Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plasma diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

H{sub 2}/N{sub 2} plasma damage on porous dielectric SiOCH film evaluated by in situ film characterization and plasma diagnostics

This study investigates the mechanism of H{sub 2}/N{sub 2} plasma ashing damage of porous SiOCH films. Porous SiOCH films were treated by a H{sub 2}/N{sub 2} plasma using a 100-MHz capacitively coupled plasma etcher. The impact of ions, radicals, and vacuum ultraviolet radiation on the porous SiOCH films was investigated using in situ bulk analysis techniques such as spectroscopic ellipsometry and Fourier-transform infrared spectroscopy and ex situ film characterization techniques such as dynamic secondary ion mass spectrometry and x-ray photoelectron spectroscopy. In addition, plasma analysis including vacuum ultraviolet absorption spectroscopy was performed. The film characterization and plasma analysis show that the extraction of methyl by H radicals was enhanced by light while N radicals were responsible for inhibit the extraction of Si-CH{sub 3} bonds by forming nitride layer. The H{sub 2}/N{sub 2} plasma damage mechanism is discussed based on characterization of the film and plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PLASMA DIAGNOSTICS OF AN EIT WAVE OBSERVED BY HINODE/EIS AND SDO/AIA

We present plasma diagnostics of an Extreme-Ultraviolet Imaging Telescope (EIT) wave observed with high cadence in Hinode/Extreme-Ultraviolet Imaging Spectrometer (EIS) sit-and-stare spectroscopy and Solar Dynamics Observatory/Atmospheric Imaging Assembly imagery obtained during the HOP-180 observing campaign on 2011 February 16. At the propagating EIT wave front, we observe downward plasma flows in the EIS Fe XII, Fe XIII, and Fe XVI spectral lines (log T Almost-Equal-To 6.1-6.4) with line-of-sight (LOS) velocities up to 20 km s{sup -1}. These redshifts are followed by blueshifts with upward velocities up to -5 km s{sup -1} indicating relaxation of the plasma behind the wave front. During the wave evolution, the downward velocity pulse steepens from a few km s{sup -1} up to 20 km s{sup -1} and subsequently decays, correlated with the relative changes of the line intensities. The expected increase of the plasma densities at the EIT wave front estimated from the observed intensity increase lies within the noise level of our density diagnostics from EIS Fe XIII 202/203 A line ratios. No significant LOS plasma motions are observed in the He II line, suggesting that the wave pulse was not strong enough to perturb the underlying chromosphere. This is consistent with the finding that no H{alpha} Moreton wave was associated with the event. The EIT wave propagating along the EIS slit reveals a strong deceleration of a Almost-Equal-To -540 m s{sup -2} and a start velocity of v{sub 0} Almost-Equal-To 590 km s{sup -1}. These findings are consistent with the passage of a coronal fast-mode MHD wave, pushing the plasma downward and compressing it at the coronal base.

79 ASTRONOMY AND ASTROPHYSICS↗

Plasma diagnostics of low pressure high power impulse magnetron sputtering assisted by electron cyclotron wave resonance plasma

This paper reports on an investigation of the hybrid pulsed sputtering source based on the combination of electron cyclotron wave resonance (ECWR) inductively coupled plasma and high power impulse magnetron sputtering (HiPIMS) of a Ti target. The plasma source, operated in an Ar atmosphere at a very low pressure of 0.03 Pa, provides plasma where the major fraction of sputtered particles is ionized. It was found that ECWR assistance increases the electron temperature during the HiPIMS pulse. The discharge current and electron density can achieve their stable maximum 10 {mu}s after the onset of the HiPIMS pulse. Further, a high concentration of double charged Ti{sup ++} with energies of up to 160 eV was detected. All of these facts were verified experimentally by time-resolved emission spectroscopy, retarding field analyzer measurement, Langmuir probe, and energy-resolved mass spectrometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preface to the Proceedings of the 25th Topical Conference on High-Temperature Plasma Diagnostics

The 25th Topical Conference on High-Temperature Plasma Diagnostics (HTPD 2024) was held in Asheville, NC, USA, at the Renaissance Asheville Downtown Hotel from 21 to 25 April 2024. This biennial conference brings together scientists and engineers from a variety of fields, including magnetic confinement fusion, inertial confinement fusion, space plasmas, astrophysics, and industrial applications, to discuss mutual problems in the development of instrumentation and experimental techniques for the characterization of high-temperature plasmas. As the 25th meeting, HTPD 2024 represents ∼50 years of ongoing international collaboration on these topics.

Biewer, Theodore [ORNL] (ORCID:0000000174563509)↗

Spectroscopic Investigations of Highly Charged Tungsten Ions - Atomic Spectroscopy and Fusion Plasma Diagnostics

The spectra of highly charged tungsten ions have been investigated using x-ray and extreme ultraviolet spectroscopy. These heavy ions are of interest in relativistic atomic structure theory, where high-precision wavelength measurements benchmark theoretical approaches, and in magnetic fusion research, where the ions may serve to diagnose high-temperature plasmas. The work details spectroscopic investigations of highly charged tungsten ions measured at the Livermore electron beam ion trap (EBIT) facility. Here, the EBIT-I and SuperEBIT electron beam ion traps have been employed to create, trap, and excite tungsten ions of M- and L-shell charge states. The emitted spectra have been studied in high resolution using crystal, grating, and x-ray calorimeter spectrometers. In particular, wavelengths of n = 0 M-shell transitions in K-like W 55+ through Ne-like W 64+ , and intershell transitions in Zn-like W 44+ through Co-like W 47+ have been measured. Special attention is given to the Ni-like W46+ ion, which has two strong electric-dipole forbidden transitions that are of interest for plasma diagnostics. The EBIT measurements are complemented by spectral modeling using the Flexible Atomic Code (FAC), and predictions for tokamak spectra are presented. The L-shell tungsten ions have been studied at electron-beam energies of up to 122 keV and transition energies measured in Ne-like W 64+ through Li-like W 71+ . These spectra constitute the physics basis in the design of the ion-temperature crystal spectrometer for the ITER tokamak. Tungsten particles have furthermore been introduced into the Sustained Spheromak Physics Experiment (SSPX) spheromak in Livermore in order to investigate diagnostic possibilities of extreme ultraviolet tungsten spectra for the ITER divertor. The spheromak measurement and spectral modeling using FAC suggest that tungsten ions in charge states around Er-like W 6+ could be useful for plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma diagnostic method using intermodulation frequencies in a Langmuir probe

A plasma diagnostic method using intermodulation frequencies is developed. When dual-frequency (ω{sub 1},ω{sub 2}) voltage signals are applied to a probe, the intermodulation frequencies (ω{sub 2}±ω{sub 1}, ω{sub 2}±2ω{sub 1}) between the signals are generated due to the nonlinearity of the sheath. From the analysis of the intermodulation frequencies, the plasma parameters, such as the electron temperature and the plasma density, can be obtained. The measured plasma parameters from this method are compared to the results from the measured electron energy distribution function, and they are in good agreement. Because the intermodulation currents originated from the plasma not from the stray component of the measurement system, an accurate measurement of the plasma parameters is achievable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of neutron spectrometer toward deuterium plasma diagnostics in LHD

Neutron spectrometer based on coincident counting of associated particles has been developed for deuterium plasma diagnostics on Large Helical Device (LHD) at the National Institute for Fusion Science. Efficient detection of 2.5 MeV neutron with high energy resolution would be achievable by coincident detection of a scattered neutron and a recoiled proton associated with an elastic scattering of incident neutron in a plastic scintillator as a radiator. The calculated neutron spectra from deuterium plasma heated by neutral beam injection indicate that the energy resolution of better than 7% is required for the spectrometer to evaluate energetic deuterium confinement. By using a prototype of the proposed spectrometer, the energy resolution of 6.3% and the detection efficiency of 3.3x10{sup -7} count/neutron were experimentally demonstrated for 2.5 MeV monoenergetic neutron, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold plasma diagnostics using satellite measurements of VLF signals from ground transmitters

A diagnostic technique to obtain the cold-plasma density profile in the magnetosphere is introduced. This method uses satellite measurements of group delay and pulse duration of VLF signals from ground transmitters in conjunction with a detailed ray-tracing analysis. An iterative method is involved which starts with an approximate density profile, computes the ray paths for that profile, and then compares the properties of the rays that reach the satellite location with the actual satellite measurements. The density profile is then modified to account for any discrepancies between the two results. The same process is repeated with the new profile until one has reasonable agreement between the data and ray-tracing results. This method is applied to the case of an Imp 6 pass, where strong signals from the Siple VLF transmitter were observed for over 25 min. Good agreement is found between the results of the proposed technique and the well-known ground whistler techniques of cold-plasma diagnostics. The results also serve to illustrate the wide diversity of propagation paths from ground transmitters to high-altitude satellites during VLF wave-injection experiments.

Inan, U. S.↗

Technology Issues of Burning Plasma Diagnostics

The ITER Tokamak will require many diagnostics both for safe and reliable operation of the machine and for understanding of the physics underlying the performance. The design of these diagnostics raises many challenging technical issues not faced on smaller machines. These arise partly from the increase demands on established diagnostics arising from the increased size, higher magnetic field, large heating power, and in particular the dramatically longer pulse duration of ITER, which make issue such as power loading on first wall components more challenging. The demands on reliability and availability of the machine in order to achieve the objectives within the agreed time schedule also place severe additional demands on the design, quality assurance and maintainability of diagnostics. ITER will produce many orders of magnitude more neutrons than previous Tokamaks and will be a licensed nuclear facility. This has important implications for the traceability, quality assurance and availability of safety critical diagnostics, and for the control of the design and procurement of all diagnostics. The high neutron flux/fluence also constrains the design of diagnostics, which must offer shielding consistent with the allowable dose rates on critical components of the Tokamak, and themselves be tolerant of the radiation level at the diagnostic. This paper presents an overview of the more critical issues for ITER diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma diagnostics for investigating extreme ultraviolet light sources

Plasma temperature and density diagnostics are crucial for lithographic applications of extreme ultraviolet light sources. One widely used technique employs line intensity ratios of successively charged ion states to determine the ion temperature (T{sub ionz}). This work comprises a detailed ''stress-test'' of the applied technique, where space and time resolved emission in laser-produced plasmas were studied, using a Nd:yttrium aluminum garnet laser pulse incident on an aluminum target in the 26.5-32.5 nm range. Detailed hydrodynamic simulations also investigate the dependency of ion temperature on electron density and the charge states for various line combinations (Al VI/V, Al VII/VI, Al VIII/VII, Al IX/VIII, and Al X/IX).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of excited state spatial distributions on plasma diagnostics: Atmospheric pressure laser-induced He-H{sub 2} plasma

Atmospheric pressure plasmas in helium-hydrogen mixtures with H{sub 2} molar concentrations ranging from 0.13% to 19.7% were investigated at times from 1 to 25 {mu}s after formation by a Q-switched Nd:YAG laser. Spatially integrated electron density values are obtained using time resolved optical emission spectroscopic techniques. Depending on mixture concentration and delay time, electron densities vary from almost 10{sup 17} cm{sup -3} to about 10{sup 14} cm{sup -3}. Helium based results agree reasonably well with each other, as do values extracted from the H{sub {alpha}} and H{sub {beta}} emission lines. However, in particular for delays up to about 7 {mu}s and in mixtures with less than 1% hydrogen, large discrepancies are observed between results obtained from the two species. Differences decrease with increasing hydrogen partial pressure and/or increasing delay time. In mixtures with molecular hydrogen fraction of 7% or more, all methods yield electron densities that are in good agreement. These findings seemingly contradict the well-established idea that addition of small amounts of hydrogen for diagnostic purposes does not perturb the plasma. Using Abel inversion analysis of the experimental data and a semi-empirical numerical model, we demonstrate that the major part of the detected discrepancies can be traced to differences in the spatial distributions of excited helium and hydrogen neutrals. The model yields spatially resolved emission intensities and electron density profiles that are in qualitative agreement with experiment. For the test case of a 1% H{sub 2} mixture at 5 {mu}s delay, our model suggests that high electron temperatures cause an elevated degree of ionization and thus a reduction of excited hydrogen concentration relative to that of helium near the plasma center. As a result, spatially integrated analysis of hydrogen emission lines leads to oversampling of the plasma perimeter and thus to lower electron density values compared to those obtained from helium lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Material injection alleviation and plasma diagnostic measurements during the RAM C-III flight.

The results of a material injection RF blackout alleviation experiment and of plasma diagnostic measurements using electrostatic probes and an S-band reflectometer in a 25,000 ft/sec reentry flight are presented. Significant alleviation of RF blackout is observed at altitudes of from 270,000 feet to 120,000 feet due to injection of water and Freon E-3 on VHF, S-band, C-band, and X-band frequencies. Electrostatic probe data, attenuation data, and S-band diagnostic data show consistent plasma results. The relative effectiveness of water and Freon E-3 is discussed.

Schroeder, L. C.↗

Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics

To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55–75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110–140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeterwave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma diagnostics package measurements of ionospheric ions and Shuttle-induced perturbations

The plasma diagnostics package (PDP) on the Space Shuttle STS-3 mission in March 1982 carried among its instrument complement a retarding potential analyzer. This instrument measured both the ambient ion plasma density and temperature, and perturbations to the plasma produced by Shuttle Orbiter effects. Whenever the plasma flow streamline at the instrument was more than a distance of the order of thermal ion gyroradii away from any Orbiter surface, the measurements were characteristic of the ambient ionosphere. In several situations, the PDP was positioned so as to scan the wake in the plasma flow produced by Orbiter surfaces. The density profile of the major species O(+) was consistent with a classic Mach cone. However, strong perturbations extended for several meters outside the Mach cone, which resulted in failure of flowing Maxwellian distributions to represent the data. Configurations where the plasma-flow-impacted Orbiter surfaced downstream of the PDP resulted in generation of a suprathermal ion component. The observations are discussed in terms of a recent model of the mechanism for generation of Shuttle glow.

Reasoner, David L.↗

Millimeter-Wave Imaging Technology Development for Real-Time 2D and 3D Fusion Plasma Diagnostics

Including a one year No-Cost Extension, The University of California, Davis has been funded since 2020 to advance innovative millimeter-wave diagnostics for fusion plasma research. This work includes: (1) Developing and applying cutting-edge System-on-Chip millimeter wave Integrated Circuit (IC) technology for Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometry (MIR) on the DIII-D tokamak and the NSTX-U spherical tokamak. (2) Development of radiation-hardened millimeter-wave chip for diagnostics in harsh environments, utilizing wide bandgap Gallium Nitride (GaN) semiconductors. (3) Integrating forward-modeling synthetic diagnostics to enable advanced, real-time plasma prediction and feedback control. Originally planned as a three-year program (2020–2023), the project was granted a one-year no-cost extension, extending its duration through the end of 2024.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the Use of Spectral Lines Emitted by Carbon Ions for Plasma Diagnostics in Magnetic Fusion Devices

Profiles of the n = 5-6 ({lambda} = 4658 A) and n = 6-7(7726 A) lines emitted by Li-like carbon C{sup +3} ions have been computed for plasma conditions of tokamak and stellarator divertors (N{sub e} = 10{sup 19}-10{sup 21} m{sup -3}, Te = 1-10 eV). The broadening and profiles of these lines are proposed to be used for plasma diagnostic purposes in particular to crosscheck the validity of the plasma parameters determined from the CIV line intensities measured in JT-60U tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗