Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Monte Carlo simulation analysis for radiation damage on Glidcop Al-15 caused by 17-20 MeV/u heavy ions

The Facility for Rare Isotope Beams (FRIB) SRF linear heavy-ion accelerator is designed to accelerate all ions up to uranium to a maximum beam power of 400 kW. Several beam intercepting devices (BIDs) are essential to the successful operation of the accelerator, including a low power charge selector (LPCS) made of copper containing 0.15% precipitated aluminum oxide by weight called Glidcop Al-15. As FRIB ramps up the primary beam power beyond the current 20 kW level, the charge selector must withstand higher radiation damage rates, typically measured in displacements per atom (dpa). Significant beam induced radiation damage including significant deformation, like swelling, blistering, and cracking has been observed on a recently removed LPCS. We also observed physical features up to about 5.5 mm wide and appear to be deeper than the projected range of any ions. This paper presents the results of Monte Carlo simulations carried out using the Particle and Heavy Ion Transport code System (PHITS), quantifying the total damage dose and ion concentration, etc. Simulating an accurate irradiation history is essential to determining the scope of post irradiation examination (PIE) work.

Fletcher, Ethan [Michigan State U.]↗

Challenges and Optimization of Mu2e Proton Target Design with Radiative Cooling

Mu2e, the Muon-to-Electron Conversion Experiment, aims to identify physics beyond the Standard Model, namely, the conversion of muons to electrons without the emission of neutrinos. The muons are produced from pions generated in a production target when it is hit by an 8 GeV proton beam from the Fermilab Booster/Main Injector. The proton target design space is strongly constrained by a one-year operating lifetime and the need for radiative cooling in a vacuum environment. Uncertainties in the lifetime of the existing baseline design – a monolithic, segmented tungsten target – are large, particularly due to unknown impacts of radiation damage at the very high proton fluences expected in the experiment. We have begun evaluation of a new design utilizing Inconel 718 over the WL10 used in the existing target design. As a result, the structural design of the target has evolved significantly. This evolution focuses on lowering the target temperature, minimizing obstruction to muons, increasing structural stability, maximizing fatigue lifetime, simplifying the fabrication process, and more. The thermal management, structural stability and fatigue lifetime are emphasized here. These optimizations have led to a promising new target design for the Mu2e experiment.

Liu, Z. [Fermilab]↗

Trends in Radiation Therapy for Bone Metastases, 2015 to 2017: Choosing Wisely in the Era of Complex Radiation

Guidelines recommend short-course (≤10 fractions) external-beam radiation therapy (EBRT) for bone metastases. Stereotactic body radiation therapy (SBRT) may also improve outcomes; however, routine use is not recommended outside clinical trials. We assessed national radiation therapy trends in complex techniques for bone metastases and associated expenditures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ethical, legal and social implications of human genome studies in radiation research: a workshop report for studies on atomic bomb survivors at the Radiation Effects Research Foundation

The Radiation Effects Research Foundation (RERF) is the primary organization in Japan dedicated to studying the health consequences of the Hiroshima and Nagasaki atomic bombings in World War II. In December 2020, RERF held a virtual international workshop on the ethical, legal and social implications (ELSI) of genome studies. In this workshop, the ELSI considerations of future human genome studies on radiation research including atomic bomb survivors and their families were discussed. Since genome sequencing (GS) is now practical and affordable, RERF now plans GS of parents/child trios to examine genetic effects of atomic bomb radiation. As such studies may engender some novel risks and benefits, ethics review and engagement with families (including consent) need to be considered. These include protection of individual privacy, use of samples from deceased prior participants, return of results to the participants, public sharing of genome data and advance science and social welfare. Specifically with regard to social welfare, the results of such studies may have implications for public and government decision-making regarding social benefits of victims and other important questions. Based on these broad-ranging discussions we have developed the following concepts to guide this work: “trust,” “compromise” and “relationship building,” inclusive of the concerned stakeholders, scientific aims and Japanese society at large. We conclude that in order to realize, establish and maintain these concepts, it is essential to put procedures into place to ensure the successful, consensus-based implementation of the RERF studies.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Health-Related Quality of Life Outcomes in Head and Neck Cancer: Results From a Prospective, Real-World Data Study With Brazilian Patients Treated With Intensity Modulated Radiation Therapy, Conformal and Conventional Radiation Techniques

To compare global health-related quality of life (HRQoL) and overall survival (OS) in patients with head and neck cancer treated with intensity modulated radiation therapy (IMRT), conformal radiation therapy (3DCRT) or conventional radiation therapy (2DRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Effectiveness Analysis of 3D-Conformal Radiation Therapy Versus Intensity Modulated Radiation Therapy (IMRT) in a Prospective Multicenter Cohort of Patients With Breast Cancer

Simple intensity modulation of radiation therapy reduces acute toxicity compared with 2-dimensional techniques in adjuvant breast cancer treatment, but it remains unknown whether more complex or inverse-planned intensity modulated radiation therapy (IMRT) offers an advantage over forward-planned, 3-dimensional conformal radiation therapy (3DCRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Common origin of warm dark matter and dark radiation

We consider a cosmological scenario where a relativistic particle and a stable massive particle are simultaneously produced from the decay of a late-decaying particle after Big-Bang Nucleosynthesis but before matter-radiation equality. The relativistic and massive particles behave as dark radiation and warm dark matter, respectively. Due to a common origin, the warmness and abundances are closely related. We refer to the models that lead to such a scenario as Common Origin of Warm and Relativistic Decay Products (COWaRD). We show that COWaRD predicts a correlation between the amount of dark radiation and suppression of the large scale structure, which can be tested in future precision cosmology observations. Furthermore, we demonstrate that COWaRD is realized, as an example, in a class of supersymmetric axion models and that future observations by the next generation Cosmic Microwave Background, Large Scale Structure, and 21-cm surveys can reveal the structure of the theory.

cosmology of theories beyond the SM↗

Dose-Response Relationship in Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma: A Pooled Analysis of an Asian Liver Radiation Therapy Group Study

Despite the worldwide implementation of stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma (HCC), there is a lack of consensus guideline on prescription dose. Herein, this multinational study aimed to investigate the effects of the prescribed radiation dose on oncologic outcomes of SBRT for HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pain Response After Stereotactic Body Radiation Therapy Versus Conventional Radiation Therapy in Patients With Bone Metastases—A Phase 2 Randomized Controlled Trial Within a Prospective Cohort

Pain response after conventional external beam radiation therapy (cRT) in patients with painful bone metastases is observed in 60% to 70% of patients. The aim of the VERTICAL trial was to investigate whether stereotactic body radiation therapy (SBRT) improves pain response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Source Localization Using Surrogate Models Constructed from 3-D Monte Carlo Transport Physics Simulations

Recent research has focused on the development of surrogate models for radiation source localization in a simulated urban domain. We employ the Monte Carlo N-Particle (MCNP) code to provide high- delity simulations of radiation transport within an urban domain. The model is constructed to employ a source location (x, y, z) as input and return the estimated count rate for a set of speci ed detector locations. Because MCNP simulations are computationally expensive, we develop e cient and accurate surrogate models of the detector responses. We construct surrogate models using Gaussian processes (GP) and neural networks (NN) that we train and verify using the MCNP simulations. The trained surrogate models provide an e cient framework for Bayesian inference and experimental design. We employ Delayed Rejection Adaptive Metropolis (DRAM), a Markov Chain Monte Carlo (MCMC) algorithm, to infer the location and intensity of an unknown source. The DRAM results yield a posterior probability distribution for the source's location conditioned on the observed detector count rates. The posterior distribution exhibits regions of high and low probability within the simulated environment identifying potential source locations. In this manner, we can quantify the source location to within at least one of these regions of high probability in the considered cases. Employing these methods, we are able to reduce the space of potential source locations by at least 60%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Shielding Analysis of Linac Extension Area in APS Using FLUKA and PHITS Monte Carlo Radiation Transport Codes

The Linac extension area tunnel can accept 300- to 500-MeV electrons for experiments. Radiations from various normal and accident beam loss scenarios were analyzed with the FLUKA and PHITS Monte Carlo radiation transport codes. In normal beam loss scenarios, the beam was dumped on the horizontal and vertical beam dumps, while the accident scenarios were horizontal and vertical mis-steered beams that can occur due to incorrect beam energy and magnet settings. The extent of beam deviation, which was established using particle tracking studies, was used to define the beam directions in the Monte Carlo transport calculations. Further, a mis-steered condition, where the beam was not intercepted by the dumps, was also analyzed. For the horizontal dump, the PHITS results above the berm were higher for neutrons and somewhat lower for photons, compared to the FLUKA results. Comparison of the secondary particle yields from FLUKA and PHITS from an Al block with dimensions comparable to what was used in the beam dumps showed a 40% higher neutron yield and a 10% lower photon yield. Finally, to ensure compliance with Argonne National Laboratory's shielding policy, the design of the horizontal beam dump was modified, and additional shielding was recommended.

FLUKA↗

Effects of Radiation-Induced Defects on Corrosion

The next generation of nuclear reactors will expose materials to conditions that, in some cases, are even more extreme than those in current fission reactors, inevitably leading to new materials science challenges. Radiation-induced damage and corrosion are two key phenomena that must be understood both independently and synergistically, but their interactions are often convoluted. In the light water reactor community, a tremendous amount of work has been done to illuminate irradiation-corrosion effects, and similar efforts are under way for heavy liquid metal and molten salt environments. While certain effects, such as radiolysis and irradiation-assisted stress corrosion cracking, are reasonably well established, the basic science of how irradiation-induced defects in the base material and the corrosion layer influence the corrosion process still presents many unanswered questions. In this review, we summarize the work that has been done to understand these coupled extremes, highlight the complex nature of this problem, and identify key knowledge gaps.

36 MATERIALS SCIENCE↗

Radiation Transport Simulation of the Sulfur Counting System in the Radiation Metrology Laboratory (RML)

At the request of staff members from the Radiation Metrology Laboratory (RML), a series of Monte Carlo radiation transport calculations were performed using two different models of the detector geometry of the RMLs sulfur counting system. The fraction of electrons from each β-decay of 32 P in the sulfur pellet that enter the window of the sulfur counting system was calculated with both MCNP and ITS. In addition, the differential energy distributions of the electrons entering the counting system window were computed. There was significant agreement between the integral and differential quantities calculated by the two transport codes. Summary tables are for the integral efficiency values are found in the body of the report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update of Radiation References: Results from the WMO Expert Team on Radiation References

Primary metrological references for solar (shortwave) & terrestrial (longwave) radiation are instrument-based, managed by PMOD/WRC. New references (new instruments) have been proposed with improved traceability to SI. However, comparisons show bias between the old and new references. ET-RR should advise WMO whether and how to proceed with the change in radiation references without disrupting climate (and meteorological) science.

ACP↗