Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High-Precision Timing of Millisecond Pulsars and Precision Astrometry

We present the technique of long-term, high-precision timing of millisecond pulsars as applied to precision astrometry. We provide a tutorial on pulsars and pulsar timing, as well as up-to-date results of long-term observation of two millisecond pulsars. We consider the feasibility of tying the extragalactic and optical reference frames to that defined by solar system objects, and we conclude that precision astrometry from millisecond pulsar timing will continue to yield interesting results at an accelerating pace in the next decade.

pulsars pulsar timing millisecond pulsars precisio↗

Towards Precision-Aware Fault Tolerance Approaches for Mixed-Precision Applications

Graphics Processing Units (GPUs), the dominantly adopted accelerators in HPC systems, are susceptible to transient hardware fault. New generation of GPUs feature mixed-precision architectures such as NVIDIA Tensor Cores to accelerate matrix multiplications. While being widely adapted, how would they behave under transient hardware faults remain unclear. In this study, we conduct a large-scale fault injection experiments on GEMM kernels implemented with different floating-point data types on the V100 and A100 Tensor Cores, and show distinct error resilience characteristics for the GEMMS with different formats. In the future, we plan to explore this space by building precision-aware floating-point fault tolerance techniques for applications such as DNNs that exercise low-precision computations.

Fang, Bo↗

Deterministic Design of High Precision Slicing Machine Final Report CRADA No. T-160-91-1-C (Advanced manufacturing initiative final report. Deterministic design of high precision slicing machine)

The project is designed to merge the expertise of LLNL and a US slicing machine builder in the development and production of a family of ultra-precise, slicing/grinding machines. The project will lead to the joint development of a modular family of slicers which are easily configured to a given accuracy and size. The slicers can then be profitably produced and marketed for similar precision machining applications. This project is directed towards maintaining a competitive edge for US manufacturers in the area of high precision slicing and grinding machines.

36 MATERIALS SCIENCE↗

PROBE (Precision Reflector Orbital Build Experiment): A proposed flight experiment to study EVA assembly of precision segmented reflectors

PROBE (Precision Reflector Orbital Build Experiment) is a Shuttle flight demonstration experiment designed to study extravehicular activity (EVA) assembly of precision segmented reflectors. PROBE will support missions being considered for NASA's Global Change Technology Initiative as well as other missions in astrophysics and spacecraft optical communications requiring large precision reflectors. Such reflectors are envisioned to consist of a low-mass backup truss to which the optical surface is attached. Because of their large size, these reflectors will be constructed on-orbit from smaller pieces which can be packaged in the launch vehicle. The technology to be developed with PROBE also has application for construction of solar dynamic collectors which are planned for the enhanced configuration of Space Station Freedom. Viewgraphs of PROBE are presented.

Heard, Walter↗

Improved precision and accuracy in quantifying plutonium isotope ratios by RIMS

Resonance ionization mass spectrometry (RIMS) holds the promise of rapid, isobar-free quantification of actinide isotope ratios in as-received materials (i.e. not chemically purified). Recent progress in achieving this potential using two Pu test materials is presented. RIMS measurements were conducted multiple times over a period of two months on two different Pu solutions deposited on metal surfaces. Measurements were bracketed with a Pu isotopic standard, and yielded absolute accuracies of the measured Pu-240/Pu-239 ratios of 0.7 and 0.58 %, with precisions (95 % confidence intervals) of 1.49 and 0.91 %. The minor isotope Pu-238 was also quantified despite the presence of a significant quantity of U-238 in the samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Precision Oncology and Genomically Guided Radiation Therapy: A Report From the American Society for Radiation Oncology/American Association of Physicists in Medicine/National Cancer Institute Precision Medicine Conference

To summarize important talking points from a 2016 symposium focusing on real-world challenges to advancing precision medicine in radiation oncology, and to help radiation oncologists navigate the practical challenges of precision, radiation oncology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precise Lifetime Measurements in Light Nuclei for Benchmarking Modern Ab-initio Nuclear Structure Models

A new generation of ab-initio calculations, based on realistic two- and three-body forces, is having a profound impact on our view of how nuclei work. To improve the numerical methods, and the parameterization of 3-body forces, new precise data are needed. Electromagnetic transitions are very sensitive to the dynamics which drive mixing between configurations. We have made a series of precise (< 3%) measurements of electromagnetic transitions in the A=10 nuclei {sup 10}C and {sup 10}Be by using the Doppler Shift Attenuation method carefully. Many interesting features can be reproduced including the strong α clustering. New measurements on {sup 8}Be and {sup 12}Be highlight the interplay between the alpha clusters and their valence neutrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sequential Linker Installation: Precise Placement of Functional Groups in Multivariate Metal-Organic Frameworks

A unique strategy, sequential linker installation (SLI), has been developed to construct multivariate MOFs with functional groups precisely positioned. PCN-700, a Zr-MOF with eight-connected Zr6O4(OH)(8)(H2O)(4) clusters, has been judiciously designed; the Zr-6 clusters in this MOF are arranged in such a fashion that, by replacement of terminal OH-/H2O ligands, subsequent insertion of linear dicarboxylate linkers is achieved. We demonstrate that linkers with distinct lengths and functionalities can be sequentially installed into PCN-700. Single-crystal to single-crystal transformation is realized so that the positions of the subsequently installed linkers are pinpointed via single-crystal X-ray diffraction analyses. This methodology provides a powerful tool to construct multivariate MOFs with precisely positioned functionalities in the desired proximity, which would otherwise be difficult to achieve.

Yuan, S↗

A Precision Measurement Of The Neutral Pion Lifetime: The PRIMEX Experiment

The PRIMEX collaboration at Jefferson Lab is completing an experimental analysis to obtain a precision measurement of the neutral pion lifetime. Results from the experiment will be presented and comparisons made with the chiral anomaly prediction and NLO calculations. An extension of the experiment to 12 GeV for measurements of the {eta} and {eta}' radiative widths is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Precision Measurement of the Proton Elastic Form Factor Ratio at Low Q{sup 2}

A high precision measurement of the proton elastic form factor ratio {mu}{sub p}G{sub Ep}/G{sub Mp} in the range Q{sup 2} = 0.3-0.7 GeV{sup 2}/c{sup 2} was performed using recoil polarimetry in Jefferson Lab Hall A. In this low Q{sup 2} range, previous data from LEDEX [5] along with many fits and calculations [2, 3, 4] indicate substantial deviations of the ratio from unity. In this new measurement, with 80% polarized electron beam for 24 days, we are able to achieve <1% statistical uncertainty. Preliminary results are a few percent lower than expected from previous world data and fits, indicating a smaller G{sub Ep} at this region. Beyond the intrinsic interest in nucleon structure, the improved form factor measurements also have implications for DVCS, determinations of the proton Zemach radius and strangeness form factors through parity violation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Qweak experiment: a precision measurement of the proton's weak charge

The Qweak experiment will conduct the first precision measurement of the weak charge of the proton, Q{sub W}{sup p}, at Jefferson Laboratory, building on the technical advances that have been made in the laboratory's parity-violation program and using the results of earlier measurements to constrain hadronic corrections. When the results from this measurement are combined with atomic-parity violation and other PVES measurements the weak charges of the 'up' and 'down' quarks can be extracted. The experiment is basically a measurement of the parity-violating longitudinal analyzing power in e-p elastic scattering at Q{sup 2} = 0.026 (GeV/c){sup 2} employing 150 {mu}A's of 85% polarized electrons on a 0.35 m long liquid hydrogen target. The experiment will determine the weak charge of the proton with about 4.1% combined statistical and systematic errors. This corresponds to constraints on parity violating new physics at a mass scale of 2.3 TeV at the 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision electroweak studies using parity violation in electron scattering

The nature of new neutral-current interactions can be revealed at the low-energy precision frontier, where studies of parity-violation in electron scattering will complement the energy-frontier studies at the LHC. Measurements of the parity-violating observable A{sub PV} - the cross-section asymmetry in the scattering of longitudinally polarized electrons from an unpolarized target - are sensitive to possible contact interactions from new physics at multi-TeV mass scales. The 12 GeV upgrade at JLab and a new, high-intensity beam at Mainz offer opportunities for significant improvements in measurements of electron-electron and electron-quark parity-violating interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HIGH-PRECISION PREDICTIONS FOR THE ACOUSTIC SCALE IN THE NONLINEAR REGIME

We measure shifts of the acoustic scale due to nonlinear growth and redshift distortions to a high precision using a very large volume of high-force-resolution simulations. We compare results from various sets of simulations that differ in their force, volume, and mass resolution. We find a consistency within 1.5{sigma} for shift values from different simulations and derive shift {alpha}(z) - 1 = (0.300 {+-} 0.015) %[D(z)/D(0)]{sup 2} using our fiducial set. We find a strong correlation with a non-unity slope between shifts in real space and in redshift space and a weak correlation between the initial redshift and low redshift. Density-field reconstruction not only removes the mean shifts and reduces errors on the mean, but also tightens the correlations. After reconstruction, we recover a slope of near unity for the correlation between the real and redshift space and restore a strong correlation between the initial and the low redshifts. We derive propagators and mode-coupling terms from our N-body simulations and compare with the Zel'dovich approximation and the shifts measured from the {chi}{sup 2} fitting, respectively. We interpret the propagator and the mode-coupling term of a nonlinear density field in the context of an average and a dispersion of its complex Fourier coefficients relative to those of the linear density field; from these two terms, we derive a signal-to-noise ratio of the acoustic peak measurement. We attempt to improve our reconstruction method by implementing 2LPT and iterative operations, but we obtain little improvement. The Fisher matrix estimates of uncertainty in the acoustic scale is tested using 5000 h {sup -3} Gpc{sup 3} of cosmological Particle-Mesh simulations from Takahashi et al. At an expected sample variance level of 1%, the agreement between the Fisher matrix estimates based on Seo and Eisenstein and the N-body results is better than 10%.

79 ASTRONOMY AND ASTROPHYSICS↗

Evidence for dark matter interactions in cosmological precision data?

We study a two-parameter extension of the cosmological standard model ΛCDM in which cold dark matter interacts with a new form of dark radiation. The two parameters correspond to the energy density in the dark radiation fluid Δ N fluid and the interaction strength between dark matter and dark radiation. The interactions give rise to a very weak "dark matter drag" which damps the growth of matter density perturbations throughout radiation domination, allowing to reconcile the tension between predictions of large scale structure from the CMB and direct measurements of σ 8 . We perform a precision fit to Planck CMB data, BAO, large scale structure, and direct measurements of the expansion rate of the universe today. Our model lowers the χ-squared relative to ΛCDM by about 12, corresponding to a preference for non-zero dark matter drag by more than 3σ. Particle physics models which naturally produce a dark matter drag of the required form include the recently proposed non-Abelian dark matter model in which the dark radiation corresponds to massless dark gluons.

cosmological parameters from CMB↗

Precise and accurate cosmology with CMB×LSS power spectra and bispectra

With the advent of a new generation of cosmological experiments that will provide high-precision measurements of the cosmic microwave background (CMB) and galaxies in the large-scale structure, it is pertinent to examine the potential of performing a joint analysis of multiple cosmological probes. In this paper, we study the cosmological information content contained in the one-loop power spectra and tree bispectra of galaxies cross-correlated with CMB lensing. We use the FFTLog method to compute angular correlations in spherical harmonic space, applicable for wide angles that can be accessed by forthcoming galaxy surveys. Here, we find that adding the bispectra and cross-correlations with CMB lensing offers a significant improvement in parameter constraints, including those on the total neutrino mass, M ν , and local non-Gaussianity amplitude, ƒ NL . In particular, our results suggest that the combination of the Vera C. Rubin Observatory's Legacy Survey of Space and Time (LSST) and CMB-S4 will be able to achieve σ(M ν )=42 meV from galaxy and CMB lensing correlations, and σ(M ν )=12 meV when further combined with the CMB temperature and polarization data, without any prior on the optical depth.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel PICOSEC MM prototype with 10 × 10 cm 2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below σ = 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below σ = 20 ps for an individual pad obtained with the 10 × 10 cm 2 area resistive PICOSEC MM of 20 MΩ/$\square$ showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B 4 C) photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

RETHGEM↗

Empirical fit to precision inclusive electron-proton cross sections in the resonance region

An empirical fit is described to measurements of inclusive inelastic electron-proton cross sections in the kinematic range of four-momentum transfer 0<=Q{sup 2}<8 GeV{sup 2} and final-state invariant mass 1.1<W<3.1 GeV. The fit is constrained by the recent high-precision longitudinal and transverse separated cross section measurements from Jefferson Lab Hall C, unseparated Hall C measurements up to Q{sup 2} approx =7.5 GeV{sup 2}, and photoproduction data at Q{sup 2}=0. Compared to previous fits, the present fit covers a wider kinematic range, fits both transverse and longitudinal cross sections, and features smooth transitions to the photoproduction data at Q{sup 2}=0 and deep inelastic scattering data at high Q{sup 2} and W.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗