Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High Performance Computing Management: A Sustainable System Software Approach

The demand for high performance computing (HPC) resources continues to grow, driven by the increasing complexity of modeling and simulation, artificial intelligence (AI), and machine learning (ML) workloads [Porter]. The growing energy consumption demand of these HPC systems is a significant concern, both in terms of operational costs and environmental impact. AI hardware accelerators are expected to reach 1.5% of the world’s power consumption by 2029 [Shah].

97 - MATHEMATICS AND COMPUTING↗

Performance regression manager for large scale systems

System and computer program product to perform an operation comprising generating, based on a first output generated by a first execution instance of a command, a first output file specifying a value of at least one performance metric, wherein the first output file is formatted according to a predefined format, comparing the value of the at least one performance metric in the first output file to a value of the performance metric in a second output file, the second output file having been generated based on a second output generated by a second execution instance of the command, and outputting for display an indication of a result of the comparison of the value of the at least one performance metric of the first output file to the value of the at least one performance metric of the second output file.

97 MATHEMATICS AND COMPUTING↗

Performance regression manager for large scale systems

System and computer program product to perform an operation comprising generating, based on a first output generated by a first execution instance of a command, a first output file specifying a value of at least one performance metric, wherein the first output file is formatted according to a predefined format, comparing the value of the at least one performance metric in the first output file to a value of the performance metric in a second output file, the second output file having been generated based on a second output generated by a second execution instance of the command, and outputting for display an indication of a result of the comparison of the value of the at least one performance metric of the first output file to the value of the at least one performance metric of the second output file.

97 MATHEMATICS AND COMPUTING↗

NS&T Management Observations: Quarterly Performance Analysis

The INL Management Observation Program (MOP) is designed to improve managers and supervisors understanding of work being performed by employees and the barriers impacting their success. The MOP also increases workers understanding of managements’ expectations as they relate to safety, security, quality, and work performance. Management observations (observations) are designed to improve the relationship and trust between employees and managers through increased engagement and interactions between managers and researchers in the field. As part of continuous improvement, NS&T management took initiative to focus on the participation and quality of observations in FY-14. This quarterly report is intended to (a) summarize the participation and quality of management’s observations, (b) assess observations for commonalities or trends related to facility or process barriers impacting research, and (c) provide feedback and make recommendations for improvements NS&T’s MOP.

99 GENERAL AND MISCELLANEOUS↗

Preliminary results from the evaluation of Cockpit Resource Management training - Performance ratings of flightcrews

The first data from the NASA/University of Texas Crew Performance project on the behavior of flightcrews with and without formal training in Cockpit Resource Management (CRM) is reported. Expert observers made detailed ratings of 15 components of crew behavior in both line operations and in full mission simulations. The results indicate that such training in crew coordination concepts increases the percentage of crews rated as above average in performance and decreases the percentage rated as below average. The data also show high and unexpected degrees of variations in rated performance among crews flying different aircraft within the same organization. It was also found that the specific behaviors that triggered observer ratings of above or below average performance differed markedly between organizations. Characteristics of experts' ratings and future research needs are also discussed.

Helmreich, Robert L.↗

High-performance data management for whole slide image analysis in digital pathology

When dealing with giga-pixel digital pathology in whole-slide imaging, a notable proportion of data records holds relevance during each analysis operation. For instance, when deploying an image analysis algorithm on whole-slide images (WSI), the computational bottleneck often lies in the input-output (I/O) system. This is particularly notable as patch-level processing introduces a considerable I/O load onto the computer system. However, this data management process could be further paralleled, given the typical independence of patch-level image processes across different patches. This paper details our endeavors in tackling this data access challenge by implementing the Adaptable IO System version 2 (ADIOS2). Our focus has been constructing and releasing a digital pathology-centric pipeline using ADIOS2, which facilitates streamlined data management across WSIs. Additionally, we’ve developed strategies aimed at curtailing data retrieval times. The performance evaluation encompasses two key scenarios: (1) a pure CPU-based image analysis scenario (“CPU scenario”), and (2) a GPU-based deep learning framework scenario (“GPU scenario”). Our findings reveal noteworthy outcomes. Under the CPU scenario, ADIOS2 showcases an impressive two-fold speed-up compared to the brute-force approach. In the GPU scenario, its performance stands on par with the cutting-edge GPU I/O acceleration framework, NVIDIA Magnum IO GPU Direct Storage (GDS). From what we know, this appears to be among the initial instances, if any, of utilizing ADIOS2 within the field of digital pathology. The source code has been made publicly available at https://github.com/hrlblab/adios.

Wang, Xiao↗

Data management system performance modeling

This paper discusses analytical techniques that have been used to gain a better understanding of the Space Station Freedom's (SSF's) Data Management System (DMS). The DMS is a complex, distributed, real-time computer system that has been redesigned numerous times. The implications of these redesigns have not been fully analyzed. This paper discusses the advantages and disadvantages for static analytical techniques such as Rate Monotonic Analysis (RMA) and also provides a rationale for dynamic modeling. Factors such as system architecture, processor utilization, bus architecture, queuing, etc. are well suited for analysis with a dynamic model. The significance of performance measures for a real-time system are discussed.

Kiser, Larry M.↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2012

The PNNL Annual Site Environmental Report for Calendar Year 2012 was prepared pursuant to the requirements of Department of Energy (DOE) Order 231.1B, "Environment, Safety and Health Reporting" to provide a synopsis of calendar year 2012 information related to environmental management performance and compliance efforts. It summarizes site compliance with federal, state, and local environmental laws, regulations, policies, directives, permits, and orders and environmental management performance.

air quality↗

Performance regression manager for large scale systems

Methods comprising generating, based on a first output generated by a first execution instance of a command, a first output file specifying a value of at least one performance metric, wherein the first output file is formatted according to a predefined format, comparing the value of the at least one performance metric in the first output file to a value of the performance metric in a second output file, the second output file having been generated based on a second output generated by a second execution instance of the command, and outputting for display an indication of a result of the comparison of the value of the at least one performance metric of the first output file to the value of the at least one performance metric of the second output file.

97 MATHEMATICS AND COMPUTING↗

NASA Marshall Space Flight Center Improves Cooling System Performance: Best Management Practice Case Study #10: Cooling Towers (Fact Sheet)

National Aeronautics and Space Administration's (NASA) Marshall Space Flight Center (MSFC) has a longstanding sustainability program that revolves around energy and water efficiency as well as environmental protection. MSFC identified a problematic cooling loop with six separate compressor heat exchangers and a history of poor efficiency. The facility engineering team at MSFC partnered withFlozone Services, Incorporated to implement a comprehensive water treatment platform to improve the overall efficiency of the system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cassini Main Engine Assembly Cover Flight Management and Performance

The Cassini spacecraft has performed its four year Prime Mission at Saturn and is currently in orbit at Saturn performing a two year extended mission. 12Its main engine nozzles are susceptible to impact damage from micrometeoroids and on-orbit dust. The spacecraft has an articulating device known as the Main Engine Assembly (MEA) cover which can close and shield the main engines from these threats. The cover opens to allow for main engine burns that are necessary to maintain the trajectory. Periodically updated analyses of potential on-orbit dust hazard threats have resulted in the need to continue to use the MEA cover beyond its intended use and beyond its design life. This paper provides a detailed Systems-level overview of the flight management of the MEA cover device and its flight performance to date.

Somawardhana, Ruwan P.↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2020. Final Report

The U.S. Department of Energy requires that all its site facilities develop an annual site environmental report to comply with DOE Order 231.1B, Chg 1, and DOE Order 458.1, Admin Chg 4. This report provides a synopsis of calendar year 2020 information related to environmental management performance and compliance efforts at Pacific Northwest National Laboratory. It summarizes site compliance with federal, state, and local environmental laws, regulations, policies, directives, permits, and Orders, and provides environmental management performance benchmarks and their status to the public, regulatory agencies, community officials, Native American tribes, and public interest groups.

54 ENVIRONMENTAL SCIENCES↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2018: Final

The U.S. Department of Energy (DOE) requires that all its site facilities develop an annual site environmental report to comply with DOE Order 231.1B, Chg 1, Environment, Safety and Health Reporting, and DOE Order 458.1, Admin Chg 3, Radiation Protection of the Public and the Environment. This report provides a synopsis of calendar year 2018 information related to environmental management performance and compliance efforts at Pacific Northwest National Laboratory. It summarizes site compliance with federal, state, and local environmental laws, regulations, policies, directives, permits, and Orders, and provides environmental management performance benchmarks and their status to the public, regulatory agencies, community officials, Native American tribes, and public interest groups.

54 ENVIRONMENTAL SCIENCES↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2021 (Final Report)

The U.S. Department of Energy requires that all its site facilities develop an annual site environmental report to comply with DOE Order 231.1B Chg 1 and DOE Order 458.1 Admin Chg 4. This report provides a synopsis of calendar year 2021 information related to environmental management performance and compliance efforts at the Pacific Northwest National Laboratory. It summarizes site compliance with federal, state, and local environmental laws, regulations, policies, directives, permits, and Orders, and provides environmental management performance benchmarks and their status to the public, regulatory agencies, community officials, Native American tribes, and public interest groups.

54 ENVIRONMENTAL SCIENCES↗

Radiation Exposure in Biliary Procedures Performed to Manage Anastomotic Strictures in Pediatric Liver Transplant Recipients: Comparison Between Radiation Exposure Levels Using an Image Intensifier and a Flat-Panel Detector-Based System

Purpose: The aim of this study was to estimate radiation exposure in pediatric liver transplants recipients who underwent biliary interventional procedures and to compare radiation exposure levels between biliary interventional procedures performed using an image intensifier-based angiographic system (IIDS) and a flat panel detector-based interventional system (FPDS). Materials and Methods: We enrolled 34 consecutive pediatric liver transplant recipients with biliary strictures between January 2008 and March 2013 with a total of 170 image-guided procedures. The dose-area product (DAP) and fluoroscopy time was recorded for each procedure. The mean age was 61 months (range 4-192), and mean weight was 17 kg (range 4-41). The procedures were classified into three categories: percutaneous transhepatic cholangiography and biliary catheter placement (n = 40); cholangiography and balloon dilatation (n = 55); and cholangiography and biliary catheter change or removal (n = 75). Ninety-two procedures were performed using an IIDS. Seventy-eight procedures performed after July 2010 were performed using an FPDS. The difference in DAP between the two angiographic systems was compared using Wilcoxon rank-sum test and a multiple linear regression model. Results: Mean DAP in the three categories was significantly greater in the group of procedures performed using the IIDS compared with those performed using the FPDS. Statistical analysis showed a p value = 0.001 for the PTBD group, p = 0.0002 for the cholangiogram and balloon dilatation group, and p = 0.00001 for the group with cholangiogram and biliary catheter change or removal. Conclusion: In our selected cohort of patients, the use of an FPDS decreases radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LLNL SFA OBER–SBR FY19 Program Management and Performance Report: Biogeochemistry of Actinides

Over 2,600 metric tons of plutonium (Pu) are estimated to have been produced worldwide, with approximately 70-90 metric tons added to this inventory each year from spent nuclear fuel. A subset of this Pu inventory has been released into the environment as a result of nuclear weapons production, weapons testing, poor waste management practices, and nuclear accidents. The migration of low levels of Pu released in the environment has been documented on the scale of kilometers. Due to its long half-life, toxicity, and its ability to migrate, Pu represents a potentially significant risk to humankind and the environment. Their fate depends on the nature of the release, the biogeochemical processes controlling mobilization, and the eventual exposure pathways. Understanding their behavior in the environment is critical for managing environmental contamination and planning for the safe, long-term isolation of nuclear waste from the biosphere.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Usability and Workload with Paper Strips as Compared to Virtual Flight Strips Used for Ramp Operations

This paper describes an experiment designed to compare the use of paper strips with the use of a new user interface, the Ramp Traffic Console (RTC), designed for use by ramp controllers to be used in place of paper strips. A Human-In-the-Loop (HITL) experiment was performed as the fifth study in a series of six HITL simulation experiments designed to evaluate a concept that provided advisories to the users. The RTC was designed to be used as a Decision Support Tool (DST) that provided advisories to ramp controllers regarding metering or pushback such that most of the delay was taken at the gate to save fuel and emissions. In addition to being a DST, an added benefit of the RTC is that it can provide real-time updates of flight data, airport and airspace status to the controller including Traffic Management Initiatives (TMI). The RTC was designed as new user interface that displays virtual strips on a terminal map drawn on a 27-inch touch screen monitor. The RTC was used in some conditions of the experiment by ramp controllers in place of paper strips and paper maps in the HITL environment. In other conditions the controllers were given paper strips and paper maps similar to what they currently use at Charlotte Douglas International Airport (CLT). The study described here, evaluated the use of the virtual strips displayed on the RTC as compared to the use of paper strips and paper map, using current ramp tower controllers at CLT as participants. The research question being asked was - How does management of ramp traffic affect user workload and usability ratings while using RTC to manage traffic in the ramp verses using paper strips? Workload for our purposes is defined by four components of the NASA-TLX (Task Load Index). Usability was assessed with two sets of usability questions - One set of usability questions addressed traffic management performance and the other set addressed issues of resources and efficiency. Both Post Run and Post Study questionnaire responses were gathered and the results were analyzed to assess controller workload and usability ratings under both conditions, virtual strips shown on RTC and Paper Strips. The results indicate that controllers perceived lower workload while using virtual strips displayed on RTC to manage ramp traffic. Usability ratings for Traffic management performance questions are lower in the virtual strip/RTC condition than in the paper strip condition showing a preference for RTC over Paper. Usability ratings for Resources and efficiency questions show mixed results. Additionally, the Post Study Questions show preference for RTC over paper strips. Results of this data analysis will be presented in this paper. This DST evaluation was an important step in researching and improving the tool, which was planned to be deployed in the field.

Aviation Decision Support Tools↗