Engineering PapersSearch

SEARCH · Engineering Papers

Results for “quality factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Quality Factor and Microslipping of Fatigue Cracks in Thin Plates at Resonant Vibration

Resonant vibrations have been stimulated in thin metal plates using a non-contacting electromagnetic driver. A sinusoidal force was applied in a swept frequency fashion and the resulting surface displacements were monitored through the use of an acoustic microphone. It has been found that the presence of a fatigue crack in the sample causes a broadening of the second resonance peak. The Q factors of the resonance curves were determined and are directly correlated with the presence of fatigue cracks in the samples. The broadening of the curves is explained in terms of a microslipping at the crack face walls which reduces the amplitude of the resonant vibration by increasing the damping of the system. A comparison is made between the resonance characteristics of fatigue damaged and notched samples, where the stiffness of the two systems is nearly constant while the interaction between crack face walls is eliminated in the latter.

Wincheski, B.

Managing Lunar and Mars Mission Radiation Risks: Cancer Risks, Uncertainties, and Shielding Effectiveness - Part 1

This document addresses calculations of probability distribution functions (PDFs) representing uncertainties in projecting fatal cancer risk from galactic cosmic rays (GCR) and solar particle events (SPEs). PDFs are used to test the effectiveness of potential radiation shielding approaches. Monte-Carlo techniques are used to propagate uncertainties in risk coefficients determined from epidemiology data, dose and dose-rate reduction factors, quality factors, and physics models of radiation environments. Competing mortality risks and functional correlations in radiation quality factor uncertainties are treated in the calculations. The cancer risk uncertainty is about four-fold for lunar and Mars mission risk projections. For short-stay lunar missins (<180 d), SPEs present the most significant risk, but one effectively mitigated by shielding. For long-duration (>180 d) lunar or Mars missions, GCR risks may exceed radiation risk limits. While shielding materials are marginally effective in reducing GCR cancer risks because of the penetrating nature of GCR and secondary radiation produced in tissue by relativisitc particles, polyethylene or carbon composite shielding cannot be shown to significantly reduce risk compared to aluminum shielding. Therefore, improving our knowledge of space radiobiology to narrow uncertainties that lead to wide PDFs is the best approach to ensure radiation protection goals are met for space exploration.

Cucinotta, Francis A.

Evaluating Shielding Effectiveness for Reducing Space Radiation Cancer Risks

We discuss calculations of probability distribution functions (PDF) representing uncertainties in projecting fatal cancer risk from galactic cosmic rays (GCR) and solar particle events (SPE). The PDF s are used in significance tests of the effectiveness of potential radiation shielding approaches. Uncertainties in risk coefficients determined from epidemiology data, dose and dose-rate reduction factors, quality factors, and physics models of radiation environments are considered in models of cancer risk PDF s. Competing mortality risks and functional correlations in radiation quality factor uncertainties are treated in the calculations. We show that the cancer risk uncertainty, defined as the ratio of the 95% confidence level (CL) to the point estimate is about 4-fold for lunar and Mars mission risk projections. For short-stay lunar missions (<180 d), SPE s present the most significant risk, however one that is mitigated effectively by shielding, especially for carbon composites structures with high hydrogen content. In contrast, for long duration lunar (>180 d) or Mars missions, GCR risks may exceed radiation risk limits, with 95% CL s exceeding 10% fatal risk for males and females on a Mars mission. For reducing GCR cancer risks, shielding materials are marginally effective because of the penetrating nature of GCR and secondary radiation produced in tissue by relativistic particles. At the present time, polyethylene or carbon composite shielding can not be shown to significantly reduce risk compared to aluminum shielding based on a significance test that accounts for radiobiology uncertainties in GCR risk projection.

Cucinotta, Francis A.

A research review of quality assessment for software

Measures were recommended to assess the quality of software submitted to the AdaNet program. The quality factors that are important to software reuse are explored and methods of evaluating those factors are discussed. Quality factors important to software reuse are: correctness, reliability, verifiability, understandability, modifiability, and certifiability. Certifiability is included because the documentation of many factors about a software component such as its efficiency, portability, and development history, constitute a class for factors important to some users, not important at all to other, and impossible for AdaNet to distinguish between a priori. The quality factors may be assessed in different ways. There are a few quantitative measures which have been shown to indicate software quality. However, it is believed that there exists many factors that indicate quality and have not been empirically validated due to their subjective nature. These subjective factors are characterized by the way in which they support the software engineering principles of abstraction, information hiding, modularity, localization, confirmability, uniformity, and completeness.

Source record

Training, Quality Assurance Factors, and Tools Investigation: a Work Report and Suggestions on Software Quality Assurance

Previously, several research tasks have been conducted, some observations were obtained, and several possible suggestions have been contemplated involving software quality assurance engineering at NASA Johnson. These research tasks are briefly described. Also, a brief discussion is given on the role of software quality assurance in software engineering along with some observations and suggestions. A brief discussion on a training program for software quality assurance engineers is provided. A list of assurance factors as well as quality factors are also included. Finally, a process model which can be used for searching and collecting software quality assurance tools is presented.

Lee, Pen-Nan

Microdosimetry and the radiation danger of cosmic rays

The radiation danger of space flights is due primarily to intensive proton fluxes accompanying solar flares and heavy multiple charged ions in galactic cosmic radiation. Evaluation of the biological effect of these kinds of rays is based on calculations of tissue dose, taking into account the formation of secondary radiation in shielding and tissue. The essential role in such calculations is played by the dependence of the factor of quality on linear energy transfer (LET) of these charged particles. Recommendations concerning the dependence of the quality factor on LET are based on radiobiological experiments carried out on many biological systems using various kinds of rays, including heavy ions with energies in the 1-10 Mev/nucleon range. Justification of the results of these experiments, as well as their extrapolation to other energies, requires development of a model description of the radiation effect of charged particles on biological microstructures.

Gunter, K.

Radiation dosimetry measurements with real time radiation monitoring device (RRMD)-II in Space Shuttle STS-79

The real-time measurement of radiation environment was made with an improved real-time radiation monitoring device (RRMD)-II onboard Space Shuttle STS-79 (S/MM#4: 4th Shuttle MIR Mission, at an inclination angle of 51.6 degrees and an altitude of 250-400km) for 199 h during 17-25 September, 1996. The observation of the detector covered the linear energy transfer (LET) range of 3.5-6000 keV/micrometer. The Shuttle orbital profile in this mission was equivalent to that of the currently planned Space Station, and provided an opportunity to investigate variations in count rate and dose equivalent rate depending on altitude, longitude, and latitude in detail. Particle count rate and dose equivalent rate were mapped geographically during the mission. Based on the map of count rate, an analysis was made by dividing whole region into three regions: South Atlantic Anomaly (SAA) region, high latitude region and other regions. The averaged absorbed dose rate during the mission was 39.3 microGy/day for a LET range of 3.5-6000 keV/micrometer. The corresponding average dose equivalent rates during the mission are estimated to be 293 microSv/day with quality factors from International Commission on Radiological Protection (ICRP)-Pub. 60 and 270 microSv/day with quality factors from ICRP-Pub. 26. The effective quality factors for ICRP-Pub. 60 and 26 are 7.45 and 6.88, respectively. From the present data for particles of LET > 3.5keV/micrometer, we conclude that the average dose equivalent rate is dominated by the contribution of galactic cosmic ray (GCR) particles. The dose-detector depth dependence was also investigated.

manned

Broad frequency tuning of a Nb$_{3}$Sn superconducting microwave cavity for dark matter searches

We demonstrate a novel broad-frequency tuning mechanism for superconducting microwave cavities designed for dark matter searches. Using a Nb$_3$Sn-coated cigar-shaped cavity operating at approximately 9 GHz, we achieve continuous frequency tuning exceeding 1 GHz by mechanically separating the two cavity halves: a "tuning-by-opening" technique. Finite-element method simulations predict that radiative losses do not degrade the quality factor even for large openings, as a closed cavity with an intrinsic quality factor of $10^7$ maintains this value for apertures up to 9 mm, corresponding to a tuning range from 9.0 to 7.5 GHz. Experimental validation using both copper ring spacers and a continuous sliding mechanism confirms $Q_0$ values exceeding the dark matter quality factor across the entire explored frequency range, despite mechanical imperfections and film non-uniformities. This tuning approach avoids inserting elements into the resonant volume, making it particularly suitable for high-Q superconducting cavities in axion haloscope experiments and readily applicable to REBCO-based implementations capable of operating in multi-tesla magnetic fields.

Maiello, D. [Padua U.; INFN, Padua] (ORCID:0009000

Measurements of the linear energy transfer spectra on the Mir orbital station and comparison with radiation transport models

A tissue equivalent proportional counter designed to measure the linear energy transfer spectra (LET) in the range 0.2-1250 keV/micrometer was flown in the Kvant module on the Mir orbital station during September 1994. The spacecraft was in a 51.65 degrees inclination, elliptical (390 x 402 km) orbit. This is nearly the lower limit of its flight altitude. The total absorbed dose rate measured was 411.3 +/- 4.41 microGy/day with an average quality factor of 2.44. The galactic cosmic radiation (GCR) dose rate was 133.6 microGy/day with a quality factor of 3.35. The trapped radiation belt dose rate was 277.7 microGy/day with an average quality factor of 1.94. The peak rate through the South Atlantic Anomaly was approximately 12 microGy/min and nearly constant from one pass to another. A detailed comparison of the measured LET spectra has been made with radiation transport models. The GCR results are in good agreement with model calculations; however, this is not the case for radiation belt particles and again points to the need for improving the AP8 omni-directional trapped proton models.

Mir Project

Revealing the loss mechanisms of a 3D superconducting microwave cavity for use in a dark matter search

Superconducting microwave cavities have found applications in many areas including quantum computing, particle accelerators, and dark matter searches. Their extremely high quality factors translate to very narrow bandwidth, which makes them key components of sensitive detectors. In this study, we aim to understand the loss mechanisms of an aluminium cavity, with a fundamental mode frequency of about 2.5123 GHz, and how they change as the cavity material transitions from the superconducting to normal state. We found that at temperatures not much lower than the transition temperature $T_c$, losses are dominated by quasiparticle excitations and are well described by the Bardeen–Cooper–Schrieffer theory. The exponential decrease of the quasiparticle density below $T_c$ results in a 1000-fold increase of the quality factor, as well as a shift of the resonance frequency due to the change of the kinetic inductance of the superconductor. At very low temperatures, losses due to two-level systems begin to dominate giving a peak in the quality factor of about 2.76 x 10 7 at 130 mK. Understanding the loss mechanisms is invaluable, as the working temperature of the cavity may vary during operation regardless of its application.

Physics - Physics of elementary particles and fiel

Performance enhancement of medium temperature baked niobium SRF cavity by surface contamination removal

Medium temperature baking (300- 350 °C) enhances the quality factor of niobium superconducting radio frequency cavities. However, surface contamination introduced during vacuum furnace baking limits the quench field and may also degrade the quality factor of the cavity. To investigate this effect, a 1.3 GHz single-cell Nb cavity underwent mid-T baking, followed by a chemical treatment to remove the surface contaminants. Post-treatment measurements revealed a significant improvement in both the quality factor and the quench field.

Chouhan, Vijay [Fermilab] (ORCID:0000000282004931)

Uniform field in microwave cavities through the use of effective magnetic walls

Wire medium (WM) resonators have emerged as a promising realization for plasma haloscopes—devices designed to detect axions, a potential component of dark matter. Key factors influencing the detection probability include cavity volume, resonance quality factor, and form factor. While the form factor has been explored for resonant frequency tuning, its optimization for axion detection remains unexplored. Here, in this work, we present an approach to significantly enhancing the form factor of WM plasma haloscopes. By shifting the metal walls of the resonator by a quarter wavelength, we effectively convert an electric wall boundary condition into a magnetic wall one, allowing for an almost uniform mode. Theoretical analysis and numerical simulations confirm that this modification improves the electric field profile and boosts the form factor, while also slightly enhancing the quality factor. We validate these findings through experimental results from two prototype resonators: one with a standard geometry and another with a quarter-wave air gap between the WM and the walls. Additionally, our method provides a simple way to control the field profile within WM cavities, which can be explored for further applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Compression through decomposition into browse and residual images

Economical archival and retrieval of image data is becoming increasingly important considering the unprecedented data volumes expected from the Earth Observing System (EOS) instruments. For cost effective browsing the image data (possibly from remote site), and retrieving the original image data from the data archive, we suggest an integrated image browse and data archive system employing incremental transmission. We produce our browse image data with the JPEG/DCT lossy compression approach. Image residual data is then obtained by taking the pixel by pixel differences between the original data and the browse image data. We then code the residual data with a form of variable length coding called diagonal coding. In our experiments, the JPEG/DCT is used at different quality factors (Q) to generate the browse and residual data. The algorithm has been tested on band 4 of two Thematic mapper (TM) data sets. The best overall compression ratios (of about 1.7) were obtained when a quality factor of Q=50 was used to produce browse data at a compression ratio of 10 to 11. At this quality factor the browse image data has virtually no visible distortions for the images tested.

Novik, Dmitry A.

Risk cross sections and their application to risk estimation in the galactic cosmic-ray environment

Radiation risk cross sections (i.e. risks per particle fluence) are discussed in the context of estimating the risk of radiation-induced cancer on long-term space flights from the galactic cosmic radiation outside the confines of the earth's magnetic field. Such quantities are useful for handling effects not seen after low-LET radiation. Since appropriate cross-section functions for cancer induction for each particle species are not yet available, the conventional quality factor is used as an approximation to obtain numerical results for risks of excess cancer mortality. Risks are obtained for seven of the most radiosensitive organs as determined by the ICRP [stomach, colon, lung, bone marrow (BFO), bladder, esophagus and breast], beneath 10 g/cm2 aluminum shielding at solar minimum. Spectra are obtained for excess relative risk for each cancer per LET interval by calculating the average fluence-LET spectrum for the organ and converting to risk by multiplying by a factor proportional to R gamma L Q(L) before integrating over L, the unrestricted LET. Here R gamma is the risk coefficient for low-LET radiation (excess relative mortality per Sv) for the particular organ in question. The total risks of excess cancer mortality obtained are 1.3 and 1.1% to female and male crew, respectively, for a 1-year exposure at solar minimum. Uncertainties in these values are estimated to range between factors of 4 and 15 and are dominated by the biological uncertainties in the risk coefficients for low-LET radiation and in the LET (or energy) dependence of the risk cross sections (as approximated by the quality factor). The direct substitution of appropriate risk cross sections will eventually circumvent entirely the need to calculate, measure or use absorbed dose, equivalent dose and quality factor for such a high-energy charged-particle environment.

NASA Discipline Radiation Health

Radiation issues for piloted Mars mission

Current radiation risk for a piloted Mars mission is estimated using the idea of absorbed dose and ICRP-26, LET-dependent quality factors. In a spacecraft with aluminum walls (2 g/sq cm) at solar minimum the calculated dose equivalent is 0.73 Sv for a 406-day mission. Based on the current thinking this leads to an excess cancer mortality in a 35-year male of about 1 percent. About 75 percent of the dose equivalent is contributed by HZE particles and target fragments with average quality factors of 10.3 and 20, respectively. The entire concept of absorbed dose, quality factor, and dose equivalent as applied to such missions needs to be reexamined, in light of the fact that less than 50 percent of the nuclei in the body of the astronaut would have been traversed by a single GCR nuclei in the 406-day mission.

Badhwar, Gautam D.

A tunable dielectric resonator for axion searches at 11 GHz

In the context of axion search with haloscopes, tunable cavity resonators with high quality factor and high effective volume at frequencies above about 8 GHz are central for probing the axion-photon coupling with the required sensitivity to reach the QCD axion models. Higher order modes in dielectrically-loaded cavities allow for higher effective volumes and larger quality factors compared to basic cylindrical cavities, but a proper cavity frequency tuning mechanism to probe broad axion mass ranges is yet not available. In this work, we report about the design and construction of a tunable prototype of a single-shell dielectric resonator with its axion-sensitive pseudo-TM$_{030}$ high-order mode at about 11 GHz frequency. A clamshell tuning method previously tested for empty cylindrical resonators has been perfected for this geometry through simulations and in situ tests conducted at cryogenic temperature. Tuning is accomplished in a range of about 2 $\%$ the central frequency, without significantly impacting the quality factor of about 175000. The experimental results presented in this work demonstrate the tunability of this type of resonator, definitely confirming its applicability to high frequency axion searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Correlated Uncertainties in Radiation Shielding Effectiveness

The space radiation environment is composed of energetic particles which can deliver harmful doses of radiation that may lead to acute radiation sickness, cancer, and even death for insufficiently shielded crew members. Spacecraft shielding must provide structural integrity and minimize the risk associated with radiation exposure. The risk of radiation exposure induced death (REID) is a measure of the risk of dying from cancer induced by radiation exposure. Uncertainties in the risk projection model, quality factor, and spectral fluence are folded into the calculation of the REID by sampling from probability distribution functions. Consequently, determining optimal shielding materials that reduce the REID in a statistically significant manner has been found to be difficult. In this work, the difference of the REID distributions for different materials is used to study the effect of composition on shielding effectiveness. It is shown that the use of correlated uncertainties allows for the determination of statistically significant differences between materials despite the large uncertainties in the quality factor. This is in contrast to previous methods where uncertainties have been generally treated as uncorrelated. It is concluded that the use of correlated quality factor uncertainties greatly reduces the uncertainty in the assessment of shielding effectiveness for the mitigation of radiation exposure.

Werneth, Charles M.