Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reactive power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Fairness-Aware Distributed Energy Coordination for Voltage Regulation in Power Distribution Systems

The accelerating deployment of solar photovoltaics into low-voltage distribution networks can cause reverse power flow and overvoltage problems. However, if coordinated properly, the real and reactive power flexibility of these resources enables distribution operators to manage their networks more efficiently. Existing literature is rich in droop-based control (Volt-Watt and Volt-VAr) and optimization-based distributed energy coordination for four-quadrant control of photovoltaics to prevent overvoltage issues. While optimal coordination can effectively mitigate overvoltage, it tends to treat resources at sensitive parts of the grid unfairly. Here, to address this concern, we propose a distributed optimal power flow formulation that incorporates fairness in curtailing photovoltaic generation and utilizes the reactive power capability of smart inverters. The proposed distributed formulation allows for scalable resource aggregation that can be leveraged to achieve fairness within a certain segment of the grid and/or fairness across the entire network. Fair curtailment of photovoltaic systems is demonstrated with aggregation at each of two layers in a distribution network: 1) area-level fairness and 2) feeder-level fairness. To explore the trade-off between fairness and optimal utilization, the fairness-aware control actions are compared against the performance of a centralized controller that aims to maximize the aggregate PV generation without incorporating fairness. Simulation results show that introducing area-level fairness increased curtailment by 0.0101 percentage points and feeder-level fairness increased curtailment by 0.0458 percentage points compared to a fairness-agnostic control.

Poudel, Shiva↗

Hierarchical Flexibility Offering Strategy for Integrated Hybrid Resources in Real-time Energy Markets

This paper proposes a hierarchical model for determining the energy flexibility offering strategy of integrated hybrid resources (IHRs) in power distribution systems to participate in real-time energy markets. The proposed model utilizes the scalability, fast response time, and uncertainty observation of deep reinforcement learning (DRL) to overcome the scalability issue of operating numerous flexible resources and deliverability of energy flexibility to the real-time markets in the presence of the network constraints. To that end, the power distribution system is divided into multiple IHRs, where different types of flexible loads, energy storage systems, and solar plants with controllable inverters are operated through local IHR controllers, trained by deep deterministic policy gradient (DDPG) algorithm. Active power request and reactive power capacity of IHRs are then transmitted to a central flexibility controller, where a quadratic optimization model ensures the deliverability of the energy flexibility to the real-time energy market by satisfying the distribution network constraints. The proposed model is implemented on the 123-bus test power distribution system, demonstrating the capability of DRL-based hierarchical model for scalable operation of IHRs in order to offer deliverable energy flexibility to the real-time energy market.

Majidi, Majid↗

Reconfiguration of power grids during abnormal conditions using reclosers and distributed energy resources

Apparatus and methods are disclosed for restoring operation of a power grid comprising a plurality of reclosers and distributed energy resources (DERs) responsive to abnormal conditions by determining and implementing a reconfiguration for the power grid. The reconfiguration can specify respective new statuses for one or more of the reclosers and/or respective quantities of reactive power to be supplied by one or more of the DERs. The reconfiguration can be determined based on a plurality of constraints using an objective function, the constraints being determined based at least in part on recloser status data and/or DER power generation capability data. Respective cleared quantities of reactive power for the DERs to supply to the reconfigured power grid can be determined via a transactive control scheme, and the reconfiguration can be updated prior to implementation based on the results of the transactive control scheme.

Radhakrishnan, Nikitha↗

Improving photovoltaic hosting capacity of distribution networks with coordinated inverter control: A case study of the EPRI J1 feeder

Abstract Adding photovoltaic (PV) systems in distribution networks, while desirable for reducing the carbon footprint, can lead to voltage violations under high solar‐low load conditions. The inability of traditional volt‐VAr control in eliminating all the violations is also well‐known. This article presents a novel coordinated inverter control methodology that leverages system‐wide situational awareness to significantly improve hosting capacity (HC). The methodology employs a real‐time voltage‐reactive power (VQ) sensitivity matrix in an iterative linear optimizer to calculate the minimum reactive power intervention from PV inverters needed for mitigating over‐voltage without resorting to active power curtailing or requiring step voltage regulator setting changes. The algorithm is validated using the EPRI J1 feeder under an extensive set of realistic use cases and is shown to provide 3x improvement in HC under all scenarios.

Dalal, Dhaval [School of Electrical, Computer, and↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. An innovative concept of dispatching GFM sources (inverters and synchronous generators) is proposed to output the target power by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactive power of a GFM inverter can be achieved through dispatching its frequency and voltage. The concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; 2) The dispatch rule for grid-connected and islanded mode is slightly different.

dispatch GFM inverter↗

Learning Provably Stable Local Volt/Var Controllers for Efficient Network Operation

Here this paper develops a data-driven framework to synthesize local Volt/Var control strategies for distributed energy resources (DERs) in power distribution grids (DGs). Aiming to improve DG operational efficiency, as quantified by a generic optimal reactive power flow (ORPF) problem, we propose a two-stage approach. The first stage involves learning the manifold of optimal operating points determined by an ORPF instance. To synthesize local Volt/Var controllers, the learning task is partitioned into learning local surrogates (one per DER) of the optimal manifold with voltage input and reactive power output. Since these surrogates characterize efficient DG operating points, in the second stage, we develop local control schemes that steer the DG to these operating points. We identify the conditions on the surrogates and control parameters to ensure that the locally acting controllers collectively converge, in a global asymptotic sense, to a DG operating point agreeing with the local surrogates. We use neural networks to model the surrogates and enforce the identified conditions in the training phase. AC power flow simulations on the IEEE 37-bus network empirically bolster the theoretical stability guarantees obtained under linearized power flow assumptions. The tests further highlight the optimality improvement compared to prevalent benchmark methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model Predictive Voltage Control of Large-Scale PV or Hybrid PV-BESS Plants

Increased penetration level of inverter-based resources (IBRs) and renewable energy in the power grid has called for more requirements from the control of IBRs. In this paper, the voltage-reactive power control of a photovoltaic (PV) power plant or hybrid PV-battery energy storage system (BESS) plant connected to a bulk power grid, whilst meeting the grid requirements, is studied. In this paper, a continuous-set model predictive control (MPC) formulation is proposed for voltage-reactive power control. For the same, an aggregated dynamic PV plant model is developed based on the recursive system equivalencing method. The formulation is then implemented in PSCAD simulation on a 125 MW PV plant or hybrid PV-BESS plant. The MPC implementation achieves 10.13% voltage improvement based on PSCAD simulation results in a balanced fault case study. Simulation results further demonstrate that MPC provides improved voltage support over the conventional proportional-integral (PI) controller post-fault occurrence.

Abu rub, Omar↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Characterization of InCharge™ ICE-66 V2X Bidirectional DC Fast Charger

Vehicle-to-grid (V2G) technology extends the role of Plug-in Hybrid Vehicle’s (PHEV) and Battery Electric Vehicle’s (BEV) batteries beyond transportation by enabling bidirectional power transfer between the vehicle's onboard energy storage and the utility grid. Modern battery-powered vehicles are equipped with high-capacity battery packs that remain stationary and underutilized for the majority of their operational life. A vehicle used for daily commuting may be parked and connected to charging infrastructure for 18–20 hours per day, representing a significant untapped energy resource. When considered at scale, the aggregated storage capacity of a modest fleet of 10–15 vehicles within a single parking facility can reach the MWh range, sufficient to partially offset peak demand for a mid-size commercial building or contribute meaningful ancillary services to the local grid. The ability to charge during off-peak periods when electricity prices are low and discharge during peak demand when prices are high positions EV batteries as distributed energy arbitrage assets, with the potential to offset vehicle ownership and charging costs. Beyond energy arbitrage, V2G-capable assets can provide ancillary grid services through active and reactive power injections. Active power supports grid frequency regulation, while reactive power supports local voltage regulation. Together, these capabilities establish V2G as a technically promising and economically relevant pathway toward greater integration of battery-powered vehicles into the broader energy system.

33 ADVANCED PROPULSION SYSTEMS↗

Facets of hydro power and future trends in a Nordic Context

Hydropower technologies bolster high penetration of variable renewable energies (VREs) in the net zero emissions scenarios. Nevertheless, there are various challenges to meeting the ambitious goal, such as stability, reliability, resiliency, security, lack of reactive power, voltage support and inertia, large-scale storage deployment and coordination, interconnectedness, demand-side response, higher thermal cycles with increased start/stops, and inadequate Levelized Cost of Energy (LCOE) for system-wise VRE integration and profitability. This survey conducts a bottom-up analysis to unveil the opportunities to utilize hydropower facilities and disentangle the nested problem for intertwining design features, control algorithms, operation, optimization approaches, incentives, services, and market mechanisms using a three-pillar framework perspective: grid owners, power producers, and machine designers. The survey identified emerging trends in real-time and capacity markets, flexible power systems, and enhanced grid capabilities, including advanced voltage support and updated grid codes. These developments present significant opportunities for hydropower, such as achieving super-flexibility through hybridization, expanded reactive power capabilities, and advanced operational modes like a synchronous condenser and power adequator functionalities. These opportunities require novel design philosophies — including new winding, stator, and rotor configurations, optimized ventilation, and active cooling systems — to enhance performance under stressed grid and climate conditions. Finally, integrating climate and energy models for multi-basin optimization with finer spatial and temporal granularity enhances the planning accuracy for water management of hydropower while addressing environmental challenges. The review delivers helpful prospective suggestions and tools that would serve researchers, power engineers, and stakeholders in making decisions about hydropower technologies and services in 2050 and beyond.

13 HYDRO ENERGY↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Decoupled Droop Control Strategy for Cascaded Multicell Inverter with Low-Frequency Modulation

Cascaded multicell inverter (CMI), featured by its merits of modularity and fault-tolerance, is suitable for medium-voltage applications without using bulky step-up transformers. However, little research has reported grid-forming control of the CMI for the application in the power grid with high penetrations of inverter-interfaced generation. To bridge this research gap, this paper proposes a novel droop control strategy for the CMI with a low-frequency modulation to offer inertia and reactive power support to the power grid. A decoupled Q/V droop control strategy is proposed to eliminate the coupling effect from the P/ω control loop caused by the phase-angle difference between the voltages of the CMI and the grid. The output of the Q/V control loop is set as the reference voltage for each cell of the CMI, which makes the CMI naturally a voltage source to provide a grid-forming capability. Finally, the proposed control strategy shows great active and reactive power regulation and sharing capability, which is validated by simulation on two 100 kW, 2.4 kV CMIs connected in parallel to a power grid.

14 SOLAR ENERGY↗

Data-Driven Voltage Regulation of Distribution Grid Using Nonlinear Autoregressive Model with Exogenous Inputs (NARX)

This article proposes data-driven control via a nonlinear autoregressive model with exogenous inputs (NARX) for real-time voltage regulation of a modified feeder using reactive power sources. Traditional voltage control strategies rely on rule-based heuristics or optimization techniques, which often require detailed system models and extensive computational resources. The NARX-based controller learns system dynamics from historical data and predicts optimal reactive power dispatch in real-time for voltage correction. The proposed approach is evaluated on a power system feeder model under varying load and network conditions. Simulation results demonstrate that the NARX-based controller achieves improved voltage regulation, offering higher adaptability to system fluctuations. This study highlights the potential of data-driven control for enhancing the reliability of power distribution networks.

Donge, Vrushabh [ORNL] (ORCID:0000000306062803)↗

Introduction to Grid Forming Inverters: A Key to Transforming our Power Grid [Slides]

A grid-forming (GFM) inverter-based resource (IBR) controls maintain an internal voltage phasor that is constant or nearly constant in the sub-transient to transient time frame. This definition means that the GFM IBR will nearly immediately respond to changes in the external system and attempt to maintain IBR control during challenging network conditions to maintain grid stability. In GFM IBR, the voltage phasor is controlled to maintain synchronism with other devices in the grid while regulating the active and reactive power appropriately to support the grid. This contrasts with conventional GFL IBR controls wherein immediately after a disturbance (0-5 cycles), within the normal operating range of voltage, the output current phasor magnitude and angle remain unchanged, and the current phasor begins changing only within the transient time frame (tens of cycles) to strictly control the active and reactive power being injected into the network. This presentation gives an introduction to GFM IBR and presents the current state of the art in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Technology for Energy Sustainability: Power Electronic Converter Control for Renewables

To ensure high penetration of renewable energy sources into power grids, their interfacing inverters need to be designed to provide grid support functions. Important grid support functions include frequency and voltage support. To this end, the research community has recently invested heavily on grid-forming control pilot projects. Grid forming control aims to replace traditional grid following control, which is based on phase-locked loop and can achieve decoupled real and reactive power control. Here, in this article, we review the state-of-the-art grid following and forming technology and point out some deficiencies in dynamic performance in the widely adopted grid-forming control design. We also examine how to ensure that the vector control capable of decoupled real and reactive power regulation can also be achieved in the grid forming design. This type of design has been prototyped and shown great potential to enable retrofitting of large amounts of grid-following controllers through purely software algorithm update. The technology ensures reliable operation of power grids with high penetration of IBRs, thereby further reducing fossil fueled energy sources and cut down carbon emission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Testing Framework for Grid-Forming Resources

This paper presents a testing framework for grid-forming (GFM) resources. First, it analytically derives in the frequency domain the active and reactive power response of an ideal voltage source with a reactor. These transfer functions are then used to quantify the voltage source behavior expected from a GFM inverter within subtransient timescales (5-15 cycles) following a grid disturbance. The paper also shows that the testing of a GFM inverter might require a reactor of an appropriate size between the inverter and the grid simulator used for the inverter testing. Finally, the paper presents a systematic approach for developing specifications for GFM resources using active and reactive power response frequency scans. The testing framework and results presented in this paper are demonstrated using EMT-PSCAD simulations of a 1-MW GFM inverter.

frequency scans↗

A Testing Framework for Grid-Forming Resources: Preprint

This paper presents a testing framework for grid-forming (GFM) resources. It first analytically derives in frequency domain the active and reactive power response of an ideal voltage source with a reactor. These transfer functions are then used to quantify the voltage source behavior expected from a GFM inverter within subtransient time scales (5-10 cycles) following a grid disturbance. The paper also shows that the testing of a GFM inverter might require a reactor of an appropriate size between the inverter and the grid simulator used for the inverter testing. Finally, the paper presents a systematic approach for developing specifications for GFM resources using active and reactive power response frequency scans. The testing framework and results presented in this paper are demonstrated using EMT simulations of a 1-MW GFM inverter.

frequency scans↗