Direct internal recycling fractions approaching unity

Direct internal recycling (DIR) refers to the process of recovering pure hydrogen isotopes (D/T) from helium and other impurities in the fusion plasma exhaust and directing them back to the fuel injection system. Increasing the exhaust fraction purified through DIR significantly reduces the size and cost of the tritium plant and provides additional benefits including reduced requirements for both the tritium startup inventory and tritium breeding ratio. Metal foil pumps (MFPs) are the dominant technology for this separation, relying on the concept of superpermeation. We recently demonstrated that PdCu foils operated at low temperature provide both exceptional flux and resilience to helium absorption as the DIR fraction is increased. Herein we design and demonstrate continuous and semi-batch DIR processes using PdCu MFPs. Under continuous processing, stable performance was observed for DIR fractions up to 92 %. In addition, we demonstrate a semi-batch process capable of extending the DIR fraction to unity (> 99.8 %). Under the experimental conditions described within a PdCu MFP area of ~22 m 2 would be sufficient to process the fusion exhaust with 92 % DIR fraction at expected flowrates of 100 Pa·m 3 ·s -1 for a future fusion power plant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined Normal and Disruption, Electromagnetic Transient, Thermal, and Structural Analysis of COMPASS Upgrade

We report that COMPASS Upgrade is a replacement for the COMPASS device at the Institute of Plasma Physics (IPP) of the Czech Academy of Sciences. It is a cryogenic copper machine with a major radius of 0.89 m, with 5 T at the plasma centerline and 2-MA plasma current. It is intended to develop ITER relevant plasma densities and high power fluxes in the divertor region. The entire vacuum vessel is planned to reach 500 °C. The COMPASS-U TF coil is a bitter plate-like design with radial conductor plates that extend the width of the TF inner leg. Currents redistribute radially based on resistive and inductive effects. This necessitates an electromagnetic (EM) transient analysis of the coil current distribution. For copper coils like COMPASS Upgrade, the solution must be coupled with a thermal solution to properly include the temperature-dependent resistive effects. The EM transient solution includes the TF magnetic loads, and a stress pass on the results produces in-plane loads. The EM solution chosen requires inclusion of all the conducting and nonconducting regions surrounding the TF coil. With the TF current distribution solved, the addition of the poloidal coils and resulting background fields allows the determination of the out-of-plane loads. Integration of the Joule heating produced from the EM solution produces temperature distributions throughout the shot, which can be read in to a structural pass to include thermal stresses in the evaluation. This is true of both TF and PF temperature prediction with appropriate packing fractions. Currents in the PF coils, with computed background fields, produce Lorentz loads. Time transients of the PF currents produce startup eddy currents in the structures included in the model; inclusion of the vessel and other passive structures allows these to be included in a stress pass. The EM transient solution includes all the elements needed for a disruption analysis with prescribed motions and quench of the plasma. From a model originally intended to simulate current diffusion in the TF coil, the analysis can be refined to be used to predict the performance of most of the components of the tokamak or provide boundary conditions for more detailed submodels. In this article, the use of the current diffusion model for bounding assessments of the COMPASS Upgrade TF, PF, vessel, external structure, and disruption analyses will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic analysis of magnetic equilibrium reconstruction with eddy currents on LTX- β

Magnetic equilibrium reconstruction in the Lithium Tokamak Experiment-Beta (LTX-β) is complicated by strong eddy currents and toroidal asymmetries arising from its segmented, close-fitting conducting shell. In the earlier experiment LTX, these three-dimensional (3D) conductor effects significantly distorted diagnostic signals and challenged conventional axisymmetric reconstruction methods. In this work, we demonstrate that accurate plasma equilibria can be recovered on LTX-β by incorporating a small number of dominant eddy current modes derived from realistic conductor models. Using the open-source $\tt{TokaMaker}$ Grad–Shafranov solver, we reconstruct equilibria across a systematically selected set of LTX-β discharges and validate them against the legacy $\tt{PSI-Tri}$ hybrid 2D-3D code. Our results show that fully 2D $\tt{TokaMaker}$ reconstructions achieve significantly improved agreement with flux loop and Mirnov probe measurements, reducing total chi-squared fitting errors, especially during startup. Finally, we develop new hybrid 2D-3D $\tt{TokaMaker}$ reconstructions by integrating the $\tt{ThinCurr}$ 3D eddy current model, which we optimize for significant further reduction of chi-squared in most scenarios. These findings underscore the importance of realistic wall-current modeling in short-pulse tokamaks, and establish a physics-based reconstruction framework that is extensible to devices with complex passive structures and 3D wall interactions.

Grad–Shafranov solver↗

On the frequency bifurcations of the MHD startup modes in NSTX

The observed bifurcations of the low frequency (<50 kHz) and low toroidal periodicity (n < 5) magnetohydrodynamic (MHD) activity often present in the initial part of the National Spherical Tokamak Experiment (NSTX) discharges can be explained by the evolution of the radial profile of the safety factor (q=rB φ /RB θ ) crossing multiple rational surfaces in the core. Important performance limiting instability mechanisms in the NSTX spherical tokamak are often linked to low frequency and low-n MHD activity. They are quite common in long-pulse NSTX plasmas. They can be present at the beginning of the plasma current flat-top, at the end of the discharge or during the whole duration, and they have been observed to deleteriously impact performance over a wide range of q 95 . An interesting feature observed in some NSTX discharges is the presence of a bifurcation in the frequency of the low n modes, as low as n = 1, that have frequencies comparable to the plasma core rotation divided by n. Equilibrium reconstructions constrained by magnetic diagnostics data and motional stark effect pitch angle radial profiles suggest that the observed bifurcations are linked to a fast evolving minimum value of q. Finally, 3D non-linear resistive MHD simulations show that these modes are ideal and exist as non-resonant before the correspondent rational surface enters the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessing high fidelity multi-component models to facilitate safeguards at Gas Centrifuge Enrichment Plants

We report that the International Atomic Energy Agency (IAEA) inspectors routinely carry out environmental sampling (ES) as a verification method. Collection of environmental swipe samples at various locations in Gas Centrifuge Enrichment Facilities (GCEPs) is an important process in detecting misuse of a declared facility and possibly the existence of undeclared nuclear material. These samples are measured for isotopic composition in uranium containing particles by Thermal Ionization Mass Spectrometry (TIMS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Even though ES is highly effective in detecting the absolute value of enrichments and their deviations from the declared values, it cannot explain the cause of those changes. Several potential explanations can serve as possibilities for particles detected above or other than the declared enrichment. These include normal and non-malicious events such as the design of the enrichment cascades, unintentional failures of the machines, or overshoot during startup of a cascade. It can also be the result of deliberate misuse by the facility operators. The primary objective of this work is to understand how these factors affect the enrichments produced by a cascade and quantify anticipated multi-isotopic concentrations for each case. The following methodology is employed to determine signatures at a particular facility. 1) Utilize a new two-dimensional multi-component diffusion code to obtain centrifuge performance data and use that information to design and perform cascade analysis. Compare and contrast the results with previous 1-D radially averaged solutions from the Pancake code. 2) Design a GCEP cascade with the production goal of 19.75% 235 U for each set of machine data above. Investigate two cascade scenarios that include enrichment of natural uranium (NU) feed to 19.75% 235U in a single cascade compared to a two-step process of NU to 5% and then 5% to 19.75%. 3) Simulate the intentional vs. unintentional off-normal scenarios in the cascades to assess the differences in isotopic concentrations. A non-ideal squared-off cascade model developed at the University of Virginia is used to calculate flow rates and isotopic concentrations of the process gas. The analysis is performed using the Rome machine model operated at 600 m/s rotor speed. The upper and lower bounds of normal and abnormal enrichments in a typical facility are used in conjunction with ES results to understand the root causes of such observations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation: Preprint

This paper develops a non-phase-locked loop (PLL) grid-connected inverter that can improve the microgrid’s transients during transition operation. By emulating the operation of a synchronous machine, the inverter generates its own voltage and frequency during startup, synchronizes and connects to the grid, then operates in reactive power mode (grid-feeding) with self-generated voltage and frequency, and switches to voltage-frequency mode to establish system voltage and frequency (grid-forming) when the microgrid disconnects from the main grid, and vice versa. To enable fast synchronization, active synchronization control is adopted both during inverter startup and microgrid reconnection operation. The simulation results show that the developed non-PLL grid-connected inverter works effectively to synchronize the inverter and microgrid to the grid and avoids a phase jump during microgrid transition operation. Thus, the microgrid’s transients are significantly improved with the proposed control technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of RELAP5-3D for transient analysis of a dual coolant lead lithium fusion blanket concept

Our research aims to build a multiphysics framework for transient analysis of the Dual- Coolant Lead-Lithium (DCLL) blanket design of the proposed Fusion Nuclear Science Facility (FNSF) for all Onticipated Operational Occurrences (AOOs) using Reduced Order Models (ROMs). This paper presents an assessment of using RELAP5-3D for transient thermal-hydraulic blanket analysis of the DCLL design. Preliminary validation studies for the RELAP5-3D properties were conducted using a representative vertical flow loop model and a comparison study using experimental data from the thermal convection corrosion loops at ORNL. These studies inspected the thermal hydraulic response of Lead-Lithium Eutectic (PbLi) systems within the RELAP5-3D code; mainly pressure drop and heat transfer, as compared to analytical calculations and experimental data. The Magnetohydrodynamic (MHD) pressure drop effect for liquid metal under the effects of a uniform magnetic field was implemented into our models using an equivalent forms loss coefficient based on the phasic momentum equations. We verified our implementation of MHD pressure drop within RELAP5-3D using a systematic approach consisting of two studies. Models were developed to perform comparison studies based on experimental data from the Argonne Liquid metal EXperiment (ALEX) facility and the Magnetohydrodynamic PbLi Experiment (MaPLE) facility. Using the developed validation basis, we built a simplified DCLL channel model within RELAP5-3D, inspected MHD pressure drop and performed transient temperature analysis. The DCLL channel model used radial heating data from the International Thermonuclear Experimental Reactor (ITER) which was normalized to the FNSF design. Here, a representative startup transient was performed using a relative power curve from the initial ramp up of a long-term power pulse of the Tore Supra reactor. This study demonstrated that RELAP5-3D ROMs are capable of accurate transient analysis of the DCLL blanket. We have since utilized MCNP to develop heating profiles based on the FNSF design and are working toward implementing them into our DCLL model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synchrotron radiography of Richtmyer–Meshkov instability driven by exploding wire arrays

We present a new technique for the investigation of shock-driven hydrodynamic phenomena in gases, liquids, and solids in arbitrary geometries. The technique consists of a pulsed power-driven resistive wire array explosion in combination with multi-MHz synchrotron radiography. Compared to commonly used techniques, it offers multiple advantages: (1) the shockwave geometry can be shaped to the requirements of the experiment, (2) the pressure (P > 300 MPa) generated by the exploding wires enables the use of liquid and solid hydrodynamic targets with well-characterized initial conditions (ICs), (3) the multi-MHz radiography enables data acquisition to occur within a single experiment, eliminating uncertainties regarding repeatability of the ICs and subsequent dynamics, and (4) the radiographic measurements enable estimation of compression ratios from the x-ray attenuation. In addition, the use of a synchrotron x-ray source allows the hydrodynamic samples to be volumetrically characterized at a high spatial resolution with synchrotron-based microtomography. This experimental technique is demonstrated by performing a planar Richtmyer–Meshkov instability (RMI) experiment on an aerogel–water interface characterized by Atwood number A0∼−0.8 and Mach number M∼1.5. The qualitative and quantitative features of the experiment are discussed, including the energy deposition into the exploding wires, shockwave generation, compression of the interface, startup phase of the instability, and asymptotic growth consistent with Richtmyer's impulsive theory. Additional effects unique to liquids and solids—such as cavitation bubbles caused by rarefaction flows or initial jetting due to small perturbations—are observed. It is also demonstrated that the technique is not shape dependent by driving a cylindrically convergent RMI experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.