designed to examine how differences in roof construction impact space conditioning loads, wood moisture content and attic humidity levels. Conclusions are drawn from the data on the relative energy and moisture performance of various configurations of vented and sealed attics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Evaluation of Four Novel Roof Designs for Energy-Efficient Manufactured Homes

"9A five-bay roof test structure was built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes. The roof structure in Jamestown, California was designed to examine how differences in roof construction impact space conditioning loads, wood moisture content and attic humidity levels. Conclusions are drawn from the data on the relative energy and moisture performance of various configurations of vented and sealed attics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bright is the New Black - Multi-Year Performance of Generic High-Albedo Roofs in an Urban Climate

High-albedo white and cool roofing membranes are recognized as a fundamental strategy that dense urban areas can deploy on a large scale, at low cost, to mitigate the urban heat island effect. We are monitoring three generic white membranes within New York City that represent a cross-section of the dominant white membrane options for U.S. flat roofs: (1) an ethylene propylene diene monomer (EPDM) rubber membrane; (2) a thermoplastic polyolefin (TPO) membrane and; (3) an asphaltic multi-ply built-up membrane coated with white elastomeric acrylic paint. The paint product is being used by New York City s government for the first major urban albedo enhancement program in its history. We report on the temperature and related albedo performance of these three membranes at three different sites over a multi-year period. The results indicate that the professionally installed white membranes are maintaining their temperature control effectively and are meeting the Energy Star Cool Roofing performance standards requiring a three-year aged albedo above 0.50. The EPDM membrane however shows evidence of low emissivity. The painted asphaltic surface shows high emissivity but lost about half of its initial albedo within two years after installation. Given that the acrylic approach is an important "do-it-yourself," low-cost, retrofit technique, and, as such, offers the most rapid technique for increasing urban albedo, further product performance research is recommended to identify conditions that optimize its long-term albedo control. Even so, its current multi-year performance still represents a significant albedo enhancement for urban heat island mitigation.

Gaffin, S. R.↗

High efficiency translucent solar module integrated with greenhouse roof structures

A translucent solar module assembly for integration with a greenhouse having a frame with a plurality of roof supports includes a pair of brackets attachable to each of the plurality of roof supports, a bi-facial solar panel attachable to the pair of brackets, and a pair of reflector rails attachable to each of the plurality of roof supports. A dichroic reflector is attachable to the pair of reflector rails.

Pan, Wei↗

An agent-based approach to study the diffusion rate and the effect of policies on joint placement of photovoltaic panels and green roof under climate change uncertainty

As two of the highest trending green technologies, photovoltaic panels and green roofs are proven to be effective practices for energy generation and energy saving. The achievable impact from the widespread installation of such technologies is, however, not clearly established. This is mainly because the degree of this impact highly depends on the inherently uncertain environmental and climate factors, as well as the unknown adoption rates of these technologies, which in turn depend on different characteristics of decision makers and interactions among them. To that end, this study aims to investigate the diffusion rate of these green technologies under uncertainties caused by climate change, characteristics of adopters, and their interactions. An integrated framework is developed to capture the interplay between financial and attitudinal aspects, as well as the uncertainties due to both the stochastic nature of system parameters and the interactions among agents involving human beings. Specifically, this framework consists of a integer programming model to optimize the green roof and/or photovoltaic panel installation settings for a given building under climate change uncertainty, and an agent-based model to factor in the role of human behavior and interactions. A case study for the city of Knoxville, TN, is presented to evaluate the effects of different policies on the diffusion rate of the green technologies of interest. The results show that the affordability of green technologies and public awareness are the key drivers of the adoption of these technologies, which highlight the important role of the decision makers in impacting the diffusion rate.

14 SOLAR ENERGY↗

Calibration of laboratory aging practice to replicate changes to roof albedo in a Chinese city

Highly reflective roofs can save building air conditioning energy, mitigate the urban heat island, and offset CO 2 emissions. A laboratory aging methodology was developed to simulate change in the solar reflectances of field-applied roof coatings induced by one year of natural exposure in Guangzhou (China). The approach compared the changes in solar reflectance spectra observed in the naturally exposed materials with those obtained following a three-stage laboratory procedure: conditioning, soiling, and weathering. The method was systematically modified over five trials by adjusting the key variables in laboratory aging: composition of the soiling mixture, deposition mass, and conditions of soiling application. Tests were performed using a small number of specimens. Simulating exposure in Guangzhou required a loading of soiling agents greater than that used to simulate US cites. In the final trial, the reduction in solar reflectance was reproduced to within an average of 0.02 for three of the six products, and to within an average of 0.06 for the remaining three products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also tested the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Relationship of roof falls in underground coal mines to fractures mapped on ERTS-1 imagery

ERTS imagery is of unique value for mapping of certain fractures that are not identifiable on aircraft imagery. Because color infrared and ERTS imagery complement each other both sources of data were used to map fractures in western Indiana and eastern Illinois. In the Kings Station Mine, Gibson County, Indiana, most roof falls reported had occurred in areas where mapped fractures were closely spaced and intersecting. Using this information as a basis for extrapolation, roof fall hazard maps were prepared for other mine sites. Various coal resources programs related to energy and environment also were conducted.

Wier, C. E.↗