Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “position trajectory time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Muon reconstruction in the Daya Bay water pools

Muon reconstruction in the Daya Bay water pools would serve to verify the simulated muon fluxes and offer the possibility of studying cosmic muons in general. This reconstruction is, however, complicated by many optical obstacles and the small coverage of photomultiplier tubes (PMTs) as compared to other large water Cherenkov detectors. The PMTs’ timing information is useful only in the case of direct, unreflected Cherenkov light. This requires PMTs to be added and removed as an hypothesized muon trajectory is iteratively improved, to account for the changing effects of obstacles and direction of light. Therefore, muon reconstruction in the Daya Bay water pools does not lend itself to a general fitting procedure employing smoothly varying functions with continuous derivatives. Here, we describe an algorithm which overcomes these complications. It employs the method of Least Mean Squares to determine an hypothesized trajectory from the PMTs’ charge-weighted positions. This initially hypothesized trajectory is then iteratively refined using the PMTs’ timing information. Reconstructions with simulated data reproduce the simulated trajectory to within about 5° in direction and about 45 cm in position at the pool surface, with a bias that tends to pull tracks away from the vertical by about 3°.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chaotic and integrable magnetic fields in one-dimensional hybrid Vlasov–Maxwell equilibria

The construction of kinetic equilibrium states is important for studying stability and wave propagation in collisionless plasmas. Thus, many studies over the past decades have been focused on calculating Vlasov–Maxwell equilibria using analytical and numerical methods. However, the problem of kinetic equilibrium of hybrid models is less studied, and self-consistent treatments often adopt restrictive assumptions ruling out cases with irregular and chaotic behaviour, although such behaviour is observed in spacecraft observations of space plasmas. In this paper, we develop a one-dimensional (1-D), quasineutral, hybrid Vlasov–Maxwell equilibrium model with kinetic ions and massless fluid electrons and derive associated solutions. The model allows for an electrostatic potential that is expressed in terms of the vector potential components through the quasineutrality condition. The equilibrium states are calculated upon solving an inhomogeneous Beltrami equation that determines the magnetic field, where the inhomogeneous term is the current density of the kinetic ions and the homogeneous term represents the electron current density. We show that the corresponding 1-D system is Hamiltonian, with position playing the role of time, and its trajectories have a regular, periodic behaviour for ion distribution functions that are symmetric in the two conserved particle canonical momenta. For asymmetric distribution functions, the system is nonintegrable, resulting in irregular and chaotic behaviour of the fields. The electron current density can modify the magnetic field phase space structure, inducing orbit trapping and the organization of orbits into large islands of stability. Thus, the electron contribution can be responsible for the emergence of localized electric field structures that induce ion trapping. We also provide a paradigm for the analytical construction of hybrid equilibria using a rotating two-dimensional harmonic oscillator Hamiltonian, enabling the calculation of analytic magnetic fields and the construction of the corresponding distribution functions in terms of Hermite polynomials.

Kaltsas, Dimitrios A. (ORCID:0000000300769015)↗

Magnetic field observations near Venus - Preliminary results from Mariner 10

The NASA-GSFC magnetic field experiment on Mariner 10 is the first flight of a dual magnetometer system conceived to permit accurate measurements of weak magnetic fields in space in the presence of a significant and variable spacecraft magnetic field. Results from a preliminary analysis of a limited data set are summarized in this report, which is restricted primarily to Venus encounter. A detached bow shock wave that develops as the super Alfvenic solar wind interacts with the Venusian atmosphere has been observed. However, the unique coincidence of trajectory position and interplanetary field orientation at the time of bow shock crossing led to a very disturbed shock profile with considerably enhanced upstream magnetic fluctuations. At present it is not possible to ascertain the nature and characteristics of the obstacle responsible for deflecting the solar wind flow. Far downstream disturbances associated with the solar wind wake have been observed.

Ness, N. F.↗

Traffic Prediction for Uncommunicative Aircraft in Terminal Airspace: Development Framework and Performance Evaluations

This paper presents an air traffic prediction algorithm that takes observations of an aircraft and classifies aircraft type, estimates the aircraft's intent to and method of joining an airport traffic pattern, and predicts the aircaft's future trajectory. To develop algorithms that enable autonomous aircraft to safely insert into un-towered traffic patterns, several challenges need to be addressed. These challenges range from traffic detection to sensor fusion to own-ship trajectory replanning. Critical to a trajectory replanning algorithm is information regarding the future behavior of all traffic aircraft in the operational environment. The presented traffic prediction algorithm generates this information using regular measurements of traffic aircraft position and velocity to classify the aircraft by speed-class, estimate how the aircraft will approach the runway, and construct a predicted trajectory to the runway including future positions and velocities at specific times. The predictions of the presented algorithm are the necessary inputs for any downstream traffic pattern sequencing and own-ship trajectory planning routines. The presented algorithm is benchmarked using approximately 300 randomized traffic trajectories, spanning four vehicle weight classes and eight traffic entry types. While the algorithm can process multiple traffic vehicles in the terminal area, there is no prediction of traffic-on-traffic interaction. Each traffic vehicle is processed separately.

John D McMinn↗

Method and apparatus for adaptive force and position control of manipulators

The present invention discloses systematic methods and apparatus for the design of real time controllers. Real-time control employs adaptive force/position by use of feedforward and feedback controllers, with the feedforward controller being the inverse of the linearized model of robot dynamics and containing only proportional-double-derivative terms is disclosed. The feedback controller, of the proportional-integral-derivative type, ensures that manipulator joints follow reference trajectories and the feedback controller achieves robust tracking of step-plus-exponential trajectories, all in real time. The adaptive controller includes adaptive force and position control within a hybrid control architecture. The adaptive controller, for force control, achieves tracking of desired force setpoints, and the adaptive position controller accomplishes tracking of desired position trajectories. Circuits in the adaptive feedback and feedforward controllers are varied by adaptation laws.

Seraji, Homayoun↗

Kilovoltage Intrafraction Monitoring for Prostate Intensity Modulated Arc Therapy: First Clinical Results

Purpose: Most linear accelerators purchased today are equipped with a gantry-mounted kilovoltage X-ray imager which is typically used for patient imaging prior to therapy. A novel application of the X-ray system is kilovoltage intrafraction monitoring (KIM), in which the 3-dimensional (3D) tumor position is determined during treatment. In this paper, we report on the first use of KIM in a prospective clinical study of prostate cancer patients undergoing intensity modulated arc therapy (IMAT). Methods and Materials: Ten prostate cancer patients with implanted fiducial markers undergoing conventionally fractionated IMAT (RapidArc) were enrolled in an ethics-approved study of KIM. KIM involves acquiring kV images as the gantry rotates around the patient during treatment. Post-treatment, markers in these images were segmented to obtain 2D positions. From the 2D positions, a maximum likelihood estimation of a probability density function was used to obtain 3D prostate trajectories. The trajectories were analyzed to determine the motion type and the percentage of time the prostate was displaced {>=}3, 5, 7, and 10 mm. Independent verification of KIM positional accuracy was performed using kV/MV triangulation. Results: KIM was performed for 268 fractions. Various prostate trajectories were observed (ie, continuous target drift, transient excursion, stable target position, persistent excursion, high-frequency excursions, and erratic behavior). For all patients, 3D displacements of {>=}3, 5, 7, and 10 mm were observed 5.6%, 2.2%, 0.7% and 0.4% of the time, respectively. The average systematic accuracy of KIM was measured at 0.46 mm. Conclusions: KIM for prostate IMAT was successfully implemented clinically for the first time. Key advantages of this method are (1) submillimeter accuracy, (2) widespread applicability, and (3) a low barrier to clinical implementation. A disadvantage is that KIM delivers additional imaging dose to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-60: Evaluation of Temporal Lag in Radiotherapy Gating for Tumor Motion Trajectories

Purpose: Evaluating timing differences between LINAC beam ON/OFF and the estimation of tumor positioning using gating systems is essential for establishing confidence when treating with gating during radiotherapy, and is an annual requirement of TG-142. Temporal discrepancies between the trajectories of external marker surrogates and beam delivery may vary depending upon the type of external marker motion, which is quantified in this work for several trajectories. Methods: A precise robotic 3D motion stage performed several trajectories typically used for gating phantoms, including sinusoidal and Lujan-type motion; a commercial respiratory motion simulator was also employed. The true motions were monitored using variable resistors. The beam ON/OFF was controlled separately by two RPM (Varian) systems, an integrated version delivered by a Varian Truebeam LINAC and version 1.6 delivered by a Varian Trilogy, and measured using a diode. The resistor and diode signals were read by a multichannel digital oscilloscope, and timing differences between beam ON/OFF as measured by the diode and the phantom motion were determined using a peak detection algorithm. Results: Timing differences between beam ON/OFF and 3D stage motion peaks (diode—true motion timing) were computed to be 79.4 & 57.7ms for sinusoidal motion and 109.1 & 63.6ms for Lujan-type motion on the Truebeam LINAC, for beam ON and OFF, respectively. Timing differences for the Trilogy LINAC were 34.4 & 55.2ms for the sinusoidal motion and 29.0 & 26.3ms for the Lujan-type motion, for beam ON and OFF, respectively. With the commercial motion simulator, the timing differences were found to be −9ms and −78ms for beam ON/OFF, respectively, with the Truebeam, and −97.6ms and −60.9ms for beam ON/OFF, respectively, with the Trilogy. Conclusion: Setup-dependent temporal lags were found using this methodology. These discrepancies have the potential to influence quality assurance on gating systems and ultimately the treatment dose during radiotherapy. NIH National Institute of Biomedical Imaging and Bioengineering grant T32 EB002103-21.

60 APPLIED LIFE SCIENCES↗

The IRAS radiation environment

Orbital flux integration for three selected mission altitudes and geographic instantaneous flux-mapping for nominal flight-path altitude were used to determine the external charged particle radiation predicted for the Infrared Astronomy Satellite. A current field model was used for magnetic field definitions for three nominal circular trajectories and for the geographic mapping positions. Innovative analysis features introduced include (1) positional fluxes as a function of time and energy for the most severe pass through the South Atlantic Anomaly; (2) total positional doses as a function of time and shield thickness; (3) comparison mapping fluxes for ratios of positional intensities to orbit integrated averages; and (4) statistical exposure-time history of a trajectory as a function of energy indicating, in percent of total mission duration, the time intervals over which the instantaneous fluxes would exceed the orbit integrated averages. Results are presented in tables and graphs.

Stassinopoulos, E. G.↗

Orbit Determination Adaptations for the Cassini Grand Finale

satellite encounters. Over this period, there have been several papers describing the orbit determination process and performance up through 2016 [1-5]. In April of 2017, Cassini will enter its Grand Finale mission phase when it will traverse the gap between the D-ring and the Saturn atmosphere twenty-two times before plunging deep into the atmosphere to end the mission. The lack of targeted satellite encounters during this period necessitates updates to the nominal Cassini Orbit Determination (OD) process. This paper describes these planned adaptations for the operation of the Grand Finale. During the Equinox and Solstice Mission Phase (2008-2016), navigation analysis has been divided into segments focused on two particular targeted satellite encounters, called an “arc”. Maneuvers in an arc were usually targeted to encounter B-plane position and time, so the OD state and covariance were mapped forward to the B-plane of the encounter within the arc. Trajectory dispersions during the Grand Finale need instead to be mapped to equator crossings and targeted Cartesian positions. In addition, trajectory arcs have typically covered a few orbital revolutions (~2-8 weeks), in order to span the time between two encounters. However, the Grand Finale will encompass five months of time without an encounter which necessitates an adjusted arc strategy. A modified arc strategy was developed based on OD behavior during long multi-rev periods between encounters in the year leading up to the Grand Finale. The OD covariance study conducted for the Grand Finale mission phase will also be examined.

Criddle, Kevin↗

Trajectories of high energy electrons in a plasma focus

Measurements are made of high-energy electron trajectories in a plasma focus as functions of position, time, energy, and angle of emission. The spatial resolution of the X-ray emission shows that low-energy X-rays are emitted from the anode surface. It is also suggested that the highest energy X-rays originate from a small region on the axis. The so-called shadow technique shows that the electron beam is perpendicular to the anode surface. Polar diagrams of medium and high-energy X-rays agree with the bremsstrahlung emission from a relativistic electron beam, the current of which is several 100 A.

Harries, W. L.↗

Thermal Analysis Methods for an Earth Entry Vehicle

Thermal analysis of a vehicle designed to return samples from another planet, such as the Earth Entry vehicle for the Mars Sample Return mission, presents several unique challenges. The Earth Entry Vehicle (EEV) must contain Martian material samples after they have been collected and protect them from the high heating rates of entry into the Earth's atmosphere. This requirement necessitates inclusion of detailed thermal analysis early in the design of the vehicle. This paper will describe the challenges and solutions for a preliminary thermal analysis of an Earth Entry Vehicle. The aeroheatina on the vehicle during entry would be the main driver for the thermal behavior. and is a complex function of time, spatial position on the vehicle, vehicle temperature, and trajectory parameters. Thus. the thermal analysis must be closely tied to the aeroheating analysis in order to make accurate predictions. Also, the thermal analysis must account for the material response of the ablative thermal protection system TPS. For the exo-atmospheric portion of the mission, the thermal analysis must include the orbital radiation fluxes on the surfaces. The thermal behavior must also be used to predict the structural response of the vehicle (the thermal stress and strains) and whether they remain within the capability of the materials. Thus, the thermal analysis requires ties to the three-dimensional geometry, the aeroheating analysis, the material response analysis, the orbital analysis. and the structural analysis. The goal of this paper is to describe to what degree that has been achieved.

Amundsen, Ruth M.↗

Thermal Analysis Methods For Earth Entry Vehicle

Thermal analysis of a vehicle designed to return samples from another planet, such as the Earth Entry vehicle for the Mars Sample Return mission, presents several unique challenges. The Earth Entry Vehicle (EEV) must contain Martian material samples after they have been collected and protect them from the high heating rates of entry into the Earth's atmosphere. This requirement necessitates inclusion of detailed thermal analysis early in the design of the vehicle. This paper will describe the challenges and solutions for a preliminary thermal analysis of an Earth Entry Vehicle. The aeroheating on the vehicle during entry would be the main driver for the thermal behavior, and is a complex function of time, spatial position on the vehicle, vehicle temperature, and trajectory parameters. Thus, the thermal analysis must be closely tied to the aeroheating analysis in order to make accurate predictions. Also, the thermal analysis must account for the material response of the ablative thermal protection system (TPS). For the exo-atmospheric portion of the mission, the thermal analysis must include the orbital radiation fluxes on the surfaces. The thermal behavior must also be used to predict the structural response of the vehicle (the thermal stress and strains) and whether they remain within the capability of the materials. Thus, the thermal analysis requires ties to the three-dimensional geometry, the aeroheating analysis, the material response analysis, the orbital analysis, and the structural analysis. The goal of this paper is to describe to what degree that has been achieved.

Amundsen, Ruth M.↗

Sensitivity of back‐projection algorithm (BPA) synthetic aperture radar (SAR) image formation to initial position, velocity, and attitude navigation errors

Abstract The Back‐Projection Algorithm (BPA) is a time‐domain‐matched filtering technique to form synthetic aperture radar (SAR) images. To produce high‐quality BPA images, precise navigation data for the radar platform must be known. Errors in position, velocity, or attitude result in improperly formed images that are corrupted by shifting and blurring. The contribution of this paper is the development of analytical expressions that characterise the relationship between navigation errors and image formation errors from an inertial navigation point of view, where trajectory estimation errors in position, velocity, and attitude propagate through time and cause compounding errors in the vehicle state vector. These analytical expressions are verified via simulated image formation and real‐data image formation.

Lindstrom, Colton↗

SU-E-P-13: Quantifying the Geometric Error Due to Irregular Motion in Four-Dimensional Computed Tomography (4DCT)

Purpose: Respiratory correlated 4DCT images are generated under the assumption of a regular breathing cycle. This study evaluates the error in 4DCT-based target position estimation in the presence of irregular respiratory motion. Methods: A custom-made programmable externally-and internally-deformable lung motion phantom was placed inside the CT bore. An abdominal pressure belt was placed around the phantom to mimic clinical 4DCT acquisitio and the motion platform was programmed with a sinusoidal (±10mm, 10 cycles per minute) motion trace and 7 motion traces recorded from lung cancer patients. The same setup and motion trajectories were repeated in the linac room and kV fluoroscopic images were acquired using the on-board imager. Positions of 4 internal markers segmented from the 4DCT volumes were overlaid upon the motion trajectories derived from the fluoroscopic time series to calculate the difference between estimated (4DCT) and “actual” (kV fluoro) positions. Results: With a sinusoidal trace, absolute errors of the 4DCT estimated markers positions vary between 0.78mm and 5.4mm and RMS errors are between 0.38mm to 1.7mm. With irregular patient traces, absolute errors of the 4DCT estimated markers positions increased significantly by 100 to 200 percent, while the corresponding RMS error values have much smaller changes. Significant mismatches were frequently found at peak-inhale or peak-exhale phase. Conclusion: As expected, under conditions of well-behaved, periodic sinusoidal motion, the 4DCT yielded much better estimation of marker positions. When an actual patient trace is used 4DCT-derived positions showed significant mismatches with the fluoroscopic trajectories, indicating the potential for geometric and therefore dosimetric errors in the presence of cycle-to-cycle respiratory variations.

60 APPLIED LIFE SCIENCES↗

Trajectory and velocity measurement of a particle in spray by digital holography

We present a method for the trajectory and the velocity measurement of a particle in spray by digital holography. Based on multiple exposure digital in-line holography, a sequence of digital holograms of a dynamic spray particle field at different times are recorded with a CW laser and a high-speed CCD. The time evolution of the serial positions of particles, i.e., the motion trajectories of the particles, is obtained by numerically reconstructing the synthetic hologram of a sequence of digital holograms. The center coordinate (x,y) of each particle image can be extracted using a Hough transform and subpixel precision computing, and the velocity of an individual particle can also be obtained, which is then applied to measuring the velocity of diesel spray and alcohol spray. The research shows that the method presented in this paper for measuring spray field is feasible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Impulse to Time Optimal Finite Burn Trajectory Conversion

A novel conversion algorithm is presented that combines the fidelity of indirect optimization methods with the generality of direct methods to more easily solve time-optimal, finite-burn pseudo-rendezvous problems. An algorithm is described that converts a set of multiple-impulses, representing the entirety or a portion of a high- or low-thrust maneuver, to an exact time optimal finite-burn trajectory for a thrust limited, constant exhaust velocity spacecraft. A pseudo-rendezvous problem is one that yields a solution whose final time, position and velocity state is equal to that of the original post-impulsive trajectory. An iterative adjoint-control transformation is used to initialize the optimal control two-point boundary value problem. Examples are shown for both high and low-thrust non-coplanar Earth orbit transfers, as well as a low-thrust Hohmann-type Earth-Mars transfer.

Fogel, J.↗

First evaluation of the feasibility of MLC tracking using ultrasound motion estimation

Purpose: To quantify the performance of the Clarity ultrasound (US) imaging system (Elekta AB, Stockholm, Sweden) for real-time dynamic multileaf collimator (MLC) tracking. Methods: The Clarity calibration and quality assurance phantom was mounted on a motion platform moving with a periodic sine wave trajectory. The detected position of a 30 mm hypoechogenic sphere within the phantom was continuously reported via Clarity’s real-time streaming interface to an in-house tracking and delivery software and subsequently used to adapt the MLC aperture. A portal imager measured MV treatment field/MLC apertures and motion platform positions throughout each experiment to independently quantify system latency and geometric error. Based on the measured range of latency values, a prostate stereotactic body radiation therapy (SBRT) delivery was performed with three realistic motion trajectories. The dosimetric impact of system latency on MLC tracking was directly measured using a 3D dosimeter mounted on the motion platform. Results: For 2D US imaging, the overall system latency, including all delay times from the imaging and delivery chain, ranged from 392 to 424 ms depending on the lateral sector size. For 3D US imaging, the latency ranged from 566 to 1031 ms depending on the elevational sweep. The latency-corrected geometric root-mean squared error was below 0.75 mm (2D US) and below 1.75 mm (3D US). For the prostate SBRT delivery, the impact of a range of system latencies (400–1000 ms) on the MLC tracking performance was minimal in terms of gamma failure rate. Conclusions: Real-time MLC tracking based on a noninvasive US input is technologically feasible. Current system latencies are higher than those for x-ray imaging systems, but US can provide full volumetric image data and the impact of system latency was measured to be small for a prostate SBRT case when using a US-like motion input.

60 APPLIED LIFE SCIENCES↗

Seismic Recovery of Acoustic Source Height During the OSIRIS-REx Sample Return Capsule Re-Entry

Controlled hypersonic reentries with well‐constrained trajectories are exceedingly rare, yet they provide valuable reference cases for validating geophysical source characterization methods applicable to bolides and space debris. The 24 September 2023 re‐entry of the OSIRIS‐REx Sample Return Capsule, the first interplanetary capsule to return over the contiguous United States in nearly two decades, presented such an opportunity. Here, we present seismic observations of this event recorded at 16 stations across three sites at ground distances of 7–20 km from the trajectory. Using eigenray tracing through ground‐to‐space atmospheric specifications, we invert picked acoustic‐to‐seismic travel times for effective shock‐generated acoustic source altitudes along the known trajectory. The method recovers source heights of 57.9–59.5 km with travel‐time residuals <1 s across all stations. The seismic‐derived source heights, when compared at their along‐track positions, fall within the range of previously published infrasound‐derived heights for the corresponding trajectory segment, with intermethod differences comparable with the timing‐based uncertainty. These results suggest that air‐to‐ground coupling does not introduce a resolvable systematic timing bias in the picked near‐field seismic arrivals, supporting seismic observations as a complementary tool for altitude estimation of bolides, re‐entry vehicles, and other hypersonic atmospheric sources.

Silber, Elizabeth Allaryce [Sandia National Labora↗