The Dual-Axis Radiographic Hydrodynamic Test Facility Capability Expansion (DCX) Strategy

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility is a vital and important part of the Nation’s nuclear security enterprise. With more than two decades of operations, DARHT has a storied history. Conceived in the 1970s, constructed in the 1990s, and operational since 2000, DARHT has advanced from open-air hydrodynamic experiments (hydros) to foam-confined hydros, to vessel-confined hydros, and in 2022, the 75th hydro was successfully completed. Radiography has advanced from a single-axis, single-pulse system to a dual-axis, multi-pulse capability to variable fields of view (VFV) on both accelerators. The culmination of these experiences, accomplishments, and advancements has brought us to a very important question: What do the next two decades at DARHT look like? The world is not the same place it was in the 1990s when construction at DARHT was in progress. Evolving threats, an expanding mission, and technology changes necessitate adaptation. To adapt, the aging facility, accelerators, vessels, and detector systems require improvements to ensure DARHT remains the Nation’s hydrodynamic data foundation for stockpile certification, safety, surety, and global security threats.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Dual-Axis Radiographic Hydrodynamic Test Facility Capability eXpansion (DCX) Strategy

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility is a vital and important part of the Nation’s nuclear security enterprise. The Department of Energy/National Nuclear Security Administration (DOE/ NNSA) Stockpile Stewardship Management Plan (SSMP) identifies DARHT as a weapons mission critical facility along with the need to modernize DARHT to support weapons modernization efforts. With more than two decades of operations, DARHT has a storied history. Conceived in the 1970s, constructed in the 1990s, and operational since 2000, DARHT has advanced from open-air hydrodynamic experiments (hydros) to foam-confined hydros, to vessel-confined hydros, and in 2022, the 75 th hydro was successfully completed. Radiography has advanced from a single-axis, single-pulse system to a dual-axis, multi-pulse capability to variable fields of view (VFV) on both accelerators. The culmination of these experiences, accomplishments, and advancements has brought us to a very important question: What do the next two decades at DARHT look like? The world is not the same place it was in the 1990s when construction at DARHT was in progress. Evolving threats, an expanding mission, and technology changes necessitate adaptation. The 2018 Nuclear Posture Review (NPR) states that the nuclear weapons infrastructure has suffered the effects of age and underfunding with no margin for further delay in recapitalizing the physical infrastructure. To adapt, the aging facility, accelerators, vessels, and detector systems require improvements to ensure DARHT remains the Nation’s hydrodynamic data foundation for stockpile certification, safety, surety, and global security threats.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Workshop on Radiographic Imaging and Applications Research and Development Recommendations for Field Radiography

The Workshop on Radiographic Imaging and Applications (WORIA) brought together subject matter experts from industry, academia, US and UK government agencies, and the national laboratories to provide a forum to liaise and share information between technology developers in government and industry, end users, and mission stakeholder to produce an “expert consensus view” regarding future research directions toward a comprehensive radiography/penetrating imaging portfolio in the Defense Nuclear Nonproliferation Research and Development Near Field Detection Portfolio. The inaugural WORIA was held at the Spallation Neutron Source at Oak Ridge National Laboratory on February 7–9, 2023. The inaugural WORIA meeting focused on field radiography applications, or situations in which a portable imaging system must be brought to an item of interest (rather than the item brought to an imaging facility). This report documents consensus views derived from the meeting and provides research and development recommendations for federal program managers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Dual-Axis Radiographic Hydrodynamic Test Facility Capability eXpansion (DCX) Strategy

This document details the strategy proposed to meet the National Nuclear Security Administration (NNSA) requirement for the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility Sustainment and Modernization projects identified in multiple NNSA Stockpile Stewardship and Management Plan (SSMP) reports to Congress [NNSA, 2020; 2021; 2022; 2023; 2024]. DARHT has become indispensable for the certification of the primaries of U.S. nuclear weapons since the current U.S. moratorium halted underground nuclear testing more than 30 years ago. However, aging facilities, evolving technology, and other issues are limiting or threatening the capability of DARHT to meet NNSA’s expanding mission needs now and into the future. This DARHT Capability eXpansion (DCX) strategy was developed to address NNSA needs by extending DARHT’s reliability and resilience, increasing the quality and quantity of DARHT data, and enabling hydrodynamic measurements in complex environments. The strategy can be implemented through integration of line-item projects, acquisition of major items of equipment, and other actions coordinated with the execution of the SSMP. This strategy document is intended for U.S. Government officials, particularly authorizers, appropriators, and program leaders. It may also be furnished to DARHT users, customers, collaborators, stakeholders, and visitors as needed

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus ‘super-resolution’). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

47 OTHER INSTRUMENTATION↗

Enhancing segmentation fairness through curriculum learning and progressive loss: a centralized and federated perspective on radiograph analysis

Bias in medical image segmentation can lead to unequal performance across demographic subgroups, raising concerns about fairness and reliability in clinical AI systems. While deep learning models have achieved high segmentation accuracy, ensuring equitable performance across race and gender remains a significant challenge, particularly in privacy-sensitive healthcare environments. This study investigates fairness-aware medical image segmentation for hip and knee radiographs using deep learning models evaluated in both centralized and Federated Learning (FL) settings. We introduce Curriculum Learning (CL) strategies and Progressive Loss (PL) functions to regulate sample difficulty during training. In addition, we propose two novel fairness-oriented federated learning algorithms, Federated Intersection over Union (FedIoU) and Federated Intersection over Union with Outlier Analysis (FedIoUoutlier). Experiments are conducted using multiple segmentation backbones and simulated multi-site data partitions derived from the Osteoarthritis Initiative dataset. Model performance is evaluated using Intersection over Union (IoU), IoU standard deviation, Skewed Error Ratio (SER), and Min-Max Disparity across race and gender subgroups. Statistical significance was verified using paired t-tests to compare per-sample IoU performance against baseline configurations. Across both hip and knee segmentation tasks, curriculum learning and progressive loss strategies consistently improved segmentation accuracy and reduced demographic performance disparities in centralized training. In federated settings, fairness-aware aggregation further enhanced performance. Notably, FedIoUoutlier combined with balanced curriculum learning and tiered progressive loss achieved the highest mean IoU while yielding the lowest SER and Min-Max Disparity, indicating improved fairness without sacrificing accuracy. In several configurations, federated models matched or exceeded the performance of optimized centralized models, with statistically significant improvements in per-sample IoU over baseline configurations. The results demonstrate that structured training strategies and fairness-aware federated aggregation can jointly improve accuracy, stability, and demographic fairness in medical image segmentation. By integrating curriculum learning, progressive loss, and novel FL algorithms, this work provides a practical pathway toward equitable and privacy-preserving AI systems for medical imaging.

97 MATHEMATICS AND COMPUTING↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus $super$-$resolution$). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of TNSA proton radiography on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) Laser

We report that proton radiography using short-pulse laser drivers is an important tool in high-energy density (HED) science for dynamically diagnosing key characteristics in plasma interactions. Here we detail the first demonstration of target-normal sheath acceleration (TNSA)-based proton radiography the NIF-ARC laser system aided by the use of compound parabolic concentrators (CPCs). The multi-kJ energies available at the NIF-ARC laser allows for a high-brightness proton source for radiography and thus enabling a wide range of applications in HED science. In this demonstration, proton radiography of a physics package was performed and this work details the spectral properties of the TNSA proton probe as well as description of the resulting radiography quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Domain Shift Analysis in Chest Radiographs Classification in a Veterans Healthcare Administration Population

This study aims to assess the impact of domain shift on chest X-ray classification accuracy and to analyze the influence of ground truth label quality and demographic factors such as age group, sex, and study year. We used a DenseNet121 model pre-trained MIMIC-CXR dataset for deep learning-based multi-label classification using ground truth labels from radiology reports extracted using the CheXpert and CheXbert Labeler. We compared the performance of the 14 chest X-ray labels on the MIMIC-CXR and Veterans Healthcare Administration chest X-ray dataset (VA-CXR). The validation of ground truth and the assessment of multi-label classification performance across various NLP extraction tools revealed that the VA-CXR dataset exhibited lower disagreement rates than the MIMIC-CXR datasets. Additionally, there were notable differences in AUC scores between models utilizing CheXpert and CheXbert. When evaluating multi-label classification performance across different datasets, minimal domain shift was observed in the unseen VA dataset, except for the label “Enlarged Cardiomediastinum.” The subgroup with the most significant variations in multi-label classification performance was study year. These findings underscore the importance of considering domain shift in chest X-ray classification tasks, paying particular attention to the temporality of the exam. Our study reveals the significant impact of domain shift and demographic factors on chest X-ray classification, emphasizing the need for improved transfer learning and robust model development. Addressing these challenges is crucial for advancing medical imaging research and improving patient care.

chest X-ray image classification↗

Modeling hydrodynamics, magnetic fields, and synthetic radiographs for high-energy-density plasma flows in shock-shear targets

Three-dimensional FLASH radiation-magnetohydrodynamics (radiation-MHD) modeling is carried out to study the hydrodynamics and magnetic fields in the shock-shear derived platform. Here, simulations indicate that fields of tens of Tesla can be generated via the Biermann battery effect due to vortices and mix in the counterpropagating shock-induced shear layer. Synthetic proton radiography simulations using MPRAD and synthetic X-ray image simulations using SPECT3D are carried out to predict the observable features in the diagnostics. Quantifying the effects of magnetic fields in inertial confinement fusion and high-energy-density plasmas represents frontier research that has far-reaching implications in basic and applied sciences.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gold leaf phantom development for the assessment of proton radiographic sensitivity limits simulating gold nanoparticle tagged tumors

Proton radiography may guide proton therapy cancer treatments with beam’s-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high-Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high-Z, biologically compatible tracer, to differentiate tumors from surrounding tissue. We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.