Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pdv”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

LA-R43S6-L1 Postshot Report [Slides]

The Ranchero LA-R43S6-L1 test (formerly referred to as LA-43S-L1. The R specifically designates it is a Ranchero device and the 6 indicates a 6” high explosive charge diameter in anticipation of using larger diameters in the future.) was conducted on 3/8/17 with good success. The experiment was the first test of a “Swooped” Ranchero flux compression generator (FCG), and the load for the test was an aluminum imploding liner. In addition to the swoop, the stator was anodized to provide an insulating layer instead of one or more layers of polyethylene as had been the case for all earlier Ranchero tests. Using the Firing point TA-39-88 capacitor bank, 3.5 MA was delivered to the FCG for the initial magnetic field, and 36.4 MA were delivered to the load having an initial inductance of 2.5 nH. Implosion speeds over 1.1 cm/us were recorded, which exceeds previous LANL solid liner experimental results. The test was diagnosed with 18 PDV channels, 12 of which recorded liner implosion data, and the other 6 of which tracked the FCG armature during flux compression. These armature expansion data recorded during flux compression are the first of their kind, and it was previously unknown, due to unknown effects of the SF 6 in the flux compression volume, whether or not the expansion could be recorded using the PDV technique. Post shot 2D MHD calculations employed a complete external circuit model, and an improved flux diffusion model not available prior to the test. Results from these simulations show very good agreement with the experimental result. Four PDV channels recorded the liner implosion viewed radially outward from the center of the liner. All four of these probes recorded implosion velocities greater that 1 cm/µs, with the cylindrical center displaced by ~2 mm from actual center. Four PDV channels looked at +10° angles from the CMU wall, and four looked at -10° angles. A glide plane interaction is shown moving toward the center of the liner in MHD calculations, and PDV probes provide confirmation. The high explosive (HE) in the LA-R43S6-L1 test was PBX 9501 which had to be glued together in many pieces, and the test was preceded by a camera test to verify that the PBX 9501 could be assembled with acceptable tolerance in glue joints to prevent severing the armature during expansion. The camera test verified an acceptable armature performance, and results are given in complete detail in a post shot report LA-UR-19-20124, and summarized here. This report provides complete detail of the considerable body of data obtained on the test and in the post shot calculations. It is prepared in Power Point for ease of preparation and future review. Shot documentation available in the LANL on-line library are included as references, and non-referenceable documents will be cited and stored in an LA- R43S6-L1 post shot folder stored on an M-6 shared drive. Fabrication drawings are also maintained in an M-6 shared drive and paper files are available from M-6 personnel. This report will be maintained as a PowerPoint document on the shared drive, as well, since included movies will play and graphs from Excel files retain information in the PowerPoint versions. PDF versions are required for clearance and are not to large to send by e-mail.

42 ENGINEERING↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stress field measurements using quantitative schlieren

Quantitative schlieren analysis is extended here to optically transparent solids in quasi-static and dynamic experiments to measure stress distributions. The quasi-static experiments in polymethyl methacrylate (PMMA) compared refraction angles and stress gradients calculated from schlieren images to the analytical Flamant solution of a line load on a half-space. The quantitative schlieren measurements of the stress field in the thin sample with a load compared well to the analytical solution. The analysis method was then extended to explosive induced shock waves in PMMA. The explosive induced response of PMMA was experimentally studied using high-speed schlieren to visualize the shock propagation in conjunction with Photon Doppler Velocimetry (PDV) to record surface velocity histories. The stress state estimated from the schlieren images was compared to the stress calculated from the PDV measurements. High-speed imaging limitations caused the shock wave to not be fully resolved in the images, but was resolved in the PDV measurement. The stress state behind the shock calculated from the high-speed images followed a similar trend to the stress calculated from the PDV measurements.

Physics↗

A Bayesian approach to time-domain photonic Doppler velocimetry analysis

Photonic Doppler velocimetry (PDV) is an established technique for measuring the velocities of fast-moving surfaces in high-energy-density experiments. In the standard approach to PDV analysis, the short-time Fourier transform (STFT) is used to generate a spectrogram from which the velocity history of the target is inferred. The user chooses the form, duration, and separation of the window function. Here, in this study, we present a Bayesian approach to infer the velocity directly from the PDV oscilloscope trace, without using the spectrogram for analysis. This is clearly a difficult inference problem due to the highly periodic nature of the data, but we find that with carefully chosen prior distributions for the model parameters, we can accurately recover the injected velocity from synthetic data. We validate this method using PDV data collected at the STAR two-stage light gas gun at Sandia National Laboratories, recovering shock-front velocities in quartz that are consistent with those inferred using the STFT-based approach and are interpolated across regions of low signal-to-noise data. Although this method does not rely on the same user choices as the STFT, we caution that it can be prone to misspecification if the chosen model is not sufficient to capture the velocity behavior. Analysis using posterior predictive checks can be used to establish whether a better model is required, although more complex models come with additional computational cost, often taking more than several hours to converge when sampling the Bayesian posterior. We, therefore, recommend it be viewed as a complementary method to that of the STFT-based approach.

Allison, James R. [First Light Fusion Ltd., Yarnto↗

Simulations of Sweeping Wave Propagation in a Boron Carbide Plate

In February 2020, experiments were conducted at Los Alamos National Laboratory measuring the propagation of a sweeping wave through a plate of boron carbide which was induced by detonating an adjacent charge of high explosive. Six such shots were red and in each case progress of the wave along the exposed surface of the plate was tracked using photon doppler velocimetry (PDV). In this report we discuss calculations performed using the Lagrangian hydrocode FLAG to model data taken from these experiments. We discuss the models chosen for the different experimental components, the choice of mesh (focusing on, both, two- and three-dimensional geometries), and compare the results from these calculations to experimentally-extracted PDV traces. Notably, we find that the PDV traces for this experiment are most faithfully reproduced using the full three-dimensional geometry, even when the mesh resolution for the three-dimensional calculations was significantly lower than the resolution for the corresponding two-dimensional calculations. We attribute this to the geometry of the experimental setup. Moreover, we find only negligible differences for the PDV traces obtained using the sesame table equation of state for boron carbide and the Gruneisen equation of state.

36 MATERIALS SCIENCE↗

Laser Wavelength Shift from Splitters and Switches

The Detonation Science and Technology Group (Q-6) operates several photon Doppler velocimetry (PDV) systems as a diagnostic tool for measuring velocities in the 1–10 km/s range during high explosive (HE) detonation experiments. Q-6 uses “heterodyne” PDV systems that are produced by Traverse Solutions and Instrumentation, LLC (TS&I). These heterodyne systems combine wavelength (WL) tunable source and “reference” lasers with a WL offset of 10–100 pm from each other. Properly setting the source and reference WLs for an experiment can be critical for collecting the desired experimental data. The tunable lasers report WL readings in their control software, but these readings are based on a lookup table from a temperature reading and are not able to be calibrated. Therefore, recent test fire programs that require PDV as a diagnostic have also implemented requirements for monitoring the WL of the tunable lasers using a precision WL meter. To monitor the WL of several PDV lasers without disconnecting any patch fibers form the experimental setup, Q-6 developed a system splitters with a coupling ratio (%) of 99:1 and an optical switch with the switch output going to a single WL meter. A brief experiment was developed to determine if the splitters and/or switch introduced any WL bias into the readings. The purpose of this report is to document the system, the experiment, and its results.

42 ENGINEERING↗

Development of spatially and temporally resolved electron density measurements for the assessment of radiation hydrodynamics simulations of laboratory X-ray photoionized plasmas

The photoionized plasma gas cell experiment is an established platform we use to make at-parameter (ξ > > 1 ergs cm s –1 ) measurements of plasma properties with application to high-energy astrophysical systems. We model the experiments with 1D radiation hydrodynamics simulations using the HELIOS-CR code to inform our understanding and assist in the interpretation of results. The simulations predict that the bulk of the plasma is in a quasi-uniform and hydrodynamically unperturbed state throughout the duration of the experiment. To evaluate this prediction, we introduced a photonic Doppler velocimetry (PDV) diagnostic to measure spatially and temporally resolved plasma electron density. The initial measurements were successful but had limitations that made model-data comparisons challenging. To address this, we re-designed the gas cell PDV diagnostic and doubled the number of measurement locations to sample across two thirds of the depth of the cell. We also present a comparison of the results from the upgraded PDV diagnostic to the HELIOS-CR simulations for the first time. As a result, the experimental data confirms the prediction of an unperturbed region in the bulk of the plasma but reveals discrepancies in the time evolution and spatial distribution of the simulated electron density.

79 ASTRONOMY AND ASTROPHYSICS↗

Photonic Doppler velocimetry of ohmically exploded aluminum surfaces

Photonic Doppler Velocimetry (PDV) was used to measure the exploding surface of coated metal driven by lineal current density increasing at 3 × 10 15 A/m/s. Here, aluminum-6061 rods were coated with three thicknesses (5, 17, and 41 μm) of Parylene-N and driven to 850 kA in approximately 100 ns, with the metal thicker than the skin depth. According to PDV, the metal surface melts at 85 ± 13 T and expands with a constant acceleration. Then, at surface magnetic field 140-180 T, the metal acceleration begins to increase in time. Later, plasma forms on, and is correlated with PDV signal loss from, uncoated aluminum rods, 5-μm-coated rods, and 17-μm-coated rods, while no evidence suggests plasma forms on 41-μm-coated metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2024 Milestone Report: Site 300 mPDV Optical Fiducials

In the early 2000s Photon Doppler Velocimetry (PDV) replaced the Fabry-Perot many beam system1 and has since become ubiquitous across dynamic experimental platforms to measure velocity and event times such as shock breakout, key variables for high pressure physics research. The advent of optically multiplexed oscilloscope channels to create multiplexed PDV (mPDV) increased portability and reduced price per data point. However, these advantages came with the cost of additional fielding complexity and thermally induced timing drift, which directly affects the ability to use PDV for high precision time measurement. Controlling the temperature or incorporating optical fiducials allows researchers to characterize, reduce, and correct this thermal drift in analysis. Our implemented optical fiducial or “timing marker” allows us to reduce thermal drift uncertainty from the 10s of nanoseconds down to the 100s of picoseconds with minimal added complexity to existing systems. The implementation of this timing marker normalizes uncertainty across optical delays, brings our facility cross timing into the sub nanosecond regime and lets us identify/study anomalies in our data. This improvement increases experiment reliability and quality enabling a new class of high precision experiments at S300.

42 ENGINEERING↗

Velocity Extraction Using Complete Time-Domain Waveform Data and Audio Machine Learning

We developed a new machine learning-based tool for extracting information from interferometry measurements: MIDWAZE (Modular Interferometry Direct Waveform AnalyZEr). This paper showcases MIDWAZE’s ability to extract an object’s velocity information from Photonic Doppler Velocimetry (PDV) data at near-human accuracy with little to no human intervention. MIDWAZE can extract velocities roughly 350 times as fast as a human analyst "rushing" to complete their extractions, with similar extraction accuracy. MIDWAZE’s most outstanding feature is that it operates directly in waveform/temporal space, freeing analysis from certain limitations imposed by traditional spectrogram-based approaches and opening the way to "phase aware" PDV analysis. MIDWAZE also has limited ability to discriminate between different solid objects, which we develop as a first step towards automated discrimination of different kinds of objects such as ejecta clouds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shock Response of Polymethyl Methacrylate (PMMA) Under Explosive Loading

Abstract The dynamic response of polymethyl methacrylate (PMMA) is well understood for one-dimensional planar impact shocks, but limited research has been performed on the response of PMMA under spherical shock loading. In this work, the shock decay of an explosively-driven shock wave into PMMA was experimentally measured. PMMA cubes of various geometries were explosively loaded with an RP-80 detonator to produce the explosive shock wave. High-speed schlieren imaging was implemented to measure the explosively-driven shock wave velocity throughout the PMMA cubes. Photon Doppler velocimetry (PDV) was used to measure the particle velocity imparted by the shock wave at the surface of the cubes. The material shock response was studied at distances from 21.91 to 133.3 mm from the explosive source. The particle velocity history measured by PDV was compared to the wave profile visualized in the high-speed images. The shock wave pulse amplitude decreased with increased distance from the source. The conducted experiments extend the PMMA shock Hugoniot relating to the lower shock and particle velocity regime.

Torres, S. M. (ORCID:0009000287177206)↗

Efficacy of Gadolinium Gallium Garnet (GGG) as a High-Impedance Optical Window for Shock Wave Experiments

We conducted a series of plate impact experiments to examine the efficacy of < 111>-oriented gadolinium gallium garnet (GGG) single crystals as high-impedance optical window for Photonic Doppler velocimetry (PDV) under shock and double-shock loading. At ~ 123 GPa, shocked GGG remains fully transparent to 1550 nm light for at least 250 ns without any signal degradation. Above 135 GPa, PDV data measured through GGG exhibit a gradual loss of fringe contrast following shock entrance, which eventually leads to transparency loss. The duration for which shocked GGG remains transparent decreases with increasing pressure, and at ~ 148 GPa, it becomes opaque within ~ 20–30 ns. This limits the use of GGG as an interferometry window between ~ 110–140 GPa under single shock loading. Within this pressure range, the refractive index of GGG increases linearly with density: n = 1.552 + 0.054ρ. In contrast to single shock loading, where GGG becomes opaque rapidly above ~ 140 GPa, double-shocked GGG remains optically transparent for over 100 ns when it is first shocked to ~ 123 GPa and then reshocked to significantly higher pressures (215–233 GPa). Our findings raise the exciting possibility of GGG being used as a high-impedance optical window in multi-shock and shock-ramp loading experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anthropogenic Aerosols Contribute to the Recent Decline in Precipitation Over the U.S. Southwest

Abstract The winter‐spring precipitation over the Southwestern United States (SWUS) decreased since 1980. It is frequently attributed to Pacific internal decadal variability, but recent studies found anthropogenic aerosols (AA) can also induce a transition to a negative Pacific Decadal Variability (PDV) phase. We revisit the attribution of SWUS drying by quantifying the contributions of anthropogenically forced decadal Pacific Sea Surface Temperatures (SSTs). Applying a low‐frequency component analysis to observations, Community Earth System Model version 2 (CESM2) all‐forcings and single‐forcing large ensembles, we find up to 42% of the observed precipitation trend to be related to the AA‐induced negative PDV‐like pattern, which is driven by the emission shift from the Western to the Eastern Hemisphere. In CESM2, other radiative forcings counteract the influence of AA, but it remains unclear whether the model correctly simulates this balance. This implies that the near‐future trajectories of these forcings, in particular Asian aerosols, are important for projections of SWUS precipitation.

Geology↗

A study of explosive-induced fracture in polymethyl methacrylate (PMMA)

The fracture response of geologic materials is of interest for applications, including geothermal energy harnessing and containment of underground explosions. To better understand the explosively induced fracture response of geomaterials, polymethyl methacrylate (PMMA) was used as a transparent rock surrogate to allow imaging of internal shock propagation and fracture growth processes. Experiments were conducted using high-speed shadowgraphy and photon Doppler velocimetry (PDV), which were compared to numerical simulations. Experiments measured fractures produced in 304.8mm × 304.8mm × 304.8mm PMMA cubes with two simultaneously initiated detonators. The cubes were subjected to varying amounts and directions of externally applied uniaxial stresses, including no stress, 2 MPa stress, and 20 MPa stress. The fracture radius as a function of time was extracted from the high-speed videos. Post-test images of the PMMA cubes aided in the determination of three-dimensional effects not directly imaged by the cameras. The surface velocity history and the shock response captured in PDV and the high-speed videos were compared to the simulated explosive-induced shock response. The simulation results indicate that the shock drives the fracture for the first 20 μs corresponding to a fracture radius of approximately 15 mm in the experiments. The gas-driven fracture extent was estimated analytically using an equilibrium stress distribution calculated after the shock wave propagation through the sample. Reduction in the gas pressure due to the leakage of the explosive products through the crack as a function of time was accounted for. In conclusion, the estimated fracture lengths were in agreement with the experimentally observed fracture lengths.

15 GEOTHERMAL ENERGY↗

HiFiPDV2 v. 2

SAND2024-01061O The HiFiPDV-2 software is similar to other photonic Doppler velocimetry (PDV) analysis codes in that it converts signals from intensity-time space to frequency-time space using a short-time Fourier transform (STFT). It then analyzes peaks of the resulting power spectral density information to extract the velocity-time history. The unique aspects of HiFiPDV and HiFiPDV-2 are that this reduction process is repeated for an array of reasonable STFT input variables. The resulting population distribution of output velocity-time histories is evaluated to determine the most likely velocity history and its associated uncertainty. This uncertainty is defined as the systematic uncertainty of the PDV signal as it is a function of input values to the reduction process. The HiFiPDV-2 program brings new functionality and efficiency to these calculations—most notably significant reductions in memory usage and calculation times, the ability to evaluate frequency-shifted signals, and the ability to filter out baseline signals. Developers recommend that users have at least 2 GB of RAM per CPU core in their system. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Voorhees, Travis↗

Pinwheel Experiment Confirmatory Shot 1 Pre-Shot Report

The purpose of this experimental series is to validate the reactive burn model in the PAGOSA hydrodynamic code. It will also help validate the EOS and Strength models for the aluminum and tantalum cylinders. C4 high explosive (HE) is used to drive an aluminum cylinder into an aluminum sandwiched PBX-9501. The follow-on experiment will drive the aluminum cylinder into a tantalum sandwiched PBX-9501. The experiment will provide time of arrival (TOA) data for the burn front in the HE through the metal cylinders using Fiber Bragg Gratings (FBG). Photon Doppler Velocimetry (PDV) will provide shock wave TOA and the velocity of the inward moving cylinder. The PAGOSA code will be used to predict TOA and cylinder wall velocity using PDV and tracers.

42 ENGINEERING↗

Pinwheel Experiment Tantalum Shot 1 Pre-Shot Report

The purpose of this experimental series is to validate the reactive burn model in the PAGOSA hydrodynamic code. It will also help validate the EOS and Strength models for the aluminum and tantalum cylinders. C4 high explosive (HE) is used to drive an aluminum cylinder into a tantalum sandwiched PBX‐9501. The experiment will provide time of arrival (TOA) data for the burn front in the HE through the metal cylinders using Fiber Bragg Gratings (FBG). Photon Doppler Velocimetry (PDV) will provide shock wave TOA and the velocity of the inward moving cylinder. The PAGOSA code will be used to predict TOA and cylinder wall velocity using PDV and tracers.

36 MATERIALS SCIENCE↗

Photon Doppler Velocimetry to Spatially Resolve Plasma Density in a Power Flow Gap

The understanding of power flow plasmas is important as we look towards next generation pulsed power (NGPP) as current losses could prohibit the goals of that facility. Therefore, it is important to have accurate diagnostics of the plasma parameters on the current machines, which can be used to help inform and improve simulations. Having these plasma parameters will help validate models and simulations to provide confidence when they are expanded to conditions relevant to NGPP. One important plasma parameter that can be measured is the electron density, which can be measured by photonic Doppler velocimetry (PDV). A PDV system has several key advantages over other interferometers by measuring relatively low densities (> 1 × 10 15 cm -2 ) with both spatial and temporal resolution. Experiments were performed on the Mykonos pulsed power machine, which is a 1 MA sub scale machine in which recent platforms have been developed to explore current densities relevant to the inner magnetically insulated transmission line (MITL) on the Z machine. Experiments were performed on two different platforms, the thin foil platform and the Mykonos parallel plate platform (MP3). In addition, a combination of both single-point and multi-point measurements were used. The single-point measurements proved to be very promising, providing a clear increase in density at about 70 ns into the current rise on thin foil experiments up to about 5 × 10 17 cm -3 before the probe stopped providing signal. While we did also see returns from multi-point measurements on both platforms, the signals were not as easy to interpret due to strong background effects. However, they do show initial promise for this diagnostic to measure density at several points across a 1 mm gap. These measurements provide insights in how to improve the diagnostic so that it can provide useful information on power flow relevant experiments.

47 OTHER INSTRUMENTATION↗