Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pollution measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of tunable high pressure CO2 laser for lidar measurements of pollutants and wind velocities

The problem of laser energy extraction at a tunable monochromatic frequency from an energetic high pressure CO2 pulsed laser plasma, for application to remote sensing of atmospheric pollutants by Differential Absorption Lidar (DIAL) and of wind velocities by Doppler Lidar, was investigated. The energy extraction principle analyzed is based on transient injection locking (TIL) at a tunable frequency. Several critical experiments for high gain power amplification by TIL are presented.

Levine, J. S.↗

A study of a dual polarization laser backscatter system for remote identification and measurement of water pollution

Remote identification and measurement of subsurface water turbidity and oil on water was accomplished with analytical models which describe the backscatter from smooth surface turbid water, including single scatter and multiple scatter effects. Lidar measurements from natural waterways are also presented and compared with ground observations of several physical water quality parameters.

Sheives, T. C.↗

Towards non-contact pollution monitoring in sewers with hyperspectral imaging

Monitoring water quality in sewers is challenging, particularly because state-of-the-art technologies require contact with the raw wastewater. The presence of fat, oil, grease, and solids makes automated grab sampling difficult and causes sensor fouling. To overcome these limitations, non-contact methods based on light reflectance, such as hyperspectral imaging (HSI), are gaining attention. However, HSI has never been tested for raw wastewater. To assess its accuracy for measuring pollution, we developed a laboratory setup and performed targeted experiments with a combination of raw and diluted wastewater, as well as synthetic turbidity stock solutions. We measured seven pollution variables: chemical oxygen demand, turbidity, dissolved organic compounds, ammonium, total nitrogen, phosphate, and sulphates. We used automated pixel selection and partial least squares regression to retrieve pollution information from the hyperspectral images. Our results, based on 144 samples, suggest that HSI can estimate pollution levels with a precision in the range of state-of-the-art absorbance spectrophotometric methods. Additionally, we found that the combination of pixel and wavelength selection, enabled by the hyperspectral data structure, significantly influences the performance of partial least square modelling. Overall, our findings indicate that HSI is a promising technology for non-contact monitoring of water quality in raw wastewater.

54 ENVIRONMENTAL SCIENCES↗

Review of measurement and testing problems

Good instrumentation was required to obtain reliable and repeatable baseline data. Problems that were encountered in developing such a total system were: (1) accurate airflow measurement, (2) precise fuel flow measurement, and (3) the instrumentation used for pollutant measurement was susceptible to frequent malfunctions. Span gas quality had a significant effect on emissions test results. The Spindt method was used in the piston aircraft emissions program. The Spindt method provided a comparative computational procedure for fuel/air ratio based on measured emissions concentrations.

Source record↗

Measurement of Particulate Pollutants in the Atmosphere

Representative measurements of the mass concentration of particulate matter in the atmosphere are presented, to demonstrate the application of a new type of instrument evolved from aerospace research to various types of particulate pollution and their dynamics. The instrument employs aerodynamic impaction of particles onto an adhesive-coated piezo-electric crystal whose resonant frequency decreases with mass accretion on its surface, with a resulting particulate mass resolution of 10(exp -11) gram. Applications include air basin with aerial measurement of particulate mass concentration, jet aircraft wake, stationary industrial sources, direct on-line measurement of automobile exhaust, and techniques for source detection.

Ckuan, Raymond L.↗

Remote measurements of ambient air pollutants with a bistatic laser system

The ambient air pollutants ozone, nitric oxide, and ethylene have been monitored in the Pasadena area with a bistatic IR laser apparatus. These pollutants were measured with a differential absorption technique, using selected wavelengths in the 9.5-, 5.2-, and 10.5-micron regions, respectively. The transmitted laser radiation was detected using both direct and heterodyne detection techniques. In the direct detection case, cube corner retroreflectors provided the return, and the heterodyne detection responded to scattered radiation from various rough surfaces, ranging from 400 m to 1.9 km in distance from the apparatus. Significant departures from ambient background concentration levels were noticed in the region near a local freeway during periods of moderate and heavy traffic.

Menzies, R. T.↗

Radiometer mission requirements for large space antenna systems

Requirements are defined for Earth observational microwave radiometry using large space antenna systems with apertures in the 50 to 200 meter range. General Earth observational needs, specific measurement requirements, orbital mission guidelines and constraints, and general radiometric requirements are defined. Specific measurements include soil moisture, water surface temperature, water roughness, ice boundaries, salinity, and water pollutants. Measurements with 10 to 1 km spatial resolution and 3 to 1 day temporal resolution are required.

Keafer, L. S., Jr.↗

A Panchromatic Imaging Fourier Transform Spectrometer for the NASA Geostationary Coastal and Air Pollution Events Mission

This paper summarizes the design and development of the Panchromatic Imaging Fourier Transform Spectrometer (PanFTS) for the NASA Geostationary Coastal and Air Pollution Events (GEO-CAPE) Mission. The PanFTS instrument will advance the understanding of the global climate and atmospheric chemistry by measuring spectrally resolved outgoing thermal and reflected solar radiation. With continuous spectral coverage from the near-ultraviolet through the thermal infrared, this instrument is designed to measure pollutants, greenhouse gases, and aerosols as called for by the U.S. National Research Council Decadal Survey; Earth Science and Applications from Space: National Imperatives for the Next Decade and Beyond1. The PanFTS instrument is a hybrid instrument based on spectrometers like the Tropospheric Emissions Spectrometer (TES) that measures thermal emission, and those like the Orbiting Carbon Observatory (OCO), and the Ozone Monitoring Instrument (OMI) that measure scattered solar radiation. Simultaneous measurements over the broad spectral range from IR to UV is accomplished by a two sided interferometer with separate optical trains and detectors for the ultraviolet-visible and infrared spectral domains. This allows each side of the instrument to be independently optimized for its respective spectral domain. The overall interferometer design is compact because the two sides share a single high precision cryogenic optical path difference mechanism (OPDM) and metrology laser as well as a number of other instrument systems including the line-of-sight pointing mirror, the data management system, thermal control system, electrical system, and the mechanical structure. The PanFTS breadboard instrument has been tested in the laboratory and demonstrated the basic functionality for simultaneous measurements in the visible and infrared. It is set to begin operations in the field at the California Laboratory for Atmospheric Remote Sensing (CLARS) observatory on Mt. Wilson measuring the atmospheric chemistry across the Los Angeles basin. Development has begun on a flight size PanFTS engineering model (EM) that addresses all critical scaling issues and demonstrates operation over the full spectral range of the flight instrument which will show the PanFTS instrument design is mature.

Imaging spectrometer(↗

Recent progress in the remote detection of vapours and gaseous pollutants

Work has been continuing on the correlation spectrometry techniques described at previous remote sensing symposiums. Advances in the techniques are described which enable accurate quantitative measurements of diffused atmospheric gases to be made using controlled light sources, accurate quantitative measurements of gas clouds relative to background using solar illumination and semi-quantitation measurements of well diffused atmospheric gases using solar illumination. Specific applications of these techniques are described including preliminary results of a high altitude balloon experiment designed to test the feasibility of measuring pollution at the earth's surface from high altitude balloons and satellites.

Moffat, A. J.↗

Experimental Characterization of Hydrocarbons and Nitrogen Oxides Production in a Heavy-Duty Diesel–Natural Gas Reactivity-Controlled Compression Ignition Engine

Reactivity-Controlled Compression Ignition (RCCI) combustion is considered one of the most promising Low-Temperature Combustion (LTC) concepts aimed at reducing greenhouse gases for the transportation and power generation sectors. Due to the spontaneous combustion of a lean, nearly homogeneous mixture of air and low-reactivity fuel (LRF), ignited through the direct injection of a small quantity of high-reactivity fuel (HRF), RCCI (dual-fuel) shows higher efficiency and lower pollutants compared to conventional diesel combustion (CDC) if run at very advanced injection timing. Even though a HRF is used, the use of advanced injection timing leads to high ignition delays, compared to CDC, and generates high cycle-to-cycle variability, limited operating range, and high pressure rise rates at high loads. This work presents an experimental analysis performed on a heavy-duty single-cylinder compression ignited engine in dual-fuel diesel–natural gas mode. The objective of the present work is to investigate and highlight the correlations between combustion behavior and pollutant emissions, especially unburned hydrocarbons (HC) and oxides of nitrogen (NOx). Based on the analysis of crank-resolved pollutants measurements performed through fast FID and fast NOx systems under different engine operating conditions, two correlations were found demonstrating a good accordance between pollutant production and combustion behavior: Net Cyclic Hydrocarbon emission—cyclic IMEP variations (R 2 = 0.86), and Cyclic NOx—maximum value of the Rate of Heat Released (R 2 = 0.82).

33 ADVANCED PROPULSION SYSTEMS↗

Indoor air quality in California homes with code-required mechanical ventilation

Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 , and nitrogen oxides (NO X ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM 2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometer requirements for Earth-observation systems using large space antennas

Requirements are defined for Earth observation microwave radiometry for the decade of the 1990's by using large space antenna (LSA) systems with apertures in the range from 50 to 200 m. General Earth observation needs, specific measurement requirements, orbit mission guidelines and constraints, and general radiometer requirements are defined. General Earth observation needs are derived from NASA's basic space science program. Specific measurands include soil moisture, sea surface temperature, salinity, water roughness, ice boundaries, and water pollutants. Measurements are required with spatial resolution from 10 to 1 km and with temporal resolution from 3 days to 1 day. The primary orbit altitude and inclination ranges are 450 to 2200 km and 60 to 98 deg, respectively. Contiguous large scale coverage of several land and ocean areas over the globe dictates large (several hundred kilometers) swaths. Radiometer measurements are made in the bandwidth range from 1 to 37 GHz, preferably with dual polarization radiometers with a minimum of 90 percent beam efficiency. Reflector surface, root mean square deviation tolerances are in the wavelength range from 1/30 to 1/100.

Keafer, L. S., Jr.↗

Comparison of Lidar Methods for Remote Measurement of Air Pollutants

This paper presents quantitative comparisons of several single-ended lidar techniques for the remote measurement of gaseous pollutants. These techniques are divided into two groups. The first group is based on the measurement of energy scattered directly by the gas of interest. The gaseous scattering processes considered are ordinary fluorescence, resonance fluorescence (also called resonance scattering), Raman scattering, and resonant (or nearly resonant) Raman scattering. The second group is based on the measurement of a characteristic differential absorption produced by the gas of interest at two discrete wavelengths, using energy scattered back toward the receiver by a remote reflector other than the gas of interest. The remote reflector may be intermixed with the gas of interest, as is the case with aerosols and atmospheric gases (principally nitrogen), or they may be fixed reflectors such as terrestrial objects or retroflectors. The detectability of a given material will depend on the magnitude and characteristics of the optical interaction with that material. The main characteristics of interest are the cross section, the response time, and the spectral response of the material relative to both the transmit and receive functions of the lidar. These characteristics and their implications for remote sensing will be reviewed for the four direct scatter processes and for the differential absorption technique. The characteristic behavior of the direct backscatter technique is different from the differential absorption technique with respect to sensitivity, concentration of material, and the effect of range. For these reasons, the direct backscatter processes cannot be compared directly to the differential absorption technique. The two techniques can be compared for specific material and system configurations, however. This paper describes specific lidar system configurations and gives the calculated performance level for these systems in both the direct backscatter and differential absorption modes for a wide variety of pollutant monitoring situations. The results of this comparison of techniques indicate that the differential- absorption lidar technique can provide adequate range and sensitivity for a wide variety of pollution monitoring applications involving a number of interesting pollutant materials. No other single technique appears to provide these capabilities for such a wide range of materials.

Wright, M. L.↗

Quantifying air quality co-benefits to industrial decarbonization: the local Air Emissions Tracking Atlas

Many decarbonization technologies have the added co-benefit of reducing short-lived climate pollutants, such as particulate matter (PM), nitrogen oxides (NO x ), and sulfur dioxide (SO 2 ), creating a unique opportunity for identifying strategies that promote both climate change solutions and opportunities for air quality improvement. However, stakeholders and decision-makers may struggle to quantify how these co-benefits will impact public health for the communities most affected by industrial air pollution. To address this problem, the LOCal Air Emissions Tracking Atlas (LOCAETA) fills a data availability and analysis gap by providing estimated air quality benefits from industrial decarbonization options, such as carbon capture and storage (CCS). These co-benefits are calculated using an algorithm that connects disparate datasets that separately report greenhouse gas emissions and other pollutants at U.S. industrial facilities. Version 1.0 of LOCAETA displays the estimated primary PM 2.5 emission reduction co-benefits from additional pretreatment equipment for CCS on industrial and power facilities across the state of Louisiana, as well as the potential for VOC and NH 3 generation. The emission reductions are presented in the tool alongside facility pollutant emissions information and relevant air quality, environmental, demographic, and public health datasets, such as air toxics cancer risk, satellite and in situ pollutant measurements, and population vulnerability metrics. LOCAETA enables regulators, policymakers, environmental justice communities, and industrial and commercial users to compare and contrast quantifiable public health benefits due to air quality impacts from various climate change mitigation strategies using a free and publicly-available tool. Additional pollutant reductions can be calculated using the same methodology and will be available in future versions of the tool.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Remote Measurement of Pollution-A 40-Year Langley Retrospective: Aerosols and Clouds - Part 2

A workshop was convened in 1971 by the National Aeronautics and Space Administration (NASA) on the Remote Measurement of Pollution (RMOP), and the findings and recommendations of its participants are in a NASA Special Publication (NASA SP-285). The three primary workshop panels and their chairmen were focused on trace gas species (Will Kellogg), atmospheric particulates or aerosols (Verner Suomi), and water pollution (Gifford Ewing). Many of the workshop participants were specialists in the techniques that might be employed for regional to global-scale, remote measurements of the atmospheric parameters from Earth-orbiting satellites. In 2011 the author published a 40-year retrospective (or Part I) of the instrumental developments that were an outgrowth of the RMOP panel headed by Will Kellogg, i.e., on atmospheric temperature and gaseous species. The current report (or Part II) is an analogous retrospective of the vision of the panel led by Verner Suomi for the measurement of particulates (or aerosols) and clouds and for their effects on Earth s radiation budget. The class of measurement techniques includes laser radar or lidar, solar occultation, limb emission and scattering, nadir-viewing photometry or radiometry, and aerosol polarimetry. In addition, the retrospective refers to the scientific imperatives that led to those instrument developments of 1971-2010. Contributions of the atmospheric technologists at the Langley Research Center are emphasized, and their progress is placed in the context of the parallel and complementary work from within the larger atmospheric science community.

Remsberg, Ellis E.↗