Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resonator temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The broadening of the calcium resonance line in a high-temperature helium atmosphere

The paper describes experimental measurements of the shape of the Ca I resonance line at 4227 A in a high-temperature helium atmosphere. A ballistic piston compressor was used to produce hot helium in the temperature range from 3000 to 7000 K and the number-density range from 2 to 4 by 10 to the 20th power per cu cm, which conditions approximate those postulated for the atmospheres of certain cool white-dwarf stars. The Boltzmann temperature of the calcium atoms was measured by the brightness-emissivity method, the absorption line shape was measured with a twelve-channel polychromator, and the helium kinetic temperature was calculated from the equation of an ideal gas. The observed deviation from thermodynamic equilibrium is illustrated. The value of the ratio of the damping constant to the helium number density at 5000 K is found to be 45 (+ or - 4) by 10 to the -22nd power A cu cm, or 4.7 (+ or - 0.4) by 10 to the -9th power rad/s cu cm. It is noted that no existing line-broadening calculation for the calcium-helium system is consistent with the present results. Recent studies of the 4227-A line in spectra of the sun and the white dwarf van Maanen 2 are discussed.

Driver, R. D.↗

The effect of an isotopic non-equilibrium plasma on electron temperature measurements

Electron temperatures determined by electrostatic probe, diffuse resonance, and radar backscatter techniques in an isotropic two temperature plasma are presented. Plasma models corresponding to the addition of a minor component of energetic electrons, and models corresponding to a process that cools a fraction of the ionospheric electrons are considered. The diffuse resonance temperature is found to lie between the probe and radar backscatter temperatures. The isotropic models corresponding to the addition of energetic electrons cannot support the reported discrepancies between radio wave and probe electron temperature measurements. Temperature differences similar to the observed differences can be produced by models with a fraction of the electrons at a temperature cooler than that of the main component of electrons.

Benson, R. F.↗

Accurate Measurements of the Dielectric Constant of Seawater at L Band

This paper describes measurements of the dielectric constant of seawater at a frequency of 1.413 GHz, the center of the protected band (i.e., passive use only) used in the measurement of sea surface salinity from space. The objective of the measurements is to accurately determine the complex dielectric constant of seawater as a function of salinity and temperature. A resonant cylindrical microwave cavity in transmission mode has been employed to make the measurements. The measurements are made using standard seawater at salinities of 30, 33, 35, and 38 practical salinity units over a range of temperatures from 0 degree C to 35 degree C in 5 degree C intervals. Repeated measurements have been made at each temperature and salinity. Mean values and standard deviations are then computed. The total error budget indicates that the real and imaginary parts of the dielectric constant have a combined standard uncertainty of about 0.3 over the range of salinities and temperatures considered. The measurements are compared with the dielectric constants obtained from the model functions of Klein and Swift and those of Meissner and Wentz. The biggest differences occur at low and high temperatures.

Measurements↗

Frequency Stability of 1X10(sup -13) in a compensated Saphirre Oscillator Operating Above 77K

We report on tests of a compensated saphirre oscillator (CS) which shows frequency-stable operation at temperatures above 77k.The frequency stability for this oscillator shows an apparent flicker floor of 7.5X10(sup -14) for measuring times between 3 and 10 seconds, and stability is better than 2X10(sup -13) for all measuring times between 10 and 100 seconds... Frequency sensitivities os the microwave sapphire resonator to temperature and temperature rate have been characterized, and a careful analysis of several aspects of the ac frequency-lock.

compensated saphirre oscillator frequency stabilit↗

Photometer for detection of sodium day airglow.

Description of a photometer for daytime ground-based measurements of sodium airglow emission. The photometer described can be characterized by the following principal features: (1) a narrow (4.5-A) interference filter for initial discrimination; (2) cooled photomultiplier detector to reduce noise from dark current fluctuations and chopping to eliminate the average dark current; (3) a sodium vapor resonance cell to provide an effective bandpass comparable to the Doppler line width; (4) separate detection of all light transmitted by the interference filter to evaluate the Rayleigh and Mie components within the Doppler width of the resonance cell; and (5) temperature quenching of the resonance cell to evaluate and account for instrumental imperfections.

Mcmahon, D. J.↗

Coordinated analysis of airborne spectrophotometric measurements from the mid-day auroras

Measurements made in the midday auroras are analyzed and compared to measurements from the nighttime auroras. The auroral emission features in the UV spectrum, the N2(+)ING, the N22PG, and N2VK bands, are discussed. Spectral profiles of different bands are presented, and intensity distributions are obtained. Three mechanisms are suggested which can account for the marked differences between the intensity distributions of the N2(+)ING bands of the high altitude midday auroras and the low altitude nighttime auroras: (1) differences in vibrational, rotational, and transitional temperatures; (2) resonant scattering of solar radiation; and (3) excitation of slow ions.

Sivjee, G. G.↗

Discriminator Stabilized Superconductor/Ferroelectric Thin Film Local Oscillator

A tunable local oscillator with a tunable circuit that includes a resonator and a transistor as an active element for oscillation. Tuning of the circuit is achieved with an externally applied dc bias across coupled lines on the resonator. Preferably the resonator is a high temperature superconductor microstrip ring resonator with integral coupled lines formed over a thin film ferroelectric material. A directional coupler samples the output of the oscillator which is fed into a diplexer for determining whether the oscillator is performing at a desired frequency. The high-pass and lowpass outputs of the diplexer are connected to diodes respectively for inputting the sampled signals into a differential operational amplifier. The amplifier compares the sampled signals and emits an output signal if there is a difference between the resonant and crossover frequencies. Based on the sampled signal, a bias supplied to the ring resonator is either increased or decreased for raising or lowering the resonant frequency by decreasing or increasing, respectively, the dielectric constant of the ferroelectric.

Romanofsky, Robert R.↗

Effect of an isotropic nonequilibrium plasma on electron temperature measurements.

The electron temperatures that would be determined (using the conventional single-temperature analysis) by the electrostatic probe, the diffuse resonance, and the radar backscatter techniques in an isotropic two-temperature plasma are presented. Plasma models corresponding to the addition of a minor component of energetic electrons and models corresponding to a process that cools a fraction of the ionospheric electrons are considered. The diffuse resonance temperature is found to lie between the probe and radar backscatter temperatures. The isotropic models corresponding to the addition of energetic electrons cannot support the reported discrepancies between radio wave and probe electron temperature measurements. Temperature differences similar to the observed differences can be produced by models with a fraction of the electrons at a temperature cooler than that of the main component of electrons. These models, however, are difficult to explain in terms of present understanding of the ionospheric plasma.

Benson, R. F.↗

Temperature-dependent transmission and self-indication measurements upon depleted U in the unresolved region

Neutron transmission and self-indication ratio measurements have been carried out at the RPI LINAC on depleted U up to 100 KeV in order to investigate the temperature dependence of resonance self-shielding. These measurements were performed at three sample temperatures (77 deg k, 295 deg k, and 973 deg k) and with sample thicknesses ranging from 0.0076 to 0.0621 atom/barn. Both stochastic sampling and analytical methods have been used to interpret these data. Average resonance parameters have been obtained and temperature dependence as well as sample thickness dependence of the data have been extensively studied.

Byoun, T. Y.↗

Microwave resonance lamp absorption technique for measuring temperature and OH number density in combustion environments

A simple technique for simultaneous determination of temperature and OH number density is described, along with characteristic results obtained from measurements using a premixed, hydrogen air flat flame burner. The instrumentation is based upon absorption of resonant radiation from a flowing microwave discharge lamp, and is rugged, relatively inexpensive, and very simple to operate.

Lempert, Walter R.↗

Microwave characterization of high-temperature superconducting thin films using stripline resonators

A method was derived for the extraction of the surface resistivity (Rs) of high-Tc superconducting (HTS) thin films at microwave frequencies, using a stripline resonator circuit. Surface resistivity values were calculated by measuring the difference in Q-values of a stripline resonator configuration when an HTS thin film was substituted for one of the metallic ground planes. Cryogenic tests were completed for several stripline resonator structures, yielding accurate predictions of the HTS thin-film performance at frequencies between 3 and 26 GHz (in harmonics of approximately 3 GHz). These results were then used to illustrate the dependence of HTS surface resistivity on frequency and temperature in the microwave frequency band.

Macdonald, Alan D.↗

Differential temperature sensor system and method

A differential temperature sensor system and method of determining a temperature shift of an optical resonator and its surroundings are provided. The differential temperature sensor system includes a light generating device capable of generating a beam having a carrier frequency, a modulator capable of modulating the beam with a sideband frequency, and an optical resonator capable of supporting an ordinary mode and an extraordinary mode. The system includes an ordinary mode-lock setup capable of locking the carrier frequency of the beam to the ordinary mode of the optical resonator and an extraordinary mode-lock setup capable of locking the sideband frequency of the beam to the extraordinary mode of the optical resonator by providing a specific radio frequency to the modulator substantially corresponding to a frequency shift between the ordinary mode and the extraordinary mode of the optical resonator resulting from a temperature change of the optical resonator. A processor precisely calculates the differential temperature based upon the frequency shift between the ordinary mode and extraordinary mode of the optical resonator.

Savchenkov, Anatoliy A.↗

Acoustic Levitator Maintains Resonance

Transducer loading characteristics allow resonance tracked at high temperature. Acoustic-levitation chamber length automatically adjusted to maintain resonance at constant acoustic frequency as temperature changes. Developed for containerless processing of materials at high temperatures, system does not rely on microphones as resonance sensors, since microphones are difficult to fabricate for use at temperatures above 500 degrees C. Instead, system uses acoustic transducer itself as sensor.

Barmatz, M. B.↗

High Q Miniature Sapphire Acoustic Resonator

We have demonstrated high Q measurements in a room temperature Miniature Sapphire Acoustic Resonator (MSAR). Initial measurements of bulk acoustic modes in room temperature sapphire at 39 MHz have demonstrated a Q of 8.8 x 10(exp 6). The long term goal of this work is to integrate such a high Q resonator with small, low noise quartz oscillator electronics, providing a fractional frequency stability better than 1 x 10(exp -14) @ 1s.

oscillator↗