Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “prototype energy model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Retrofitting Buildings with Solar-Reflective Roofs and Walls and its Impact on Peak Power Demand

Buildings are a major consumer of electricity in the United States and a significant portion of the consumption comes from heating, ventilation, and air-conditioning (HVAC) applications. Passive cooling strategies in the building envelope help to reduce the energy consumption for HVAC as well as peak electricity demand. Although being one of the most cost-effective passive cooling strategies, modern reflective roofing and reflective exterior wall technology is not well documented for its impact on peak demand. This study utilized whole building energy simulations on residential and commercial building prototype models to quantify the impact of cool roofs and cool exterior walls. The analysis was performed in three climate zones with varying insulation levels and solar reflectances for roofs and exterior walls. For both the residential and commercial buildings, the baseline building had a roof solar reflectance value of 0.10 and an exterior wall solar reflectance value of 0.25. The results from the simulations show that roofs and exterior walls with higher reflectance values increase cooling energy savings but can also increase heating energy consumption. The impact of changes in solar reflectances was greater in buildings with low roof/wall insulation levels compared to roofs/walls with higher insulation levels. A baseline for the simulations was set with the roof and exterior wall solar reflectances set at 0.1 and 0.25, respectively and simulations having varying roof and exterior wall thermal resistances were compared to the baselines.

14 SOLAR ENERGY↗

Dehumidification energy storage using a stratified liquid desiccant tank

Liquid desiccants can play an important role in reducing dehumidification energy requirements in the built environment. Because they are in a liquid state, the desiccant can be easily stored and then used to dehumidify buildings during peak energy consumption periods. By maintaining stratification between concentrated and diluted desiccant solutions, a single tank can be used to store liquid desiccant for energy storage purposes. Using a stratified tank instead of separate tanks for dilute and concentrated solutions will reduce storage costs and increase energy storage densities for liquid desiccant systems. This paper describes the experimental validation and one-dimensional modeling of a stratified liquid desiccant tank. The stratified tank prototype developed achieved 80 % of the theoretical energy storage density based on an imposed desiccant concentration change. Here, the stratified tank model was able to reasonably reproduce the experimental results. Using this model, the impact of varying operational conditions on the energy density of the stratified liquid desiccant energy storage was evaluated. Depending on the operating conditions, stratified liquid desiccant energy storage using aqueous LiCl up to 40 wt% can achieve energy storage densities in excess of 330 kWh/m 3 .

25 ENERGY STORAGE↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hybrid porous model for full reactor core scale CFD investigation of a prismatic HTGR

Three-dimensional (3-D) Computational Fluid Dynamics (CFD) analysis of a whole nuclear reactor core is a tremendous challenge due to the large geometric volume and complex structures. Here, this research presents a hybrid porous (HP) model to simplify a prismatic High Temperature Gas-cooled Reactor (HTGR) core, so 3-D CFD investigation can be performed on a full reactor core scale. In the HP model, the prototypic small coolant channels in the nuclear fuel blocks are lumped together to form multiple equivalent large coolant channels, and then the porous medium flow model is applied to each of them. Therefore, heat transfer in fuel blocks is computed by a hybrid combination of solid energy and porous flow energy equations. The similarity between the HP model and prototypic model is achieved by deriving the porous flow permeability, inertial resistance factor, and artificial thermophysical properties. Compared with the widely used whole porous (WP) flow model, the HP model preserves more realistic geometric structures, and therefore more accurate physical processes. The General Atomics' Modular High Temperature Gas-cooled Reactor (MHTGR) design was chosen as a prototype to demonstrate the methodology. Simulations were performed using the prototypic CFD model and HP model at steady-state forced circulation, steady-state natural circulation, and transient conditions that correspond to normal operation, extended period of pressurized cool down, and short-term transients after reactor shutdown, respectively. The comparison shows good agreement between the HP model and prototypic model in the maximum fuel temperature, average solid temperature, and helium flow rate, which demonstrates the potential applicability of the HP model for a full reactor core scale simulation in the future. As a benefit, the HP model reduces the mesh quantity by a factor of 50 from a prototypic model. Correspondingly, the computation time was reduced by a factor of at least 30.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Total neutron cross-section measurement on CH with a novel 3D-projection scintillator detector

In order to extract neutrino oscillation parameters, long-baseline neutrino oscillation experiments rely on detailed models of neutrino interactions with nuclei. These models constitute an important source of systematic uncertainty, partially because detectors to date have been blind to final state neutrons. Three-dimensional projection scintillator trackers comprise components of the near detectors of the next generation long-baseline neutrino experiments. Due to the good timing resolution and fine granularity, this technology is capable of measuring neutron kinetic energy in neutrino interactions on an event-by-event basis and will provide valuable data for refining neutrino interaction models and ways to reconstruct neutrino energy. Two prototypes have been exposed to the neutron beamline at Los Alamos National Laboratory (LANL) in both 2019 and 2020, with neutron energies between 0 and 800 MeV. In order to demonstrate the capability of neutron detection, the total neutron-scintillator cross section as a function of neutron energy is measured and compared to external measurements. The measured total neutron cross section in scintillator between 98 and 688 MeV is 0.36 ± 0.05 barn.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy Performance of Awnings in Residential Buildings

Residential buildings consume approximately 20% of the total primary energy in the United States. More than 50% of this energy is spent in heating, cooling, and lighting these buildings. Solar heat gain is one of the largest and most variable sources of cooling load in these buildings, while it can also provide passive heating during the heating season. Shading devices can be used to control the amount of solar heat gain in buildings. Various studies have considered how different shading devices and their applications affect energy and occupant comfort in buildings. However, most of these studies were limited to planar shading devices such as roller shades, cellular shades, and blinds. Although some theoretical studies have been performed for awnings, the energy performance of awnings has rarely been studied via either energy simulation or field measurement. In this study, the authors evaluated the energy performance of typical operable awnings by using field data, aided by simulation. Awnings were installed on a real house, and measurements were performed to evaluate the thermal performance of the awning. The measured data were then used to develop a calibrated energy model and evaluate the awning’s energy performance. The annual simulation of the building model used showed that awnings left in the closed position from April to September can reduce annual HVAC energy consumption by 15% compared with a building without any shades. The validated model was used in US Department of Energy prototype buildings to evaluate awning energy performance in climate zones 1A through 4B via energy simulation. For these prototype buildings, energy savings of up to 1,034 kWh were achieved for a building with a conditioned floor area of 2,377 ft 2 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Prototypes Based on ANSI/ASHRAE/IES Standard 90.1-2019 Appendix G PRM: Technical Support Document

The two paths for documenting compliance with ANSI/ASHRAE/IES Standard 90.1 are the prescriptive path and the performance path. Beyond code programs and rating systems (for example, USGBC-LEED ) are primarily known to use a third path – the Appendix G Performance Rating Method. An update in the 2016 edition of Standard 90.1 approved the Appendix G Performance Rating System for code compliance, extending its application and allowing for greater consistency of modeling rules for code and beyond code building energy modeling. The Appendix G PRM provides rules for the development of whole building energy models of baseline and proposed models for calculating the “performance cost index target” value using the simulated energy results of the baseline and proposed models and the building performance factors published in Table 4.2.1.1 of the Standard. This report documents (1) the methodology used for development of the baseline and proposed energy models of the Pacific Northwest National Laboratory and U.S. Department of Energy commercial building prototypes using the Appendix G Performance Rating Method; and (2) the building performance factors that were calculated using those models.

97 MATHEMATICS AND COMPUTING↗

Valuing Residential Energy Efficiency: Analysis for a Prototypical Southeastern Utility [Slides]

The increasing amount of variable renewable energy resources and shifts towards more end-use and vehicle electrification suggests profound changes to power system planning and operation. Specifically, renewable energy is expected to shift net peak demand from late afternoon to early evening and end-use electrification may significantly increase winter peak demand. Residential energy efficiency is likely to align well with these shifts as it tends to produce savings in the early evening (e.g., from lighting measures) and coincident with heating loads (e.g., from envelope and space conditioning measures). Despite the opportunity to decrease system costs and emissions, residential energy efficiency is often limited by static valuation methods and its economic potential is considerably less than its technical potential. Using hourly residential energy efficiency characterizations, utility program cost data, and a capacity expansion model, we estimate the benefits of residential energy efficiency for a prototypical, summer-peaking utility in the Southeastern region. We first establish the cost-effective residential energy efficiency portfolio through “competition” with supply-side resources in a forward-looking capacity expansion model. Importantly, we then evaluate several scenarios intended to drive an increasing amount of cost-effective residential energy efficiency through measure cost reductions, increased customer adoption, policy goals (e.g., carbon price), and delivery of an integrated package of measures. The results quantify total system cost and emissions reductions, fossil-fuel plant retirements, and peak demand reductions. Results suggest the design and prioritization of policies and programs to access the untapped amount of cost-effective residential energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the Spectral Energy Distribution of the Active Galactic Nucleus inside NGC 4395

We study the broadband spectral energy distribution (SED) of the prototypical low-mass active galactic nucleus (AGN) in NGC 4395. We jointly model the optical through mid-IR SED with a combination of galaxy and AGN light, and find that on arcsecond scales the AGN dominates at most wavelengths. However, there is still some ambiguity about emission from the galaxy, owing partially to the strong short-term variability of the black hole. We investigate the use of smooth- and clumpy-torus models in order to disentangle the nuclear IR emission, as well as exploring the use of poloidal wind emission to account for the blue spectral slope observed in the near-IR. Even when simultaneously fitting the full optical–IR spectral range, we find that degeneracies still remain in the best-fit models. We conclude that high-spatial-resolution and wider-wavelength coverage with the JWST is needed to understand the mid-IR emission in this complex, highly variable object, which is the best nearby example to provide a blueprint to finding other low-mass AGNs via their mid-IR emission in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Interplay of vibration- and environment-assisted energy transfer

Abstract We study the interplay between two environmental influences on excited state energy transfer in photosynthetic light harvesting complexes, namely, vibrationally assisted energy transfer (VAET) and environment-assisted quantum transport (ENAQT), considering a dimeric chromophore donor–acceptor model as a prototype for larger systems. We demonstrate how the basic features of the excitonic energy transfer are influenced by these two environments, both separately and together, with the environment being fully quantum in the case of VAET and treated in the Haken–Strobl–Reineker classical limit in the case of ENAQT. Our results reveal that in the weak noise regime, the presence of a classical noise source is detrimental to the energy transfer that is resonantly assisted by the exciton-vibration interactions intrinsic to VAET. In the strong noise regime we reproduce all the features of ENAQT, including the turnover into a Zeno regime where energy transfer is suppressed, and VAET is insignificant.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Validation of Subsystem Models for a Novel Variable Displacement Hydraulic Motor

A novel, variable displacement, low-speed high-torque hydraulic motor is being developed that is expected to be highly efficient across a broad operating range. To ensure the final hardware achieves the expected performance, the models used in the development of the motor must be experimentally validated and revised, as necessary. The specific focus in this work is on mechanical energy loss models that were used to guide the design of a single-cylinder motor prototype and on experimental tests used for model validation. Ideally each model, whether friction loss in a piston/cylinder interface or energy loss due to leakage in a valve , would be individually validated by an independent test. This granular approach would remove any question of where the error lies and result in highly accurate models. However, many motor components have multiple forms of energy loss, creating difficulty in validating individual losses. Additionally, it is not physically realizable to divide many components into an individual model equivalent test. Testing the motor as a full assembly is possible, but pinpointing the source of discrepancies between the model and the hardware becomes difficult with dozens of models potentially being partially responsible. A compromise was found by separating the motor into functional component groups that are characterized by the type of loss and ability to test each subcomponent independently. By checking for correlation between test observations and model predictions, revisions could be implemented into the models. This allows future solutions to be more accurately predicted in the design phase to drive the design of better machines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Cyber-Physical Situational Awareness for Energy Systems: A Secure Foundation for Next-Generation Energy Management

This document provides the final report for the CYPRES project. The purpose is (1) to highlight and summarize its major accomplishments and (2) to provide guidance on how its outcomes have informed and can inform important additional research and technology transfer. The goal of CYPRES was the research, development, and demonstration of a security-oriented next generation cyber-physical EMS for electric power systems that detects malicious and abnormal events through the fusion of cyber and physical data. To achieve this, the CYPRES project team researched, developed, and built a prototype of the solution, referred to as the CYPRES EMS. The CYPRES EMS is a proof-of-concept cyber-physical platform that demonstrates the management of the energy system, communications, security, and cyber-physical grid modeling and analytics. As part of the capabilities of the CYPRES EMS, the team designed and developed a suite of power system applications for monitoring, risk analyses, detection, and control that are inherently cyberaware. At its core, the project aimed to research, develop, and demonstrate a security-oriented next-generation cyber-physical Energy Management System (EMS) capable of detecting malicious and abnormal events through the innovative fusion of cyber and physical data. This approach represents a fundamental shift from traditional EMS, reimagining how critical infrastructure can be protected through unified cyber-aware and physics-aware secure data flow pipelines. The project’s cornerstone deliverable, the CYPRES EMS, serves as a proof-of-concept cyber-physical platform that revolutionizes the management of energy systems, communications, security, and cyber-physical grid modeling and analytics. This prototype implements a comprehensive suite of power system applications for monitoring, risk analyses, detection, and control, all designed with inherent cyber awareness. The system’s architecture extends from end-devices in the field through to control center applications, establishing a secure and resilient control framework that addresses the challenges posed by diverse devices of unknown trustworthiness connecting to modern power systems. Through this innovative approach to deep cyber-physical situational awareness, the CYPRES project not only advances the state-of-the-art in energy infrastructure protection but also establishes a new paradigm for how EMS can be designed, deployed, and operated in an increasingly complex threat landscape. The findings and developments from this project provide crucial insights for stakeholders across the energy sector, offering a blueprint for enhancing the reliability and resilience of our nation’s critical energy infrastructure in the face of evolving cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

pnnl/simple-building-calculator

The Simple Building Calculator is a web application that estimates annual energy use using regression models that have been fit to simulation results for the DOE Commercial Prototype Building Models. The tool is a single-page application that will allow a user to rapidly analyze the impact of energy efficiency measures and design options on building performance. As it uses linear regression models rather than more complicated machine learning models or physics based simulation, the tool can deploy easily and run client-side.

Xu, Weili↗

Cellular Shade Energy Savings in a Commercial Setting

Windows cause approximately 1.7 quad of heating and cooling energy consumption in the United States. This energy consumption can be reduced by using high-efficiency window attachments. Common Venetian blinds and planar shades, such as roller shades, might block solar radiation, but they do not provide a significant improvement to window system thermal transmittance. Cellular shades have better thermal performance compared to other shading devices because of the honeycomb structure that traps air in pockets to create thermal insulation. However, evaluating the energy savings potential of cellular shades using experimental testing in commercial settings is limited. Moreover, the effect of cellular shades on daylighting and glare is yet to be evaluated using field testing. In this study, experimental testing of cellular shades was performed in a real building with emulated occupancy for both a cooling and a heating season. Compared with a room without shades, the use of cellular shades in experimental testing showed incremental energy savings of 4.6% to 9.4% for cooling and higher than 20% for heating. The experimental data were used to calibrate the baseline energy model and validate the cellular shades model. Annual simulation of cellular shades was performed for a medium office prototype building using the validated cellular shades model. The annual simulation was performed in Phoenix, Nashville, and Rochester. The annual savings for HVAC energy was 25% for Phoenix, 27% for Nashville, and 19% for Rochester.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

EVALUATION OF HOT CHANNEL FACTOR FOR SODIUM-COOLED FAST REACTORS WITH MULTI-PHYSICS TOOLKIT

The evaluation of hot channel factor (HCF) is of great significance to the quantification of safety margins for reactor designs. In this paper, HCFs for a sodium-cooled fast reactor (SFR) are evaluated with the Simulation-based High-efficiency Advanced Reactor Prototyping (SHARP) toolkit, which is developed under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Campaign of DOE for multi-physics reactor performance and safety simulations. The high-fidelity neutronics and thermal hydraulics solvers PROTEUS and Nek5000 in the SHARP toolkit are coupled to perform the multi-physics simulations for HCF evaluation. The HCFs induced by cladding manufacturing tolerance, fissile content mal-distribution, wire orientation and uncertainties on the cladding, coolant, and fuel properties are evaluated for a reference core SFR design (AFR-100). The HCFs calculated with the SHARP toolkit are compared to legacy HCFs for similar reactor types. The comparison demonstrates the reduction or elimination of modeling uncertainties in the calculation of HCFs using high fidelity advanced modeling and simulation tools without the need of expensive experiments. Moreover, the reduction of the uncertainties on HCFs evaluation allows an increase in nominal parameters and safety margin, which in turn improves the economic competitiveness of the SFR.

Hot channel factor (HCF)↗

A Machine Learning-Assisted Framework to Control Thermally Anisotropic Building Envelopes in Residential Buildings

To curb the energy consumption of buildings and their related CO2 emissions, Oak Ridge National Laboratory (ORNL) has developed the thermally anisotropic building envelope (TABE) —a multi-layer design comprising insulation materials and metal foils connected to thermal loops. In this study, a machine learning-assisted framework was developed to control the TABE in residential buildings to reduce the computation load for future optimal rule-based control and application. First, a 2D finite element model was established in COMSOL to calculate the hourly heat flux through exterior walls installed with the TABE. Then, TABE wall heat fluxes were simulated for various given indoor and outdoor boundary conditions, as well as thermal loops fluid temperatures and flow rates. Since the finite element simulations are computationally expensive, an artificial neural network (ANN) was then trained to use as a proxy of the finite element (COMSOL) modeling. Finally, the trained ANN model was coupled with the EnergyPlus model to predict the energy consumption of a US Department of Energy prototype single-family house installed with the TABE. An optimal simple rule-based control was determined from predefined rules for a case study. The results demonstrate that the developed machine learning–assisted framework can reduce 99.9% of the computation time while efficiently managing residential building energy for installed TABE walls.

Shen, Zhenglai↗

Counting Calories: Light Yield Studies with ADRIANO2 Calorimeter Prototype

Precision in measuring particle energies is crucial to understand the intricacies of high-energy physics beyond the standard model. For the REDTOP experiment to detect η/η´ mesons potentially decaying into dark-matter particles not yetdiscovered, it is essential to have accurate measurements through sophisticated and innovative detector technology built with special properties. The ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) Calorimeter Prototype plays a pivotal role in advancing detection capabilities, offering the potential to enhance the particle identification procedure. This study delves into the characterization of the ADRIANO2 prototype’s light yield with the ultimate goal of contributing to broader high-energy physics objectives. To estimate the light yield for the ADRIANO2 prototype, we must calibrate the light sensors as well as collect data from beams of known properties. Several prototypes of the ADRIANO2 detector have been tested at the Mtest Facility at Fermi National Accelerator Laboratory in the last few years. This paper attempts to summarize the calibration of one such ADRIANO2 prototype to estimate its experimental performance.

43 PARTICLE ACCELERATORS↗