Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peaking capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Registration of ‘Independence’ switchgrass

Switchgrass (Panicum virgatum L.), a valuable forage and bioenergy crop, is established more easily than other native perennial warm-season grasses, but its establishment is still slower than that of annual crops. Vigorous switchgrass establishment is crucial for achieving its full potential yield and for effectively competing with weeds for water and nutrient availability. To satisfy this demand, ‘Independence’ (Reg. no. CV-295, PI 704577) switchgrass was developed at the University of Illinois at Urbana-Champaign. Independence was selected for establishment vigor, winter survivorship, and high biomass yield for two cycles from ‘Kanlow’. Here, it is characterized by rapid establishment, robust seedling growth, and the capacity to achieve peak production by the second year. Independence is well adapted to USDA hardiness zones 5b–7b. In field experiments conducted from 2016 to 2017, averaged over seven locations and all years, Independence annually yielded 13 Mg ha –1 of biomass, outperforming ‘Cave-in-Rock’ by 31%, ‘Liberty’ by 15%, ‘Shawnee’ by 42%, ‘Summer’ by 81%, and ‘Sunburst’ by 129%. In wet marginal sites in Illinois from 2020 to 2023, Independence exhibited an average biomass yield of 12 Mg ha –1 , outperforming Shawnee by 31%, Liberty by 27%, and Kanlow by 19%, indicating its potential use on less productive land for annual crops. Independence was publicly released by the University of Illinois at Urbana-Champaign in October 2021.

09 BIOMASS FUELS↗

Temporal and spatial separations between spin glass and short-range order

Broken-symmetry-induced order parameters account for many phenomena in physics. For spin glasses, this framework dictates the theoretical construction, whereas experiments have only established dynamical behaviors but not the physical entity. Experimental techniques have limitations when the spin glass is probed as an isolated state. Here, we create an evolution from a long-range order using well-controlled non-magnetic substitution on a sublattice. Neutron magnetic diffuse scattering of pico-second timescale reveals that the dynamics of short- and long-range order formation are not affected by disorder, but their spatial ranges are. Across all specimens, the inflection point of spin correlation length’s temperature dependence fully matches with the peak in heat capacity, while spin glass can freeze at millisecond timescale either above or below this characteristic temperature of spin-order formation. Our results identify the spin glass as single, uncorrelated spins at domain walls between spin clusters, and an uncorrelated coexistence of the two.

Dronova, Margarita G [Okinawa Institute of Science↗

Structure and properties of densified silica glass: characterizing the order within disorder

The broken symmetry in the atomic-scale ordering of glassy versus crystalline solids leads to a daunting challenge to provide suitable metrics for describing the order within disorder, especially on length scales beyond the nearest neighbor that are characterized by rich structural complexity. Here, we address this challenge for silica, a canonical network-forming glass, by using hot versus cold compression to (i) systematically increase the structural ordering after densification and (ii) prepare two glasses with the same high-density but contrasting structures. The structure was measured by high-energy X-ray and neutron diffraction, and atomistic models were generated that reproduce the experimental results. The vibrational and thermodynamic properties of the glasses were probed by using inelastic neutron scattering and calorimetry, respectively. Traditional measures of amorphous structures show relatively subtle changes upon compacting the glass. The method of persistent homology identifies, however, distinct features in the network topology that change as the initially open structure of the glass is collapsed. The results for the same high-density glasses show that the nature of structural disorder does impact the heat capacity and boson peak in the low-frequency dynamical spectra. Densification is discussed in terms of the loss of locally favored tetrahedral structures comprising oxygen-decorated SiSi 4<:sub> tetrahedra.

36 MATERIALS SCIENCE↗

Modeling the Nucleation and Growth of Lead Sulfate Particles on Lead Electrodes

Lead-acid batteries (LABs) play a pivotal role in the energy storage sector with applications spanning from starting-lighting-ignition batteries to grid energy storage. Passivation of lead negative electrodes by PbSO 4 particles is a fundamental mechanism limiting the performance of LAB. In this regard, an electrochemical model is developed that simulates the nucleation and growth (N&G) dynamics of PbSO 4 particles on a flat lead electrode, responsible for its passivation. The model considers the electrochemical reactions between lead electrode and sulfuric acid, N&G of PbSO 4 particles, passivation of the lead surface, and the ternary transport of PbSO 4 (aq), bisulfate, and protons in H 2 SO 4 electrolyte. The model is validated with a dataset of cyclic voltammetry (CV) responses collected at several scan rates and H 2 SO 4 concentrations. The model shows remarkable qualitative and quantitative agreement with the experimental data including CV peak features, discharge capacity, and particle size. The model was employed to explore key N&G quantities, such as supersaturation, nucleation rate, particle count, growth rate, particle size, and surface coverage, and to examine how their interactions influence electrode utilization. Parametric studies were also conducted to evaluate how scan rates and acid concentrations influence the previously mentioned N&G quantities and, subsequently, the utilization of the electrode.

25 ENERGY STORAGE↗

Climate Influences on Capacity Expansion Planning with Application to the Western U.S

Electric power system planners utilize a variety of planning tools to inform decisions concerning generation and transmission additions to the electric grid, the need for operational changes, and to evaluate potential stressors on the system. Numerous factors contribute to the planning process including projected fuel and technology costs, policy and load profiles. There is also a growing recognition of the interdependency of the electric grid with other natural and engineered systems. Here we explore how future climate change and hydropower operability might influence decisions related to electricity capacity expansion planning and operations. To do so we assemble a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on future water supply for thermoelectric and hydropower generation. Separately, temperature impacts on electricity load are evaluated. Together, these climate factors spatially constrain a capacity expansion model that projects generation and transmission additions to the grid. The projected new capacity-builds are then evaluated on their operations, reliability, and cost under average and extreme climate conditions using production cost modeling. This coupled framework is demonstrated on the electric grid in the Western U.S., supporting capacity expansion planning by WECC, the North American Electric Reliability Corporation (NERC) regional entity responsible for reliability assurance of the Western Interconnection. This region was selected in part because the West is unique in that it has high potential for renewable penetrations and is experiencing large retirements/displacements of baseload resources, primarily coal, leading to possible operational challenges in terms of changing resource mix and the need for resource flexibility. Toward this challenge, planning scenarios encompass a range of alternative energy, climate and drought futures. In this context we explore answers to two strategic questions: 1) How does changing climate influence electricity expansion planning (generation and transmission) and future operations, including type and capacity of new builds, system reliability, cost and environmental impacts? 2) How does the representation of hydropower in the modeling framework influence the evaluation of bulk power system operations? Results indicate that climate has a measurable influence on recommendations concerning the capacity, type and location of new generation and transmission additions, with up to 17 GW additional capacity needed by 2038 to meet peak loads (~6.6% increase over capacity-builds based on historical climate). The extent of additional infrastructure needs is strongly influenced by future water availability for hydropower and the potential deployment of demand response technologies. Systems designed for future climate conditions were found to maintain high system reliability under a range of electricity and water availability scenarios (including significant drought), with minimal system curtailments. Additional capacity needs due to higher load tend to increase cumulative 20-year investment and operating costs by $\$$5-$\$$17 billion and generation costs increase by 9 to 19%. Finally, changing the representation of hydropower flexibility has a relatively small influence on capacity expansion in the Western Interconnection through 2038, but hydropower flexibility impacts generation costs to a similar extent as climate.

13 HYDRO ENERGY↗

Combined Heat and Power Technology Fact Sheet Series: Thermal Energy Storage

This fact sheet provides an overview of thermal energy storage (TES) technologies, which heat or cool a storage medium and, when needed, deliver the stored thermal energy to meet heating or cooling needs. TES systems are used in commercial buildings, industrial processes, and district energy installations to deliver stored thermal energy during peak demand periods, thereby reducing peak energy use. TES systems are often integrated with electric or absorption chillers to reduce peak electricity costs and, in the case of new construction, to reduce capital costs by optimizing chiller size. TES technologies can support sites that have either renewable or fossil power generation, including combined heat and power (CHP) installations. With CHP, TES can help optimize equipment size by reducing the required peak CHP thermal capacity and increasing annual CHP usage. TES can also provide turbine inlet cooling for gas turbines used in CHP applications, which increases power production in hot ambient conditions.

Combined Heat and Power, CHP, Thermal Energy, Tech↗

Least-Cost Pathways for India's Electric Power Sector

The Government of India has a target of deploying 175 GW from renewable energy by 2022 and 40% of electricity capacity from renewable energy by 2030 and has indicated that ambitions for 2030 could be higher. Rapid changes in technology costs and performance could drive further deployment of wind and solar capacity beyond these policy targets. Increased deployment of variable renewable energy (VRE) raises new questions for power system planning regarding the optimal siting of generation capacity, trade-offs between generation and transmission infrastructure, and system flexibility needs. This study aims to evaluate least-cost pathways for India's electric power system over the period 2017-2047. Uniquely, this work considers an expanded planning horizon and range of scenarios not previously analyzed in national planning studies in India. The data collection and model design processes undertaken for this study provides a framework for recurring planning studies. This study finds anticipated changes in electricity demand and component costs can drive a significant shift in India's future electricity supply and how this system will be operated. In the Base scenario, the share of generation from VRE reaches 54% by 2047. Reducing the capital cost of wind has a larger impact on VRE penetration than reducing the capital cost of solar PV or battery storage. In the lowest wind cost scenario (40% capital cost decline by 2047 relative to the Base scenario), the penetration of VRE in the generation mix reaches 722%, exceeding the penetration levels achieved when the cost of battery storage or solar PV are reduced by an even greater 50%. In a future system with high penetrations of RE, capacity additions are driven by the coincidence of demand and RE generation rather than peak demand alone. This study finds the system could have surplus capacity during the peak demand months of July–September because this period corresponds to periods with high wind speeds and more wind generation available to meet peak demand. By contrast, new capacity is needed to meet demand during moderate demand months of October–November when output from wind plants falls more than 75% nationally compared to the previous two months. Finally, the success for gas for electricity production may depend on cost competitiveness rather than fuel availability. Increasing the amount of gas available for electricity production had no significant impact on the capacity or generation mix by 2047, as determined from a scenario that significantly increases fuel availability throughout the planning horizon. In fact, over 80% of new gas fuel available for the power sector remains unused. This suggests the high cost of gas plant operations relative to other technologies may constrain the expansion of gas generation in India more than fuel availability.

14 SOLAR ENERGY↗

The Peaking Potential of Long-Duration Energy Storage in the United States Power System

In this work, we investigated the peaking potential for storage with durations of 4 h up to durations of 168 h (1 week). The peaking potential for a given storage duration is the amount of storage that can be added to a power system before that storage can no longer serve the peak net demand period at full rated capacity. We found that for the United States, 168 h of storage would be sufficient to serve about 27 % of peak demand, or about 215 GW in the current system. However, more than one-half of this amount could be served by storage with 12 h or less of capacity. As deployment of wind and solar grows, the peaking potential increases significantly, and under decarbonization scenarios, approximately one-half of the peak demand could be served by storage of up to 168 h; but again, the majority of this storage could be with durations of up to 12 h. The potential is also driven by the mix of wind and solar, and by storage efficiency, with the deployment of solar having the largest impact for both storage peaking potential and the mix of durations.

capacity expansion↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗

Evolution of the cyclotron mass with doping in La 2–x Sr x CuO 4

The recent observation of cyclotron resonance in optimally doped La 2–x Sr x CuO 4 using time-domain THz spectroscopy in high magnetic field has given new possibilities for the study of cuprate superconductors. One can measure the cyclotron mass in the more disordered cuprates possessing short scattering times, therefore expanding the study to materials and dopings in which quantum oscillations have not been observed. In this paper we present the measurement of the carrier mass of the hole-doped cuprate La 2–x Sr x CuO 4 across a range of dopings spanning from the slightly underdoped (p=0.13) to highly overdoped (p=0.26), near the termination of the superconducting dome. These results reveal a systematic increase of m c with doping, up to values greater than 13 times the bare electron mass. This is in contrast with the masses extracted from the heat capacity, which show a peak near the pseudogap critical point p* and/or Lifshitz transition. The cyclotron frequency is linear in field up to 31 T for all dopings, giving no evidence for field-induced Fermi surface reconstructions. The cyclotron mass is found to be positive for all dopings, but with a magnitude systematically below the heat-capacity mass for under and optimally doped samples, while exceeding it for overdoped samples. Among other aspects, these results are surprising as photoemission reveals a Lifshitz transition in the middle of our doping range and the sign of the cyclotron mass determined from a finite-frequency resonance is, in conventional theories, a topological quantity only sensitive to whether or not the Fermi surface is closed around holes or electrons. We see no sign of a divergence of the mass near p* nor near the Lifshitz transition, showing that any singularity, if it exists, is not strong enough to affect the cyclotron mass.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Collinear antiferromagnetic order in a quasi-two-dimensional triangular lattice compound DyNiAl 4 Ge 2

The two-dimensional magnetic triangular lattice, with rare-earth local moments coupled through long-range interactions and hosting strong spin-orbit coupling, serves as an ideal platform for exploring novel quantum phenomena. Here, we report the physical properties of DyNiAl 4 Ge 2 single crystals through comprehensive structural, magnetic, heat capacity, electrical transport, and neutron powder diffraction measurements. DyNiAl 4 Ge 2 crystallizes in a trigonal lattice with the space group $R\bar{3}m$, where Dy atoms form two-dimensional triangular lattice layers within the 𝑎𝑏 plane and stack along the 𝑐 axis. Magnetic susceptibility measurement reveals a magnetic phase transition at 𝑇 𝑁 = 9.0 K, further confirmed by the 𝜆-shaped peak in the heat capacity curve. The obtained temperature-magnetic field phase diagram is relatively simple compared to other isostructural compounds, suggesting the absence of magnetic frustration. This is further evidenced by neutron powder diffraction, which shows a collinear antiferromagnetic ground state with a propagation vector 𝒌 = (0, 0, 1.5), implying the absence of magnetic frustration in DyNiAl 4 Ge 2 . In this magnetic structure, Dy moments are aligned ferromagnetically within each triangular layer and arranged antiferromagnetically between adjacent layers along the 𝑐 axis. In conclusion, our results establish DyNiAl 4 Ge 2 as a model system for understanding the interplay between RKKY interaction and geometrical frustration in this family of compounds.

Wu, HengHeng [Chinese Academy of Sciences (CAS), S↗

Reference Station Design for Heavy-Duty Vehicles

Five alternative design configurations for a heavy-duty hydrogen refueling truck stop are detailed in this work. Each of the station concepts provides fast, 5-minute, 50 kg fills of up to 4 vehicles simultaneously, with a station capacity of 4200 kg/day. Two on-site production stations using PEM electrolysis are considered: one with off-peak production of the daily capacity; and one with on-demand production of hydrogen during vehicle refueling. Three delivered liquid hydrogen station concepts are considered: one with the same, high-pressure cascade storage system for dispensing as the electrolysis supplied stations, with low-pressure vaporization of the liquid hydrogen and pressurization via a compressor; and two with on-demand pressurization: one by low-pressure vaporization and compressors; and one with a cryogenic pump and high-pressure vaporization. Design, economic, and operational considerations for each of the components needed in these station concepts is provided. Of all the station concepts, the delivered liquid station with a low-pressure vaporizer and a cascade dispensing system has the lowest capital costs and equipment footprint, but the second highest operating costs primarily due to high costs for liquid hydrogen delivery. The lowest operating cost station is that with on-site production via PEM electrolysis at off-peak hours with a cascade delivery system. The low-pressure buffer storage system and electrolyzers have a large footprint and considerable capital costs, but could result in a low total cost of ownership, depending on the design timeline. The liquid hydrogen station with a cryo-pump has moderate capital costs, the lowest operating costs of the three delivered hydrogen stations, and the same small equipment footprint as the delivered liquid, cascade dispensing system. As cryogenic pumping technology improves and the capital costs for these pumps decreases, this station concept will become even more favorable. Three-dimensional renderings of the five station concepts provide station designers with a starting point for the development of heavy-duty refueling stations.

08 HYDROGEN↗

From a conventional ferromagnetism to a frustrated magnetism: An unexpected role of Fe in Nd(Al 1-x Fe x ) 2 (x ≤ 0.2)

The structure and magnetic properties of Nd(Al 1-x Fe x ) 2 alloys with x = 0, 0.05, 0.1 and 0.2, which adopt cubic MgCu 2 -type structure with space group Fd3¯m, are studied using x-ray powder diffraction, static and dynamic magnetization, and calorimetric measurements. The lattice constant decreases linearly with increasing Fe content from 8.0106(4) Å to 7.9044(4) Å. Large thermal irreversibilities between zero-field-cooled and field-cooled conditions are observed for all substituted samples. Here, the magnetic transition temperatures exhibit a minimum for x = 0.1, and coercive fields at 2 K increase from 70 Oe for x = 0 to 6.3 kOe for x = 0.2. The absence of λ-type peak in the heat capacity data, frequency dependence of ac magnetic susceptibility, and memory effects indicate formation of a cluster-glass magnetic state when x ≥ 0.1.

36 MATERIALS SCIENCE↗

Lattice Mie resonances and emissivity enhancement in mid-infrared iron pyrite metasurfaces

High-refractive-index antennas with characteristic dimensions comparable to wavelength have a remarkable ability to support pronounces electric and magnetic dipole resonances. Furthermore, periodic arrangements of such resonant antennas result in narrow and strong lattice resonances facilitated by the lattice. We design iron pyrite antennas operating in the mid-infrared spectral range due to the material’s low-energy bandgap and high refractive index. We utilize Kirchhoff’s law, stating that emissivity and absorptance are equal to each other in equilibrium, and we apply it to improve the thermal properties of the iron pyrite metasurface. Through the excitation of collective resonances and manipulation of the antenna lattice’s period, we demonstrate our capacity to control emissivity peaks. These peaks stem from the resonant excitation of electric and magnetic dipoles within proximity to the Rayleigh anomalies. In the lattice of truncated-cone antennas, we observe Rabi splitting of electric and magnetic dipole lattice resonances originating from the antennas’ broken symmetry. We demonstrate that the truncated-cone antenna lattices support strong out-of-plane magnetic dipole lattice resonances at oblique incidence. We show that the truncated-cone antennas, as opposed to disks or cones, facilitate a particularly strong resonance and bound state in the continuum at the normal incidence. Our work demonstrates the effective manipulation of emissivity peaks in iron pyrite metasurfaces through controlled lattice resonances and antenna design, offering promising avenues for mid-infrared spectral engineering.

Islam, Md Sakibul↗

High-Efficiency, Medium-Voltage-Input, Solid-State-Transformer-Based 400-kW/1000V/400A Extreme Fast Charger for Electric Vehicles

Range anxiety and long battery charging time continue to be critical challenges to mass adaptation of EVs. A major identified gap to wider adoption of BEVs is the ability and availability to refuel quickly or to fast charge. Studies have shown that in areas where drivers have access to 50-kW or 120-kW fast charge stations, annual electric vehicle (EV) miles traveled (i.e., eVMT) increased by over 25%, even in cases where fast charging was used for 1% to 5% of total charging events. Charge stations of higher power not only alleviate the “range anxiety” and reduce the driver’s waiting time, but also requires less investment. Michigan Energy Office completed a study in early 2019 titled “Electric Vehicle Charger Placement Optimization in Michigan: Phase I – Highways”. This study finds a system with 150kW chargers, though more expensive individually, actually has lower total system cost when compared to a 50kW charging system when serving the same battery size EV. To be truly competitive to the ICEV refueling experience, even higher power stations are necessary. However, high power charge stations would create large power draws from the grid. If this occurs during peak demand periods, grid capacity could be overloaded. This problem needs to be addressed to reduce the impact on the electric utility infrastructure. The main goal of this project is to develop a 400-kW/400-A XFC system targeting total efficiency of 96.5 percent from the MVAC grid to a vehicle. The novel SST power cell topology, combined with a new silicon carbide (SiC) MOSFET device, enables a 3.5 percent improvement in system efficiency, a 50-percent smaller equipment footprint, and four times less weight than today’s DCFC systems. The SST technology would directly utilize MVAC at 4.8-kV or 13.2-kV. This would eliminate the line frequency transformer (LFT), which steps down medium-voltage AC to 3-Phase 480-V line-to-line voltage in current DCFC systems.

42 ENGINEERING↗

Quantum Oscillations in the Heat Capacity of Kondo Insulator YbB 12

Here, we observe magnetic quantum oscillations in the heat capacity of the Kondo insulator YbB 12 . The frequency of these oscillations, 𝐹 = 700 T, agrees with that from magnetoresistance and torque magnetometry experiments for 𝜇 0 ⁢𝐻 >35 T in the Kondo insulating phase. Remarkably, the quantum-oscillation amplitudes in the heat capacity are substantial, with Δ⁢$\tilde{C}/T$ ≈ 0.5 mJ mol −1 K −2 at 0.8 K, accounting for 13% of the known linear heat-capacity coefficient 𝛾. Double-peak structures of quantum-oscillation amplitudes due to the distribution function of fermions were identified and used to determine the value of the effective mass from the heat capacity, which agrees well with that from torque magnetometry. These observations support bulk charge-neutral fermions contributing to the quantum oscillations in YbB 12 .

36 MATERIALS SCIENCE↗

Water and Climate Impacts on ERCOT Long-Term Systems Assessment

Water and climate change pose many potential challenges to the electric power system. Substantial water is withdrawn every day to support thermoelectric power generating unit operations, and changes to water supply have the potential to affect generation dispatch. Climate change can accelerate growing demand for electricity, which can necessitate additional generating capacity, often in locations with limited water supply. Drought conditions also threaten thermoelectric power plant operations due to streamflow and reservoir levels dropping below intake structures, or water temperatures exceeding a power plants' permitted operating conditions. Here we explore how future climate change might influence decisions related to electricity capacity expansion planning in Electric Reliability Council of Texas (ERCOT) using a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on the future water supply for thermoelectric and hydropower generation for four future climate projections. Separately, temperature impacts on electricity load are evaluated for these scenarios. These climate impacts are applied to five alternative electricity futures in an electricity capacity expansion model that projects future generation and transmission capacity additions in ERCOT. Results indicate that climate has a measurable influence on future generation and transmission capacity needs, with temperature-driven increases in peak and average load resulting in 5-15 GW additional generating capacity and up to 1 GW additional transmission capacity. Additional capacity is a diverse mix of PV, natural gas, and wind, depending on the makeup of economic, policy and technology assumptions. Climate impacts increase total system costs 2-5%, while the marginal cost of energy and emissions are not affected substantially by climate change effects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗