Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pathlength”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Verification of Dose Distribution in Carbon Ion Radiation Therapy for Stage I Lung Cancer

Purpose: To evaluate robustness of dose distribution of carbon-ion radiation therapy (C-ion RT) in non-small cell lung cancer (NSCLC) and to identify factors affecting the dose distribution by simulated dose distribution. Methods and Materials: Eighty irradiation fields for delivery of C-ion RT were analyzed in 20 patients with stage I NSCLC. Computed tomography images were obtained twice before treatment initiation. Simulated dose distribution was reconstructed on computed tomography for confirmation under the same settings as actual treatment with respiratory gating and bony structure matching. Dose-volume histogram parameters, such as %D95 (percentage of D95 relative to the prescribed dose), were calculated. Patients with any field for which the %D95 of gross tumor volume (GTV) was below 90% were classified as unacceptable for treatment, and the optimal target margin for such cases was examined. Results: Five patients with a total of 8 fields (10% of total number of fields analyzed) were classified as unacceptable according to %D95 of GTV, although most patients showed no remarkable change in the dose-volume histogram parameters. Receiver operating characteristic curve analysis showed that tumor displacement and change in water-equivalent pathlength were significant predictive factors of unacceptable cases (P<.001 and P=.002, respectively). The main cause of degradation of the dose distribution was tumor displacement in 7 of the 8 unacceptable fields. A 6-mm planning target volume margin ensured a GTV %D95 of >90%, except in 1 extremely unacceptable field. Conclusions: According to this simulation analysis of C-ion RT for stage I NSCLC, a few fields were reported as unacceptable and required resetting of body position and reconfirmation. In addition, tumor displacement and change in water-equivalent pathlength (bone shift and/or chest wall thickness) were identified as factors influencing the robustness of dose distribution. Such uncertainties should be regarded in planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions

Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.

47 OTHER INSTRUMENTATION↗

COSMOLOGICAL EVOLUTION OF ATOMIC GAS AND IMPLICATIONS FOR 21 cm H I ABSORPTION

Galaxy disks are shown to contain a significant population of atomic clouds of 100 pc linear size which are self-opaque in the 21 cm transition. These objects have H I column densities as high as 10{sup 23} cm{sup -2} and contribute to a global opacity correction factor of 1.34 {+-} 0.05 that applies to the integrated 21 cm emission to obtain a total H I mass estimate. High-resolution, opacity-corrected images of the nearest external galaxies have been used to form a robust redshift zero distribution function of H I, f(N{sub HI}, X, z = 0), the probability of encountering a specific H I column density along random lines of sight per unit comoving distance. This is contrasted with previously published determinations of f(N{sub HI}, X) at z = 1 and 3. A systematic decline of moderate column density (18 < log(N{sub H)} < 21) H I is observed with decreasing redshift that corresponds to a decline in surface area of such gas by a factor of five since z = 3. The number of equivalent Damped Lyman Alpha absorbers (log(N{sub HI})>20.3) has also declined systematically over this redshift interval by a similar amount, while the cosmological mass density in such systems has declined by only a factor of two to its current, opacity-corrected value of {Omega}{sup DLA}{sub HI}(z = 0) = 5.4 {+-} 0.9 Multiplication-Sign 10{sup -4}. We utilize the tight but strongly nonlinear dependence of 21 cm absorption opacity on column density at z = 0 to transform our high-resolution H I images into ones of 21 cm absorption opacity. These images are used to calculate distribution and pathlength functions of integrated 21 cm opacity. We suggest that that this z = 0 calibration may also apply at higher redshift. In this case, the incidence of deep 21 cm absorption systems is predicted to show very little evolution with redshift, while that of faint absorbers should decline by a factor of 5 between z = 3 and the present. We explicitly consider the effects of H I absorption against background sources that are extended relative to the 100 pc intervening absorber size scale. Extended background sources result in dramatically altered distribution and pathlength functions which are insensitive to the predicted redshift evolution. Future surveys of 21 cm absorption will require very high angular resolution, of about 15 mas, for their unambiguous interpretation.

79 ASTRONOMY AND ASTROPHYSICS↗

Fugitive methane detection using open-path stand-off chirped laser dispersion spectroscopy

We report an open-path chirped laser dispersion spectrometer capable of detecting the atmospheric methane concentration above the background using both specular and diffusive reflective surfaces via two distinct operation modes in a stand-off detection configuration. The system is integrated with simultaneous ranging functionality, which enables average concentration measurements for varying optical pathlengths. The system was first tested for accuracy and characterized to achieve sensitivity of 2.9 p p m - m / H z 1 / 2 and pathlength precision of 0.2 m / H z 1 / 2 with a controlled release of methane outside the laboratory. The instrument was subsequently field-deployed in the proximity of a natural gas compressor station for fugitive methane detection. The instrument successfully detected methane plumes and narrowed down the location of the plume through multi-path measurement. The field measurements were verified by a co-located reference mobile methane sensor.

Chen, Yifeng↗

A Proposed Beam-Beam Test Facility COMBINE

The COmpact Machine for Beam-beam Interactions in Non-Equilibrium systems (COMBINE) is a proposed, dedicated, beam-beam test facility. This is currently a joint effort between Jefferson Lab and Old Dominion University to create a small, low energy pair of collider rings that would be used to study beam-beam interactions, as well as act as a teaching tool for students. The base design would make use of a pair of identical rings (2.5 meters per side) one rotated 180 degrees from the other, meeting at their common interaction point. These would be fed by an electron gun producing up to 125 keV electrons. The low energy will allow for beam-beam tune shifts commensurate with existing colliders, and will also allow for an exploration of the predicted effects of gear-changing, which would be performed using a variable pathlength scheme. Finally, this machine can also test linac-ring type systems.

Nissen, Edith↗

Computer design of antenna reflectors.

Performance of paraboloidal antenna reflectors is adversely influenced by surface distortions from a perfect paraboloid, which cause pathlength variations of the RF energy beam. The structural design objective for the surface backup structure is to minimize the rms pathlength deviations for gravity loading. Two design approaches are illustrated and applied to sample antenna structure designs. These are a sectional search method and a virtual work/Lagrange multiplier method. Both are shown to provide useful performance improvements. The second, however, appears to be more suited for application to design of large antenna structures.

Levy, R.↗

Effects of random path fluctuations on the accuracy of laser ranging systems

Effects of turbulence-induced pathlength fluctuations on the accuracy of single-color laser ranging systems are examined. Correlation and structure functions for the path deviations are derived using several proposed models for the variation of the turbulence structure parameter with altitude. For single-color systems, random pathlength fluctuations can limit the accuracy of a range measurement to a few centimeters when the turbulence is strong and the effective propagation path is long (greater than 10 km). Two-color systems can partially correct for the random path fluctuations so that in most cases their accuracy is limited to a few millimeters. However, at low elevation angles for satellite ranging (less than 20 deg) and over long horizontal paths, two-color systems can also have errors approaching a few centimeters.

Gardner, C. S.↗

Upper surface blowing aerodynamic and acoustic characteristics

Aerodynamic performance at cruise, and noise effects due to variations in nacelle and wing geometry and mode of operation are studied using small aircraft models that simulate upper surface blowing (USB). At cruise speeds ranging from Mach .50 to Mach .82, the key determinants of drag/thrust penalties are found to be nozzle aspect ratio, boattailing angle, and chordwise position; number of nacelles; and streamlined versus symmetric configuration. Recommendations are made for obtaining favorable cruise configurations. The acoustic studies, which concentrate on the noise created by the jet exhaust flow and its interaction with wing and flap surfaces, isolate several important sources of USB noise, including nozzle shape, exit velocity, and impingement angle; flow pathlength; and flap angle and radius of curvature. Suggestions for lessening noise due to trailing edge flow velocity, flow pathlength, and flow spreading are given, though compromises between some design options may be necessary.

Ryle, D. M., Jr.↗

The propagation of UH-nuclei

A propagation model based on either a leaky box or a slab pathlength distribution and using the currently accepted nuclear parameters has been constructed for the charge range from 26 to 83. The predictions of this model have been examined to identify characteristic features in the observed charge spectrum capable of discriminating between various possible source compositions and different pathlength distributions.

Brewster, N. R.↗

The cosmic ray source composition

The cosmic ray source composition is shown to be related to the observed cosmic ray abundances by a set of linear equations which are valid for either ad hoc pathlength distributions or quantitative solutions to Galactic propagation models. These relations can be used to propagate abundances from the source or to the source, and the method described here allows a simple propagation of abundance uncertainties. A simultaneous analysis of B/C and (21-25)Fe indicates a need for truncation of the pathlength distribution.

Margolis, S. H.↗

High sensitivity detection of trace gases at atmospheric pressure using tunable diode lasers

A detailed study of the detection of trace gases at atmospheric pressure using tunable diode lasers is described. The influence of multipass cells, retroreflectors and topographical targets is examined. The minimum detectable infrared absorption ranges from 0.1 percent for a pathlength of 1.2 km to 0.01 percent over short pathlengths. The factors which limit this sensitivity are discussed, and the techniques are illustrated by monitoring atmospehric CO2 and CH4.

Reid, J.↗

Reanalysis, compatibility and correlation in analysis of modified antenna structures

A simple computational procedure is synthesized to process changes in the microwave-antenna pathlength-error measure when there are changes in the antenna structure model. The procedure employs structural modification reanalysis methods combined with new extensions of correlation analysis to provide the revised rms pathlength error. Mainframe finite-element-method processing of the structure model is required only for the initial unmodified structure, and elementary postprocessor computations develop and deal with the effects of the changes. Several illustrative computational examples are included. The procedure adapts readily to processing spectra of changes for parameter studies or sensitivity analyses.

Levy, R.↗

Stellar Interferometer Tracking experiment - A proposed technology demonstration experiment

A flight experiment entitled the Stellar Interferometer Tracking Experiment (SITE) is described. The objective of the program is to validate the operation of the primary detector of a space-based optical interferometric telescope and to evaluate how isolation, vibration suppression, and pathlength control enable and enhance instrument operation in the disturbance environment of the Shuttle payload bay. The minimum set of hardware that can perform stellar interferometry is described and the need for nanometer pathlength and arcsecond jitter control is shown. The justification for flight, the experimental benefits, and the applications to future space missions are presented. Results of previous ground experiments that demonstrate the required disturbance rejection are reviewed, and initial estimates of open-loop and required closed-loop performance of the flight experiment are presented.

Blackwood, Gary↗

Evolutionary Design of Controlled Structures

Basic physical concepts of structural delay and transmissibility are provided for simple rod and beam structures. Investigations show the sensitivity of these concepts to differing controlled-structures variables, and to rational system modeling effects. An evolutionary controls/structures design method is developed. The basis of the method is an accurate model formulation for dynamic compensator optimization and Genetic Algorithm based updating of sensor/actuator placement and structural attributes. One and three dimensional examples from the literature are used to validate the method. Frequency domain interpretation of these controlled structure systems provide physical insight as to how the objective is optimized and consequently what is important in the objective. Several disturbance rejection type controls-structures systems are optimized for a stellar interferometer spacecraft application. The interferometric designs include closed loop tracking optics. Designs are generated for differing structural aspect ratios, differing disturbance attributes, and differing sensor selections. Physical limitations in achieving performance are given in terms of average system transfer function gains and system phase loss. A spacecraft-like optical interferometry system is investigated experimentally over several different optimized controlled structures configurations. Configurations represent common and not-so-common approaches to mitigating pathlength errors induced by disturbances of two different spectra. Results show that an optimized controlled structure for low frequency broadband disturbances achieves modest performance gains over a mass equivalent regular structure, while an optimized structure for high frequency narrow band disturbances is four times better in terms of root-mean-square pathlength. These results are predictable given the nature of the physical system and the optimization design variables. Fundamental limits on controlled performance are discussed based on the measured and fit average system transfer function gains and system phase loss.

Masters, Brett P.↗

The Fourier-Kelvin Stellar Interferometer a Low Complexity, Low Cost Space Mission for High-Resolution Astronomy and Direct Exoplanet Detection

The Fourier-Kelvin Stellar Interferometer (FKSI) is a mission concept for a spacecraft-borne nulling interferometer for high-resolution astronomy and the direct detection of exoplanets and assay of their environments and atmospheres. FKSI is a high angular resolution system operating in the near to midinfrared spectral region and is a scientific and technological pathfinder to the Darwin and Terrestrial Planet Finder (TPF) missions. The instrument is configured with an optical system consisting, depending on configuration, of two 0.5 - 1.0 m telescopes on a 12.5 - 20 m boom feeding a symmetric, dual Mach- Zehnder beam combiner. We report on progress on our nulling testbed including the design of an optical pathlength null-tracking control system and development of a testing regime for hollow-core fiber waveguides proposed for use in wavefront cleanup. We also report results of integrated simulation studies of the planet detection performance of FKSI and results from an in-depth control system and residual optical pathlength jitter analysis.

Barry, R. K.↗

The Early Planetary Research of Tobias C. Owen

Tobias Chant Owen (Toby) was a graduate student of G. P. Kuiper, receiving his Ph.D. in the Dept. of Astronomy, University of Arizona, in 1965. His thesis was broadly titled "Studies of Planetary Spectra in the Photographic Infrared", and primarily presented a study of the composition and other properties of Jupiter, as well as the abundance and surface pressure of CO2 on Mars. The surface pressure on Mars was a topic of debate at that time, with a wide range of diverse observational results from several investigators. The Jupiter work in particular consisted of the analysis of Kuiper's unpublished spectra that were made with photographic plates pushed to the longest wavelength possible, about 1120 nm, with ammonia-hypersensitized Kodak Z emulsions. Toby used the long-pathlength absorption cells at the Lunar and Planetary Lab to study the spectra of CH4 and NH3 at pressures and temperatures relevant to Jupiter (and Saturn), as well as to search for spectral signatures of potential minor components of their atmospheres. Toby also obtained new spectra of Io, Ganymede, and Saturn and its rings, extended to the long-wavelength limit of photographic emulsions. No new molecular absorptions were found, although Owen basically confirmed Kuiper's earlier result that Saturn's rings are covered (or composed of) with H2O ice or frost. As he pursued a broad range of problems of planetary atmospheres, Toby used existing and newly acquired spectra of the planets in the photographic and near-infrared wavelength regions, together with data he obtained in the laboratory with long-pathlength absorption cells, to resolve some outstanding issues of unidentified spectral features and to clarify issues of the compositions, temperatures, and atmospheric pressures of several bodies. This work laid the foundation for his later decades of studies of planetary atmospheres and comets with spacecraft as an active participant in many US and European missions. He was very influential in shaping the science goals of several missions, and in the interpretation of the results.

Mars↗

Snow Depth from AMSR-2 Using Multispectral Satellite Data in an Artificial Neural Network

By using diffusion theory and Monte Carlo lidar radiative transfer simulations, Hu et al. (2022b) has derived snow depth from the first-, second- and third-order moments of the lidar backscattering pathlength distribution. Lu et al. (2022) calculated the snow depth by applying the methods to the satellite ICESat-2 lidar measurements over the Arctic sea ice, as well as land surfaces of Northern Hemisphere. In this paper, an artificial neural network (ANN) algorithm, employing several channels from Advanced Microwave Scanning Radiometer 2 (AMSR-2) and the humidity vertical profiles from Global Modeling and Assimilation Office (GMAO) Goddard Earth Observing System for Instrument Teams (GEOS-IT) product, is trained to determine snow depth identified by time and geolocation matched 2019 ICESat-2 snow-depth data during winter months over the Arctic sea ice. The trained ANN snow-depth was applied to 2018 AMSR-2 clear pixel data, although the algorithms perform reasonably well in thinner clouds. The validation data (different from the training set) of ANN snow depth from AMSR-2 showed a good agreement with time matched and co-located snow-depth values from ICESat-2. The bias was near zero, with mean absolute error (MAE) 0.05 cm and a root-mean-square-error (RMSE) 0.08 cm. Prior applying the trained ANN snow depth to AMSR-2 data, a cloud screening algorithm was developed with a similar approach. A separate ANN cloud mask was trained to determine an AMSR-2 pixel is clear or cloudy with time and geolocation matched 2015 CALIOP Vertical Feature Mask (VFM) over Arctic sea ice. The ANN cloud mask from AMSR-2 under-estimated cloud fraction by 3-6% compared to CALIOP . The additional research is needed to conclusively evaluate the ANN cloud mask accuracy. Finally, this paper will lay the foundation for a sustained long-term snowfall and snow-storm monitoring system. The future Cloud Aerosol LIdar for Global scale Observations of the ocean-Land Atmosphere system (CALIGOLA) mission will provide a means to calculate snow depth from the lidar backscattering pathlength distribution, benefiting from the UV, visible and infrared pulses. With the calculated snow depth as the truth one could develop a machine learning algorithm, as it was done in this paper, using a passive microwave instrument available at that time to generate a wide range of snow depth data, covering extensive spatial areas in the cross-orbit direction.

Neural Network↗

The Effect of Companions on the SIM Reference Frame

The Space Interferometry Mission (SIM) is a 10-m Michelson space-based optical interferometer designed for precision astrometry (4 microarcseconds, 3 microarcseconds/year) with better accuracy than before over a narrow field of view. One of the primary objectives of the SIM instrument is to determine accurately the directions to a grid of stars, together with their proper motions and parallax, improving a priori knowledge by nearly three orders of magnitude over Hipparcos and one order of magnitude over FAME's planned accuracy (Johnston, 2000). The instrument does not measure directly the angular separation between stars, but rather it measures the projection of each star's direction vector onto the interferometer baseline vector by measuring the pathlength delay of starlight as it passes through the two arms of the interferometer. The accuracy and stability of SIM's celestial reference frame is subject to degradation over the 5-year mission from the reflex motion induced by massive companions of the objects used to construct the celestial reference frame. The authors present the results of simulations that show the sensitivity of reference frame accuracy to companions as a function of mass and period. They assume that pre-launch ground surveys will eliminate all objects with RMS radial velocity greater than 10 m/s. They further assume that the standard astrometric parameters of position, parallax, and proper motion plus acceleration terms in right ascension and declination will be allowed to absorb reflex motion.

ASTROMETRY↗