Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “polarizing beam splitter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Making and Inspecting Large Wire Grids

Old techniques refined and combined to make new polarizers. Equipment and procedures developed for fabrication and inspection of large, precisely-spaced, flat grids of wire. Technology includes refinements and combinations of established techniques for winding grids of electron tubes and ruling optical gratings and incorporates recent developments in electronic control and laser/electronic-based metrology. Wire wrapped on frame half translated under automatic control to achieve desired space between turns. Frame halves put together, and excess wire cut away, leaving finished grid mounted in frame. Useful as polarizers and beam splitters for electromagnetic radiation in overlapping ranges of long infrared and microwaves.

Magner, Thomas J.↗

Contrast analysis in two-beam laser interference lithography

Interference lithography enables large area, sub-µm, periodic patterning without photomasks or projection lithography tools. We show that optical contrast, which is the fundamental design variable of interference lithography, enforces coupled constraints on source coherence, beam pointing stability, field size, polarization state, and the intensity balance between beams. The analysis enables selection and alignment tolerance of components to meet a specific design requirement. In particular, the analysis reveals that grating beam splitters are significantly less sensitive to beam pointing and polarization misalignment than plate beam splitters.

Miller, David B. (ORCID:0000000207755284)↗

Fiber optic gyroscope using an eight-component LiNbO3 integrated optic circuit

A LiNbO3 integrated optic circuit (IOC) containing eight optical functions has been successfully incorporated into an interferometric fiber optic gyroscope. The IOC has the minimum configuration optical functions (a phase modulator, a polarizer, and two beam splitters) and Jet Propulsion Laboratory's novel beat detection circuit (a phase modulator, two optical taps, and a beam splitter) which provides a means of directly reading angular position and rotation rate. The optical subsystem consisting of the fiber-pigtailed IOC and a sensing coil of 945 meters of polarization-maintaining fiber has a loss of 18.7dB, which includes 9dB due to the architecture and unpolarized source. A random walk coefficient was measured using an edge-emitting LED as the source.

Minford, W. J.↗

Instrumentation optimization in Fourier spectroscopy. I - Far infrared beam splitters

Computations of the reflectivity, transmissivity, and efficiency properties for TE, TM, and T45 deg waves of far-infrared beam splitters and of the polarizations induced at both reflection and transmission are described. Effects of variations in the state of polarization, orientation, pointing accuracy, and wavelength of the incident light, as well as variations in refractive index and thickness of the beam splitters, are discussed. These results apply directly to Fourier interferometer-spectrometers. They can be used for optimizing the performance of these instruments. They indicate, in particular, that some advantages may be gained by the use of incident polarized light (angle of polarization smaller than about 45 deg or negative elliptical polarization) or light of large incidence angle (larger than approximately 60 deg) or both.

Deuze, J. L.↗

Scanning Miniature Microscopes without Lenses

The figure schematically depicts some alternative designs of proposed compact, lightweight optoelectronic microscopes that would contain no lenses and would generate magnified video images of specimens. Microscopes of this type were described previously in Miniature Microscope Without Lenses (NPO - 20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43 and Reflective Variants of Miniature Microscope Without Lenses (NPO 20610), NASA Tech Briefs, Vol. 26, No. 9 (September 1999), page 6a. To recapitulate: In the design and construction of a microscope of this type, the focusing optics of a conventional microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. Elimination of focusing optics reduces the size and weight of the instrument and eliminates the need for the time-consuming focusing operation. The microscopes described in the cited prior articles contained two-dimensional CCDs registered with two-dimensional arrays of microchannels and, as such, were designed to produce full two-dimensional images, without need for scanning. The microscopes of the present proposal would contain one-dimensional (line image) CCDs registered with linear arrays of microchannels. In the operation of such a microscope, one would scan a specimen along a line perpendicular to the array axis (in other words, one would scan in pushbroom fashion). One could then synthesize a full two-dimensional image of the specimen from the line-image data acquired at one-pixel increments of position along the scan. In one of the proposed microscopes, a beam of unpolarized light for illuminating the specimen would enter from the side. This light would be reflected down onto the specimen by a nonpolarizing beam splitter attached to the microchannels at their lower ends. A portion of the light incident on the specimen would be reflected upward, through the beam splitter and along the microchannels, to form an image on the CCD. If the nonpolarizing beam splitter were replaced by a polarizing one, then the specimen would be illuminated by s-polarized light. Upon reflection from the specimen, some of the s-polarized light would become p-polarized. Only the p-polarized light would contribute to the image on the CCD; in other words, the image would contain information on the polarization rotating characteristic of the specimen.

Wang, Yu↗

PRELIMINARY JPSS-3 VIIRS POLARIZATION SENSITIVITY AND COMPARISON WITH S-NPP, JPSS-1 AND -2

The Visible-Infrared Imaging Radiometer Suite (VIIRS) was first launched on-board the Suomi National Polar-orbiting Partnership (S-NPP) spacecraft in October of 2011. There have been three subsequent builds of the VIIRS sensor for the Joint Polar Satellite System (JPSS) program with JPSS-1, -2 and -3 having launch dates of November 2017, March 2022 and 2026 respectively. There is also a JPSS-4 VIIRS, that is in hardware integration during 2020, with a launch date of 2031. VIIRS has 22 bands: 7 thermal emissive bands (TEBs), 14 reflective solar bands (RSBs) and a Day Night Band (DNB). Ocean Color/Chlorophyll (OCC) products use calibrated Science Data Records (SDRs) for bands M1-M7(0.412-0.865μm) to compute their ocean chemistry products. These bands require accurate polarization sensitivity characterization to compensate for polarized upwelling Rayleigh scatter and produce accurate OCC Environment Data Products (EDRs). VIIRS polarization sensitivity requirement failures have driven hardware modifications to the bandpass filters and dichroic beam splitter over the program. This paper will discuss the preliminary JPSS-3 polarization results and how these hardware modifications, as the JPSS program progresses, have affected the sensor performance. Comparisons of the polarization sensitivities between sensor builds will be discussed along with the hardware modifications that contributed to their differences.

VIIRS↗

Preliminary JPSS-3 VIIRS Polarization Sensitivity and Comparison with S-NPP, JPSS-1 and -2

The Visible-Infrared Imaging Radiometer Suite (VIIRS) was first launched on-board the Suomi National Polar-orbiting Partnership (S-NPP) spacecraft in October of 2011. There have been three subsequent builds of the VIIRS sensor for the Joint Polar Satellite System (JPSS) program with JPSS-1, -2 and -3 having launch dates of November 2017, March 2022 and 2026 respectively. There is also a JPSS-4 VIIRS, that is in hardware integration during 2020, with a launch date of 2031. VIIRS has 22 bands: 7 thermal emissive bands (TEBs), 14 reflective solar bands (RSBs) and a Day Night Band (DNB). Ocean Color/Chlorophyll (OCC) products use calibrated Science Data Records (SDRs) for bands M1-M7 (0.412-0.865μm) to compute their ocean chemistry products. These bands require accurate polarization sensitivity characterization to compensate for polarized upwelling Rayleigh scatter and produce accurate OCC Environment Data Products (EDRs). VIIRS polarization sensitivity requirement failures have driven hardware modifications to the bandpass filters and dichroic beam splitter over the program. This paper will discuss the preliminary JPSS-3 polarization results and how these hardware modifications, as the JPSS program progresses, have affected the sensor performance. Comparisons of the polarization sensitivities between sensor builds will be discussed along with the hardware modifications that contributed to their differences.

VIIRS↗

Beam-splitter for infrared detection of pollutants

Germanium optical elements at proper tilt angles minimize effects of polarization and radiance variations of background scene. Energy-division ratio is less dependent on angle of incidence of entrance beam.

Massey, W. A.↗

Systems level polarization modeling of multispectral space sensors

The 2-percent polarization sensitivity specification in many of NASA's Earth Observing System sensors has motivated Santa Barbara Research Center (SBRC) to develop computer programs that model the polarization characteristics of optical systems. In support of the Moderate Resolution Imaging Spectroradiometer program, SBRC has developed an analytical tool which unites the completed 3D lens design and coating designs to accurately predict an optical system's polarization characterization compensators, nonnormal incidence reflection and transmission from dichroic beam splitters and protected silver mirrors are analyzed without the need for proprietary coating prescriptions. The phenomenon of diattenuation and phase change are treated using the Jones matrix formalism.

Wells, Conrad↗

Wind dynamic range video camera

A television camera apparatus is disclosed in which bright objects are attenuated to fit within the dynamic range of the system, while dim objects are not. The apparatus receives linearly polarized light from an object scene, the light being passed by a beam splitter and focused on the output plane of a liquid crystal light valve. The light valve is oriented such that, with no excitation from the cathode ray tube, all light is rotated 90 deg and focused on the input plane of the video sensor. The light is then converted to an electrical signal, which is amplified and used to excite the CRT. The resulting image is collected and focused by a lens onto the light valve which rotates the polarization vector of the light to an extent proportional to the light intensity from the CRT. The overall effect is to selectively attenuate the image pattern focused on the sensor.

Craig, G. D.↗

Analysis of Quantum Information Test-Bed by Parametric Down-Converted Photons Interference Measurement

Quantum optical experiments require all the components involved to be extremely stable relative to each other. The stability can be "measured" by using an interferometric experiment. A pair of coherent photons produced by parametric down-conversion could be chosen to be orthogonally polarized initially. By rotating the polarization of one of the wave packets, they can be recombined at a beam splitter such that interference will occur. Theoretically, the interference will create four terms in the wave function. Two terms with both photons going to the same detector, and two terms will have the photons each going to different detectors. However, the latter will cancel each other out, thus no photons will arrive at the two detectors simultaneously under ideal conditions. The stability Of the test-bed can then be inferred by the dependence of coincidence count on the rotation angle.

To, Wing H.↗

Optical multiple object tracking techniques

Two multichannel multiple-object tracking techniques are reviewed. In the diffraction grating technique, the input scene is picked up by a TV camera and imaged onto a liquid-crystal light valve (LCLV), and the output side of the light valve is illuminated with a suitably polarized and collimated coherent laser beam to yield a reflected beam with polarization modulated according to the intensity of the incoherent input. This reflected beam passes through a beam splitter cube and an analyzer, resulting in an intensity modulated coherent image. An array of spectrum islands containing the information of the input appears after crossing a contact screen/lens combination. In the multiple-focus hololens technique, the scene of moving objects is sent into the LCTVSLM through a camera; a collimated laser beam is incident upon the LCTV screen; a low-pass filter is inserted between the LCTVSLM and the hololens for the removal of the high order diffractions due to the grid structure of the LCTV. The feasibility of the LCTVSLM and multiple-focus hololens technique is demonstrated.

Liu, Hua-Kuang↗

The HYDICE instrument design and its application to planetary instruments

The Hyperspectral Digital Imagery Collection Experiment (HYDICE) instrument represents a significant advance in the state of the art in hyperspectral sensors. It combines a higher signal-to-noise ratio (SNR) and significantly better spatial and spectral resolution and radio metric accuracy than systems flying on aircraft today. The need for 'clean' data, i.e., data free of sampling artifacts and excessive spatial or spectral noise, is a key driver behind the difficult combination of performance requirements laid out for HYDICE. Most of these involve the sensor optics and detector. This paper presents an optimized approach to those requirements, one that comprises push broom scanning, a single, mechanically cooled focal plane, a double-pass prism spectrometer, and an easily fabricated yet wide-field telescope. Central to the approach is a detector array that covers the entire spectrum from 0.4 to 2.5 microns. Among the major benefits conferred by such a design are optical and mechanical simplicity, low polarization sensitivity, and coverage of the entire spectrum without suffering the spectral gaps caused by beam splitters. The overall system minimizes interfaces to the C-141 aircraft on which it will be flown, can be calibrated on the ground and in flight to accuracies better than those required, and is designed for simple, push-button operation. Only unprocessed data are recorded during flight. A ground data processing station provides quick-look, calibration correction, and archiving capabilities, with a throughput better than the requirements. Overall performance of the system is expected to provide the solid database required to evaluate the potential of hyperspectral imagery in a wide variety of applications. HYDICE can be regarded as a test bed for future planetary instruments. The ability to spectrally image a wide field of view over multiple spectral octaves offers obvious advantages and is expected to maximize science return for the required cost and weight.

Basedow, R.↗

Design of an 8-40 GHz Antenna for the Wideband Instrument for Snow Measurements (WISM)

This poster describes the implementation of a 6x6 element, dual linear polarized array with beamformer that operates from about 8-40 GHz. It is implemented using a relatively new multi-layer microfabrication process. The beamformer includes baluns that feed dual-polarized differential antenna elements and reactive splitters that cover the full frequency range of operation. This fixed beam array (FBA) serves as the feed for a multi-band instrument designed to measure snow water equivalent (SWE) from an airborne platform known as the Wideband Instrument for Snow Measurements (WISM).

8-40 GHz Antenna↗

Scattered-light uniformity imager for diagnosing laser absorption asymmetries on OMEGA

Light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. Observations from OMEGA implosions show much larger scattered-light asymmetries than predictions. A new instrument has been developed to absolutely measure the scattered-light intensity and nonuniformity for the purpose of diagnosing the asymmetry. The scattered-light uniformity imager (SLUI) diagnostic records the variation in scattered-light intensity over a transmission diffuser using a charge-coupled device (CCD)/lens assembly. At the standard operating position, an 11.3° (f/2.5) cone of light is collected. A stray light baffle, debris shield, and antireflection absorbing filter are also incorporated into the diagnostic payload inserted into the target chamber. The imaging parts of the diagnostic (light baffle, vacuum window, filters, lens, and CCD camera) are located outside the target chamber. Five SLUIs have been built and deployed in OMEGA’s ten-inch manipulator diagnostic ports, covering almost 5% of the emission surface, enabling an absolute scattered-light measurement should be within a few percent of the global average. Each SLUI system is calibrated offline, providing absolute scattered-light intensity measurements. Based on the measured point spread function, each diffuser plate image contains over 20 000 independent scattered-light absolute-intensity measurements of the variation over the collection cone. SLUI provides a platform to study scattered light and absorption asymmetries, and their possible sources.

47 OTHER INSTRUMENTATION↗

Fiber-optic rotation sensor technology

A concept for an all-waveguide fiber-optic rotation sensor is discussed, and the results of preliminary tests of key elements are described. A single channel waveguide coupler design provides the functions of an optical switch, a 3-dB beam splitter, a phase retarder, and a signal modulator, all of which may be formed on the same chip and interconnected by channel single-mode waveguides. Preliminary test results for the waveguide coupler and for a rotation sensor without the coupler are presented. Signal processing, polarization control, and interconnection of the waveguide components are discussed.

Goss, W. C.↗

Multiband selection with linear array detectors

Several techniques that can be used in an earth-imaging system to separate the linear image formed after the collecting optics into the desired spectral band are examined. The advantages and disadvantages of the Multispectral Linear Array (MLA) multiple optics, the MLA adjacent arrays, the imaging spectrometer, and the MLA beam splitter are discussed. The beam-splitter design approach utilizes, in addition to relatively broad spectral region separation, a movable Multiband Selection Device (MSD), placed between the exit ports of the beam splitter and a linear array detector, permitting many bands to be selected. The successful development and test of the MSD is described. The device demonstrated the capacity to provide a wide field of view, visible-to-near IR/short-wave IR and thermal IR capability, and a multiplicity of spectral bands and polarization measuring means, as well as a reasonable size and weight at minimal cost and risk compared to a spectrometer design approach.

Richard, H. L.↗

CIRS and CIRS-Lite as Designed for the Outer Planets: TSSM, EJSM, JUICE

Passive spectroscopic remote sensing of planetary atmospheres and surfaces in the thermal infrared is a powerful tool for obtaining information about surface and atmospheric temperatures, composition, and dynamics (via the thermal wind equation). Due to its broad spectral coverage, the Fourier transform spectrometer (FTS) is particularly suited to the exploration and discovery of molecular species. NASA Goddard's Cassini CIRS FTS has given us important new insights into stratospheric composition and jets on Jupiter and Saturn, the cryo-vo1cano and thermal stripes on Enceladus, and the polar vortex on Titan. We have designed a lightweight successor to CIRS - called CIRS-lite - with improved spectral resolution to separate blended spectral lines (such as occur with isotopes). CIRS-lite includes four key components: (1) high Tc superconductor bolometer/carbon nano-tube (CNT) absorber (approx 87K, YBCO) (2) synthetic diamond beam splitter (approx 140K) (3) moving mirror mechanism with crossed-roller bearings ( approx 110 K) (4) single crystal silicon for the input telescope primary

Brasunas, J.↗