Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

First detection of VHE gamma-ray emission from TXS 1515–273, study of its X-ray variability and spectral energy distribution

ABSTRACT We report here on the first multiwavelength (MWL) campaign on the blazar TXS 1515–273, undertaken in 2019 and extending from radio to very-high-energy gamma-rays (VHE). Up until now, this blazar had not been the subject of any detailed MWL observations. It has a rather hard photon index at GeV energies and was considered a candidate extreme high-synchrotron-peaked source. MAGIC observations resulted in the first-time detection of the source in VHE with a statistical significance of 7.6σ. The average integral VHE flux of the source is 6 ± 1 per cent of the Crab nebula flux above 400 GeV. X-ray coverage was provided by Swift-XRT, XMM–Newton, and NuSTAR. The long continuous X-ray observations were separated by ∼9 h, both showing clear hour scale flares. In the XMM–Newton data, both the rise and decay time-scales are longer in the soft X-ray than in the hard X-ray band, indicating the presence of a particle cooling regime. The X-ray variability time-scales were used to constrain the size of the emission region and the strength of the magnetic field. The data allowed us to determine the synchrotron peak frequency and classify the source as a flaring high, but not extreme synchrotron-peaked object. Considering the constraints and variability patterns from the X-ray data, we model the broad-band spectral energy distribution. We applied a simple one-zone model, which could not reproduce the radio emission and the shape of the optical emission, and a two-component leptonic model with two interacting components, enabling us to reproduce the emission from radio to VHE band.

Acciari, V. A.↗

Measuring the X-ray luminosities of DESI groups from eROSITA Final Equatorial-Depth Survey – I. X-ray luminosity–halo mass scaling relation

ABSTRACT We use the eROSITA Final Equatorial-Depth Survey (eFEDS) to measure the rest-frame 0.1–2.4 keV band X-ray luminosities of ∼600 000 DESI groups using two different algorithms in the overlap region of the two observations. These groups span a large redshift range of 0.0 ≤ zg ≤ 1.0 and group mass range of $10^{10.76}\, h^{-1}\, \mathrm{M}_{\odot } \le M_h \le 10^{15.0}\, h^{-1}\, \mathrm{M}_{\odot }$. (1) Using the blind detection pipeline of eFEDS, we find that 10932 X-ray emission peaks can be cross-matched with our groups, ∼38 per cent of which have a signal-to-noise ratio $\rm {S}/\rm {N} \ge 3$ in X-ray detection. Comparing to the numbers reported in previous studies, this matched sample size is a factor of ∼6 larger. (2) By stacking X-ray maps around groups with similar masses and redshifts, we measure the average X-ray luminosity of groups as a function of halo mass in five redshift bins. We find that in a wide halo mass range, the X-ray luminosity, LX, is roughly linearly proportional to Mh and quite independent to the redshift of the groups. (3) We use a Poisson distribution to model the X-ray luminosities obtained using two different algorithms and obtain the best-fit $L_{\rm X}=10^{28.46\pm 0.03}M_{\rm h}^{1.024\pm 0.002}$ and $L_{\rm X}=10^{26.73 \pm 0.04}M_{\rm h}^{1.140 \pm 0.003}$ scaling relations, respectively. The best-fit slopes are flatter than the results previously obtained but closer to a self-similar prediction.

Astronomy & Astrophysics↗

X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the μ⁢m−sized electron bunches to fully overlap in three dimensions with the circulating μ⁢m−sized x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-μ⁢rad angular and μ⁢m spatial alignment of the CBXFEL cavity.

Free-electron lasers↗

Temperature-dependent x-ray fluorescent response from thermographic phosphors under x-ray excitation

Phosphor thermometry has been successfully applied within several challenging environments. Typically, the thermographic phosphors are excited by an ultraviolet light source, and the temperature-dependent spectral or temporal response is measured. However, this is challenging or impossible in optically thick environments. In addition, emission from other sources (e.g., a flame) may interfere with the optical phosphor emission. Furthermore, a temperature dependent x-ray excitation/emission could alleviate these issues as x-rays could penetrate obscurants with no interference from flame luminosity. In addition, x-ray emission could allow for thermometry within solids while simultaneously x-ray imaging the structural evolution. In this study, select thermographic phosphors were excited via x-ray radiation, and their x-ray emission characteristics were measured at various temperatures. Several of the phosphors showed varying levels of temperature dependence with the strongest sensitivity occurring for YAG:Dy and ZnGa 2 O 4 :Mn. This approach opens a path for less intrusive temperature measurements, particularly in optically opaque multiphase and solid phase combustion environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of Seeded Mn K β Stimulated X-Ray Emission Using Two-Color X-Ray Free-Electron Laser Pulses

Kβ x-ray emission spectroscopy is a powerful probe for electronic structure analysis of 3d transition metal systems and their ultrafast dynamics. Selectively enhancing specific spectral regions would increase this sensitivity and provide fundamentally new insights. Recently we reported the observation and analysis of Kα amplified spontaneous x-ray emission from Mn solutions using an x-ray free-electron laser to create the 1s core-hole population inversion [Kroll et al., Phys. Rev. Lett. 120, 133203 (2018)]. To apply this new approach to the chemically more sensitive but much weaker Kβ x-ray emission lines requires a mechanism to outcompete the dominant amplification of the Kα emission. Here we report the observation of seeded amplified Kβ x-ray emission from a NaMnO 4 solution using two colors of x-ray free-electron laser pulses, one to create the 1s core-hole population inversion and the other to seed the amplified Kβ emission. Comparing the observed seeded amplified Kβ emission signal with that from conventional Kβ emission into the same solid angle, we obtain a signal enhancement of more than 10 5 . Finally, our findings are the first important step of enhancing and controlling the emission of selected final states of the Kβ spectrum with applications in chemical and materials science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

Linear and Nonlinear X-ray Spectra of Chiral Molecules: X-ray Circular Dichroism, Sum- and Difference-Frequency Generation of Fenchone and Cysteine

Recent advancements in X-ray light sources enable element-sensitive nonlinear spectroscopies for probing molecular chirality. We simulate X-ray absorption spectroscopy, X-ray circular dichroism (XCD), and nonlinear optical/X-ray SFG and DFG (OX SFG/DFG) signals for two prototypical chiral molecules, fenchone and cysteine. Furthermore, our multireference simulations reproduce experimental data and reveal how novel X-ray spectroscopies exploit the site- and element-sensitivity of X-rays to uncover molecular asymmetry. The XCD spectra show strong asymmetries at chiral centers, while distant atoms contribute weaker signals. The OX SFG/DFG signals, under fixed resonant optical excitation, strongly depend on the core and valence excitations. This allows us to introduce two-dimensional (2D) chirality-sensitive valence-core spectroscopy, which provides insight into the overlap between valence orbitals and local molecular asymmetry. Finally, our estimates using realistic laser and X-ray pulse parameters demonstrate that such nonlinear experiments are feasible at XFELs, offering a promising tool for investigating chiral molecules.

Circular dichroism spectroscopy↗

Determination of X-ray detection limit and applications in perovskite X-ray detectors

X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.

47 OTHER INSTRUMENTATION↗

High dynamic range CdTe mixed-mode pixel array detector (MM-PAD) for kilohertz imaging of hard x-rays

A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 µm thick cadmium telluride (CdTe) sensor. The full imager is a 2 × 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficient x-ray imaging to extend to >100 keV. The detector is capable of 1 kHz imaging and in-pixel circuitry has been designed to allow for well depths of greater than 4 × 10 6 80 keV x-rays. Here, a charge integrating front-end allows for quantitative measurement of high flux x-ray images beyond the capabilities of photon counting detectors. Detector performance is summarized and experimental measurements are presented.

99 GENERAL AND MISCELLANEOUS↗

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗

X-Ray Spectroscopic Studies of X-Pinch Plasmas with 3-5 Picosecond Resolution: A Quest for Clear Experimental Evidence for Radiative Collapse in the X-ray Spectra (Final Report)

Dense Z-pinch plasmas produced from current-carrying exploding wires frequently produce very brief (less than 0.1 nanosecond), intense, bursts of soft X-rays from tiny (about 1 micrometer), very hot (10-30 million K) regions of the plasma. This project addresses the physical processes that lead to those tiny, high-energy density plasmas and develops means to measure the conditions just before and during the X-ray bursts. One possible relevant process is radiative collapse, which starts if the power radiated by a dense Z-pinch, proportional to the density-squared, exceeds the resistive heating rate from the current flow, thereby cooling the plasma and enabling the magnetic pinching force to exceed the outward plasma thermal pressure. As the resulting radius reduction further increases the radiation rate, this process produces a runaway magnetic implosion. A competing mechanism is a sausage-like instability that can develop in a Z-pinch plasma at a lower current than is needed to induce radiative collapse. This mechanism can also produce tiny hot spots in the neck regions of the sausage-shaped plasma column. It is also possible that these two mechanisms work together to produce the X-ray emitting hot spots. If radiative collapse does contribute to hot spot formation, it would be terminated when the plasma becomes so dense that the radiation cannot escape, enabling the plasma kinetic pressure to build up and stop the current-driven implosion. This project aims to study the development of the hot spots by means of high temporal and spatial resolution X-ray spectroscopy to determine if there is evidence for the presence of the radiative collapse mechanism. Progress toward this goal is presented. To summarize, during the four-year period 09/15/2017 - 9/14/2021, we have collected necessary spectroscopic data to determine the plasma conditions and continue to do so. We are also now in the process of calibrating diagnostic systems (especially the x-ray streak camera system) and analyzing data to determine plasma conditions as a function of time before, during and after the X-ray burst.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rays for Roots - Integrating Backscatter X-Ray Phenotyping, Modeling and Genetics to Increase Carbon Sequestration and Switchgrass Resource Use (Final Report)

To increase carbon (C) deposition in the soil and enhance crop resource use efficiency, characterizing root form and function is essential. Several root and soil traits have been linked to increased root-to-soil C transfer. Technology that could provide high-resolution characterization of many of these traits in field conditions would revolutionize our ability to study and understand how to increase C sequestration. In this effort, we developed an initial early prototype backscatter X-ray system for non-destructive imaging of root traits. We collected initial backscatter X-ray data in field and lab settings and carried out early analysis of these data. Along with this prototype, we also developed a suite of root phenotyping approaches including advanced minirhizotron image analysis, soil core imaging, and mesocosm imaging. Minirhizotron (MR) tubes are clear tubes inserted into the soil in the field and used to image roots and the surrounding soil. Our team has developed deep learning-based methods that can segment roots from soil that can learn from imprecise image-level labels. The ability to learn or fine-tune our deep learning algorithms from image-level labels allows easier and faster application of these approaches to new locations and new plant species. We have successfully implemented and applied our MR analysis approaches to thousands of switchgrass MR images collected across geographical regions. An advantage of MR imaging is the ability to collect root and soil images over time. Our soil core analysis included collecting hundreds of soil core samples from harvested switchgrass fields and imaging these cores with both X-ray CT and backscatter X-ray imaging. Initial segmentation approaches for the X-ray CT images of these cores have been developed and applied. An advantage of soil core analysis is that it preserves the three-dimensional structures of the roots and soil in the core collected. Our group also developed photogrammetry-based mesocosm root imaging and phenotyping approaches. In this approach, a plant was grown in a large mesocosm with a three-dimensional grid of thin supporting lines inserted throughout the mesocosm. After the plant (and, correspondingly, the root architecture is grown and established) the soil media was removed and the supporting lines approximately preserved the three-dimensional root architecture. Then, we applied photogrammetry techniques to create a three-dimensional digital representation of the root architecture for which we developed analysis algorithms including skeletonization. We carried out our phenotyping development with powerful switchgrass resources and physiological and agroecosystem modeling to deliver novel technology. This project contributes to multiple ARPA-E missions including reduction of foreign imports of energy, reduction of energy-related emissions including greenhouse gases, and ensuring that the United States maintains a technological lead in developing and deploying advanced energy technology. Furthermore, the developed tools could transform public and private plant breeding and could be broadly applicable to other crops and, potentially, other application areas. Our team of engineers, plant and soil scientists, and modelers i) developed an early prototype backscatter X-ray platform that can operate in field conditions; ii) developed a suite of root phenotyping and characterization approaches as described above; iii) developed and carried out plant biology and physiology roots studies and; iv) developed and implemented mechanistic physiological modeling.

42 ENGINEERING↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗

Interfacial properties in energy storage systems studied by soft x-ray absorption spectroscopy and resonant inelastic x-ray scattering

Interfacial behaviors and properties play critical roles in determining key practical parameters of electrochemical energy storage systems, such as lithium-ion and sodium-ion batteries. Soft x-ray spectroscopy features shallow penetration depth and demonstrates inherent surface sensitivity to characterize the interfacial behavior with elemental and chemical sensitivities. Here, we present a brief survey of modern synchrotron-based soft x-ray spectroscopy of the interface in electrochemical energy storage systems. The technical focus includes core-level spectroscopy of conventional x-ray absorption spectroscopy and resonant inelastic x-ray scattering (RIXS). We show that while conventional techniques remain powerful for probing the chemical species on the surface, today’s material research studies have triggered much more demanding chemical sensitivity that could only be offered by advanced techniques such as RIXS. Another direction in the field is the rapid development of various in situ/operando characterizations of complex electrochemical systems. Notably, the solid-state battery systems provide unique advantages for future studies of both the surface/interface and the bulk properties under operando conditions. We conclude with perspectives on the bright future of studying electrochemical systems through these advanced soft x-ray spectroscopic techniques.

25 ENERGY STORAGE↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

Identification and Suppression of Point Defects in Bromide Perovskite Single Crystals Enabling Gamma‐Ray Spectroscopy

Abstract Methylammonium lead tribromide (MAPbBr 3 ) stands out as the most easily grown wide‐band‐gap metal halide perovskite. It is a promising semiconductor for room‐temperature gamma‐ray ( γ ‐ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance. Here, through a combination of crystal growth design and defect characterization, including positron annihilation and impedance spectroscopy, the presence of specific point defects are identified and correlated to detector performance. Methylammonium (MA) vacancies, MA interstitials, and Pb vacancies are identified as the dominant charge‐trapping defects in MAPbBr 3 crystals, while Br vacancies caused doping. The addition of excess MABr reduces the MA and Br defects and so enables the detection of energy‐resolved γ ‐ray spectra using a MAPbBr 3 single‐crystal device. Interestingly, the addition of formamidinium (FA) cations, which converted to methylformamidinium (MFA) cations by reaction with MA + during crystal growth further reduced MA defects. This enabled an energy resolution of 3.9% for the 662 keV 137 Cs line using a low bias of 100 V. The work provides direction toward enabling further improvements in wide‐bandgap perovskite‐based device performance by reducing detrimental defects.

Ni, Zhenyi↗

Analysis of X-ray images and spectra (aXis2000): A toolkit for the analysis of X-ray spectromicroscopy data

Spectromicroscopy refers to analytical methods that combine imaging and spectroscopy to provide detailed, spatially resolved analytical information about a sample, such as the type and quantitative spatial distributions of chemical components, geometric or magnetic alignment information, crystal structure, etc. The analysis of X-ray images and spectra (aXis2000) software described in this work provides a set of routines within a single, integrated, graphical-oriented package to read, display, manipulate and analyze spectromicroscopy data, with particular focus on soft X-ray spectromicroscopy methods such as scanning transmission X-ray microscopy (STXM), X-ray photoemission electron microscopy (XPEEM), scanning photoelectron X-ray microscopy (SPEM) and transmission X-ray microscopy (TXM). Here, this free software is described and compared to other software that can provide similar or complementary capabilities. Examples of spectromicroscopic analyses using advanced features of aXis2000 are provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗