Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Controlling a power output of a nuclear reaction without control rods

A nuclear power system includes a reactor vessel that includes a reactor core that includes nuclear fuel assemblies configured to generate a nuclear fission reaction. A representative nuclear power system further includes a riser positioned above the reactor core and a primary coolant flow path that extends from a bottom portion of the reactor vessel, through the reactor core, and through an annulus between the riser and the reactor vessel. A primary coolant circulates through the primary coolant flow path to receive heat from the nuclear fission reaction and release the heat to a power generation system configured to generate electric power. The nuclear power system further includes a control rod assembly system positioned in the reactor vessel and configured to position control rods in only two discrete positions.

Callaway, Allyson↗

Verifying the Computational Integrity of Power Grid Controls with Zero-Knowledge Proof

The control of future power grids is migrating from a centralized to a distributed/decentralized scheme to enable a massive penetration of distributed energy resources with rising dependence on communication infrastructure. A common assumption made for most existing distributed/decentralized controllers is that local controllers would faithfully follow the designated controller dynamics based on the data received from communication channels. However, with increased probability of cyberattacks on Operational Technology infrastructure, such an assumption could be risky because proper execution of the controller dynamics is then built on trust in secure communication and computation. In this work, we leverage a cryptography technology known as zero-knowledge scalable transparent arguments of knowledge (zk-STARK) to verify the computational integrity of power grid control algorithms, with projected linear dynamics-based control schemes as the initial proof-of-concept test case. The method presented here converts the cybersecurity challenge of data integrity for grid control into a subset of computational integrity.

computational integrity↗

Controlling a power output of a nuclear reactor without using control rods

A nuclear power system includes a reactor vessel that includes a reactor core that includes nuclear fuel assemblies configured to generate a nuclear fission reaction. A representative nuclear power system further includes a riser positioned above there actor core and a primary coolant flow path that extends from a bottom portion of the reactor vessel, through the reactor core, and through an annulus between the riser and the reactor vessel. A primary coolant circulates through the primary coolant flow path to receive heat from the nuclear fission reaction and release the heat to a power generation system configured to generate electric power. The nuclear power system further includes a control rod assembly system positioned in the reactor vessel and configured to position control rods in only two discrete positions.

Callaway, Allyson↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems: Preprint

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

From MAST-U to STEP: Power exhaust control challenges and opportunities

This work explores the challenges and opportunities for power exhaust control in STEP, informed by dedicated MAST-U experiments. The STEP system primarily relies on hydrogenic and argon gas injection into the divertors, compensating for transients originating in the plasma core. Fast transients (>10 Hz) that evolve too quickly for actuators to compensate must be absorbed passively; the enhanced transient buffering of the foreseen long-legged divertor provides a clear advantage over conventional geometries, as demonstrated in the MAST-U Super-X divertor. Experiments further indicate that STEP’s tight divertor baffling enables near-independent control of the upper and lower divertors. The most challenging transients are expected from power-sharing fluctuations, as MAST-U experiments observed extremely fast dynamics. Fluctuations from core pellet fuelling remain relatively benign due to the small pellet size according to simulations. Exhaust control in a reactor like STEP requires an integrated approach befitting its machine-critical nature. A predictive control element, integrated with core plasma control, allows pre-emptive preparation of the divertor for incoming transients. An observer-based diagnostic approach is foreseen to monitor the divertor in the challenging reactor environment, supported by an extended diagnostic set in the non-nuclear phase to validate the required dynamic models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wind turbine power phase control with DC collection bus for onshore/offshore windfarms

A DC bus collection system for a wind farm reduces the overall required number of converters and minimizes the energy storage system requirements. The DC bus collection system implements a power phasing control method between wind turbines that filters the variations and improves power quality. The phasing control method takes advantage of a novel power packet network concept with nonlinear power flow control design techniques that guarantees both stable and enhanced dynamic performance.

Weaver, Wayne W.↗

Automated power-following control for nuclear thermal propulsion startup and shutdown using MOOSE-based applications

This paper describes an investigation of various automated control strategies applied to a full-core multiphysics Griffin/Bison/RELAP-7 model of a prototypical nuclear thermal propulsion system. In all cases, control is achieved by actuating control drums based on the demanded power and predicted quantities from the numerical model. One key finding is that hybrid proportional integral derivative controllers – a novel type of controller that uses both power and reactivity predicted signals – can demonstrate a level of performance rivaling that of period-generated control. The former requires parameter tuning, while the latter mostly necessitates providing reactivity coefficients and temperature rates of change, which could be very challenging to accurately measure in real-time. In addition, decay heat plays an important role in determining cooling requirements during cooldown phases. A decay heat model, accounting for burn time and throttling, was derived, and is incorporated within the model to simulate the steady-state and shutdown phases and satisfyingly follow the power demand. However, temperature overshoots and non-constant specific impulse during throttling will necessitate further improvements.

33 ADVANCED PROPULSION SYSTEMS↗

Quantum Reinforcement Learning for Volt-VAR Control in Power Distribution Systems

Volt-VAR control (VVC) is crucial in active distribution networks for optimizing voltage profiles and minimizing network losses. While traditional deep reinforcement learning (DRL) algorithms exhibit promise for VVC, they often require extensive computational resources to handle such a high-dimensional problem. As a potential solution, quantum reinforcement learning (QRL) algorithms integrate the computational capabilities of quantum computing into the DRL framework. However, existing QRL algorithms struggle with complex VVC problems due to the limitations of current quantum hardware. To bridge this gap, this paper proposes an innovative QRL algorithm featuring an end-to-end architecture that integrates a classical autoencoder, variational quantum circuits (VQCs), and classical post-processing layers. This design efficiently compresses high-dimensional grid states, enabling VQCs to leverage quantum advantages while producing multiple control device outputs tailored for VVC tasks. Numerical studies on three representative distribution systems verify the effectiveness and scalability of the proposed QRL algorithm, and demonstrate its enhanced performance over classical approaches with only approximately 1% of the parameters. Additionally, the robustness of our developed algorithm is validated through noisy quantum environments.

97 MATHEMATICS AND COMPUTING↗

Human Factors Challenges in Modernizing Nuclear Power Plant Control Rooms

Jeffrey Joe has been invited to give a presentation entitled, “Human Factors Challenges in Modernizing Nuclear Power Plant Control Rooms,” at the 2024 Human Systems Symposium. Experts conducting human factors and human systems research will gather and share research at this conference. This conference is a good opportunity to develop new business for INL via research collaborations, as attendees exchange knowledge and explore the latest trends, advancements, and challenges in the field of human systems research across the DOE national laboratories.

99 GENERAL AND MISCELLANEOUS↗

Control of power converters having integrated capacitor blocked transistor cells

Various examples of power converters including Integrated Capacitor Blocked Transistor (ICBT) cells and methods of control of power converters having ICBT cells are described. In one example, a power converter includes an upper arm including a plurality of upper ICBT cells connected in series to form a series connection path and a lower arm including a plurality of lower ICBT cells connected in series in the series connection path. A controller can be configured to provide a control signal pair to each of the upper ICBT cells and a complementary control signal pair to each of the lower ICBT cells to control the converter output. A capacitor voltage controller can be configured to balance a voltage potential among ICBT capacitors in at least one of the upper arm and the lower arm.

Yu, Jianghui↗

Control approach for power modulation of end-use loads

Methods, apparatus, and systems are disclosed herein for power modulation control of power grids using end-use loads. At the beginning of a coordination period typically lasting a few minutes, a population of end-use loads (water heaters, air conditioners, plug-in electric vehicles, etc.) is interrogated for their willingness to participate in power modulation by undergoing state transitions from on to off, or off to on. Distribution system flexibilities are calculated from the sums of device powers within distribution systems. Area flexibilities are calculated from the sums of device powers within areas. Thresholds for various devices to change state in response to inter-area oscillation damping or frequency regulation are derived from these flexibilities. Two power functions are monitored in real-time and compared with the device thresholds to trigger state changes which then remain locked throughout the remainder of the coordination period, then the devices are released from the lockout state.

Lian, Jianming↗

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recent Advances in Precision Clock Synchronization Protocols for Power Grid Control Systems

With the advent of a new Precision Time Protocol specification, new opportunities abound for clock synchronization possibilities within power grid control systems. The third iteration of the Institute of Electrical and Electronics Engineers Standard 1588 specification provides several new features specifically aimed at complex, wide-area deployments in which situational awareness and control require precise time agreement. This paper describes the challenges faced by existing technology, introduces the new time distribution specification, and provides examples to explain how it represents a game-changing innovation.

24 POWER TRANSMISSION AND DISTRIBUTION↗