Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “polarimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Simultaneous Aerosol and Ocean Polarimeter Products Using Coupled Atmosphere-Ocean Vector Radiative Transfer and Neural Networks: The PACE-MAPP Algorithm

We describe the PACE-MAPP algorithm that simultaneously retrieves aerosol and ocean optical parameters using multiangle and multi-channel polarimeter measurements from the SPEXone, Hyper-Angular Rainbow Polarimeter 2 (HARP2), and Ocean Color Instrument (OCI) instruments onboard the NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) observing system PACE-MAPP is adapted from the Research Scanning Polarimeter (RSP) Microphysical Aerosol Properties from Polarimetry (RSP-MAPP) algorithm. A key feature of the MAPP family of algorithms is the use of a coupled vector radiative transfer model such that the atmosphere and ocean are always considered together as one system. Consequently, conservation of energy ensures that negative water-leaving radiances do not occur. PACE-MAPP uses optimal estimation to simultaneously characterize the optical and microphysical properties of aerosol and ocean constituents, find the optimal solution, and reliably account for the uncertainties of each parameter. This coupled approach, together with multiangle, multi-channel polarimeter measurements, will enable retrievals of aerosol and water properties across the Earth’s oceans. The PACE-MAPP algorithm provides aerosol and ocean products for both the open ocean and coastal areas and is designed to be accurate, modular, and efficient by using fast neural networks that replace the time-consuming vector radiative transfer calculations. We provide an overview of the PACE-MAPP framework and also describe its modular components including its aerosol and hydrosol models, ocean bio-optical models, and thin cirrus model.

Snorre Stamnes↗

Correlation polarimeter-interferometer in the DIII-D tokamak

A correlation polarimeter-interferometer system has been developed for the DIII-D tokamak to detect small amplitude magnetic and density fluctuations. Two collinear, frequency-offset (5–15 MHz), orthogonally polarized (right- and left-handed, circularly polarized) electromagnetic waves at 650 GHz probing the plasma are used to detect the Faraday effect. A third, linearly polarized, electromagnetic wave serves as the local-oscillator to provide a measure of the line-averaged density. Correlation polarimetric measurement is accomplished by correlating the Faraday effect measured along the same line of sight using two independent detectors, whereas simultaneous correlation interferometric measurement is realized by correlating the line-averaged density measured at two different intermediate frequencies. The noise floor of the correlation polarimeter-interferometer has been demonstrated to be more than one order of magnitude lower than that of a standard polarimeter-interferometer measurement. Line-averaged correlation polarimetric-interferometric measurements in DIII-D H-mode plasmas show broadband (up to 750 kHz) magnetic and density fluctuations with amplitudes as low as 0.03 $Gauss$/$\sqrt{kHz}$ and 4 × 10 13 m –3 /$\sqrt{kHz}$, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Complete Stokes vector analysis with a compact, portable rotating waveplate polarimeter

Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.

47 OTHER INSTRUMENTATION↗

In-Flight Validation of the Metis Visible-Light Polarimeter Coronagraph on Board Solar Orbiter

Context. The Metis coronagraph is one of the remote sensing instruments of the ESA-NASA Solar Orbiter mission. The goal for the instrument is to enable the study of the solar atmosphere and solar wind by simultaneously acquiring images of the solar corona at two different wavelengths: visible light (VL), within a band ranging from 580 nm to 640 nm, and ultraviolet light, in the HI Lyα 121.6 ± 10 nm. The visible-light channel of the coronagraph includes a polarimeter with electro-optically modulating liquid crystal variable retarders to measure the linearly polarized brightness of the K-corona and derive the electron density. Aims. In this paper, we present the first in-flight validation results of the Metis polarimetric channel together with a comparison to the on-ground calibrations. This paper seeks to validate the first use of an electro-optical device, the liquid crystal-based polarimeter, in deep space and within a hard radiation environment. Methods. We used the orientation of the K-corona’s linear polarization vector during the roll maneuvers of the Space Orbiter spacecraft for the in-flight calibration. Results. The Metis coronagraph on board the Solar Orbiter shows good agreement with the on-ground measurements. The in-flight validation confirms the expected performance of the visible-light channel polarimeter. Furthermore, a comparison between the first polarized brightness value obtained by Metis and the polarized brightness values obtained by the space-based coronagraph LASCO and the ground-based coronagraph K-Cor shows the consistency of the Metis calibrated results.

Sun: corona↗

Machine Learning Based Aerosol and Ocean Color Joint Retrieval Algorithm for Multiangle Polarimeters over Coastal Waters

NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, recently launched in February 2024, carries two multiangle polarimeters (MAPs): the UMBC Hyper-Angular Rainbow Polarimeter (HARP2) and SRON Spectropolarimeter for Planetary Exploration One (SPEXone). Measurements from these MAPs will greatly advance ocean ecosystem and aerosol studies as their measurements contain rich information on microphysical properties of aerosols and hydrosols. The Multi-Angular Polarimetric Ocean coLor (MAPOL) joint retrieval algorithm has been developed to retrieve aerosol and ocean color information, which uses a vector radiative transfer (RT) model as the forward model. The RT model is computationally expensive, which makes processing a large amount of data challenging. FastMAPOL was developed to expedite retrieval using neural networks to replace the RT forward models. As a prototype study, FastMAPOL was initially limited to open ocean applications where the ocean Inherent Optical Properties (IOPs) were parameterized in terms of one parameter: chlorophyll-a concentration (Chla). In this study we further expand the FastMAPOL joint retrieval algorithm to incorporate NN based forward models for coastal waters, which use multi-parameter bio-optical models. In addition, aerosols are represented by six components, i.e., fine mode non absorbing insoluble (FNAI), brown carbon (BrC), black carbon (BC), fine mode non absorbing soluble (FNAS), sea salt (SS) and non-spherical dust (Dust). Sea salt and dust are coarse mode aerosols, while the other components are in the fine mode. The sizes and spectral refractive indices are fixed for each aerosol component, while their abundances are retrievable. The multi-parameter bio-optical model and aerosol components are chosen to represent the coastal marine environment. The retrieval algorithm is applied to synthetic measurements in three different configurations ofMAPs in the PACE mission: HARP2 observations only, SPEXone observations only and combined HARP2 and SPEXone observations. The retrieval results from synthetic measurements show that for aerosol retrieval the SPEXone-only configuration works equally well with the HAPR2-only configuration. On the other hand, for ocean color retrieval the SPEXone instrument provides better information due to its larger spectral coverage. For the surface parameters (wind speed), HARP2 measurements provide better information due to its wide field of view. Combined measurement configuration HARP2+SPEXone performed the best to retrieve all aerosol, ocean color and surface parameters. We also studied the impact of sun glint to aerosol and ocean color retrievals. The retrieval test revealed that wind speed and absorbing aerosol retrieval improves significantly when including measurements at glint geometries. Furthermore, the retrieval algorithm is equipped with modules for atmospheric correction and bidirectional reflectance distribution (BRDF) correction to obtain the remote sensing reflectance, which enables ocean biogeochemistry studies using the PACE polarimeter data.

PACE↗

Systematic error analysis in the absolute hydrogen gas jet polarimeter at RHIC

The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 (E beam = 100 GeV) and 17 (255 GeV). For a typical 8 hour RHIC store, the measured proton beam average polarization was about P beam ~ 55 ± 2.0 stat ± 0.3 syst %. The elastic pp analyzing power, AN(t)~0.04, was determined with a precision of about |δA N (t)|~0.0002 in the momentum transfer squared range 0.001<-t<0.020 GeV 2 . In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.

43 PARTICLE ACCELERATORS↗

Estimating Residual Gas Beam Loss in the BNL AGS Booster:Model, Numerical Tools, and Implications for a Polarimeter Chamber

Beamloss from residual gas scattering is calculated for a storage ring of circumference C = 200m, covering a linear magnetic rigidity ramp from B ρ inj = 1.25Tm to B ρ ext = 9.50Tm over tramp = 1.00s. Three loss mechanisms are considered: nuclear inelastic reactions, single Coulomb scattering beyond the acceptance angle of the machine, and charge-state exchange for heavy ions. Calculations are performed for protons and Au 32+ ions, the latter being the charge state delivered by the EBIS pre-injector into the BNL AGS Booster. At a baseline vacuum of P 0 = 5 × 10 −11 mbar the integrated fractional beam loss over the full ramp is negligible for protons (< 0.001%) and 33.1% for Au 32+ . The impact of a 1m polarimeter section at elevated pressure P s = 5 × 10 −9 mbar is evaluated: the proton loss remains negligible, while the Au 32+ loss rises to 45.1%, establishing the vacuum requirement for the polarimeter chamber. In the present compact approximate model, Au 32+ losses are dominated by charge exchange at injection, while proton losses are dominated by single Coulomb scattering. The design, outgassing budget, pumping strategy, and commissioning sequence for a UHV polarimeter chamber housing silicon detectors and ASICs are described in detail.

43 PARTICLE ACCELERATORS↗

Design of a celestial Thomson-scattering X-ray polarimeter.

A general discussion of the scientific importance and status of stellar X-ray polarimetry is presented. A stellar X-ray polarimeter designed to fit into the bottom half of the NASA OSO-1 wheel compartment or other similar spacecraft is described. In this design, the linear polarization is obtained as a function of energy. The sensitivity of the polarimeter in the 4-24 keV energy range was optimized with the aid of a Monte Carlo simulation computer program and is given for several important celestial X-ray sources. Estimates of sensitivity thresholds for a much larger polarimeter, suitable for flight in the NASA High-Energy Astronomy Observatory (HEAO), are also given. The minimum detectable polarization for several X-ray sources is given.

Landecker, P. B.↗

Linear polarimeter with rapid modulation, achromatic in the 0.3-1.1-micron range

A polarimeter is described, which provides achromatic modulation over the spectral range 0.3 to 1.1 microns, with very small light losses. The instrument is the first one to use superachromatic half-wave plates; such a plate is made of three achromatic half-wave plates of quartz and magnesium fluoride cemented with the optical axis of the central plate making an angle of 1.00 rad with the axes of the parallel-oriented outer half-wave plates. Wavelength dependence of the axis direction of the optical axis was eliminated by using two identical such plates in front of a Wollaston prism. The plate closer to the prism is stationary, while the other is continuously rotated by a stepper motor. In the polarimeter constructed, the range of instrumentally induced wavelength dependence of the plane of polarization did not exceed 0.002 rad. Using the polarimeter on a 228-cm telescope, a 10-min integration through the blue filter of the UBV photometric system for a star of magnitude 10.0 gives the percentage polarization with a mean error of + or - 0.014%.

Frecker, J. E.↗

The OSO-8 mosaic graphite stellar X-ray polarimeter

The OSO 8 satellite, launched on June 21, 1975, contains two X-ray polarimeters. These polarimeters use mosaic crystals of graphite to yield polarization-sensitive Bragg reflection of stellar X-rays. The crystals reflect a narrow energy bandwidth centered at 2.6 and 5.2 keV. The polarimeter background signal is minimized by mounting the crystals on parabolic surfaces which focus the diffracted X-rays onto small-area beryllium-window proportional counters. This technique permits the observation of low-intensity X-ray sources and reduces the possibility of systematic background effects which could lead to a false signature of polarization. A description of the instrument is given, and preliminary results for the Crab Nebula and Cyg X-1 are presented.

Novick, R.↗

A polarimeter for the high resolution ultraviolet spectrometer/polarimeter

The design requirements of the polarimeter were established by the scientific optical objectives of the experiment to be launched aboard the Solar Max Mission which will study active solar regions. The polarization of the light is accomplished by a rotating magnesium fluoride quarter wave plate. The quarter wave plates are rotated in 22 1/2 degree steps about an axis coincidental with the light beam. As the light beam passes through the wave plate, the transformation that occurs can be expressed by mathematical equations. By having the wave plates calibrated, the data obtained from solar flares can be analyzed and meaningful information provided to the investigators. The polarimeter has two wave plates with different optical characteristics to provide both redundancy and versatility. A four mirror polarizer was added behind one wave plate to provide additional polarization. The mechanical design, testing, and operation of the polarimeter for the high resolution ultraviolet spectrometer/polarimeter are described.

Calvert, J. A.↗

A photoelastic-modulator polarimeter at Pine Mountain Observatory

The use of photoelastic polarimeters in astronomy is briefly reviewed, and a visible and near-UV photoelastic modulation polarimeter is described which has been in continuous service on the 61-cm telescope of Pine Mountain Observatory for 6 years. The polarimeter is used primarily for linear polarization measurements, but is easily adaptable to circular polarimetry. The instrument has produced data at a sensitivity level of 0.01%, with long-term absolute reproducibility.

Kemp, J. C.↗

The Haleakala Stokes polarimeter

A versatile Stokes polarimeter for solar observations has been developed. Recent improvements to the instrument include a high-resolution echelle spectrometer coupled to the telescope by optical fibers, and 128-element diode array detectors. The on-axis design on the telescope and polarimeter limit instrumental polarization to .0001, and the spectrometer detector combination provides spectral resolving power of 160,000 for any wavelength between 4000 and 11,000 A. This paper describes the Haleakala polarimeter and in particular the spectrometer with its fiber-optic coupling. Examples of Stokes line profiles observed in a sunspot are presented, together with derived vector magnetic field maps.

Mickey, D. L.↗

An imaging photoemission polarimeter for soft X-rays

Results of investigations are reviewed to assess the polarization dependence of photoemission in the optical, UV, and soft X-ray bands, as well as present a design for an imaging photoelectric polarimeter. Data regarding the effect of the dependence in the soft X-ray band are emphasized including the quantity of photons produced by each X-ray. The phase shift encountered in some experiments indicates that a third axis is present; the importance of the phase shift in understanding the vectoral photoeffect is emphasized. Measurements of the pulse height show that this measure is proportional to the number of electrons photoemitted by the incident X-ray. The development of X-ray polarimeters can be significantly improved as a result of the study of polarization sensitivity in the photoelectric effect. The design of a photoelectric polarimeter is presented, and the potential uses for the instrument include measuring the polarization of supernova remnants, AGN, and black hole candidates.

Kaaret, Philip↗

A new system model for radar polarimeters

The validity of the 2 x 2 receive R and transmit T model for radar polarimeter systems, first proposed by Zebker et al. (1987), is questioned. The model is found to be invalid for many practical realizations of radar polarimeters, which can lead to significant errors in the calibration of polarimetric radar images. A more general model is put forward, which addresses the system defects which cause the 2 x 2 model to break down. By measuring one simple parameter from a polarimetric active radar calibration (PARC), it is possible to transform the scattering matrix measurements made by a radar polarimeter to a format compatible with a 2 x 2 R and T matrix model. Alternatively, the PARC can be used to verify the validity of the 2 x 2 model for any polarimetric radar system. Recommendations for the use of PARCs in polarimetric calibration and to measure the orientation angle of the horizontal (H) and vertical (V) coordinate system are also presented.

Freeman, Anthony↗

Predicted performance of the lithium scattering and graphite crystal polarimeter for the Spectrum-X-Gamma mission

X-ray scattering from a lithium disk and Bragg reflection from a mosaic graphite crystal can be exploited to measure the linear polarization of radiation emitted from cosmic X-ray sources. The sensitivity is greatly enhanced if these polarimeters are placed at the focus of an X-ray telescope. Such devices form two of the three components of the Stellar X-Ray Polarimeter experiment scheduled to fly on the Spectrum-X-Gamma mission. The experiment will reside at the focus of one of the SODART X-ray telescopes. The expected on-axis performance of these two components of the Stellar X-Ray Polarimeter experiment based on detailed Monte-Carlo simulation is described. Various systematic effects, both external and internal to the experiment, that must be considered in order to properly design and utilize the experiment are also discussed.

Weisskopf, M. C.↗

A hard X-ray polarimeter utilizing Compton scattering

The paper describes a 50-cm-diam prototype of a novel Compton-scattering-type polarimeter for hard X-rays in the energy range 30-100 keV. The characteristics of the prototype polarimeter were investigated for various conditions. It was found that, with polarized X-rays from a simple polarizer, the detection efficiency and the modulation factor of the polarimeter with a 40-mm thick scatterer were 3.2 percent and 0.57 percent, respectively, at about 60 keV.

Sakurai, H.↗

A Burst Chasing X-ray Polarimeter

This viewgraph presentation reviews the rationale, design, and importance of an X-Ray Polarimeter. There is a brief discussion of Gamma Ray Bursts, followed by a review of the theories of Gamma-Ray Bursts Polarization. This leads to the question of "How do we measure the polarization?" and a discussion of the GRB x-ray emission, the photoelectric effect and photoelectric polarimetry. The requirements for the work, can only be approached using a gas detector. This leads to a discussion of a Micropattern Gas Polarimeter, and the Time-Projection Chamber (TPC) X-ray Polarimeter.

Hill, Joanne↗