Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “realism”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The evolution of process-based hydrologic models: historical challenges and the collective quest for physical realism

The diversity in hydrologic models has historically led to great controversy on the correct approach to process-based hydrologic modeling, with debates centered on the adequacy of process parameterizations, data limitations and uncertainty, and computational constraints on model analysis. Here, we revisit key modeling challenges on requirements to (1) define suitable model equations, (2) define adequate model parameters, and (3) cope with limitations in computing power. We outline the historical modeling challenges, provide examples of modeling advances that address these challenges, and define outstanding research needs. We also illustrate how modeling advances have been made by groups using models of different type and complexity, and we argue for the need to more effectively use our diversity of modeling approaches in order to advance our collective quest for physically realistic hydrologic models.

54 ENVIRONMENTAL SCIENCES↗

The Real Inputs Behind TCO: Duty Cycle Realism and Opportunity Costs using T3CO

NLR's Transportation Technology Total Cost of Ownership (T3CO) model provides realistic and robust analysis, capturing the impact of real world duty cycles and their variability in operating and opportunity costs. Case studies show that these contributions to costs can be significant and can alter conclusions about technology cost effectiveness.

33 ADVANCED PROPULSION SYSTEMS↗

Comment on 'Realism and quantum flux tunneling'

A reply is presented to Ballentine's (1987) critique of the Legett and Garg (1985) experiment to discriminate between the experimental predictions of quantum mechanics (QM) and those of a class of macrorealistic theories. Legett and Garg uphold their earlier conclusions on the basis of the fact that the present critique refers to an experiment which was not in fact proposed. It is stressed that the original work involved an analysis according to macrorealism, while the calculations of Ballentine only demonstrate the internal consistency of the formalism of QM when applied to three consecutive actually performed experiments.

Leggett, A. J.↗

Improving Realism in Reduced Gravity Simulators

Since man was first determined to walk on the moon, simulating the lunar environment became a priority. Providing an accurate reduced gravity environment is crucial for astronaut training and hardware testing. This presentation will follow the development of reduced gravity simulators to a final comparison of environments between the currently used systems. During the Apollo program era, multiple systems were built and tested, with several NASA centers having their own unique device. These systems ranged from marionette-like suspension devices where the subject laid on his side, to pneumatically driven offloading harnesses, to parabolic flights. However, only token comparisons, if any, were made between systems. Parabolic flight allows the entire body to fall at the same rate, giving an excellent simulation of reduced gravity as far as the biomechanics and physical perceptions are concerned. While the effects are accurate, there is limited workspace, limited time, and high cost associated with these tests. With all mechanical offload systems only the parts of the body that are actively offloaded feel any reduced gravity effects. The rest of the body still feels the full effect of gravity. The Partial Gravity System (Pogo) is the current ground-based offload system used to training and testing at the NASA Johnson Space Center. The Pogo is a pneumatic type system that allows for offloaded motion in the z-axis and free movement in the x-axis, but has limited motion in the y-axis. The pneumatic system itself is limited by cylinder stroke length and response time. The Active Response Gravity Offload System (ARGOS) is a next generation groundbased offload system, currently in development, that is based on modern robotic manufacturing lines. This system is projected to provide more z-axis travel and full freedom in both the x and y-axes. Current characterization tests are underway to determine how the ground-based offloading systems perform, how they compare to parabolic flights, and which of the systems is preferable for specific uses. These tests were conducted with six degree of freedom robots and manual inputs. Initial results show a definitive difference in abilities of the two offload systems.

Cowley, Matthew↗

Immersive Simulations and Engineering Environment (iSEE): Increasing the Realism of Simulations

The Immersive Simulations and Engineering Environment (iSEE) lab at Kennedy Space Center has been operating with its current team since 2017. The lab provides National Aeronautics and Space Administration (NASA) with simulations that show the stress and strain that a strenuous task can cause on a body. Previously the lab was using software that was efficient in ergonomic analysis of a human body, but limited in creating a realistic simulation. To produce a more realistic simulation, the iSEE invested in new software that could potentially create an environment that could show the viewer a simulation that was closer to reality.

Hodge, Brianna↗

Covariance Realism Is Not Enough

A great deal of effort has been put into improving the practice of space situational awareness such that covariance data associated with predicted close approaches is more “realistic.” However, “realistic” usually has meant “larger” and this presents a problem. In many cases, there exist multiple sources for predictive ephemerides, which may be fused to produce predictive states with smaller associated covariances. Ancillary to the fusion computation is the capability to assess consistency of the estimates. If actionable covariance information becomes available, interval estimates for the miss distance provide a more informative alternative to collision probability for risk assessment.

Carpenter, J. Russell↗

Establishing an IEZ at the K-25 Site With Realism [Slides]

The requirement from ANSI/ANS-8.3 states: (1) a criticality alarm system meeting the requirements of this standard shall be installed in areas where personnel would be subject to an excessive radiation dose; and (2) excessive dose = any dose to personnel corresponding to an absorbed dose from neutrons and gamma rays equal to or greater than 0.12 Gy (12 rad) in free air. The requirement was misconstrued to imply that the Immediate Evaluation Zone (IEZ) had to cover out to 12 Rad of dose. This misinterpretation prompted the following official clarification: The standard does not attempt to define the area that is to be evacuated, which is considered a management responsibility and outside the scope of this Standard. What we wanted was an IEZ that: (1) depended on the facility characteristics and hazards; (2) departed from the one 'Size' fits all mentality; (3) balanced the risk of a criticality with the risk of evacuating; and (4) was consistent with the emergency planning process. What they have is a facility that is a mile long; a facility that was falling down around them; a facility where workers are routinely in fall protection; and a facility where high noise is the normal condition. They ended up matching ANS-8.23 with their EPHA and DSA and eliminated 12 Rad as the criterion; integrated Emergency Planning into the process; established evacuation zones using DSA consequence levels; and introduced time dependence into the evacuation process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of Field of View and Visual Complexity on Virtual Reality Training Effectiveness for a Visual Scanning Task

Virtual reality training systems are commonly used in a variety of domains, and it is important to understand how the realism of a training simulation influences training effectiveness. The paper presents a framework for evaluating the effects of virtual reality fidelity based on an analysis of a simulation’s display, interaction, and scenario components. Following this framework, we conducted a controlled experiment to test the effects of fidelity on training effectiveness for a visual scanning task. The experiment varied the levels of field of view and visual realism during a training phase and then evaluated scanning performance with the simulator’s highest level of fidelity. To assess scanning performance, we measured target detection and adherence to a prescribed strategy. The results show that both field of view and visual realism significantly affected target detection during training; higher field of view led to better performance and higher visual realism worsened performance. Additionally, the level of visual realism during training significantly affected learning of the prescribed visual scanning strategy, providing evidence that high visual realism was important for learning the technique. The results also demonstrate that task performance during training was not always a sufficient measure of mastery of an instructed technique. That is, if learning a prescribed strategy or skill is the goal of a training exercise, performance in a simulation may not be an appropriate indicator of effectiveness outside of training—evaluation in a more realistic setting may be necessary.

97 MATHEMATICS AND COMPUTING↗

TU-A-17A-02: In Memoriam of Ben Galkin: Virtual Tools for Validation of X-Ray Breast Imaging Systems

This symposium will explore simulation methods for the preclinical evaluation of novel 3D and 4D x-ray breast imaging systems – the subject of AAPM taskgroup TG234. Given the complex design of modern imaging systems, simulations offer significant advantages over long and costly clinical studies in terms of reproducibility, reduced radiation exposures, a known reference standard, and the capability for studying patient and disease subpopulations through appropriate choice of simulation parameters. Our focus will be on testing the realism of software anthropomorphic phantoms and virtual clinical trials tools developed for the optimization and validation of breast imaging systems. The symposium will review the stateof- the-science, as well as the advantages and limitations of various approaches to testing realism of phantoms and simulated breast images. Approaches based upon the visual assessment of synthetic breast images by expert observers will be contrasted with approaches based upon comparing statistical properties between synthetic and clinical images. The role of observer models in the assessment of realism will be considered. Finally, an industry perspective will be presented, summarizing the role and importance of virtual tools and simulation methods in product development. The challenges and conditions that must be satisfied in order for computational modeling and simulation to play a significantly increased role in the design and evaluation of novel breast imaging systems will be addressed. Learning Objectives: Review the state-of-the science in testing realism of software anthropomorphic phantoms and virtual clinical trials tools; Compare approaches based upon the visual assessment by expert observers vs. the analysis of statistical properties of synthetic images; Discuss the role of observer models in the assessment of realism; Summarize the industry perspective to virtual methods for breast imaging.

60 APPLIED LIFE SCIENCES↗

Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data

Purpose: The authors previously reported on a three-dimensional computer-generated breast phantom, based on empirical human image data, including a realistic finite-element based compression model that was capable of simulating multimodality imaging data. The computerized breast phantoms are a hybrid of two phantom generation techniques, combining empirical breast CT (bCT) data with flexible computer graphics techniques. However, to date, these phantoms have been based on single human subjects. In this paper, the authors report on a new method to generate multiple phantoms, simulating additional subjects from the limited set of original dedicated breast CT data. The authors developed an image morphing technique to construct new phantoms by gradually transitioning between two human subject datasets, with the potential to generate hundreds of additional pseudoindependent phantoms from the limited bCT cases. The authors conducted a preliminary subjective assessment with a limited number of observers (n= 4) to illustrate how realistic the simulated images generated with the pseudoindependent phantoms appeared. Methods: Several mesh-based geometric transformations were developed to generate distorted breast datasets from the original human subject data. Segmented bCT data from two different human subjects were used as the 'base' and 'target' for morphing. Several combinations of transformations were applied to morph between the 'base' and 'target' datasets such as changing the breast shape, rotating the glandular data, and changing the distribution of the glandular tissue. Following the morphing, regions of skin and fat were assigned to the morphed dataset in order to appropriately assign mechanical properties during the compression simulation. The resulting morphed breast was compressed using a finite element algorithm and simulated mammograms were generated using techniques described previously. Sixty-two simulated mammograms, generated from morphing three human subject datasets, were used in a preliminary observer evaluation where four board certified breast radiologists with varying amounts of experience ranked the level of realism (from 1 ='fake' to 10 ='real') of the simulated images. Results: The morphing technique was able to successfully generate new and unique morphed datasets from the original human subject data. The radiologists evaluated the realism of simulated mammograms generated from the morphed and unmorphed human subject datasets and scored the realism with an average ranking of 5.87 {+-} 1.99, confirming that overall the phantom image datasets appeared more 'real' than 'fake.' Moreover, there was not a significant difference (p > 0.1) between the realism of the unmorphed datasets (6.0 {+-} 1.95) compared to the morphed datasets (5.86 {+-} 1.99). Three of the four observers had overall average rankings of 6.89 {+-} 0.89, 6.9 {+-} 1.24, 6.76 {+-} 1.22, whereas the fourth observer ranked them noticeably lower at 2.94 {+-} 0.7. Conclusions: This work presents a technique that can be used to generate a suite of realistic computerized breast phantoms from a limited number of human subjects. This suite of flexible breast phantoms can be used for multimodality imaging research to provide a known truth while concurrently producing realistic simulated imaging data.

60 APPLIED LIFE SCIENCES↗

The simulation of 3D mass models in 2D digital mammography and breast tomosynthesis

Purpose: This work proposes a new method of building 3D breast mass models with different morphological shapes and describes the validation of the realism of their appearance after simulation into 2D digital mammograms and breast tomosynthesis images. Methods: Twenty-five contrast enhanced MRI breast lesions were collected and each mass was manually segmented in the three orthogonal views: sagittal, coronal, and transversal. The segmented models were combined, resampled to have isotropic voxel sizes, triangularly meshed, and scaled to different sizes. These masses were referred to as nonspiculated masses and were then used as nuclei onto which spicules were grown with an iterative branching algorithm forming a total of 30 spiculated masses. These 55 mass models were projected into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. The realism of the appearance of these mass models was assessed by five radiologists via receiver operating characteristic (ROC) analysis when compared to 54 real masses. All lesions were also given a breast imaging reporting and data system (BIRADS) score. The data sets of 2D mammography and tomosynthesis were read separately. The Kendall's coefficient of concordance was used for the interrater observer agreement assessment for the BIRADS scores per modality. Further paired analysis, using the Wilcoxon signed rank test, of the BIRADS assessment between 2D and tomosynthesis was separately performed for the real masses and for the simulated masses. Results: The area under the ROC curves, averaged over all observers, was 0.54 (95% confidence interval [0.50, 0.66]) for the 2D study, and 0.67 (95% confidence interval [0.55, 0.79]) for the tomosynthesis study. According to the BIRADS scores, the nonspiculated and the spiculated masses varied in their degrees of malignancy from normal (BIRADS 1) to highly suggestive for malignancy (BIRADS 5) indicating the required variety of shapes and margins of these models. The assessment of the BIRADS scores for all observers indicated good agreement based on Kendall's coefficient for both the 2D and the tomosynthesis evaluations. The paired analysis of the BIRADS scores between 2D and tomosynthesis for each observer revealed consistent behavior for the real and simulated masses. Conclusions: A database of 3D mass models, with variety of shapes and margins, was validated for the realism of their appearance for 2D digital mammography and for breast tomosynthesis. This database is suitable for use in future observer performance studies whether in virtual clinical trials or in patient images with simulated lesions.

60 APPLIED LIFE SCIENCES↗

Lesion insertion in the projection domain: Methods and initial results

Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically acquired for the ACR phantom in terms of Hounsfield unit and high-contrast resolution. For the validation of the lesion realism, lesions of various types were successfully inserted, including well circumscribed and invasive lesions, homogeneous and heterogeneous lesions, high-contrast and low-contrast lesions, isolated and vessel-attached lesions, and small and large lesions. The two experienced radiologists who reviewed the original and inserted lesions could not identify the lesions that were inserted. The same lesion, when inserted into the projection domain and reconstructed with different parameters, demonstrated a parameter-dependent appearance. Conclusions: A framework has been developed for projection-domain insertion of lesions into commercial CT images, which can be potentially expanded to all geometries of CT scanners. Compared to conventional image-domain methods, the authors’ method reflected the impact of scan and reconstruction parameters on lesion appearance. Compared to prior projection-domain methods, the authors’ method has the potential to achieve higher anatomical complexity by employing clinical patient projections and real patient lesions.

60 APPLIED LIFE SCIENCES↗

Three CA-Related Covariance Issues and Their Solutions

This presentation addresses three issues that arise in the use of DoD-produced satellite state estimate covariances in the conjunction assessment process: the realism of the provided covariances, how to address correlated error between two satellites' covariance matrices, and how to proceed when a furnished covariance is non-positive-definite. To address the first, DoD has implemented a set of two "consider parameters" with which to alter/expand the covariance to account for atmospheric density forecast error and satellite frontal area uncertainty, the two largest sources of unmodeled position prediction error for LEO orbits; these values are governed by a satellite's orbital parameters and ballistic coefficient histories, as well as the current and predicted space weather situation. This approach substantially improves the realism of the covariance by accounting for expected prediction errors that are not part of the fit process that generates the covariance. The second issue of covariance correlation is a complicated one, but the main shared error source—global atmospheric density error that is common to both satellites can be characterized and, through sensitivity vectors, quantified at the conjunction's time of closest approach and removed from the joint covariance, which is used in the CA probability of collision (Pc) calculation. Finally, while according to the orbit determination theory a non-positive-definite (NPD) covariance is not possible, numerical truncation and covariance interpolation can conspire to produce NPD results, which render the covariance unusable for certain CA risk assessment calculations, such as Monte Carlo Pc determination. Three similar techniques are profiled and the simplest of them recommended as a reasonable remediation technique when NPD covariances are encountered by CA practitioners.

Dynamic Consider Parameter↗

Transferability in the future climate of a statistical downscaling method for precipitation in France

A statistical downscaling approach for precipitation in France based on the analog method and its evaluation for different combinations of predictors is described, with a focus on the transferability of the method to the future climate. First, the realism of downscaled present-day precipitation climatology and inter-annual variability for different combinations of predictors from four reanalyses is assessed. Satisfactory results are obtained but elaborated predictors do not lead to major and consistent across reanalyses improvements. The downscaling method is then evaluated on its capacity to capture precipitation trends in the last decades. As uncertainties in downscaled trends due to the choice of the reanalysis are large andobserved trends are weak, this analysis does not lead to strong conclusions on the applicability of the method to a changing climate. The temporal transferability is then assessed thanks to a perfect-model framework. The statistical downscaling relationship is built using present-day predictors and precipitation simulated by twelve regional climate models. The entire projections are then downscaled, and future downscaled and simulated precipitation changes are compared. A good temporal transferability is obtained only with a specific combination of predictors. Finally, the regional climate models are downscaled thanks to the relationship built with reanalyses and observations, for the best combination of predictors. Results are similar to the changes simulated by the models, which reinforces our confidence in the realism of the models and of the downscaling method. Uncertainties in precipitation change due to reanalyses are found to be limited compared to those due to regional simulations.

54 ENVIRONMENTAL SCIENCES↗

Incorporating microbial dormancy dynamics into soil decomposition models to improve quantification of soil carbon dynamics of northern temperate forests

Abstract Soil carbon dynamics of terrestrial ecosystems play a significant role in the global carbon cycle. Microbial‐based decomposition models have seen much growth recently for quantifying this role, yet dormancy as a common strategy used by microorganisms has not usually been represented and tested in these models against field observations. Here we developed an explicit microbial‐enzyme decomposition model and examined model performance with and without representation of microbial dormancy at six temperate forest sites of different forest types. We then extrapolated the model to global temperate forest ecosystems to investigate biogeochemical controls on soil heterotrophic respiration and microbial dormancy dynamics at different temporal‐spatial scales. The dormancy model consistently produced better match with field‐observed heterotrophic soil CO 2 efflux ( R H ) than the no dormancy model. Our regional modeling results further indicated that models with dormancy were able to produce more realistic magnitude of microbial biomass (<2% of soil organic carbon) and soil R H (7.5 ± 2.4 Pg C yr −1 ). Spatial correlation analysis showed that soil organic carbon content was the dominating factor (correlation coefficient = 0.4–0.6) in the simulated spatial pattern of soil R H with both models. In contrast to strong temporal and local controls of soil temperature and moisture on microbial dormancy, our modeling results showed that soil carbon‐to‐nitrogen ratio (C:N) was a major regulating factor at regional scales (correlation coefficient = −0.43 to −0.58), indicating scale‐dependent biogeochemical controls on microbial dynamics. Our findings suggest that incorporating microbial dormancy could improve the realism of microbial‐based decomposition models and enhance the integration of soil experiments and mechanistically based modeling.

He, Yujie↗

On the role of joint probability distributions of incompatible observables in Bell and Kochen–Specker Theorems

Highlights: •Bell and Kochen–Specker theorems rule out local or noncontextual realist models. •Still, they assume a joint probability distribution for incompatible observables. •Those joint probability distributions do not exist in quantum mechanics. •Realist models without joint distributions for incompatible observables are given. •A reformulation of Bell and Kochen–Specker arguments is provided to rule them out. -- Abstract: We analyze the validity of Bell and Kochen–Specker theorems under local (or noncontextual) realism but avoiding an assumption of the existence of a joint probability distribution for incompatible observables. We formulate a realist model which complies with this requirement. This is obtained by employing divergent sequences that nevertheless have marginals which are convergent. We find that under standard reasonable assumptions this possibility does not lead to a loophole of those theorems, by deriving a short of CHSH inequality valid for any finite size ensemble. Moreover, we analyze a Hardy’s paradox setting where noncontextual realism imposes the existence of joint probabilities for incompatible observables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗