Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation detection systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Developing an intrinsically secure information barrier for arms control verification through machine learning

Near-term solutions are needed to allow for flexible engagement in future nuclear arms control discussions. This project developed a method for implementing an information barrier (IB) on commercial systems, shortening the research and development lifecycle for warhead verification technologies while offering improved and inherently flexible capabilities. The crux of the verification challenge remains the difficulty in developing an authenticatable IB which prevents sensitive host country information from inadvertent transmission to an inspector. Many concepts for IB’s rely on dedicated “trusted” processor modules developed with dedicated custom radiation detection systems and associated algorithms. Without a priori knowledge of the treaty item, the parameter space for measurements can be nearly infinite and robustness against spoofing without the ability to view sensitive data is key. This project has produced an unclassified framework capable of ingesting data from common gamma detectors and identifying the presence of weapons grade nuclear material at over 90% accuracy.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Hands-On, Heads-Up: Blending Cyber T&E with Data Science-Driven Training in Jupyter Notebooks

In an era of increasingly sophisticated threats to critical infrastructure, cybersecurity professionals must be more than just aware; they must be immersed, agile, and equipped to operate in environments where failure is not an option. Nowhere is this truer than in the nuclear sector, where cyber-physical systems, regulatory scrutiny, and insider threat potential demand a new generation of hands-on, technically fluent defenders. This paper presents a unified training approach that integrates Cybersecurity Test and Evaluation (T&E) with data science techniques using Jupyter Notebooks as the interactive lab environment. The program centers on a modular, scenario-driven curriculum designed to build not just knowledge but practical capability in the assessment and defense of radiation detection systems, firmware interfaces, and operational security postures.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Critical thermonuclear reactions in classical novae and type I X-ray bursts

The goal of this project was to experimentally constrain the nuclear reaction rates whose uncertainties have the largest impact on models of classical novae and Type-I X-ray bursts. These astrophysical events occur when a white dwarf or neutron star, respectively, accretes hydrogen and helium from a companion star until a thermonuclear runaway ensues. The primary reactions of interest to this project for novae and X-ray bursts are 30 P(ρ,γ) 31 S and 15 O(α,γ) 19 Ne. The project methodology was to develop a new radiation detection system in two phases to measure the low-energy beta-delayed particle emissions of 31 Cl and 20 Mg at the National Superconducting Cyclotron Laboratory (NSCL) in order to constrain these two reaction rates. In particular, a gas-filled charged-particle detector was to be designed, constructed and operated, in concert with the SeGA array.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impurity-enhanced core valence luminescence via Zn-doping in cesium magnesium chlorides

Scintillators with faster timing capabilities are currently in high demand for use in radiation detection systems in the fields of nuclear and medical physics. The limited number of suitable materials that meet the performance criteria of next generation detection systems presents an opportunity for discovery of new fast scintillator materials. In this work, the effects of doping several ultrafast core-valence luminescent (CVL) scintillators with divalent Zn is explored. Three compounds are investigated – CsMgCl 3 , Cs 2 MgCl 4 , and Cs 3 MgCl 5 – and single crystals of each doped with 5 mol% Zn are grown via the Bridgman method. Additionally, mixing across the full range of concentrations (from 0 % to 100 % Zn) is explored in the Cs 2 Mg 1-x Zn x Cl 4 and Cs 3 Mg 1-x Zn x Cl 5 systems. For low concentrations of Zn, light yields of all three compounds are enhanced (by up to ~60 %) compared to the pure crystals, achieving what we believe to be the brightest known CVL, CsMgCl 3 :Zn 5 % (3400 ± 170 ph/MeV light yield). More importantly, Zn doping does not affect the ultrafast timing properties, with each composition maintaining a single-component decay time around 1–3 ns. A sub-100 ps coincidence time resolution (CTR) is also achieved with CsMgCl 3 :Zn 5 %. The results of this work reveal a new avenue towards obtaining brighter CVL materials, which could open up possibilities for more advanced ultrafast scintillators to be discovered moving forward.

36 MATERIALS SCIENCE↗

Characterization of retroreflective tape optical properties for use with position-sensitive scintillator detectors

Reflective materials such as Teflon and Enhanced Specular Reflector are commonly used to maximize light collection in scintillator-based radiation detection systems. While effective, in most cases, the spatial information carried by the light is diminished or lost entirely. Retroreflectors, in contrast, better preserve the spatial information and have been shown to improve the localization performance of such systems. In this work, the relative retroreflectivity of a selection of commercial retroreflective tapes and their performance impact when coupled to a plastic scintillator are reported. Finally, we demonstrate improved localization performance with some tapes compared to Teflon and black paint.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer

Here we present 4:1 multiplexing of organic scintillators, each coupled to a silicon photomultiplier (SiPM), to reduce the need for a large number of digitizer input channels to readout highly pixelated radiation detection systems. Frequency domain multiplexing (FDM) encodes a detector pulse by assigning it a unique frequency via convolution before combining the encoded signal into a single channel. The combined signal is then read through a digitizer input channel. We have designed an FDM system to multiplex four SiPMs using DRS4 digitizer evaluation board from Paul Scherrer Institute (PSI). We demonstrate 4:1 multiplexing of the SiPM fast output signals and pulse recovery from the digitized multiplexed signal using deconvolution. The noise in the recovered pulse introduces a bias and uncertainty in the estimate of energy and timing that changes with pulse height. The relative uncertainty in the estimated energy from the recovered pulse decreases with pulse height with a maximum uncertainty of 3.1% for the low energy pulses (corresponding to 100 keV); the uncertainty in the estimated time pick-off also decreases with pulse height with a maximum uncertainty of 110 ps for the low energy pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fixed-Energy Response-Function Analysis with Multi-Efficiency (FRAM) Software, Version 6

Researchers at Los Alamos National Laboratory have developed FixedEnergy Response- Function Analysis with Multiple Efficiency (FRAM), a powerful software tool for gamma-ray spectrometry isotopic analysis. This tool leverages Los Alamos expertise in nuclear safeguards, radiation detection systems, and related analysis techniques. A household name in the non-destructive assay community for over two decades, FRAM determines a special nuclear material source's isotopic composition by analyzing gamma-ray spectra. Los Alamos researchers have released the latest version of FRAM that incorporates several updates to the 2013 major release of FRAM, Version 5.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation Signature Training Device Gamma Equivalent Spheres

Radiation signature training device sources are a continuation of a previous effort to produce a highly enriched uranium equivalent sphere. The original research was designed and motivated to produce a Department of Transportation special form source that emulated the passive gamma signature of a solid metal highly enriched uranium sphere. In addition, the mass reduction (i.e., of the 235 U) minimized logistical costs (security, criticality safety, radiological safety and transportation requirements). Radiation signature training device sources expand on the original concept, redesigning the encapsulation in a modular fashion that allows a variety of loadings. The result is a reconfigurable special nuclear material source set that can vary greatly in the magnitude of the gamma flux and the isotopic distribution. Use of the source to test a variety of standards (N42.34-2015, N42.38-2015, N42.43-2015, N42.53-2018, N42.48-2018, DHS-TCS Backpack Based Radiation Detection Systems, DHS-TCS Handheld Instruments Used for the Detection and Identification of Radionuclides, DHS-TCS Vehicle Mounted Mobile Systems) will be discussed.

Blessinger, Christopher S.↗

Operational Focused Data Analytics for Optimizing Radiation Portal Monitor-Based Nuclear Smuggling Detection Systems at Global Ports of Entry

The National Nuclear Security Administration’s Office of Nuclear Smuggling Detection and Deterrence has deployed a fleet of radiation portal monitors (RPMs) across the world at global ports of entry including seaports, airports, and land border crossings. These RPMs are integrated into radiation detection systems (RDS) that also include fixed cameras, optical character recognition (OCR) systems, primary scanning systems (e.g., X-ray or gamma-ray), and secondary scanning systems (e.g., spectroscopic radiation portal monitors, portable radiation detection systems). The data from these sensing technologies is collected at the Central Alarm Station (CAS) where servers and computers reside to control and operate the system. Operators utilize the data collected by the CAS and declared cargo information to make decisions on how to respond to an alarm.This work explores the use of CAS-located data, looking at both the sensor data streams and operator inputs, to perform analysis which supports customs and border protection agencies to improve training capability and operational effectiveness. We focus on analyzing site level effectiveness and behavior by rolling up CAS-located data collected from individual occurrences. To-date, more than 15 sites (e.g., seaports, airports, border crossings) have been analyzed in this manner with the goal of understanding system operations to verify effectiveness and recommend potential improvements. This work first aims to provide background information on relevant CAS-located data sources and our current operational system analytics process including example results. After summarizing our current analytic techniques, we discuss how the future data analytics systems can provide key benefits to improving operational performance while minimizing the burden these detection systems place on operators.

Kuhn, Michael↗

On the detection of other planetary systems - Detection of intrinsic thermal radiation

There is currently no unambiguous observational evidence for the existence of other planetary systems. One possible way to detect and study such systems is infrared observations of continuum blackbody radiation from planets revolving around other stars. It is shown that the effective temperature of large planets revolving around mid- to late-spectral-type main-sequences stars is set by energy sources internal to the planet rather than by equilibrium with the radiation field of the central star, making them easier to detect than had been previously thought. Consideration is given to the two major observational constraints on detecting planetary companions to nearby stars, namely, angular resolution and sensitivity. A comparison is made between the performance of an ambient (T 200 K), single-aperture telescope and a cooled interferometer. In each case the required aperture (baseline) is large (in the 10-m class), but consistent with Shuttle launch capability.

Black, D. C.↗

MRDIS Case Study

The Mobile Radiation Detection and Identification System (MRDIS) is a large mobile scanner that inspects containers in transit from cargo ships for radiological materials. The MRDIS platform operates as a two-part system with one MRDIS using a plastic Polyvinyl Toleune (synthetic polymer) for primary detection and another MRDIS that uses spectroscopic detectors for secondary isotopic identification. MRDIS can operate either independently or as part of a team, depending on the needs of the port. MRDIS is controlled by a human operator, who searches the computer monitor for any traces of radiological materials when the containers pass through the center of the system. Each MRDIS can also feed data into a central system or collect data on its own for additional material analysis. The system integrates radiation detection, radioisotope identification, an optical character recognition system, occupancy/speed sensors, wireless communications, and data processing capabilities to discern what specific radiological materials are of particular interest. In addition, Sandia engineers created a detailed set of requirements for subsequent models, allowing for faster implementation of additional detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lightning mapping system

A Lightning Detection and Ranging (LDAR) System is being implemented at KSC in Florida. The first operational use is expected in the late summer of 1991. The system is designed to map the location of in-cloud and cloud-to-ground lightning based on the time of arrival (TOA) of electromagnetic radiation. The system detects very high frequency (VHF) radiation and designed to map the volumetric extent of lightning. The system implements two independent antenna arrays to provide a fast data quality check, as necessary for a real-time warning system. The system performance goals and a comparison with a similar system implemented in the mid-1970's is made.

Lennon, C.↗

Multilateral Testing Workshop on Relocatable Portal Monitors

The procurement and deployment of radiation detection equipment is a multi-faceted challenge across the globe. Knowledge sharing of the testing methods used to evaluate equipment for deployment scenarios helps improve the understanding of deployed systems by the global community. The United States Department of Energy’s Nuclear Smuggling Detection and Deterrence Office (NSDD) performed a series of characterization measurements in 2019, focused on radiation detection systems that could function as relocatable portal monitors. The capstone activity for this project was a multilateral and cross-disciplinary workshop demonstrating, performing, and refining the techniques used in the characterization measurements with International Atomic Energy Agency (IAEA) and global partners. A group of technical experts including representatives from nine countries, the IAEA, and NSDD gathered at Sandia National Laboratories in Albuquerque, NM during September of 2019 for the Operational and Performance Testing and Evaluation of Relocatable Portals Workshop. Over the course of a week, the group discussed the necessity for and process of developing operational and performance requirements, challenges related to deploying radiation detection systems for the countries in attendance, use cases for deploying relocatable radiation detection equipment, and considerations related to testing equipment for appropriate deployment scenarios. All participants were given the opportunity to have hands-on experience with eleven relocatable systems in executing a limited scope characterization test comprised of six test scenarios. At the conclusion of testing, participants reviewed and presented their findings, and the group as a whole compared and contrasted their experiences. Suggested revisions to the test methods and ideas for further collaborations were discussed. This report discusses the logistical and planning considerations for bringing together experts across disciplines in a multilateral workshop on testing of radiation detectors, as well as presenting the testing methods performed, results, and paths forward. Success of workshops related to technical knowledge transfer and improvement of test methods is key to global technical and scientific support of radiation detection deployments.

Erchinger, Jennifer L.↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗