Improving Advanced Inverter Control Convergence in Distribution Power Flow

Simulation of modern distribution system powerflow increasingly requires capturing the impact of advanced PV inverter voltage regulation on powerflow. With Volt/var control, the inverter adjusts its reactive power flow as a function of the point of common coupling (PCC) voltage. Similarly, Volt/watt control curtails active power production as a function of PCC voltage. However, with larger systems and higher penetrations of PV, this active/reactive power flow itself can cause significant changes to the PCC voltage potentially introducing oscillations that slow the convergence of system simulations. Improper treatment of these advanced inverter functions could potentially lead to incorrect results. This paper explores a simple approach to speed such convergence by blending in the previous iteration's reactive power estimate to dampen these oscillations. Results with a single large (5MW) PV system and with multiple 500kW advanced inverters show dramatic improvements using this approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooperative Inverters to Overcome PLL Malfunctions

This paper presents a cooperative strategy between smart inverters to overcome instability and undesired trips of inverters caused by Phase-Locked Loop (PLL) malfunctions. For the grid-interactive inverter, PLL is typically required to measure the phase angle of the AC voltage at the Point of Common Coupling (PCC) of the inverter. Accurate phase-angle measurement is critical for grid-interactive inverters to stay synchronized with the power grid. If the inverters are interconnected through a communication link, they can support each other by sharing their grid information, such as phase-angles at their PCCs. The cooperative strategy utilizes the phase-angles and voltages at PCCs in a neighborhood to identify any possible PLL malfunctions or measurement inaccuracies and then enable the inverters to make corrective decisions. The efficacy of the cooperative strategy has been verified through simulation results in MATLAB/Simulink environment in this paper.

Sadeque, Fahmid↗

Evaluation of Multiple Inverter Volt-VAR Control Interactions with Realistic Grid Impedances

Integration of large numbers of distributed photovoltaic (PV) systems in electric distribution circuits often requires advanced functions (e.g. volt-VAR, frequency-Watt etc.). However, significant concerns have been raised about potential for PV inverters with such controls to interact with one another in a way that could cause grid instability. The lack of standardized inverter models makes it hard to simulate such transient interactions in software. Similarly it is very hard to test these dynamic inverter interactions in the laboratory. In this paper, unique Power Hardware-in-the-Loop (PHIL) techniques are presented to experimentally test for interactions of multiple PV inverters connected to multiple points-of-common-coupling (PCCs) with grid impedances between them. Sample test results are provided from simulation-only scenarios and PHIL testing. Though simulation results indicated possible harmful interactions between inverters' volt-VAR controllers; no such interactions were found in the limited hardware testing.

14 SOLAR ENERGY↗

A Novel Grid-forming Voltage Control Strategy for Supplying Unbalanced Microgrid Loads Using Inverter-based Resources

This paper presents a novel grid-forming voltage control strategy for a battery energy storage system to maintain balanced three-phase output voltages when serving unbalanced loads. A stationary reference frame (αβ) based control scheme is proposed to regulate positive-sequence and negative-sequence voltages. Compared with the conventional rotating reference frame (dq) based control scheme, the proposed scheme shows better dynamic performance. Then, we analyze the system zero-sequence network and propose adding a grounding transformer to the Y/Yg connected output transformer to further reduce the voltage unbalance at the point of common coupling. The simulation results demonstrate the effective performance of the proposed voltage control scheme. Based on the results, the power-voltage unbalance curve is derived for different output transformer configurations to establish the relationship between the power unbalance limit and the voltage unbalance limit for microgrid power scheduling.

Xu, Bei↗

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a novel statistical parameters based data driven approach for passive islanding detection. The proposed scheme relies in the voltage data, measured at the point of common coupling, and is comprised of three stages. The Stage-1 quickly detects what is termed as coarse islanding, Stage-2 computes the decaying DC detector (DDCD), and 3) finally, the digital relay logic (DRL) is devised in Stage-3. The proposed scheme is tested as per the IEEE-1547, UL 1741 and IEC-62116 standards. Various tests are investigated on the modified IEEE-13 bus system, modeled in PSCAD/EMTDC, under stringent test scenarios such as power mismatch, induction motor starting effect, capacitor bank switching and various level of loads changes, considered for both single and multiple DG systems. The test results reveal that the proposed scheme can detect islanding in less than 2 cycles, and results in nearly zero non detection zone (NDZ). Also, the scheme can very well be used for single-phase microgrids too as it relies only on the single phase voltage information.

anti-islanding protection↗

Identifying DQ-Domain Admittance Models of a 2.3-MVA Commercial Grid-Following Inverter Via Frequency-Domain and Time-Domain Data

Here, we present two methods to identify the admittance of a 2.3-MVA commercial grid-following inverter through frequency-domain data and time-domain data. In addition to the well-known harmonic injection method to obtain the admittance at frequency points followed by vector fitting, we adopt a step response-based method where the step response data of the converter are collected and their s-domain expressions are obtained. In turn, the s-domain admittance model of the converter is found. The two methods can be used for cross validation. Step responses and frequency-domain responses obtained from the two methods are compared. Results show that the time- domain data-based method leads to an admittance comparable with that from the frequency-domain measurement in the range less than 60 Hz. In addition, two insights are obtained from the frequency-domain admittance measurements. First, when the dq- frame is aligned to the point of common coupling (PCC) voltage, the per unit DQ-domain admittance directly reflects operating conditions. Second, existence of negative-sequence control can be detected via sequence-domain admittances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Hierarchical Voltage Control of a DFIG-Based Wind Power Plant for a Grid Fault

This paper proposes an adaptive hierarchical voltage control scheme of a doubly-fed induction generator (DFIG)-based wind power plant (WPP) that can secure more reserve of reactive power (Q) in the WPP against a grid fault. To achieve this, each DFIG controller employs an adaptive reactive power to voltage (Q-V) characteristic. The proposed adaptive Q-V characteristic is temporally modified depending on the available Q capability of a DFIG; it is dependent on the distance from a DFIG to the point of common coupling (PCC). The proposed characteristic secures more Q reserve in the WPP than the fixed one. Furthermore, it allows DFIGs to promptly inject up to the Q limit, thereby improving the PCC voltage support. To avert an overvoltage after the fault clearance, washout filters are implemented in the WPP and DFIG controllers; they can prevent a surplus Q injection after the fault clearance by eliminating the accumulated values in the proportional-integral controllers of both controllers during the fault. Test results demonstrate that the scheme can improve the voltage support capability during the fault and suppress transient overvoltage after the fault clearance under scenarios of various system and fault conditions; therefore, it helps ensure grid resilience by supporting the voltage stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation of a Publish-Subscribe Protocol in Microgrid Islanding and Resynchronization with Self-Discovery

Communications systems and protocols are becoming second nature to utilities operating distribution systems. Traditionally, centralized communication approaches are often used, while recently in microgrid applications, distributed communication and control schema emerge offering several advantages such as improved system reliability, plug-and-play operation and distributed intelligence. Still, operation and control of microgrids including distributed communication schema have been less of a discussion in the literature. To address the challenge of multiple-inverter microgrid synchronization, a publish-subscribe protocol based, Data Distribution Service (DDS), communication schema for microgrids is proposed in this paper. The communication schema is discussed in details for individual devices such as generators, photovoltaic systems, energy storage systems, microgrid point of common coupling switch, and supporting applications. In conclusion, islanding and resynchronization of a microgrid are demonstrated on a test-bed utilizing this schema.

25 ENERGY STORAGE↗

A Learning-based Power Management Method for Networked Microgrids Under Incomplete Information

In this paper, we present a model-free reinforcement learning (RL)-based technique to solve the power management problem of networked microgrids (MGs), when the utility has only limited or no detailed knowledge of the MG asset models.The proposed method consists of two levels: at the first level, using an approximate RL strategy and aggregated data, a utility agent determines the locational price signals to maximize its profit under incomplete information on the MGs’ private data behind their points of common coupling (PCC). The proposed RL strategy enables the utility to adapt to changing system conditions and learn from previous experiences, while respecting the data ownership of the MGs. At the second level, the MGs receive the price signals to dispatch their generation/storage assets individually over look-ahead decision time window, while considering power flow constraints. The performance of the proposed RL technique has been verified under realistic operational scenarios.

Zhang, Qianzhi↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

Networked Microgrids Optimization

This project is mainly about the operation optimization of three networked microgrids (MG), including centralized optimization and distributed optimization. The alternating direction method of multipliers (ADMM) algorithm is used for distributed optimization. In the distribution network considered here, there is a Distribution Management system (DMS) as the system coordinator and several networked microgrids. In grid-connected mode, power could be imported or exported at the distribution substation bus according to the utility rate, and the exchanged power at point of common coupling (PCC) of any microgrid has a limitation. In islanded mode, the power imports/exports at the distribution substation are zero. In both grid-connected and islanded mode, the distribution substation is taken as a slack bus with fixed voltage magnitude.

Chen, Yang [Oak Ridge National Laboratory (ORNL), ↗

Distribution System Secondary Circuit Parameter Estimation for Model Calibration

To analyze and coordinate the operation of distribution systems with rapidly increasing amounts of PV, more accurate distribution system models are required, especially for the distribution system secondary (low-voltage) circuits down to the point of common coupling for distributed PV. There is a growing need for automated procedures to calibrate the distribution system secondary circuit models that are typically either not modeled at all or are modeled with a lower level of detail than the better modeled medium-voltage systems. This report presents an accurate, flexible, and computationally efficient method to use measurement data to estimate secondary circuit series impedance parameters in existing utility feeder models. The parameter estimation method assumes well-modeled primary circuit models, known secondary circuit topologies, and AMI active power, and reactive power measurements at all the loads in the secondary circuit. The method also requires AMI voltage measurement at most of the loads in the secondary circuit but can handle loads that do not have voltage measurements. No existing secondary circuit model information is needed, except for topology. The method is based on the well-known linearized voltage drop approximation and linear regression. The performance of the method is demonstrated on a three-phase test circuit with ten different secondary circuit topologies and on the Georgia Tech campus distribution system with AMI data. The developed method can be utilized to improve existing utility feeder models for more accurate analysis and operation with ubiquitous distributed PV interconnected on the low-voltage circuits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smarter Grid Solutions | National Renewable Energy Laboratory: Active Management Integration: June 2015 - November 2016

This report presents the project results for the NREL INTEGRATE demonstration project: Active Network Management (ANM) Integration. Consistent with the INTEGRATE program's objective of increasing the grid's clean energy hosting capacity and providing grid services in a holistic manner, the project demonstrated the use of ANM to enable very high penetrations of solar PV and wind energy systems. Results obtained using a representative North American distribution system showed ANM's autonomous distributed control doubled the interconnected wind and solar systems by managing thermal and voltage constraints in real-time. These generators flexibly interconnected to the grid via ANM's end-to-end control architecture, and were managed and coordinated with other smart distributed energy resources (DER; e.g. EVs, battery ESS, controllable load) to unlock the grid's dynamic hosting capacity. As a smart grid application to standardize grid integration of diverse renewable generation sources, ANM provides the industry with a scalable, cost-effective alternative to traditional transmission and distribution (T&D) reinforcements. This project considered three use cases of the application of ANM: a Smart Home demonstration of ANM control of residential scale devices (PV, EV, and battery ESS); a Smart Campus demonstration of high penetration megawatt-scale DER (PV, EVs, battery ESS, and controllable load) behind a single point-of-common-coupling (PCC), and a Smart Distribution demonstration that combined prior use cases along with additional community/utility-scale DER at very high aggregate penetration levels. The Smart Distribution use case provided an integrated perspective of ANM across all distribution grid DER device scales (incorporating aggregated Smart Homes and the Smart Campus) in order to showcase how these devices can support smart grid services to manage DER related constraints in a safe and reliable manner; and likewise how ANM integrates with grid modernization initiatives. The ANM system was deployed in NREL's Energy Systems Integration Facility (ESIF), and project industry advisors attended an on-site demonstration and a set of workshops in order to review project outcomes and evaluate the relevance of ANM for increasing the grid hosting capacity. The outcomes of this effort include an assessment of opportunities for field deployment of ANM to address existing interconnection challenges, as well as consolidating project advisor suggestions for investment in ANM and potential future pilots for more advanced schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Energy Management System Integration with Advanced Distribution Management System

The Integrated Distribution Management System (IDMS) project was initiated to demonstrate the interactive operation of microgrid systems and the distribution systems with which they interconnect. The key technologies for this are the microgrid management system and the utility distribution management system. The IDMS project successfully demonstrated that a utility’s advanced distribution management system/distributed energy resources management system (ADMS/DERMS) could effectively manage microgrids to provide visibility and control functionalities as well as use the microgrid as a dispatchable resource to support the utility grid. The DERMS accomplishes this by determining active and reactive power needs at the point of common coupling (PCC) using advanced applications like volt/VAR watt optimization (VVWO) and load relief (LR) with the underlying core applications state estimation (SE) and load flow (LF). The ADMS/DERMS can use the microgrid as a resource to resolve and prevent violations in the grid and to optimize the operational working state of the grid. The IDMS project demonstrated that a utility-operated ADMS with embedded DERMS functionality can flexibly manage a variety of microgrids and other aggregated distributed energy resources (DER) in concert with the wider distribution grid. Microgrids can provide grid services in any number of different ways to meet the operational needs of the distribution utility. The manner of aggregation — microgrid or virtual power plant — is not necessarily relevant to the utility as long as the grid services from the aggregated DER are available and can be managed by its ADMS/DERMS for the stability and reliability of the grid. The IDMS project demonstrated this integrated ADMS concept by combining hardware/software-in-the-loop testing with commercial products from different vendors and a utility’s network model. The project integrated the Schneider Electric EcoStruxure™ ADMS with DERMS with the Schweitzer Engineering Laboratories (SEL) POWERMAX ® Microgrid Control System, and the simulated resources with energy company PECO’s model of a utility-owned microgrid, establishing an operational relationship in which the utility manages the operational functionality of a microgrid at the PCC and that provides the utility with the capability to control the comprehensive power system, inclusive of the macrogrid and microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Federated Architecture for Secure and Transactive Distributed Energy Resource Management Solutions (FAST-DERMS)

This document provides system-level specifications for a federated architecture for secure and transactive distributed energy resource management solutions (FAST-DERMS), presents a solution, and describes operational concepts for the proposed solution. FAST-DERMS enables the provision of reliable, resilient, and secure transmission and distribution (T&D) grid services through the scalable aggregation and near-real-time management of utility-scale and small-scale distributed energy resources (DERs). We first present the principles and objectives of FAST-DERMS. Then, after discussing important system concepts, we present the specifications for FAST-DERMS and a solution that employs a distributed and federated control methodology in which the DERs connected to a single point of common coupling with the rest of the system, such as individual substations, are optimized coordinately to provide system-level grid services. FAST-DERMS aims to aggregate and coordinate the operations of DERs to support T&D grid operations. The key optimization and control component of this FAST-DERMS reference implementation is a flexible resource scheduler (FRS) that aggregates the DERs within a substation service area. These FRSs operate at the substation level and perform constrained economic dispatch of DERs, either directly or through a transactive market or aggregator, as shown in Figure ES-1. An FRS Coordinator at the distribution system operator (DSO) level aggregates distribution substations operated by FRSs and interfaces with the transmission system operator (TSO) to provide transmission services. FAST-DERMS also allows for the integration of the FRS Coordinator with an existing distribution utility management system that could be employed by the DSO to enhance distribution grid operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗