Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum cascade lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Laser absorption measurements of temperature, pressure, CO, and CO 2 at near-MHz rates in post-detonation fireballs with comparison to synthetic measurements

A laser absorption spectroscopy (LAS) diagnostic was used to obtain measurements of temperature, pressure, CO, and CO 2 at 500 kHz or 1 MHz in post-detonation fireballs produced by hemispherical samples of pentaerythritol tetranitrate (PETN). A quantum-cascade laser was scanned over multiple CO absorption transitions near 2008.5 cm −1 at 1 MHz, while an interband-cascade laser was scanned over a CO 2 absorption transition near 2394.8 cm −1 at 500 kHz. Light from each laser was combined onto a single path and passed through a detonation chamber approximately 83 mm above the 12-mm diameter hemispherical PETN charge. The CO and CO 2 absorption signals were post-processed to obtain time histories of temperature, pressure, species column pressures (P CO L, P CO2 L), and species column mole fractions (X CO L, X CO2 L). Additionally, schlieren imaging was performed simultaneously at 500 kHz to aid interpretation of the LAS measurements. Experimental and synthetic (i.e., CFD based) LAS measurements were compared to evaluate the accuracy of the CFD model and its ability to model the turbulent afterburning of the detonation products in air. In general, the experimental measurements exhibit reasonable agreement with the synthetic measurements at early times; thereby supporting the accuracy of the CFD model. Periods of disagreement between experimental and synthetic measurements at later times are most likely due to a reflected shock and detonator cavity jetting, which are not accounted for in the CFD model.

Schwartz, Charles J. [Purdue Univ., West Lafayette↗

Precision ultranarrow-linewidth resonance excitation (PURE) preparation of a molecular beam of nitric oxide molecules for inelastic scattering with argon

We recently reported a novel technique that utilizes narrow-linewidth lasers to selectively excite molecules into a pure quantum state with a well-resolved, tunable distribution of velocities [O. A. Krohn and D. W. Chandler, J. Phys. Chem. Lett. 15(50), 12455–12463 (2024)]. We refer to the preparation of molecules by this technique as precision ultranarrow-linewidth resonant excitation (PURE) preparation. Here, in this study, we pair this PURE preparation methodology with active frequency stabilization of the quantum cascade laser that drives the excitation. In doing so, highly velocity-resolved packets of molecules are possible, with the limitations of this velocity resolution set by the stability of the laser locking and the spectral linewidth of the transition. We show that side-of-fringe locking to a Doppler-broadened absorption spectrum of our target molecule is sufficiently stable for PURE preparation of molecules for long timescales (several hours) with highly resolved velocity spreads (σ < 3 m/s). To demonstrate the scientific utility of this new capability, we present differential cross sections from scattering between a neat molecular beam of argon and a velocity-selected beam of nitric oxide (NO) in a pure quantum state. We observe well-resolved quantum diffraction oscillations in the forward-scattered collisions as well as general trends consistent with prior characterized collisions of NO + Ar.

Krohn, Olivia A. [Sandia National Laboratories (SN↗

Bound and Continuum Intersubband Transitions in Colloidal Quantum Wells

Quantum well intersubband transitions are critical for quantum cascade lasers and infrared photodetectors. Control of band offsets allows bound-to-bound intersubband transitions, with confinement of both initial and final states, and bound-to-continuum transitions, in which only the initial state is energetically confined within the potential well. Both types of transitions are also achieved in colloidal CdSe wells by changing the heterostructure shell. Bare wells have narrow intersubband transitions spanning the near-infrared spectrum following effective mass predictions. Atomically precise core/shells enable a readily adjusted potential well for electrons. For CdSe/ZnS, bound-to-bound transitions are narrow and redshift with shell thickness. By contrast, broad bound-to-continuum absorptions are found in CdSe/CdS. Due to small conduction band offsets, higher conduction band states of the well are more delocalized into the CdS shell. In conclusion, these measurements provide unique data to understand the electronic structure of colloidal quantum wells and chart a path to atomically precise optoelectronic materials for the mid-infrared.

colloidal atomic layer deposition↗

Time-resolved CO 2 , CO, and N 2 vibrational population measurements in Ns pulse discharge plasmas

Abstract Time-resolved CO 2 and N 2 vibrational populations and translational-rotational temperature are measured in a CO 2 –N 2 plasma sustained by a ns pulse discharge burst in plane-to-plane geometry. Time-resolved, absolute number density of CO generated in the plasma is also inferred from the experimental data. CO 2 and CO vibrational populations are measured by mid-IR, tunable quantum cascade laser absorption spectroscopy, and N 2 vibrational populations are measured by the ns broadband vibrational CARS. Transient excitation of N 2 and CO 2 asymmetric stretch vibrational energy modes is detected during the discharge burst. The time-resolved rate of CO generation does not correlate with N 2 or CO 2 ( ν 3 ) vibrational temperatures, indicating that CO 2 dissociation via the vibrational excitation is insignificant at the present conditions. The rate of CO generation decreases gradually during the discharge burst. The estimated specific energy cost of the CO product is close to that of N atoms in pure nitrogen, measured previously at similar operating conditions. Comparison of the experimental data with the kinetic modeling analysis indicates that CO 2 dissociation in collisions with electronically excited N 2 molecules is the dominant channel of CO generation at the present conditions, although the inferred CO yield in these processes is significantly lower than 1. The effect of vibrational energy transfer between N 2 and CO 2 on the plasma chemical processes is insignificant. The kinetic model underpredicts a rapid reduction of the N 2 and CO 2 ( ν 3 ) vibrational temperatures during the later half of the discharge burst and in the afterglow. V–T relaxation of N 2 by N and O atoms generated in the ns pulse discharge plasma does not affect the vibrational relaxation rate in a significant way. However, rapid V–T relaxation of CO 2 by O atoms has a significant effect on the relaxation rate. The difference between the experimental data and the modeling predictions may be due to the unknown scaling of the CO 2 –O V–T rates with the vibrational quantum number.

Physics↗

Shock tube investigation of high-temperature, extremely-rich oxidation of several co-optima biofuels for spark-ignition engines

To reduce the reliance on fossil fuels in the transportation sector and increase combustion efficiency, the Co-Optima initiative from US Department of Energy identified the top 10 biofuels for downsized, boosted, spark-ignition engines. Most of these biofuels have detailed reaction mechanisms available in literature developed based on studies at temperatures lower than 1700 K and an equivalence ratio of less than five. As such, the performance of these detailed mechanisms at high temperature and extremely rich conditions are unknown. It is important to validate kinetic mechanisms at these conditions because they are conducive to soot formation. Prediction of soot by chemical kinetic models relies on the prediction of underlying benchmark species like carbon monoxide and ethylene. In this work, we conduct high temperature (1700–2050 K) and high equivalence ratio(Φ=8.6) oxidation of these biofuels, namely 2,4,4-trimethyl-1-pentene (α-diisobutylene), ethanol, cyclopentanone, methyl acetate, and 2-methylfuran, blended in ethylene behind reflected shock waves at 4–4.7 atm pressure. Carbon monoxide and ethylene time histories are measured simultaneously using a continuous feedback quantum cascade laser near 4.9 µm and a tunable CO 2 gas laser at 10.532 nm, respectively. Results show that ethanol blend forms more carbon monoxide than other biofuels and consumes ethylene faster than the biofuel blends in the temperature range considered. Overall, the performance of different mechanisms in literature are evaluated against the experimental results. The novel reaction mechanism ‘the Co-Optima model’, which includes the sub mechanisms for all the biofuels in this study, was found to be the best mechanism for the experimental conditions studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design study of a combined interferometer and polarimeter for a high-field, compact tokamak

This article is the first design study of a combined interferometer and polarimeter on a compact, high-field, high-density, net-energy tokamak. Recent advances in superconducting technology have made possible designs for compact, high magnetic field fusion power plants, such as ARC [Sorbom et al., Fusion Eng. Des. 100, 378 (2015)], and experiments, such as SPARC [Greenwald et al., PSFC Report No. RR-18-2 (2018)]. These new designs create both challenges and opportunities for plasma diagnostics. The diagnostic proposed in this work, called InterPol, takes advantage of unique opportunities provided by high magnetic field and density to measure both line-averaged density and poloidal magnetic field with a single set of CO 2 and quantum cascade lasers. These measurements will be used for fast density feedback control, constraint of density and safety factor profiles, and density fluctuation measurements. Synthetic diagnostic testing using a model machine geometry, called MQ1 (Mission Q ≥ 1), and profiles simulated with Tokamak Simulation Code indicate that InterPol will be able to measure steady state density and poloidal magnetic field, as well as fluctuations caused by toroidal Alfven eigenmodes and other phenomena on a high-field compact tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-color, intracavity pump–probe, cavity ringdown spectroscopy

Here, we report a proof-of-principle demonstration of intracavity pump–probe, cavity ringdown (CRD) detection in a three-mirror, traveling-wave cavity. With cavity-enhanced pump power and probe absorption path length, the technique is a generally applicable, high-sensitivity, high-selectivity detection method. In our experiments, the pump radiation is switched off during every other probe ringdown, which allows uncorrelated measurements of analyte and background cavity decay rates. The net, two-color signal from the difference between the pump-on and pump-off decay rates is immune to empty-CRD drifts and spectral overlaps from non-target molecular transitions. The immunity to the ringdown drifts allows longer signal-averaging and, thus, higher detection sensitivity. The ability to compensate for the background absorption enhances the detection selectivity in spectrally congested regions. Our technique is well-suited for trace-detection in the mid-IR region, where pump–probe schemes based on strong rovibrational transitions can be applied. In this work, two-color CRD detection is implemented on a ladder-type, three-level system based on the N 2 O, ν 3 = 1 ← 0, P(19) (pump) and ν 3 = 2 ← 1, R(18) (probe), rovibrational transitions. By frequency-locking two-quantum cascade lasers to the p-polarization (pump, Finesse = 5280) and s-polarization (probe, Finesse = 67 700) cavity modes, we achieve high intracavity pump power (36 W) and high probe ringdown rates (>2 kHz). The observed two-color spectra are simulated by a density-matrix, three-level system model that is solved under the constraints of the cavity resonance conditions. In addition to its background compensation capability, experimental flexibility in the selection of pump–probe schemes and signal insensitivity to intracavity laser power are further features that enhance the utility of our technique for mid-IR trace-detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thin THz QCL active regions for improved continuous-wave operating temperature

We compare the performance of 10 and 5 μm thick metal–metal waveguide terahertz quantum-cascade laser ridges operating around 2.7 THz and based on a 4-well phonon depopulation active region design. Thanks to reduced heat dissipation and lower thermal resistance, the 5 μm thick material shows an 18 K increase in continuous wave operating temperature compared to the 10 μm material, despite a lower maximum pulsed-mode operating temperature and a larger input power density. A maximum continuous wave operating temperature of 129 K is achieved using the 5 μm thick material and a 15 μm wide ridge waveguide, which lased up to 155 K in the pulsed mode. The use of thin active regions is likely to become increasingly important to address the increasing input power density of emerging 2- and 3-well active region designs that show the highest pulsed operating temperatures.

47 OTHER INSTRUMENTATION↗

A Tunable Unidirectional Source for GUSTO's Local Oscillator at 4.74 THz

The Galactic/Extra Ultra long Duration Balloon Spectroscopic-Stratospheric Terahertz Observatory (GUSTO), is a NASA balloon-borne project and is scheduled for launch in late 2022. The balloon will carry a spectroscopic telescope that will detect three brightest emission lines from interstellar medium. GUSTO measurements will shed light on the life-cycle of the gases in the Milky Way and Large Magellanic Cloud (LMC). In this study, we will discuss the details of a quantum cascade laser used in the local oscillator for detecting the oxygen line at 4.74 THz.

42 ENGINEERING↗

Infrared spectroscopic method for uranium isotopic analysis

A high performance infrared (HPIR) system was developed and demonstrated for the infrared absorption analysis of {sup 235}U and {sup 238}U isotopes in uranium hexafluoride gas samples. Sweeping the quantum cascade laser light source over the spectral range and sampling via a high-rate analog-to-digital converter provided 0.0005 cm-1 spectral resolution, which allowed for high-precision measurements of the isotopic peak shift. A data analysis method was developed using principal component analysis to predict the isotope weight % content of {sup 235}U. The HPIR precision, accuracy, and error were evaluated for a wide range of isotopic ratio samples (0.287 – 93.7 weight % {sup 235}U), and the results were compared to the International Target Values (ITVS) set forth by the International Atomic Energy Agency (IAEA) for non-destructive and destructive analytical techniques. The method meets or surpasses the IAEA ITVs for non-destructive analysis of samples with isotopic content of depleted to highly enriched. The results also demonstrated the capability of the HPIR system to correctly predict the {sup 235}U weight % content of a mislabeled sample whose isotopic distribution was validated by mass spectroscopic measurements. The HPIR measurement is nondestructive and, thus, allows for confirmatory analyses of the exact sample at a designated IAEA lab if higher-resolution or a certified analysis is needed. (author)

07 ISOTOPE AND RADIATION SOURCES↗

Fundamental bandwidth limits and shaping of frequency-modulated combs

Frequency-modulated (FM) combs based on active cavities like quantum cascade lasers have recently emerged as promising light sources in many spectral regions. Unlike passive modelocking, which generates amplitude modulation using the field’s amplitude, FM comb formation relies on the generation of phase modulation from the field’s phase. They can therefore be regarded as a phase-domain version of passive modelocking. However, while the ultimate scaling laws of passive modelocking have long been known—Haus showed in 1975 that pulses modelocked by a fast saturable absorber have a bandwidth proportional to effective gain bandwidth—the limits of FM combs have been much less clear. Here, we show that FM combs based on fast gain media are governed by the same fundamental limits, producing combs whose bandwidths are linear in the effective gain bandwidth. Not only do we show theoretically that the diffusive effect of gain curvature limits comb bandwidth, but we also show experimentally how this limit can be increased. By adding carefully designed resonant-loss structures that are evanescently coupled to the cavity of a terahertz laser, we reduce the curvature and increase the effective gain bandwidth of the laser, demonstrating bandwidth enhancement. Our results can better enable the creation of active chip-scale combs and be applied to a wide array of cavity geometries.

47 OTHER INSTRUMENTATION↗

Infrared Absorption Spectra of H2SO4, SO3, SO2, and H2O at 300C and 350C

Mid infrared absorption spectra of sulfuric acid (H2SO4), sulfur trioxide (SO3), sulfur dioxide (SO2), and water (H2O) were collected in a high temperature gas cell operating at either 300C or 350C. The spectra were collected using tunable external cavity quantum cascade lasers (ECQCLs) tuning, which were capable of operating over the wavelength range from approximately 7 microns to 9 microns, where H2SO4 and SO3 have their strongest absorption features. The spectra can be used as a library for developing gas sensors.

infrared absorption↗

Delay-resolved spectroscopy in terahertz photonic circuits

Photonic integrated circuits incorporating intersubband transitions are ideal for mid-infrared and terahertz nanophotonics. However, the design of epitaxies has long been inhibited by two factors: the modest predictivity of ab initio theory and the absence of absolute intersubband gain and loss measurements under operating conditions. Existing measurements either yield inaccurate gain profiles or do not accurately assess dependence on frequency, bias, and temperature. Here, we present a delay-resolved absolute-referencing method for accurate gain evaluation without these limitations, addressing a long-standing challenge. By creating a photonic circuit that allows broadband pulses to traverse different lengths of a gain medium, we measure the absolute transmission of intersubband structures. Gain profiles match theoretical predictions at lower temperatures, with gain and dispersion clamping after lasing, and faster-than-expected degradation occurs at higher temperatures. Our approach provides a precise experimental evaluation of temperature-dependent gain performance and gives insight into optimizing temperature performance and frequency comb designs.

Optical spectroscopy↗

Coupling Pulse Radiolysis with Nanosecond Time-Resolved Step-Scan Fourier Transform Infrared Spectroscopy: Broadband Mid-Infrared Detection of Radiolytically Generated Transients

We describe the first implementation of broadband, nanosecond time-resolved step-scan Fourier transform infrared (S 2 -FT-IR) spectroscopy at a pulse radiolysis facility. This new technique allows the rapid acquisition of nano- to microsecond time-resolved infrared (TRIR) spectra of transient species generated by pulse radiolysis of liquid samples at a pulsed electron accelerator. Wide regions of the mid-infrared can be probed in a single experiment, which often takes < 20–30 min to complete. It is therefore a powerful method for rapidly locating the IR absorptions of short-lived, radiation-induced species in solution, and for directly monitoring their subsequent reactions. Time-resolved step-scan FT-IR detection for pulse radiolysis thus complements our existing narrowband quantum cascade laser-based pulse radiolysis-TRIR detection system, which is more suitable for acquiring single-shot kinetics and narrowband TRIR spectra on small-volume samples and in strongly absorbing solvents, such as water. We have demonstrated the application of time-resolved step-scan FT-IR spectroscopy to pulse radiolysis by probing the metal carbonyl and organic carbonyl vibrations of the one-electron-reduced forms of two Re-based CO 2 reduction catalysts in acetonitrile solution. Transient IR absorption bands with amplitudes on the order of 1 × 10 −3 are easily detected on the sub-microsecond timescale using electron pulses as short as 250 ns.

(S2-FT-IR)↗

Phase Locking of a THz QC-VECSEL to a Microwave Reference

We report high-resolution frequency study and phase locking have been performed on a terahertz (THz) quantum-cascade vertical-external-cavity surface-emitting laser (QC-VECSEL) operating around 2.5 THz. A subharmonic diode mixer is used to down convert the THz signal to a 100 MHz intermediate frequency that is phase locked to a stable 100 MHz microwave reference. Between 90% and 95% of the QC-VECSEL signal is locked within 2 Hz of the multiplied RF reference, and amplitude fluctuations on the order of 1%–10% are observed, depending on the bias point of the QC-VECSEL. The bandwidth of the locking loop is ~1 MHz. Many noise peaks in the IF signal are observed, likely corresponding to mechanical resonances in the 10 Hz–10 kHz. These peaks are generally -30 to -60 dB below the main tone and are below the phase noise level of the multiplied RF reference that ultimately limits the phase noise of the locked QC-VECSEL.

42 ENGINEERING↗