Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Strategies for Continuous Balancing in Future Power Systems with High Wind and Solar Shares

The use of wind power has grown strongly in recent years and is expected to continue to increase in the coming decades. Solar power is also expected to increase significantly. In a power system, a continuous balance is maintained between total production and demand. This balancing is currently mainly managed with conventional power plants, but with larger amounts of wind and solar power, other sources will also be needed. Interesting possibilities include continuous control of wind and solar power, battery storage, electric vehicles, hydrogen production, and other demand resources with flexibility potential. The aim of this article is to describe and compare the different challenges and future possibilities in six systems concerning how to keep a continuous balance in the future with significantly larger amounts of variable renewable power production. A realistic understanding of how these systems plan to handle continuous balancing is central to effectively develop a carbon-dioxide-free electricity system of the future. The systems included in the overview are the Nordic synchronous area, the island of Ireland, the Iberian Peninsula, Texas (ERCOT), the central European system, and Great Britain.

14 SOLAR ENERGY↗

Lowering the reactor breakeven requirements for proton–boron 11 fusion

Recently, it has been shown that altering the natural collisional power flow of the proton–boron 11 (pB11) fusion reaction can significantly reduce the Lawson product of ion density and confinement time required to achieve ignition. However, these products are still onerous—on the order of 7×1015 cm−3 s under the most optimistic scenarios. Fortunately, a breakeven fusion power plant does not require an igniting plasma, but rather a reactor that produces more electrical power than it consumes. Here, we extend the existing 0D power balance analysis to check the conditions on power plant breakeven. We find that even for the base thermonuclear reaction, modern high-efficiency thermal engines should reduce the Lawson product to 1.2×1015 cm−3 s. We then explore the impact of several potential improvements, including fast proton heating, alpha power capture, direct conversion, and efficient heating. We find that such improvements could reduce the required Lawson product by a further order of magnitude, bringing aneutronic fusion to target ITER ion densities and confinement times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Optimal Dispatch of Energy Systems with Intermittent Renewables and Damage Model

With the increasing penetration of intermittent renewable energy sources into the grid, there is a growing need for process systems-based strategies that integrate dispatchable and variable energy systems for supplying the demand while maintaining grid reliability. The proposed framework corresponds to a dynamic mixed-integer linear programming optimization approach that integrates coal-fired and natural gas-fired power plants, NaS batteries for energy storage, and solar/wind energy to supply the demand. This optimization approach considers an economic goal and constraints to provide power balance while maintaining the overall damage of the natural gas combined cycle (NGCC) power plant drum under a maximum stress as well as avoiding the overheating of the NGCC superheater and reheater. Renewable curtailment levels are also retained at minimum levels. Case studies are analyzed considering different loads and renewable penetration levels. The results show that the demand was met for all cases. Grid flexibility was mostly provided by the NGCC, while the batteries were used sparingly. In addition, considering a CO 2 equivalent analysis, the environmental performance was intrinsically connected to grid flexibility and the level of renewable penetration. Stress analysis results reinforced the necessity for an equipment health-related constraint.

97 MATHEMATICS AND COMPUTING↗

Isotope dependence of the type I ELMy H-mode pedestal in JET-ILW hydrogen and deuterium plasmas

The pedestal structure, edge transport and linear MHD stability have been analyzed in a series of JET with the ITER-like wall hydrogen (H) and deuterium (D) type I ELMy H-mode plasmas. The pedestal pressure is typically higher in D than in H at the same input power and gas rate, with the difference mainly due to lower density in H than in D (Maggi et al (JET Contributors) 2018 Plasma Phys. Control. Fusion 60 014045). A power balance analysis of the pedestal has shown that higher inter-ELM separatrix loss power is required in H than in D to maintain a similar pedestal top pressure. This is qualitatively consistent with a set of interpretative EDGE2D-EIRENE simulations for H and D plasmas, showing that higher edge particle and heat transport coefficients are needed in H than in D to match the experimental profiles. It has also been concluded that the difference in neutral penetration between H and D leads only to minor changes in the upstream density profiles and with trends opposite to experimental observations. This implies that neutral penetration has a minor role in setting the difference between H and D pedestals, but higher ELM and/or inter-ELM transport are likely to be the main players. The interpretative EDGE2D-EIRENE simulations, with simultaneous upstream and outer divertor target profile constraints, have indicated higher separatrix electron temperature in H than in D for a pair of discharges at low fueling gas rate and similar stored energy (which required higher input power in H than in D at the same gas rate). The isotope dependence of linear MHD pedestal stability has been found to be small, but if a higher separatrix temperature is considered in H than in D, this could lead to destabilization of peeling-ballooning modes and shrinking of the stability boundary, qualitatively consistent with the reduced pedestal confinement in H.

08 HYDROGEN↗

Evolutionary Game Dynamics between Distributed Energy Resources and Microgrid Operator: Balancing Act for Power Factor Improvement

This article investigates the intricate dynamics between Distributed Energy Resources (DERs) and the Microgrid Operator (MGO) within a microgrid interconnected with the main grid. Employing an evolutionary game framework, the study scrutinizes the strategic evolution of DERs’ decision-making processes in their interactions with the MGO. Modeled as an evolutionary game, these interactions encapsulate the strategies adopted by DERs, resulting in stable equilibrium strategies over time. Motivated by direct benefits linked to increased active power production, DERs strive to sell all available power, while the MGO focuses on optimizing the microgrid’s overall performance. The study assesses the microgrid’s performance in terms of its power factor, emphasizing the strategic balance DERs must achieve in their active power generation to avoid penalization. This penalization results in decreased individual utility for DERs due to the overall power factor decrease resulting from their prioritization of active power generation. Additionally, the diminished overall power factor implies a decrease in MGO utility. The individual utility of each DER is further influenced by the strategies adopted by other DERs, impacting the penalization factor. Leveraging a modified IEEE 13-node distribution microgrid consisting of three DERs, the study presents case studies encompassing both cooperative and non-cooperative evolutionary game scenarios. These case studies illuminate the intricacies of interactions and the resulting equilibrium outcomes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Two-fluid model of rf current condensation in magnetic islands

The stabilization of tearing modes with rf waves is subject to a nonlinear effect, termed rf current condensation, that has the potential to greatly enhance and localize current driven within magnetic islands. Here we extend previous investigations of this effect with a two fluid model that captures the balance of diffusive and thermal equilibration processes within the island. We show that the effective power and resulting strength of the condensation effect can be greatly enhanced by avoiding collisional heat loss to the ions. The relative impact of collisions on the overall power balance within the island depends on the ratio of the characteristic diffusion timescale and the electron–ion equilibration time, rather than the latter alone. Although relative heat loss to ions increases with island size, the heating efficiency does as well. In particular, we show that the latter safely dominates for large deposition profiles, as is typically the case for lower hybrid current drive. This supports the possibility of passive stabilization of neoclassical tearing modes without the precise aiming of the rf waves required for electron cyclotron current drive stabilization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operability of a Power System with Synchronous Condensers and Grid-Following Inverters

Growing shares of inverter-based resources gener-ally correlate with a reduction in inertia as synchronous genera-tors are displaced. Along the path to high shares of inverter-based resources, in particular with only conventional grid-following inverter controls, a proffered solution is the use of synchronous condensers as a source of inertia to maintain the frequency-power balance relationship. An outstanding question is whether only grid-following inverters and synchronous condensers yield a viable power system; i.e., all frequency response is derived from inverters. A validated electromagnetic transient model of the Maui system, with many nonlinear elements such as load-shedding, line tripping, and inverter ride through criteria disabled, is used to investigate the stability of such a system. Two types of perturbations were applied, a 15% generation loss and a fault event, and it was found that the system remains stable.

grid-following inverters↗

Observation of second harmonic electron cyclotron resonance heating and current-drive transition during non-inductive plasma start-up experiment in QUEST

Here, noninductive plasma current start-up using 2nd harmonic electron cyclotron resonance heating (ECRH) with oblique radio frequency (RF) injection is demonstrated in a Q-shu University experiment with steady-state spherical tokamak. A strong transition was observed in the heating and plasma current ramp-up. The initial bulk electron heating regime exhibits T ebulk ~ 140 eV and no hard x-ray (HXR) emission with a low I p of ~15 kA; it abruptly transitions to a regime that exhibits a low T ebulk of ~10 eV and a strong HXR emission with a high I p of ~50 kA. This behavior is distinctly different from that observed in previous fundamental ECRH experiments. The mechanism of the heating and current drive transition are investigated considering wave power absorption and plasma power balance. The results indicate that the transition is caused by the favorable heating of tail electrons where the RF power absorption at the 2nd harmonic increases nearly linearly with T etail , while the power transfer from the tail electrons to the bulk electrons decreases with 1/T etail 0.5 . This causes a rapid transition to a state with high T etail while reducing T ebulk towards colder ion temperature. The understanding of the transition mechanism helps to consider plasma current start-up using 2nd harmonic ECRH for tokamak reactors such as JT-60 SA and ITER.

QUEST↗

Divertor characterization and access to dissipative divertor conditions in negative triangularity discharges in DIII-D

Reduced radial transport, short midplane-to-target parallel connection lengths, and a strong effect of cross-field drifts were responsible for the high densities required for detachment in strong negative triangularity (NT) configurations in DIII-D. Dissipative divertor conditions were achieved in NT discharges at different triangularity, injected power, plasma current, and toroidal field direction. Differences between negative and positive triangularity (PT) discharges are analyzed in this paper to understand the requirements for access to detached divertor conditions: power balance, geometry, radial transport and effect of cross-field particle drifts. Parametric dependencies of access to detachment on plasma current and power flowing into the scrape-off layer remained similar in negative and PT and impurity seeding was observed to reduce the density needed to detach by up to 30% at the expense of core impurity dilution. The impact of triangularity on core-edge integration was tested varying bottom triangularity at fixed top triangularity. The high density needed to detach was not intrinsic to the NT edge as shapes with positive lower triangularity and negative upper triangularity were able to detach at lower upstream densities while maintaining an ELM-free NT edge. Confinement degradation at deeper detachment levels was however observed in all NT shapes, often associated with radiation instabilities.

detachment↗

Advancing Understanding of Geothermal Representation in the Power Sector to Accelerate Deployment

Driven mostly by decarbonization goals, geothermal interest in the US power sector has grown considerably, gradually evolving from being considered a niche technology, to being recognized as a viable source of clean, baseload, grid-balancing power, and renewable electric power generation. Furthermore, recent technical advances that could greatly accelerate deployment in the near future, and US federal incentives for low-carbon generation technologies, including geothermal, can enable opportunities for integrating geothermal into utilities resource planning portfolios. However, in general, utilities do not have in-house expertise to evaluate geothermal technologies and its potential role in helping decarbonize the grid as well as help them achieve their individual decarbonization goals. To date, geothermal is rarely included in Capacity Expansion Models (CEM) which utilities use in their planning activities and resource/technologies prioritization. To this end, EPRI and NREL are working together in a DOE-GTO funded research project to improve geothermal understanding (opportunities, value, risks) among the power industry to help accelerate geothermal deployment. In the present paper we describe the approach and preliminary findings of this work, focused on two topics: 1) Expand the degree of understanding on the value, opportunity, and risk of geothermal technologies among utilities and related companies/groups, specifically around geothermal for power generation. 2) Improve representation of geothermal power technologies in capacity expansion models (CEM).

capacity expansion models↗

Reassessing energy deposition for the ITER 5 MA vertical displacement event with an improved DINA model

The beryllium (Be) main chamber wall interaction during a 5 MA/1.8 T upward, unmitigated VDE scenario, first analysed in [J. Coburn et al., Phys. Scr. T171 (2020) 014076] for ITER, has been re-evaluated using the latest energy deposition analysis software. Updates to the DINA disruption model are summarized, including an improved numerical convergence for the 0D power balance, limitations on the safety factor within the plasma core, and the choice to maintain a constant plasma +halo poloidal cross-section. Such updates result in a broad halo region and higher radiated power fractions compared to previous models. The new scenario lasts for ~75 ms and deposits ~29 MJ of energy, with the radial distribution of parallel heat flux q‖(r)resembling an exponential falloff with an effective λ_q=75-198 mm. A maximum halo width w_h of 0.52 m at the outboard midplane is observed. SMITER field line tracing and energy deposition simulations calculate a q_{⊥,max} of ~83 MW/m^2 on the upper first wall panels (FWP). Heat transfer calculations with the MEMOS-U code show that the FWP surface temperature reaches ~1000 K, well below the Be melt threshold. Variations of this 5 MA scenario with Be im-purity densities from 0 to 3∙10^19 m^-3 also remain below the melt threshold despite differences in energy deposition and duration. These results are in contrast to the early study which predicted melt damage to the first wall [J. Coburn et al., Phys. Scr. T171 (2020) 014076], and emphasize the importance of accurate models for the halo width w_h and the heat flux distribution q‖(r)within that halo width. The 2020 halo model in DINA has been compared with halo current experiments on COMPASS, JET, and Alcator C-Mod, and the preliminary results build confidence in the broad halo width predictions. Results for the 5 MA VDE are compared with those for a 15 MA equivalent, generated using the new DINA model. At the higher current, significant melting of the upper FWP is to be expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion heating in the PISCES-RF liquid-cooled high-power, steady-state, helicon plasma device

Radio frequency (RF) driven helicon plasma sources are commonly used for their ability to produce high-density argon plasmas ( n > 10 19 m -3 ) at relatively moderate powers (typical RF power < 2 kW). Typical electron temperatures are <10 eV and typical ion temperatures are <0.6 eV. A newly designed helicon antenna assembly (with concentric, double-layered, fully liquid-cooled RF-transparent windows) operates in steady-state at RF powers up to 10 kW. We report on the dependence of argon plasma density, electron temperature and ion temperature on RF power. At 10 kW, ion temperatures >2 eV in argon plasmas are measured with laser induced fluorescence, which is consistent with a simple volume averaged 0D power balance model. 1D Monte Carlo simulations of the neutral density profile for these plasma conditions show strong neutral depletion near the core and predict neutral temperatures well above room temperatures. The plasmas created in this high-power helicon source (when light ions are employed) are ideally suited for fusion divertor plasma-material interaction studies and negative ion production for neutral beams.

Physics↗

Envisioning the Future Renewable and Resilient Energy Grids—A Power Grid Revolution Enabled by Renewables, Energy Storage, and Energy Electronics

Today’s power grids are facing tremendous challenges because of the ever-increasing power demand, system complexity, infrastructure cost, knowledge base, and policy and regulatory issues to achieve supply–demand power balance and resiliency with respect to more frequent extreme weather events and cyberattacks. It is particularly challenging when the transition toward 100% intermittent renewable energy sources is considered. Many countries are calling for building up more transmission and distribution lines to increase power delivery capacities. This article is an attempt to answer two urgent questions: Is more transmission and distribution infrastructure really needed to meet the increasing power demand? What kind of future grid infrastructure should we envision and build? This article attempts to answer these questions and proposes the concept of community-centric asynchronous renewable and resilient energy grids. By clearly differentiating the concepts of grid resilience and reliability, the importance of building resilient power electronics’ devices and robust system-level control algorithms to achieve 100% renewable energy integrated resilient grids is presented. To identify the shortcomings and propose advancements, power electronics’ technologies are categorized using the proposed concepts of natural source frequencies (NSf), energy storage, direct energy conversion/control and fault protection (DeCaFp), and high-efficiency energy consumption and buffering (heECaB) technology. The ability of networked microgrids to greatly reduce power outages and power system restoration time is demonstrated by leveraging robust decentralized and centralized control algorithms, identified through a comprehensive literature review. Future research areas are proposed to further enhance grid stability, controllability, cybersecurity, and protection against faults in the presence of 100% renewable sources by leveraging the advanced capabilities of NSf, DeCaFp, and heECaB devices and system-level control algorithms.

14 SOLAR ENERGY↗

Correction for Neutral Pressure-Driven Signal in Radiated Power Measurements on Proto-MPEX

A pinhole camera using four-channel resistive bolometers was designed and implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to measure the plasma radiated power. Quantification of the radiated power is required for comprehensive power balance assessments but faces unique challenges on linear plasma devices due to weak absolute signal, compared to typical use in toroidal fusion plasmas, and high neutral pressure changes. Around 1 mTorr, the pressure-driven signal contribution was shown to overwhelm the radiated power signal in Proto-MPEX, found to be ~3 μW . Since the pressure-driven signals could not be predicted from first principle arguments, the signals were corrected using empirical models that take two experimental pressure measurements and the raw bolometer signal to reveal the radiated power signals. Four “gas-only” Proto-MPEX shots were taken, without the radio frequency (rf) plasma discharge, to train, optimize, and validate empirical models. The data included two pressure measurements at different locations along with the bolometer signal. Multiple models were tested; partial least-squares regression with a cross correlation method to account for the time offset in the pressure measurements provided the best combination of accuracy and stability. The model was validated to have a modeling error of 0.0036 V, which was lower than 10% of the expected radiated power signal. The model was tested on a different “gas-only” shot with a complete time-series data. For plasma operation shots, the corrected bolometer measurements were compared with an absolute extreme ultraviolet photodiode measurement and similarities and differences are discussed.

Lee, Seungsup↗

Penetration Bounds For Azimuthal Slot On Infinite Cylinder With Finite Length Backing Cylindrical Cavity

We examine coupling into azimuthal slots on an infinite cylinder with a infinite length interior cavity operating both at the fundamental cavity modal frequencies, with small slots and a resonant slot, as well as higher frequencies. The coupling model considers both radiation on an infinite cylindrical exterior as well as a half space approximation. Bounding calculations based on maximum slot power reception and interior power balance are also discussed in detail and compared with the prior calculations. For higher frequencies limitations on matching are imposed by restricting the loads ability to shift the slot operation to the nearest slot resonance; this is done in combination with maximizing the power reception as a function of angle of incidence. Finally, slot power mismatch based on limited cavity load quality factor is considered below the first slot resonance.

42 ENGINEERING↗

Power System Resilience Enhancement in Typhoons Using a Three-Stage Day-Ahead Unit Commitment

In this work, we propose a three-stage resilient unit commitment model which considers uncertain typhoon paths and line outages to improve the power system resilience against typhoon events. The proposed solution coordinates resources in response to the worst-case scenario for each possible typhoon path. The optimal decision is based on the characterization of the power system schedule into three stages of preventive control, emergency control, and restoration. Preventive control is performed before the typhoon occurs by quickly adjusting the three-stage resilient unit commitment schedule; emergency control is conducted during the typhoon by shedding local loads to meet the power balance, while other control strategies are assumed to be unavailable due to possible interruptions in the communication system; restoration is realized after the typhoon, when resources are optimally dispatched to repair the outages of critical devices and recover the normal operation state of the power system quickly. Considering the typhoon path uncertainty, we have introduced a stochastic model for possible typhoon paths where all possible affected lines along each typhoon path are assumed to be on outage during the typhoon. Accordingly, we explore the strategy for co-optimizing the three stages in unit commitment. The proposed model is tested on the IEEE 118-bus system and the real-world provincial system to verify its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Segment Decentralized Control Strategies for Renewables-Rich Microgrids in Extreme Conditions

Microgrids provide a promising approach to accommodating various distributed energy resources (DERs), while requiring significant communication infrastructures that may be affected by extreme conditions such as natural disasters and cyber-attacks. In this paper, a fully decentralized control strategy without the need for communication is proposed for islanded microgrids with high renewables penetration. First, special multi-segment power/frequency characteristic curves are designed, so that different DERs can be automatically coordinated in a prioritized manner such as renewables first to maintain power balance while DER frequencies are regulated at their reference values. Second, piecewise linear served load versus frequency models are designed to prioritize loads according to their significance, so that only noncritical loads will be curtailed as needed while critical loads are supplied without any interruptions during power deficiency. The proposed strategy can effectively deal with various normal and extreme system conditions including 100% renewables penetration, loads and renewables variations, power deficiencies requiring load curtailments, disconnection of existing DERs, connection of new DERs as well as network sectionalization and reconfiguration. As a result, the proposed control strategy is validated in the real-time digital simulator (RTDS) model of the IIT Campus Microgrid to demonstrate its effectiveness in enhancing the resiliency of renewables-rich microgrids in extreme conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal mitigation and control over power system dynamics for stochastic grid resilience

Optimal mitigation planning for highly disruptive contingencies to a transmission-level power system requires optimization with dynamic power system constraints, due to the key role of dynamics in system stability to major perturbations. We formulate a generalized disjunctive program to determine optimal grid component hardening choices for protecting against major failures, with differential algebraic constraints representing system dynamics (specifically, differential equations representing generator and load behavior and algebraic equations representing instantaneous power balance over the transmission system). We optionally allow stochastic optimal pre-positioning across all considered failure scenarios, and optimal emergency control within each scenario. This novel formulation allows, for the first time, analyzing the resilience interdependencies of mitigation planning, preventive control, and emergency control. Using all three strategies in concert is particularly effective at maintaining robust power system operation under severe contingencies, as we demonstrate on the western system coordinating council 9-bus test system using synthetic multi-device outage scenarios.

30 DIRECT ENERGY CONVERSION↗