Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiography modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Cathode to Target Simulations for Scorpius: I. Simulation Codes and Models

The new Scorpius linear induction electron accelerator is under development for multi-pulse flash radiography of large, explosively-driven hydrodynamic experiments. Beam physics from the cathode to the target was examined with computer simulations, including envelope, ray-trace, and particle-in cell (PIC) codes. Beam instabilities investigated included beam breakup (BBU), image displacement, diocotron, parametric envelope, ion hose, and the resistive wall instability. Beam corkscrew motion and emittance growth from beam mismatch were also studied. The results of these simulations is documented in a series of reports. In this report the computer codes and physical models used for these simulations are described. The conclusion of this study is that Scorpius will produce and accelerate a beam with radiographic quality equivalent to the present accelerators at Los Alamos National Laboratory if the same engineering standards and construction details are upheld.

43 PARTICLE ACCELERATORS↗

Experimental Safe Extremum Seeking for Accelerators

Here, we demonstrate the recent designs of safe extremum seeking (Safe ES) on the 1-km-long charged particle accelerator at the Los Alamos Neutron Science Center (LANSCE). Safe ES is a modification of extremum seeking (ES) which, in addition to minimizing an analytically unknown cost, also employs a safety filter based on an analytically unknown control barrier function (CBF) safety metric. Tuning is necessitated by accelerators being large complex systems, with many drifting parameters due to thermal effects and degradation. At the same time, safe operation (the maintenance of state constraints) is crucial, as damage brings astronomical costs, both financially and in operation downtime. Our measured (but analytically unknown) safety metric is the beam current. We perform multivariable Safe ES on three accelerator applications, in which we adapt 4, 6, and 3 magnet strength parameters, respectively. Two of the three applications are for validated simulation models of beamlines at LANSCE: the first for the proton radiography (pRad) beamline of 800-MeV protons for spot size tuning; the second on a high-performance code, HPSim, for tuning the low-energy beam transport (LEBT) region that contains a beam of 750-keV protons. The third is an experimental tuning of the steering magnets in the LEBT at LANSCE.

43 PARTICLE ACCELERATORS↗

Toward an integrated platform for characterizing laser-driven, isochorically heated plasmas with 1 µm spatial resolution

Warm dense matter is a region of phase space that is of high interest to multiple scientific communities ranging from astrophysics to inertial confinement fusion. Further understanding of the conditions and properties of this complex state of matter necessitates experimental benchmarking of the current theoretical models. We discuss the development of an x-ray radiography platform designed to measure warm dense matter transport properties at large laser facilities such as the OMEGA Laser Facility. Our platform, Fresnel Diffractive Radiography, allows for high spatial resolution imaging of isochorically heated targets, resulting in notable diffractive effects at sharp density gradients that are influenced by transport properties such as thermal conductivity. We discuss initial results, highlighting the capabilities of the platform in measuring diffractive features with micron-level spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical Sciences Vistas: Issue 4 2021

In this issue of Physical Sciences Vistas we highlight examples of “excellence in nuclear security.” In this issue, highlights of our outstanding work supporting the Laboratory’s nuclear security enterprise include the following: The complete refurbishment of Sigma’s surface finishing lab. Pride in the lab’s revitalized condition on the part of the operations and R&D staff responsible for this complex operation is well justified. Development of advanced materials and processes enabling next-generation weapons designs, much of which has been facilitated by projects supported by the Laboratory Directed Research and Development Program. The use of proton radiography in illuminating elements important to validating high explosive burn models. The experimental series was a collaboration between Los Alamos researchers and staff at Lawrence Livermore and Sandia national laboratories and the United Kingdom’s Atomic Weapons Establishment. Deployment of a sophisticated remote handling unit to safely transfer highly radioactive materials required to support mission-critical projects. The skillful swap of an electrical transformer at the Los Alamos Neutron Science Center (LANSCE). The deliberate operation restored power to the accelerator in less than estimated time. A look at George Goff ’s role in translating fundamental science into applied solutions essential to the Lab’s nuclear security mission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct imaging of shock wave splitting in diamond at Mbar pressure

Understanding the behavior of matter at extreme pressures of the order of a megabar (Mbar) is essential to gain insight into various physical phenomena at macroscales—the formation of planets, young stars, and the cores of super-Earths, and at microscales—damage to ceramic materials and high-pressure plastic transformation and phase transitions in solids. Under dynamic compression of solids up to Mbar pressures, even a solid with high strength exhibits plastic properties, causing the induced shock wave to split in two: an elastic precursor and a plastic shock wave. This phenomenon is described by theoretical models based on indirect measurements of material response. The advent of x-ray free-electron lasers (XFELs) has made it possible to use their ultrashort pulses for direct observations of the propagation of shock waves in solid materials by the method of phase-contrast radiography. However, there is still a lack of comprehensive data for verification of theoretical models of different solids. Here, we present the results of an experiment in which the evolution of the coupled elastic–plastic wave structure in diamond was directly observed and studied with submicrometer spatial resolution, using the unique capabilities of the x-ray free-electron laser (XFEL). The direct measurements allowed, for the first time, the fitting and validation of the 2D failure model for diamond in the range of several Mbar. Our experimental approach opens new possibilities for the direct verification and construction of equations of state of matter in the ultra-high-stress range, which are relevant to solving a variety of problems in high-energy-density physics.

36 MATERIALS SCIENCE↗

Material Identification Using Dual Energy X-ray Absorptiometry

Two implementations of dual energy X-ray absorptiometry were studied to identify materials using X-ray attenuation data taken with the Digital Radiography and Computed Tomography (DRCT) systems that were developed for the Recovered Chemical Materiel Directorate (RCMD). Maitrejean et al.’s approach utilizes eigen effects through Principal Component Analysis, while Osipov et al.’s approach proposed a physics-based method. Both approaches approximate mass attenuation coefficients of materials as a linear combination of basis functions (eigen effects) or physics-based equations. A set of coefficients {a 1 , a 2 , a 3 } or {B, D} were found by parameter optimization in EXCEL Solver. The identification parameters, {$\frac{a_{2}}{a_{1}}$, $\frac{a_{3}}{a_{1}}$} or estimated effective atomic number $\hat{Z}$ from {B, D}, were calculated to identify material of an aluminum 8 step wedge and a steel 8 step wedge in X-ray radiography images taken by a DRCT system. Maitrejean et al.’s approach was unable to provide reliable $\frac{a_{3}}{a_{1}}$ ratio values for identification of materials. Osipov et al.’s approach was found to be more robust in identify materials with a semi-empirical formula derived from test results in this study.

36 MATERIALS SCIENCE↗

Assessing High Burnup U-19Pu-10Zr Fuel Performance against Historical and Modeled Behavior

Advancing the deployment of sodium-cooled fast reactors (SFRs) requires thorough testing of metallic fuel pins under accident conditions to establish safe operational limits of high burnup fuel. To conduct transient testing, a comprehensive understanding of steady-state fuel behavior obtained through both experimental characterization and accurate predictive capabilities is needed. This study comparatively assesses the steady-state irradiation performance of two high burnup U-19Pu-10Zr fuel pins, DP-36 and DP-40, irradiated under prototypic fast reactor conditions in preparation for planned safety testing at the Transient Reactor Test Facility. Since DP-40 was designated for use in the test and DP-36 serves as its sibling pin, non-destructive, engineering-scale post-irradiation examinations (PIE) were conducted on both pins while destructive examinations were performed exclusively on DP-36. The results were then assessed against historical performance data from similar fuel pins irradiated in the Experimental Breeder Reactor-II. Additionally, the steady-state irradiation of each pin was modeled using the BISON fuel performance code to assess the accuracy of current modeling capabilities in predicting the baseline irradiation behavior. Non-destructive examinations included neutron radiography to measure fuel column elongation, gamma scanning to verify pin integrity and fission product migration, and profilometry to assess dimensional changes. Benchmarking against existing PIE data revealed consistent patterns in axial fuel column growth and cladding diametral strain, though both pins exhibited longer low-density “fluff” structures, which can have implications for core reactivity and source term calculations. Destructive examinations on DP-36 included fission gas release analysis and sectioning for optical microscopy, which showed more complex constituent redistribution patterns than the traditionally accepted 3-ring model. The axial evolution of fractional areas and porosities of each of the redistributed zones were quantified and presented. Modeling comparisons showed agreement in fractional fission gas release but consistently overestimated axial and radial swelling and disagreed with measured axial porosity patterns. These conservative overpredictions suggested that the pins would appear closer to failure or operational limits at the start of transient tests, potentially leading to higher strain accumulation during the transient. While conservative estimates provide safety margins, they can negatively impact fuel economics. A review of the swelling models identified areas for improvement in the gaseous swelling, solid swelling, and fuel hot-pressing models when applied to ternary fuel. The results of this study highlight the critical importance of conducting pre-test characterization on both test and sibling pins to accurately capture steady-state fuel behavior, providing a precise baseline for post-test evaluations and essential inputs for transient modeling of the planned experiments. The analysis also revealed significant data gaps that require further investigation to enhance the understanding and prediction of fuel swelling and pore dynamics. Collecting comprehensive data across different irradiation conditions, burnup levels, and fuel compositions are essential for refining existing models and developing mechanistic models for both binary and ternary metallic fuels, ultimately improving the integration of modeling and experimental approaches in accident testing.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

w22_laser-radiography: Laser-Based MeV Radiography [Slides]

X-ray sources based on high-power short pulse lasers have unique advantages over conventional sources, like small spot size, flexible configuration, and tailorable spectra. Development of these sources will allow LANL to fulfill an urgent need to deploy flexible, compact, x-ray sources for static and dynamic radiography at our firing sites and facilities such as pRad and U1a. Our IC allocation supports the development of a predictive modeling capability of these laser-based sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Throughput Uniformity and Defect Monitoring in Low-Temperature Electrolysis Porous Transport Layers Using X-Ray Radiography

Effective quality control (QC) for manufacturing proton exchange membrane water electrolysis (PEMWE) components is critical to enabling widespread adoption of the technology for hydrogen generation. This study investigates X-ray radiography as a novel, high-throughput, potentially in-line QC technique for detecting defects and assessing material property distributions in titanium-based porous transport layers (PTLs) which constitute a crucial component of low temperature PEMWE stacks. We obtain radiographs of a set of fifteen PTLs and model their absorbance of the broadband radiation as a second-order polynomial to account for the non-monoenergetic radiation source used in this study. The resulting model serves as a basis for predicting the areal density and porosity distributions of the PTLs. We find radiography successful in detecting multiple instances of defects, including holes/depressions, cracks, and excess material on the surface or in the pores of the material, demonstrating its potential as a robust in-line QC tool for PTL manufacturing.

08 HYDROGEN↗

A physics-driven Σ-Y atomization model for heavy-duty engine simulations

The atomization of a liquid jet is a multi-scale and multi-physics problem of interest for many engineering applications. Particularly, it drives the fuel-oxidizer mixing and dictates the efficiency of combustion engines. High-fidelity multi-phase simulations remain challenging due to the excessive computational cost required to capture all the atomization scales. Thus, atomization models are necessary to represent sub-grid liquid structures. Here, in this work, a modified Σ-Y model in the context of Eulerian-Lagrangian Spray Atomization (ELSA) is used to transport the surface area density of the spray. The model's predictive performance is assessed under various operating conditions relevant to heavy-duty engines using the Engine Combustion Network (ECN) Spray C and Spray D research-grade injectors. The classic droplet collision formulation of the Σ-Y model alone does not replicate the response of the measured spray surface area to changes in injector, ambient pressure, and injection pressure, requiring individual tuning of the model's parameters. Instead, a transition between dense and dilute spray breakup mechanisms is proposed in terms of the average droplet spacing. The collision breakup mechanism represents the dilute spray, whereas the droplet size in the dense spray is driven by a competition between the integral scale of turbulence and the balance between the turbulent kinetic energy and the surface energy of the droplets. Such an approach minimizes the requirements for model tuning. Moreover, the role of the constants of a compressible standard k-ε RANS model is assessed in the injector's internal flow and external spray simulation framework, and an updated set is proposed. The results are validated against x-ray radiography and Ultra-Small Angle X-ray Scattering (USAXS) data and highlight the predictive capabilities of the proposed physics-driven Σ-Y model, which is compatible with engine simulation turnaround times.

42 ENGINEERING↗

Multi-Probe 24A Pre-Shot report

The Multi-Probe Radiography campaign will field a full day of experiments at the Omega EP laser facility. The day consists of shots alternating between Omega EP’s two short-pulse laser beams. The Backlighter beam will generate proton and deuteron beams from 500-800nm CH/CD film targets, and the Sidelighter beam will accelerate electrons to generate x-rays from 0.5mm x 25-50µm Ø Ta wire targets attached to Compound Parabolic Concentrator (CPC) cones. The ion beams shots will optimize CD foil thickness (maximizing ion energy/yield) for the transparency regime for use as the pitcher in a pitcher catcher neutron-generation platform. Several shots will include a LiF catcher within the NTA and this feeds into future neutron radiography work. X-ray shots will be used to characterize the platform established in FY2020B via measurement of electron spectra with and without the Ta wire, and radiography will be conducted at varying laser energies. This will validate PIC electron acceleration modeling while also demonstrating potential for using the x-ray platform for imaging of thicker objects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal transport in warm dense matter revealed by refraction-enhanced x-ray radiography with a deep-neural-network analysis

Abstract Transport properties of high energy density matter affect the evolution of many systems, ranging from the geodynamo in the Earth’s core, to hydrodynamic instability growth in inertial confinement fusion capsules. Large uncertainties of these properties are present in the warm dense matter regime where both plasma models and condensed matter models become invalid. To overcome this limit, we devise an experimental platform based on x-ray differential heating and time-resolved refraction-enhanced radiography coupled to a deep neural network. We retrieve the first measurement of thermal conductivity of CH and Be in the warm dense matter regime and compare our measurement with the most commonly adopted models. The discrepancies observed are related to the estimation of a correction term from electron-electron collisions. The results necessitate improvement of transport models in the warm dense matter regime and could impact the understanding of the implosion performance for inertial confinement fusion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure of Self-Generated Magnetic Fields in Laser-Solid Interaction from Proton Tomography

Self-generated magnetic fields in laser-solid interactions are experimentally characterized to reveal the 3D location and local field strength, rather than path-integrated quantities, using multi-view proton radiography and tomographic inversion. We infer magnetic fields that extend several millimeters off the target into the hot, rarefied corona, sufficient to strongly magnetize the plasma (Ω e τ e ≫ 1). The data are compared to MHD simulations incorporating recent improvements in modeling magnetic field generation and transport; the volume-averaged coronal field strength and magnetic flux agree to within 25% using a model with magnetic re-localization of transport, although the near-target morphology is not reproduced. This work demonstrates tomographic proton radiography as a valuable tool for investigating magnetic fields in laser-produced plasmas.

High-energy-density plasmas↗

Quantitative uranium elemental reconstruction using spectral x-ray radiography

X-ray radiography offers the ability to noninvasively inspect the internal structure and material composition of objects. Dual-energy radiography allows material discrimination but is limited in quantitative material measurements due to the broad nature of the interrogating x-ray spectrum. Spectral radiography detectors provide an observation of not just the number of x rays that are transmitted through a sample but also the spectrum. Here, experimental validations of a method to use spectral x-ray radiography to accurately quantify the uranium mass in a powder are presented. An accurate system response model was developed, which includes a model of the incident x-ray source spectrum and a pixel-wise detector response that describes how the transmitted x rays were observed. Further, a calibration to account for the effect of partial x-ray attenuation was developed. As a result, the method is demonstrated to be capable of estimating the uranium mass in a variety of uranium oxide powders to a bias of –0.01±0.62%.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Review of Doses for Dental Imaging in 2010–2020 and Development of a Web Dose Calculator

Dental imaging is one of the most common types of diagnostic radiological procedures in modern medicine. We introduce a comprehensive table of organ doses received by patients in dental imaging procedures extracted from literature and a new web application to visualize the summarized dose information. We analyzed articles, published after 2010, from PubMed on organ and effective doses delivered by dental imaging procedures, including intraoral radiography, panoramic radiography, and cone-beam computed tomography (CBCT), and summarized doses by dosimetry method, machine model, patient age, and technical parameters. Mean effective doses delivered by intraoral, 1.32 (0.60–2.56) μSv, and panoramic, 17.93 (3.47–75.00) μSv, procedures were found to be about1% and 15% of that delivered by CBCT, 121.09 (17.10–392.20) μSv, respectively. In CBCT imaging, child phantoms received about 29% more effective dose than the adult phantoms received. The effective dose of a large field of view (FOV) (>150 cm2) was about 1.6 times greater than that of a small FOV (<50 cm2). The maximum CBCT effective dose with a large FOV for children, 392.2 μSv, was about 13% of theeffective dose that a person receives on average every year from natural radiation, 3110 μSv. Monte Carlo simulations of representative cases of the three dental imaging procedures were then conducted to estimate and visualize the dose distribution within the head. The user-friendly interactive web application (available at http://dentaldose.org) receives user input, such as the number of intraoral radiographs taken, and displays total organ and effective doses, dose distribution maps, and a comparison with other medical and natural sources of radiation. The web dose calculator provides a practical resource for patients interested in understanding the radiation doses delivered by dental imaging procedures.

Lee, Hawon↗

Transport of an intense proton beam from a cone-structured target through plastic foam with unique proton source modeling

Laser-accelerated proton beams are applicable to several research areas within high-energy density science, including warm dense matter generation, proton radiography, and inertial confinement fusion, which all involve transport of the beam through matter. Here, we report on experimental measurements of intense proton beam transport through plastic foam blocks. The intense proton beam was accelerated by the 10 ps, 700 $\textit{J}$ OMEGA EP laser irradiating a curved foil target, and focused by an attached hollow cone. The protons then entered the foam block of density 0.38 g/cm 3 and thickness 0.55 or 1.00 mm. At the rear of the foam block, a Cu layer revealed the cross section of the intense beam via proton- and hot electron-induced Cu-K α emission. Images of x-ray emission show a bright spot on the rear Cu film indicative of a forward-directed beam without major breakup. 2D fluid-PIC simulations of the transport were conducted using a unique multi-injection source model incorporating energy-dependent beam divergence. Along with postprocessed calculations of the Cu – $K_α$ emission profile, simulations showed that protons retain their ballistic transport through the foam and are able to heat the foam up to several keV in temperature. The total experimental emission profile for the 1.0 mm foam agrees qualitatively with the simulated profile, suggesting that the protons indeed retain their beamlike qualities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of a Thermo-Ablative Model of Elastomeric Internal Insulation Materials

In thermo-ablative material modeling, as in many fields of analysis, the quality of the existing models significantly exceeds that of the experimental data required for their validation. In an effort to narrow this gap, a laboratory-scale internal insulation test bed was developed that exposes insulation samples to realistic solid rocket motor (SRM) internal environments while being instrumented to record real-time rates of both model inputs (i.e., chamber pressure, total surface heat flux, and radiative heat flux) as well as model outputs (i.e., material decomposition depths (MDDs) and in-depth material temperatures). In this work, the measured SRM internal environment parameters were used in conjunction with equilibrium thermochemistry codes as inputs to one-dimensional thermo-ablative models of the PBINBR and CFEPDM insulation samples used in the lab-scale test firings. The computed MDD histories were then compared with those deduced from real-time X-ray radiography of the insulation samples, and the calculated in-depth temperatures were compared with those measured by embedded thermocouples. The results of this exercise emphasize the challenges of modeling and testing elastomeric materials in SRM environments while illuminating the path forward to improved fidelity.

Martin, Heath T.↗

Optimizing time integration for accurate recovery of shockwave interface location in radiography

We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.

Bremsstrahlung↗