At least 55 records · Page 3

Characterizing the Impact of GPU Power Management on an Exascale System

As GPU-accelerated high-performance computing (HPC) systems approach exascale performance, controlling energy consumption without compromising throughput is essential. Architectures such as the AMD MI250X-based Frontier supercomputer provide runtime mechanisms like frequency and power capping, enabling energy tuning without modifying application code. Although both target energy reduction, they operate via distinct hardware control paths and influence workloads differently. We present a comprehensive evaluation of these strategies on a leadership-class system using diverse HPC proxy applications representative of production workloads. Our study analyzes performance–energy trade-offs across multiple capping levels, node counts (1 and 32), and application profiles. Results show that frequency capping generally achieves higher energy efficiency and scalability, with gains of up to 13.2% without performance loss, while power capping is more effective for single-node runs or bursty GPU utilization. We also provide practical guidelines to help system administrators and users balance energy efficiency and performance in large-scale scientific workloads.

Costa, Mariana [Universidade Federal do Rio Grande↗

Managing Solar Photovoltaic Integration in the Western United States: Power System Flexibility Requirements and Supply

As penetrations of variable renewable energy generation technologies such as wind and solar photovoltaics (PV) continue to increase across the United States, greater uncertainty and variability in the net load often lead to a concern about how power systems may adapt. Managing the system net load (i.e., load minus contribution from variable generation technologies) may become more challenging with increasing variable generation, as the magnitude and frequency of net ramps increase. However, there is inherent flexibility in power systems through the conventional generator fleet (under least-cost unit commitment and economic dispatch), less-conventional generation sources (e.g., storage, demand response, concentrating solar power with thermal energy storage), and imports and exports with neighbors. In this analysis, we create an open-source tool to analyze the flexibility of the results of a specific commercial unit commitment and economic dispatch tool (PLEXOS), but the code can be applied generically as well. The tool assesses the flexibility requirements (or demand) of a system through a net load analysis. The constraints and limitations of each generator are then considered to determine the availability (or supply) of flexibility. Then, the supply and demand of flexibility are compared to gain a more complete picture of potential flexibility concerns. We apply this open-source tool to high-penetration PV scenarios constructed for three focus regions in the western United States defined using the Resource Planning Model (RPM) capacity expansion modeling tool: RPM-OR, RPM-CO, and RPM-AZ. Generally, we find few flexibility concerns, as the western United States represents a large and interconnected power system with significant inherent flexibility. In addition, the PV scenarios we analyzed are overbuilt on capacity, leaving plenty of ramping ability on the system. We do find that for each focus region, the impact of imports on meeting ramping needs is essential. This means the PV integration in each focus region impacts the entire rest of the system. Each system has different dominant sources of flexibility. The conventional generator fleet (especially coal and gas combined-cycle technologies) as well as less-conventional sources such as storage are all shown to be important sources of flexibility. The scenarios evaluated here were designed to study the planning and operations impact of high solar penetration in each of three focus regions. However, none of the three focus regions likely will deploy PV in isolation, meaning the ability of imports and exports to provide flexibility may be considerably different in scenarios with strong PV deployment in every region. Overall, we intend that the framework we present here will be useful in future analysis of other system evolutions to identify whether and how flexibility may constrain the successful deployment of variable generation technologies.

14 SOLAR ENERGY↗

Evaluating adaptive and predictive power management strategies for optimizing visualization performance on supercomputers

Power is becoming an increasingly scarce resource on the next generation of supercomputers, and should be used wisely to improve overall performance. One strategy for improving power usage is hardware overprovisioning, i.e., systems with more nodes than can be run at full power simultaneously without exceeding the system-wide power limit. With this study, we compare two strategies for allocating power throughout an overprovisioned system – adaptation and prediction – in the context of visualization workloads. While adaptation has been suitable for workloads with more regular execution behaviors, it may not be as suitable on visualization workloads, since they can have variable execution behaviors. This study considers a total of 104 experiments, which vary the rendering workload, power budget, allocation strategy, and node concurrency, including tests processing data sets up to 1 billion cells and using up to 18,432 cores across 512 nodes. Overall, we find that prediction is a superior strategy for this use case, improving performance up to 27% compared to an adaptive strategy.

97 MATHEMATICS AND COMPUTING↗

Enhancing Power Resilience for Remote Communities: A Comprehensive Renewable Energy Solution for Itbayat Island

The island of Itbayat, Philippines, faces significant challenges in maintaining a reliable and resilient power supply due to its current reliance on a vulnerable power distribution system managed by a local electric cooperative. The existing infrastructure, which includes diesel generators and a radial network configuration with some above-ground lines, is highly susceptible to frequent typhoons and adverse weather conditions. These factors, combined with inadequate staffing and high operational costs, result in frequent power outages that disrupt daily life and hinder economic development. This white paper proposes a comprehensive solution to enhance the resilience and reliability of Itbayat's power system by integrating renewable energy sources, specifically solar photovoltaic (PV) systems, battery storage, and a microgrid controller. The proposed solution aims to reduce dependency on diesel fuel, optimize energy use, and provide a sustainable and robust power supply for the island. Key components of the solution include: 1. Solar PV Installation: Deploying solar PV panels to harness abundant solar energy, reducing reliance on diesel fuel. 2. Battery Storage Systems: Installing battery storage to store excess solar energy and ensure a continuous power supply during low solar generation periods. 3. Microgrid Controller: Implementing a microgrid controller to manage and optimize the integration of solar PV, battery storage, and existing diesel generators. The proposed solution addresses several critical issues, including system vulnerability, generator dependency, and operational inefficiencies. By adopting this innovative approach, Itbayat Island can achieve a more resilient, efficient, and sustainable energy infrastructure, ensuring a stable power supply for its residents and enhancing overall energy security.

14 SOLAR ENERGY↗

How Improved Forecasting Can Increase the Bulk Power System Value of Price-Responsive Electric Vehicle Managed Charging

Personal light-duty vehicle (LDV) electric vehicle managed charging (EVMC) can reduce power system costs by better aligning electric vehicle (EV) charging with locations and times of low energy cost or infrastructure use. The need to coordinate charging demand across thousands to millions of vehicles while preserving mobility service is a barrier to realizing the value of EVMC. Price-responsive dispatch mechanisms like time-of-use rates (TOU) and hourly real-time prices (RTP) are attractive compared to direct load control (DLC) because they only require one-way communications and local controls. However, increasing participation in price responsive mechanisms can induce costly-to-serve spikes in load and otherwise increase, rather than decrease, production costs. We quantify the ability of improved EVMC forecasting to sustain savings from price responsive mechanisms beyond the limit of 14% of LDVs actively participating observed in previous work. Perfect forecasting of price-responsive EV load makes TOU and RTP value-competitive with a low-error DLC formulation with up to 27% (within-week flexibility) to 45% or more (within-session flexibility) of LDVs participating in EVMC in an envisioned New England power system with 84% clean energy. Additional costs of implementing DLC should be no more than tens of dollars per vehicle-year if DLC is to be value-competitive with accurately forecast price-responsive EVMC for double-digit percentage shares of LDVs participating.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Substation Secondary Asset Health Monitoring and Management System (SSHM)

Electric Power Group, LLC (EPG) was awarded DOE OE0000850 to design, develop, and demonstrate a real-time software application for substation secondary equipment health monitoring and management at host utility American Electric Power (AEP), a cost share partner. This project addresses the need for monitoring substation equipment health and providing operators with tools to identify and take pre-emptive action to avoid catastrophic equipment failure. By monitoring synchrophasor data in real time, data anomalies that indicate potential asset failure can be detected and alerts can be sent to operators in time to take corrective actions. EPG developed two data driven algorithms to identify abnormal equipment signature patterns as well as a method using substation linear state estimation (SLSE). The software has been deployed on hardened PC’s and tested and validated for cost share partner AEP’s substations - 138kV and 765 kV. The SSHM software has been accepted by AEP and final demonstration of DOE - OE0000850 for AEP and DOE was successfully completed on March 17th, 2020. EPG developed the Substation Secondary Asset Health Monitoring (SSHM) Platform to analyze equipment failure signatures in PMU data and alert substation personnel when pre-emptive inspection, repairs and other actions are warranted to prevent potential catastrophic failures. This is the first system that automatically monitors the health of substation secondary assets and alerts users to emerging failures using synchrophasor measurements. SSHM uses high resolution PMU data from PTs, CTs, and CCVTs to analyze equipment signatures and identify anomalies that are precursor indicators of potential equipment failure. When an anomaly is detected, there is a likelihood of potential failure of monitored equipment, the system alerts the user with visual alarms including alarm trend charts and indicator lights on a oneline diagram of the substation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Load Switching Group based Feeder-level Microgrid Energy Management Algorithm for Service Restoration in Power Distribution System

This paper presents a load switching group based energy management system (LSG-EMS) for operating microgrids on a distribution feeder powered by one or multiple grid-forming distributed energy resources. Loads on a distribution feeder are divided into load switching groups that can be remotely switched on and off. The LSG-EMS algorithm, formulated as a mixed-integer linear programming (MILP) problem, has an objective function of maximizing the served loads while minimizing the total number of switching actions. A new set of topology constraints are developed for allowing multiple microgrids to be formed on the feeder and selecting the optimal supply path. Customer comfort is accounted for by maximizing the supply duration in the customer preferred service period and enforcing a minimum service duration. The proposed method is demonstrated on a modified IEEE 33-bus system using actual customer data. Simulation results show that the LSG-EMS successfully coordinates multiple grid-forming sources by selecting an optimal supply topology that maximizes the supply period of both the critical and noncritical loads while minimizing customer service interruptions in the service restoration process.

Hu, Rongxing↗

Self-regulating power management for a neural network system

A neural network runs a known input data set using an error free power setting and using an error prone power setting. The differences in the outputs of the neural network using the two different power settings determine a high level error rate associated with the output of the neural network using the error prone power setting. If the high level error rate is excessive, the error prone power setting is adjusted to reduce errors by changing voltage and/or clock frequency utilized by the neural network system. If the high level error rate is within bounds, the error prone power setting can remain allowing the neural network to operate with an acceptable error tolerance and improved efficiency. The error tolerance can be specified by the neural network application.

Kegel, Andrew G.↗

Self-regulating power management for a neural network system

A neural network runs a known input data set using an error free power setting and using an error prone power setting. The differences in the outputs of the neural network using the two different power settings determine a high level error rate associated with the output of the neural network using the error prone power setting. If the high level error rate is excessive, the error prone power setting is adjusted to reduce errors by changing voltage and/or clock frequency utilized by the neural network system. If the high level error rate is within bounds, the error prone power setting can remain allowing the neural network to operate with an acceptable error tolerance and improved efficiency. The error tolerance can be specified by the neural network application.

Kegel, Andrew G.↗

Electric Vehicle Managed Charging: Estimating the Potential Bulk Power System Value

With more and more electric vehicles (EVs) on the road, the grid of the future can greatly benefit from EV managed charging, which coordinates charging based on people's travel needs, electricity supply, and grid conditions. The added flexibility could be especially valuable for the bulk power system as it transitions to high shares of variable renewable generation, like wind and solar. Numerous studies have estimated the potential value of EV managed charging. In this study, NREL leveraged more detailed modeling of EV adoption, use, charging, and bulk power system operations to understand the potential value. Unique to this study, NREL modeled different charging flexibility types and dispatch mechanisms - as well as participation rates among drivers in having their EV charging managed - starting from vehicle-specific descriptions of charging flexibility. The study is based on a passenger light-duty vehicle adoption scenario with 100% EV sales by 2035 and a New England power system in 2038 with 84% clean generation and 26% of the electric load met by net imports. The 2038 New England light-duty vehicle feet is modeled as 45% electric.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advance Distribution Management System (ADMS)

This presentation explores the transition from traditional distribution management systems to Advanced Distribution Management Systems (ADMS) as a foundation for smart grid development. It highlights the key benefits of ADMS, including enhanced reliability, improved operational efficiency, and increased situational awareness. The presentation also addresses common implementation challenges such as system integration, data management, and organizational readiness. It concludes with a forward-looking perspective on the evolving role of ADMS and essential takeaways for utilities and stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synthetic residential load models for smart city energy management simulations

The ability to control tens of thousands of residential electricity customers in a coordinated manner has the potential to enact system-wide electric load changes, such as reduce congestion and peak demand, among other benefits. To quantify the potential benefits of demand-side management and other power system simulation studies (e.g. home energy management, large-scale residential demand response), synthetic load datasets that accurately characterize the system load are required. This study designs a combined top-down and bottom-up approach for modelling individual residential customers and their individual electric assets, each possessing their own characteristics, using time-varying queueing models. The aggregation of all customer loads created by the queueing models represents a known city-sized load curve to be used in simulation studies. The three presented residential queueing load models use only publicly available data. An open-source Python tool to allow researchers to generate residential load data for their studies is also provided. The simulation results presented consider the ComEd region (utility company from Chicago, IL) and demonstrate the characteristics of the three proposed residential queueing load models, the impact of the choice of model parameters, and scalability performance of the Python tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AI-Guided Reasoning-Based Operator Support System for the Nuclear Power Plant Management

The Decision-making process in the Nuclear Power Plant (NPP) control room faces some challenges: operator incomplete knowledge, insufficient time for responding to the highly dynamic events, and a large number of indicators to monitor. Because of the complexity of the NPP system, it is hard to pre-plan all the failures/mitigative actions. An intelligent operator support system is vital to mitigate these shortcomings. In this paper, an AI declarative approach (Answer Set Programming (ASP)) is employed to represent our knowledge of the nuclear power plant in the form of logic rules. This represented knowledge is structured to form a reasoning-based operator support system. When an incident occurs, this ASP-based reasoning support system is demonstrated to be capable of fault identification (diagnosis), informing the operator of different scenarios and consequences, and generating the control options (decision making).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Integrating Parabolic Trough Solar Fields Into Computerized Maintenance Management Systems

Computerized maintenance management systems for power plants are not well suited for application in solar fields. They work well for tracking maintenance requirements on the hundreds or even thousands of pieces of equipment in conventional power plants, but they do not work as well tracking the maintenance requirements on hundreds of thousands of identical pieces of equipment found in a solar field. A database application, known as a field status program, is being developed for tracking the maintenance and status of collectors and components in parabolic trough solar fields as a complement to the computerized maintenance management system. This system, patterned after a similar system developed by the KJC Operating Company in the 1990s, provides a valuable tool for the O&M of parabolic trough solar fields. This paper describes the development and application of the tool and the new expanded capabilities that are being added to further enhance the O&M of solar fields.

Price, Hank↗

Managing Increased Electric Vehicle Shares on Bulk Power Systems

The convergence of transportation electrification, other load growth, and the integration of many power sector technologies presents a complex planning problem requiring realistic, region-specific modeling and analysis to ensure the power system can support new loads quickly and affordably.

33 ADVANCED PROPULSION SYSTEMS↗

Control systems and data management for high-power laser facilities

The next generation of high-power lasers enables repetition of experiments at orders of magnitude higher frequency than what was possible using the prior generation. Facilities requiring human intervention between laser repetitions need to adapt in order to keep pace with the new laser technology. A distributed networked control system can enable laboratory-wide automation and feedback control loops. These higher-repetition-rate experiments will create enormous quantities of data. A consistent approach to managing data can increase data accessibility, reduce repetitive data-software development and mitigate poorly organized metadata. An opportunity arises to share knowledge of improvements to control and data infrastructure currently being undertaken. We compare platforms and approaches to state-of-the-art control systems and data management at high-power laser facilities, and we illustrate these topics with case studies from our community

47 OTHER INSTRUMENTATION↗