Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “prototype energy model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Updated OpenStudio (OS) Small Office Prototype Model

The U.S. Department of Energy (DOE) supports the development of commercial building energy codes and standards by participating in industry review, update processes, and providing technical analyses to support both published model codes and potential changes. DOE publishes its findings to ensure transparency in its support, and to make its analysis available for both public review and use. In conjunction with this effort, DOE’s flagship building energy model (BEM) tools consist of the open-source EnergyPlus simulation engine and OpenStudio. These tools allow a user to modify a building, estimate energy use, and new releases are typically downloaded by over 20,000 users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2015 IECC Determination of Energy Savings: Preliminary Technical Analysis

This report documents the technical analysis used to evaluate whether residential buildings constructed to meet the requirements of the 2015 IECC would result in energy-efficiency improvements over residential buildings constructed to meet the requirements of the previous edition, the 2012 IECC. PNNL considered all code change proposals approved for inclusion in the 2015 IECC during the ICC code development cycle, and evaluated their combined impact on a suite of prototypical residential building energy models across all U.S. climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancements to ASHRAE Standard 90.1 Prototype Building Models

This report focuses on enhancements to prototype building models used to determine the energy impact of various versions of ANSI/ASHRAE/IES Standard 90.1. Since the last publication of the prototype building models, PNNL has made numerous enhancements to the original prototype models compliant with the 2004, 2007, and 2010 editions of Standard 90.1. Those enhancements are described here and were made for several reasons: (1) to change or improve prototype design assumptions; (2) to improve the simulation accuracy; (3) to improve the simulation infrastructure; and (4) to add additional detail to the models needed to capture certain energy impacts from Standard 90.1 improvements. These enhancements impact simulated prototype energy use, and consequently impact the savings estimated from edition to edition of Standard 90.1.

ASHRAE 90.1↗

High-Efficiency Thermoelectric Clothes Dryer (CRADA Final Report)

A typical clothes dryer in the US accounts for 7% of the average residential customer’s electric bill. Nationwide, consumers pay about $\$$9 billion annually for clothes drying. While energy efficiency for most household appliances has improved by a factor of 2 or more in recent decades, today’s clothes dryers perform similarly to units from the 1970s. Dryer efficiency is measured by the combined energy factor (CEF), with today’s units typically drying 3.73 lb of cloth per kWh consumed. An ENERGY STAR qualified unit must achieve 3.93 lb/kWh (for standard size electric units) and dry in less than 80 minutes. ORNL and CRADA partner Samsung Electronics America have developed an efficient prototype clothes dryer that uses thermoelectric heat pumps instead of electric resistance to dry the clothes. The prototype fabricated at ORNL successfully demonstrated in the laboratory a CEF of 6.89 lb/kWh at standard conditions of 75°F and 50% Relative Humidity (RH), exceeding the original project target of 6.0 lb/kWh. Additional trials on the same prototype achieved faster dry time with slightly lower CEF, meeting all requirements for ENERGY STAR product qualification. Deploying dryers with energy factor of 6 nationwide represents a technical potential of 234 TBtu/yr primary energy savings. The modeling and prototype development activities for the thermoelectric clothes dryer under this CRADA are summarized in this final report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing overall building energy performance of a large population of residential single-family homes using limited field data

The U.S. Department of Energy (DOE), through the Building Energy Codes Program (BECP), supports building energy code development and implementation processes to achieve the maximum practicable, cost-effective improvements in energy efficiency while providing safe, healthy buildings for occupants. Currently, there is a lack of statistically representative data that shows how energy codes are implemented in the field and the energy savings opportunities that exist. To address this gap, DOE initiated a research study targeted at new residential single-family homes in 8 states starting in the fall of 2014. The study comprises of a baseline phase to determine current levels of compliance with the key energy provisions of the residential building energy code, identify issues, and calculate potential energy savings from improved compliance; a second phase implementing education, training and outreach activities designed to increase targeted code compliance; and a post-study phase to measure the impact of the training and outreach activities compared to the baseline phase. Initial analyses determined the code requirements with the largest energy impact and the minimum number of observations required to detect statistically significant differences in energy use. Data was collected in the field during a single site visit to avoid bias from repeat visits. However, the single site visit principle prevented energy simulation of individual homes due to the lack of all required model inputs. To address this, energy simulation was conducted using Pacific Northwest National Laboratory’s prototype building models and employing bootstrap random sampling on the data collected from all homes visited. The modeled energy consumption using the observed field data was evaluated relative to that associated with the minimum code requirements and potential savings associated with improved compliance of select items were assessed. This paper discusses the methodology developed for this field study, and presents the results and findings from the baseline phase.

Xie, YuLong↗

An Analysis of Representative Heating Load Lines for Residential HSPF Ratings

This report describes an analysis to investigate representative heating loads for single-family detached homes using current EnergyPlus simulations (DOE 2014a). Hourly delivered load results are used to determine binned load lines using US Department of Energy (DOE) residential prototype building models (DOE 2014b) developed by Pacific Northwest National Laboratory (PNNL). The selected residential single-family prototype buildings are based on the 2006 International Energy Conservation Code (IECC 2006) in the DOE climate regions. The resulting load lines are compared with the American National Standards Institute (ANSI)/Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard 210/240 (AHRI 2008) minimum and maximum design heating requirement (DHR) load lines of the heating seasonal performance factor (HSPF) ratings procedure for each region. The results indicate that a heating load line closer to the maximum DHR load line, and with a lower zero load ambient temperature, is more representative of heating loads predicted for EnergyPlus prototype residential buildings than the minimum DHR load line presently used to determine HSPF ratings. An alternative heating load line equation was developed and compared to binned load lines obtained from the EnergyPlus simulation results. The effect on HSPF of the alternative heating load line was evaluated for single-speed and two-capacity heat pumps, and an average HSPF reduction of 16% was found. The alternative heating load line relationship is tied to the rated cooling capacity of the heat pump based on EnergyPlus autosizing, which is more representative of the house load characteristics than the rated heating capacity. The alternative heating load line equation was found to be independent of climate for the six DOE climate regions investigated, provided an adjustable zero load ambient temperature is used. For Region IV, the default DOE climate region used for HSPF ratings, the higher load line results in an ~28% increase in delivered heating load and an ~52% increase in the estimated heating operating cost over that given in the AHRI directory (AHRI 2014).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of energy savings potential of variable refrigerant flow (VRF) from variable air volume (VAV) in the U.S. climate locations

Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assess the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Residential Prototype Building Models and Analysis System for Large-Scale Energy Efficiency Studies Using EnergyPlus

ABSTRACT: Recent advances in residential building energy efficiency and codes have resulted in increased interest in detailed residential building energy models using the latest energy simulation software. One of the challenges of developing residential building models to characterize new residential building stock is to allow for flexibility to address variability in house features like geometry, configuration, HVAC systems etc. Researchers solved this problem in a novel way by creating a simulation structure capable of creating fully-functional EnergyPlus batch runs using a completely scalable residential EnergyPlus template system. This system was used to create a set of thirty-two residential prototype building models covering single- and multifamily buildings, four common foundation types and four common heating system types found in the United States (US). A weighting scheme with detailed state-wise and national weighting factors was designed to supplement the residential prototype models. The complete set is designed to represent a majority of new residential construction stock. The entire structure consists of a system of utility programs developed around the core EnergyPlus simulation engine to automate the creation and management of large-scale simulation studies with minimal human effort. The simulation structure and the residential prototype building models have been used for numerous large-scale studies, one of which is briefly discussed in this paper.

Mendon, Vrushali V.↗

Peak cooling load shift capability of a thermal energy storage system integrated with an active insulation system in US climate zones

This study aims to evaluate a thermal energy storage (TES) system integrated with an active insulation system (AIS) to form a TES + AIS integrated wall system as a partition and as a secondary cooling system to shift the peak load and reduce cooling energy consumption. To understand and demonstrate its cooling performance, the TES + AIS integrated wall system was installed in an office building in Oak Ridge, Tennessee. To investigate the effect of the TES + AIS integrated wall system in a typical office building and various climate zones, the US Department of Energy’s prototype office building model was modified to accommodate the proposed system. In this work, results showed that the minimum size of the proposed system to achieve energy savings varies depending on climate conditions. The minimum size of the proposed system for cooling energy saving and shifting peak cooling demand in climate zones 2, 3, and 5 is 29.7 m 2 , whereas it is 44.6 m 2 in zones 4 and 6. By installing the minimum size of the proposed system, 11.3 % to 16.4 % of cooling energy can be shifted during discharge hours in a representative summer day.

25 ENERGY STORAGE↗

CERES ERBE-like Monthly Regional Averages (ES-9) in HDF (CER_ES9_TRMM-PFM_Edition2)

The ERBE-like Monthly Regional Averages (ES-9) product contains a month of space and time averaged Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The ES-9 is also produced for combinations of scanner instruments. All instantaneous shortwave and longwave fluxes at the Top-of-the-Atmosphere (TOA) from the CERES ES-8 product for a month are sorted by 2.5-degree spatial regions, by day number, and by the local hour of observation. The mean of the instantaneous fluxes for a given region-day-hour bin is determined and recorded on the ES-9 along with other flux statistics and scene information. For each region, the daily average flux is estimated from an algorithm that uses the available hourly data, scene identification data, and diurnal models. This algorithm is 'like' the algorithm used for the Earth Radiation Budget Experiment (ERBE). The ES-9 also contains hourly average fluxes for the month and an overall monthly average for each region. These average fluxes are given for both clear-sky and total-sky scenes. The following CERES ES9 data sets are currently available: CER_ES9_FM1+FM2_Edition1 CER_ES9_PFM+FM1+FM2_Edition1 CER_ES9_PFM+FM1+FM2_Edition2 CER_ES9_PFM+FM1_Edition1 CER_ES9_PFM+FM2_Edition1 CER_ES9_PFM+FM1_Edition2 CER_ES9_PFM+FM2_Edition2 CER_ES9_TRMM-PFM_Edition1 CER_ES9_TRMM-PFM_Edition2 CER_ES9_Terra-FM1_Edition1 CER_ES9_Terra-FM2_Edition1 CER_ES9_FM1+FM2_Edition2 CER_ES9_Terra-FM1_Edition2 CER_ES9_Terra-FM2_Edition2 CER_ES9_Aqua-FM3_Edition1 CER_ES9_Aqua-FM4_Edition1 CER_ES9_FM1+FM2+FM3+FM4_Edition1 CER_ES9_Aqua-FM3_Edition2 CER_ES9_Aqua-FM4_Edition2 CER_ES9_FM1+FM3_Edition2 CER_ES9_FM1+FM4_Edition2 CER_ES9_Aqua-FM3_Edition1-CV CER_ES9_Aqua-FM4_Edition1-CV CER_ES9_Terra-FM1_Edition1-CV CER_ES9_Terra-FM2_Edition1-CV. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2000-03-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=2.5 degree; Longitude_Resolution=2.5 degree; Horizontal_Resolution_Range=250 km - < 500 km or approximately 2.5 degrees - < 5.0 degrees; Temporal_Resolution=hourly, daily, monthly; Temporal_Resolution_Range=Hourly - < Daily, Daily - < Weekly, Monthly - < Annual].

CLEAR-SKY SHORTWAVE FLUX↗

CERES ERBE-like Monthly Regional Averages (ES-9) in HDF (CER_ES9_Terra-FM2_Edition1)

The ERBE-like Monthly Regional Averages (ES-9) product contains a month of space and time averaged Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The ES-9 is also produced for combinations of scanner instruments. All instantaneous shortwave and longwave fluxes at the Top-of-the-Atmosphere (TOA) from the CERES ES-8 product for a month are sorted by 2.5-degree spatial regions, by day number, and by the local hour of observation. The mean of the instantaneous fluxes for a given region-day-hour bin is determined and recorded on the ES-9 along with other flux statistics and scene information. For each region, the daily average flux is estimated from an algorithm that uses the available hourly data, scene identification data, and diurnal models. This algorithm is 'like' the algorithm used for the Earth Radiation Budget Experiment (ERBE). The ES-9 also contains hourly average fluxes for the month and an overall monthly average for each region. These average fluxes are given for both clear-sky and total-sky scenes. The following CERES ES9 data sets are currently available: CER_ES9_FM1+FM2_Edition1 CER_ES9_PFM+FM1+FM2_Edition1 CER_ES9_PFM+FM1+FM2_Edition2 CER_ES9_PFM+FM1_Edition1 CER_ES9_PFM+FM2_Edition1 CER_ES9_PFM+FM1_Edition2 CER_ES9_PFM+FM2_Edition2 CER_ES9_TRMM-PFM_Edition1 CER_ES9_TRMM-PFM_Edition2 CER_ES9_Terra-FM1_Edition1 CER_ES9_Terra-FM2_Edition1 CER_ES9_FM1+FM2_Edition2 CER_ES9_Terra-FM1_Edition2 CER_ES9_Terra-FM2_Edition2 CER_ES9_Aqua-FM3_Edition1 CER_ES9_Aqua-FM4_Edition1 CER_ES9_FM1+FM2+FM3+FM4_Edition1 CER_ES9_Aqua-FM3_Edition2 CER_ES9_Aqua-FM4_Edition2 CER_ES9_FM1+FM3_Edition2 CER_ES9_FM1+FM4_Edition2 CER_ES9_Aqua-FM3_Edition1-CV CER_ES9_Aqua-FM4_Edition1-CV CER_ES9_Terra-FM1_Edition1-CV CER_ES9_Terra-FM2_Edition1-CV. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2005-10-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=2.5 degree; Longitude_Resolution=2.5 degree; Horizontal_Resolution_Range=250 km - < 500 km or approximately 2.5 degrees - < 5.0 degrees; Temporal_Resolution=hourly, daily, monthly; Temporal_Resolution_Range=Hourly - < Daily, Daily - < Weekly, Monthly - < Annual].

CLEAR-SKY SOLAR INCIDENCE↗

CERES ERBE-like Monthly Geographical Averages (ES-4) in HDF (CER_ES4_FM1+FM2_Edition1)

The ERBE-like Monthly Geographical Averages (ES-4) product contains a month of space and time averaged Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The ES-4 is also produced for combinations of scanner instruments. For each observed 2.5-degree spatial region, the daily average, the hourly average over the month, and the overall monthly average of shortwave and longwave fluxes at the Top-of-the-Atmosphere (TOA) from the CERES ES-9 product are spatially nested up from 2.5-degree regions to 5- and 10-degree regions, to 2.5-, 5-, and 10-degree zonal averages, and to global monthly averages. For each nested area, the albedo and net flux are given. For each region, the daily average flux is estimated from an algorithm that uses the available hourly data, scene identification data, and diurnal models. This algorithm is 'like' the algorithm used for the Earth Radiation Budget Experiment (ERBE). The following CERES ES4 data sets are currently available: CER_ES4_FM1+FM2_Edition1 CER_ES4_PFM+FM1+FM2_Edition1 CER_ES4_PFM+FM1+FM2_Edition2 CER_ES4_PFM+FM1_Edition1 CER_ES4_PFM+FM2_Edition1 CER_ES4_TRMM-PFM_Edition1 CER_ES4_TRMM-PFM_Edition2 CER_ES4_Terra-FM1_Edition1 CER_ES4_Terra-FM2_Edition1 CER_ES4_FM1+FM2_Edition2 CER_ES4_Terra-FM1_Edition2 CER_ES4_Terra-FM2_Edition2 CER_ES4_Aqua-FM3_Edition1 CER_ES4_Aqua-FM4_Edition1 CER_ES4_FM1+FM2+FM3+FM4_Edition1 CER_ES4_Aqua-FM3_Edition2 CER_ES4_Aqua-FM4_Edition2 CER_ES4_FM1+FM3_Edition2 CER_ES4_FM1+FM4_Edition2 CER_ES4_PFM+FM1_Edition2 CER_ES4_PFM+FM2_Edition2 CER_ES4_Aqua-FM3_Edition1-CV CER_ES4_Aqua-FM4_Edition1-CV CER_ES4_Terra-FM1_Edition1-CV CER_ES4_Terra-FM2_Edition1-CV. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2003-12-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=2.5 degree; Longitude_Resolution=2.5 degree; Horizontal_Resolution_Range=250 km - < 500 km or approximately 2.5 degrees - < 5.0 degrees; Temporal_Resolution=1 month; Temporal_Resolution_Range=Monthly - < Annual].

EOSDIS↗

CERES ERBE-like Instantaneous TOA Estimates (ES-8) in HDF (CER_ES8_Aqua-FM4_Edition1)

The ES-8 archival data product contains a 24-hour, single-satellite, instantaneous view of scanner fluxes at the top-of-atmosphere (TOA) reduced from spacecraft altitude unfiltered radiances using Earth Radiation Budget Experiment (ERBE) scanner Inversion algorithms and the ERBE shortwave (SW) and longwave (LW) Angular Distribution Models (ADMs). The ES-8 also includes the total (TOT), SW, LW, and window (WN) channel radiometric data; SW, LW, and WN unfiltered radiance values; and the ERBE scene identification for each measurement. These data are organized according to the CERES 3.3-second scan into 6.6-second records. As long as there is one valid scanner measurement within a record, the ES-8 record will be generated. The following CERES ES8 data sets are currently available: CER_ES8_TRMM-PFM_Edition1 CER_ES8_TRMM-PFM_Edition2 CER_ES8_TRMM-PFM_Transient-Ops2 CER_ES8_Terra-FM1_Edition1 CER_ES8_Terra-FM2_Edition1 CER_ES8_Terra-FM1_Edition2 CER_ES8_Terra-FM2_Edition2 CER_ES8_Aqua-FM3_Edition1 CER_ES8_Aqua-FM4_Edition1 CER_ES8_Aqua-FM3_Edition2 CER_ES8_Aqua-FM4_Edition2 CER_ES8_Aqua-FM3_Edition1-CV CER_ES8_Aqua-FM4_Edition1-CV CER_ES8_Terra-FM1_Edition1-CV CER_ES8_Terra-FM1_Edition1-CV. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1997-12-27; Stop_Date=2005-03-29] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 day; Temporal_Resolution_Range=Daily - < Weekly].

SHORTWAVE FILTERED RADIANCE↗

CERES BiDirectional Scans (BDS) data in HDF (CER_BDS_Aqua-FM3_Edition2)

Each BiDirectional Scans (BDS) data product contains twenty-four hours of Level-1b data for each CERES scanner instrument mounted on each spacecraft. The BDS includes samples taken in normal and short Earth scan elevation profiles in both fixed and rotating azimuth scan modes (including space, internal calibration, and solar calibration views). The BDS contains Level-0 raw (unconverted) science and instrument data as well as the geolocated converted science and instrument data. The BDS contains additional data not found in the Level-0 input file, including converted satellite position and velocity data, celestial data, converted digital status data, and parameters used in the radiance count conversion equations. The following CERES BDS data sets are currently available: CER_BDS_TRMM-PFM_Edition1 CER_BDS_Terra-FM1_Edition1 CER_BDS_Terra-FM2_Edition1 CER_BDS_Terra-FM1_Edition2 CER_BDS_Terra-FM2_Edition2 CER_BDS_Aqua-FM3_Edition1 CER_BDS_Aqua-FM4_Edition1 CER_BDS_Aqua-FM3_Edition2 CER_BDS_Aqua-FM4_Edition2 CER_BDS_Aqua-FM3_Edition1-CV CER_BDS_Aqua-FM4_Edition1-CV CER_BDS_Terra-FM1_Edition1-CV CER_BDS_Terra-FM2_Edition1-CV. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1997-12-27; Stop_Date=2006-01-01] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 day; Temporal_Resolution_Range=Daily - < Weekly].

SHORTWAVE FILTERED RADIANCE UPWARDS↗

CERES ERBE-like Monthly Geographical Averages (ES-4) in HDF (CER_ES4_Aqua-FM4_Edition2)

The ERBE-like Monthly Geographical Averages (ES-4) product contains a month of space and time averaged Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The ES-4 is also produced for combinations of scanner instruments. For each observed 2.5-degree spatial region, the daily average, the hourly average over the month, and the overall monthly average of shortwave and longwave fluxes at the Top-of-the-Atmosphere (TOA) from the CERES ES-9 product are spatially nested up from 2.5-degree regions to 5- and 10-degree regions, to 2.5-, 5-, and 10-degree zonal averages, and to global monthly averages. For each nested area, the albedo and net flux are given. For each region, the daily average flux is estimated from an algorithm that uses the available hourly data, scene identification data, and diurnal models. This algorithm is 'like' the algorithm used for the Earth Radiation Budget Experiment (ERBE). The following CERES ES4 data sets are currently available: CER_ES4_FM1+FM2_Edition1 CER_ES4_PFM+FM1+FM2_Edition1 CER_ES4_PFM+FM1+FM2_Edition2 CER_ES4_PFM+FM1_Edition1 CER_ES4_PFM+FM2_Edition1 CER_ES4_TRMM-PFM_Edition1 CER_ES4_TRMM-PFM_Edition2 CER_ES4_Terra-FM1_Edition1 CER_ES4_Terra-FM2_Edition1 CER_ES4_FM1+FM2_Edition2 CER_ES4_Terra-FM1_Edition2 CER_ES4_Terra-FM2_Edition2 CER_ES4_Aqua-FM3_Edition1 CER_ES4_Aqua-FM4_Edition1 CER_ES4_FM1+FM2+FM3+FM4_Edition1 CER_ES4_Aqua-FM3_Edition2 CER_ES4_Aqua-FM4_Edition2 CER_ES4_FM1+FM3_Edition2 CER_ES4_FM1+FM4_Edition2 CER_ES4_PFM+FM1_Edition2 CER_ES4_PFM+FM2_Edition2 CER_ES4_Aqua-FM3_Edition1-CV CER_ES4_Aqua-FM4_Edition1-CV CER_ES4_Terra-FM1_Edition1-CV CER_ES4_Terra-FM2_Edition1-CV. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2005-03-29] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=2.5 degree; Longitude_Resolution=2.5 degree; Horizontal_Resolution_Range=250 km - < 500 km or approximately 2.5 degrees - < 5.0 degrees; Temporal_Resolution=1 month; Temporal_Resolution_Range=Monthly - < Annual].

CLEAR-SKY ALBEDO↗

Accelerating Optimal Integration of Energy Efficiency Strategies with Industrialized Modular Construction: Preprint

The National Renewable Energy Laboratory's (NREL's) Industrialized Construction Innovation team first introduced the Industrialized Construction Assessment Framework to achieve affordable, net-zero energy (NZE) modular multifamily buildings in the 2020 ACEEE paper "Integrating Energy Efficiency Strategies with Industrialized Construction for our Clean Energy Future." Since then, NREL has continued to drive the ambitious plan to accelerate optimal integration of energy efficiency strategies during industrialized construction with little or no additional cost, labor, and production time. This follow-on paper introduces the Energy in Modular (EMOD) buildings method and presents NREL's research efforts over the last two years in collaboration with industry, including affordable housing partners. NREL has developed an idealized NZE modular multifamily building design that incorporates five energy efficiency strategies well suited for industrialized construction in factories: (1) envelope thermal control, (2) envelope infiltration control, (3) mechanical, electrical, and plumbing systems, (4) smart controls, and (5) solar plus storage. This paper highlights results from leveraging design for manufacturing and assembly principles, testing, and validation pilots with factory partners; demonstrating pod prototypes in test stand at NREL; and performing simulations. Overall, these research efforts address barriers to whole-building system integration, such as poor installation quality of thermal and air barriers; lack of unitized systems for space conditioning, energy recovery and ventilation, and water heating; problematic on-site installation, commissioning, and configuration of controls; and lack of cost-effective integration for grid-friendly design and emerging technologies. Conclusively, the paper delineates next steps for future work with NREL's partners toward developing a transformational pathway for our clean energy future.

affordable housing↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗