Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particulate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Particulate contamination spectrometer. Volume 1: Technical report

A laser particulate spectrometer (LPS) system was developed to measure the size and speed distributions of particulate (dusts, aerosols, ice particles, etc.) contaminants. Detection of the particulates was achieved by means of light scattering and extinction effects using a single laser beam to cover a size range of 0.8 to 275 microns diameter and a speed range of 0.2 to 20 meter/second. The LPS system was designed to operate in the high vacuum environment of a space simulation chamber with cold shroud temperatures ranging from 77 to 300 K.

Schmitt, R. J.↗

A laser particulate spectrometer for a space simulation facility

A laser particulate spectrometer (LPS) system was developed to measure the size and speed distributions of particulate contaminants. Detection of the particulates is achieved by means of light scattering and extinction effects using a single laser beam to cover a size range of 0.8 to 275 microns diameter and a speed range of 0.2 to 20 meters/second. The LPS system was designed to operate in the high-vacuum environment of a space simulation chamber with cold shroud temperatures ranging from 77 to 300 K.

Schmitt, R. J.↗

Remote monitoring of environmental particulate pollution - A problem in inversion of first-kind integral equations

The determination of the microstructure, chemical nature, and dynamical evolution of scattering particulates in the atmosphere is considered. A description is given of indirect sampling techniques which can circumvent most of the difficulties associated with direct sampling techniques, taking into account methods based on scattering, extinction, and diffraction of an incident light beam. Approaches for reconstructing the particulate size distribution from the direct and the scattered radiation are discussed. A new method is proposed for determining the chemical composition of the particulates and attention is given to the relevance of methods of solution involving first kind Fredholm integral equations.

Fymat, A. L.↗

Fine particulate capture device

To capture fine particulate matter in a gas such as air, a dielectric fluid is directed to the center of whichever face of a rotating disc is exposed to the air flow. The disc is comprised of two or more segments which bear opposite electrostatic potentials. As the dielectric fluid is centrifuged towards the periphery of the rotating disc, the fluid becomes charged to the same potential as the segment over which it is passing. Particulate matter is attracted to the charged segment and is captured by the fluid. The fluid then carries the captured particulate matter to a collection device such as a toroidal container disposed around the periphery of the disc. A grounded electrically-conductive ring may be disposed at the outer periphery of the disc to neutralize the captured particles and the fluid before they enter the container.

Peterson, V. S.↗

Cometary particulate analyzer

A concept for determining the relative abundance of elements contained in cometary particulates was evaluated. The technique utilizes a short, high intensity burst of laser radiation to vaporize and ionize collected particulate material. Ions extracted from this laser produced plasma are analyzed in a time of flight mass spectrometer to yield an atomic mass spectrum representative of the relative abundance of elements in the particulates. Critical aspects of the development of this system are determining the ionization efficiencies for various atomic species and achieving adequate mass resolution. A technique called energy-time focus, which utilizes static electric fields to alter the length of the ion flight path in proportion to the ion initial energy, was used which results in a corresponding compression to the range of ion flight times which effectively improves the inherent resolution. Sufficient data were acquired to develop preliminary specifications for a flight experiment.

Friichtenicht, J. F.↗

Polar nephelometer for atmospheric particulate studies

A unique polar nephelometer was designed and constructed for the measurement of atmospheric particulate characteristics. The nephelometer produces visible light from a self-contained laser to irradiate an air sample drawn into the instrument. The light scattered from the particulates and molecules in the sample is detected as a function of scattering angle for each of four different incident light polarizations. These measurements are used to determine the particulate scattering matrix which is a function of the size, shape, and index of refraction of the particles. The region of sensitivity for the measurements corresponds to the size range of particles that strongly affects visible radiative transfer in the atmosphere, which is the primary application for the derived information.

Hansen, M. Z.↗

Cometary particulate analyzer design definition study

A concept for remotely determining the relative abundance of elements contained in cometary particulates collected by a spacecraft was conducted with very encouraging results. The technique utilizes a short high intensity burst of laser radiation to vaporize and ionize collected particulate material. Ions extracted from this laser-produced plasma are analyzed in a time of flight mass spectrometer to yield an atomic mass spectrum representative of the relative abundance of elements in the particulates. A prototype analyzer system was designed, constructed, and tested. Results show that: (1) energy-time focus performs as predicted in improving resolution; (2) power densities sufficient to produce usable ionization efficiencies can be obtained; (3) complex alloys such as stainless steel can be analyzed; and (4) a tiny, simple and reliable laser used in the demonstration easily meets spacecraft power and mass limitations. A mass resolution of 150 was experimentally demonstrated at mass 108, and an analytical extrapolation predicts a resolution sufficient to separate masses 250 and 251.

Utterback, N. G.↗

Evaluation of atmospheric particulate concentrations derived from analysis of ratio Thematic Mapper data

An approach for atmospheric particulate concentration evaluation above urban areas using ratio Thematic Mapper (TM) data is discussed. October 25, 1982 TM data over Chicago, IL are analyzed using TM band ratios of 1/2, 1/3, 1/4, 1/5, and 1/6 and particulate concentration estimates derived from TM ratios are tested over low reflective turbid water sites and highly reflective concrete highways. From analysis of the data it is evident that for water, the pattern of increasing particulate concentration is associated with decreasing ratio values in all band combinations used. Over concrete features, the TM band 1/4 ratio values follow the predicted pattern, while the TM band 1/6 has ratios which are reversed from anticipated values.

Carnahan, W. H.↗

A dynamical constraint on particulate sizes for Saturn's B ring spokes

The exponential charge decay time for particulates constituting the spokes in Saturn's B ring is presently proposed as a dynamical time scale for their evolution. Mean particulate radius is determined to be 0.01 + or - 0.03 microns, on the basis of a consideration of solar UV photoemission as the charge decay mechanism which leads to the determination of a dynamical constraint that can be placed on the particulate sizes.

Eplee, Robert E., Jr.↗

Space station particulate contamination environment

The origin of particulate contamination on the Space Station will mostly be from pre-launch operations. The adherence and subsequent release of these particles during space flight are discussed. Particle size, release velocity, and release direction are important in determining particle behavior in the vicinity of the vehicle. The particulate environment at the principal science instrument locations is compared to the space shuttle bay environment. Recommendations for possibly decreasing the particulate contamination are presented.

Miller, E. R.↗

The particulate environment surrounding the space station: Estimates from the PACS data

The objectives of the Particle Analysis Cameras for Shuttle (PACS) experiment (flown on STS-61C) are described and the experiment results are discussed in reference to the expected Space Station environment. Estimates of the sources of particulates surrounding the Space Station were made based on the existing orbital observations data base. Particulates surrounding the shuttle are mostly event related or from the residual release of mass (dust) brought to orbit from the ground. The particulates surrounding the Space Station are likely to arise from additional sources such as operations, docking, erosion, and abrasion. Thus, scaling of the existing data base to long-duration missions in low-Earth orbit requires analysis, modeling, and simulation testing.

Green, Byron David↗

Spacecraft particulate contaminant redistribution

This paper describes analyses that were performed in support of the Hubble Space Telescope (HST)) particulate contamination control effort. The specific problems addressed include extension of available particle removal data to launch acoustic and random vibration conditions, development of an engineering model for transport of suspended particulates by airflow and in the presence of vehicle acceleration, turbulent diffusion, and migration of particulates over vibrating surfaces, and integration of the various models into a code that could be used to generate contamination level estimates for the HST primary mirror and other critical surfaces for the HST mission phases. The overall redistribution calculations were made assuming a specified initial contaminant distribution in terms of MIL STD 1246A levels, and using predicted vibration data for the various HST surfaces and mission phases. As expected, the effects of airflow were found to be significant, particularly for the larger particles. Particles smaller than about 20 microns did not participate appreciably in the redistribution.

Klavins, A.↗

Retrieval of aerosol size distribution moments from multiwavelength particulate extinction measurements

Two methods for inferring aerosol size distribution moments from multiwavelength particulate extinction measurements are studied. The methods are an eigenvalue technique that approximates an appropriate moment-weighting function by a linear combination of kernel functions and a conversion ratio approach that uses the ratio of the particulate extinction measurements at two wavelengths to choose a model moment-to-extinction conversion ratio. The techniques are applied to infer the third moment, or volume, of the aerosol size distribution from actual particulate extinction measurements taken as part of the Stratospheric Aerosol and Gas Experiment II during a correlative measurement experiment in Brazil in April 1985.

Livingston, John M.↗

Effects of dispersed particulates on the rheology of water ice at planetary conditions

Effects of the initial grain size and the hard particulate impurities on the transient and the steady state flows of water ice I were investigated under laboratory conditions selected as appropriate for simulating those of the surfaces and interiors of large moons. The samples were molded with particulate volume fraction, phi, of 0.001 to 0.56 and particle sizes of 1 to 150 microns; deformation experiments were conducted at constant shortening rates of 4.4 x 10 exp -7 to 4.9 x 10 exp -4 per sec at pressures of 50 and 100 MPa and temperatures 77 to 223 K. The results obtained suggest that viscous drag occurs in the ice as it flows around hard particulates. Mixed-phase ice was found to be tougher than pure ice, extending the range of bulk plastic deformation vs. faulting to lower temperatures and higher strain rates. It is suggested that bulk planetary compositions of ice + rock (phi = 0.4-0.5) are roughly 2 orders of magnitude more viscous than pure ice, leading to thermal instability inside giant icy moons and possibly explaining the retention of crater topography on icy planetary surfaces.

Durham, William B.↗

Thermal conductivity measurements of particulate materials under Martian conditions

The mean particle diameter of surficial units on Mars has been approximated by applying thermal inertia determinations from the Mariner 9 Infrared Radiometer and the Viking Infrared Thermal Mapper data together with thermal conductivity measurement. Several studies have used this approximation to characterize surficial units and infer their nature and possible origin. Such interpretations are possible because previous measurements of the thermal conductivity of particulate materials have shown that particle size significantly affects thermal conductivity under martian atmospheric pressures. The transfer of thermal energy due to collisions of gas molecules is the predominant mechanism of thermal conductivity in porous systems for gas pressures above about 0.01 torr. At martian atmospheric pressures the mean free path of the gas molecules becomes greater than the effective distance over which conduction takes place between the particles. Gas particles are then more likely to collide with the solid particles than they are with each other. The average heat transfer distance between particles, which is related to particle size, shape and packing, thus determines how fast heat will flow through a particulate material.The derived one-to-one correspondence of thermal inertia to mean particle diameter implies a certain homogeneity in the materials analyzed. Yet the samples used were often characterized by fairly wide ranges of particle sizes with little information about the possible distribution of sizes within those ranges. Interpretation of thermal inertia data is further limited by the lack of data on other effects on the interparticle spacing relative to particle size, such as particle shape, bimodal or polymodal mixtures of grain sizes and formation of salt cements between grains. To address these limitations and to provide a more comprehensive set of thermal conductivities vs. particle size a linear heat source apparatus, similar to that of Cremers, was assembled to provide a means of measuring the thermal conductivity of particulate samples. In order to concentrate on the dependence of the thermal conductivity on particle size, initial runs will use spherical glass beads that are precision sieved into relatively small size ranges and thoroughly washed.

Presley, M. A.↗

Prediction of particulate contamination on aperture window

This paper presents an analysis to predict the effects of light scattering by surface particles on the sensor window of a missile during ascent flight. The particulate contaminant distribution on the window is calculated by tallying the number of particles in a set of size ranges. The particulate contamination at the end of the mission is predicted by adding the contributions from the events of ground and flight operations. The surface particle redistributions caused by vibroacoustically induced surface acceleration was found to contribute the most of the particulate surface contamination. The analytical surface obscuration calculation with a set of particle counts was compared to the results of image analyzer measurement. The analytical results, which were calculated with a given function of particle shape depending on the size, were more conservative than the measurement. A scattering calculation using a verified BSDF model showed that the scattering was less than 0.001 at 20 off the direction of the incident light in the mid IR wavelength when the surfaces were at Level 300 initially.

Lee, Aleck L.↗

Micromechanics for particulate reinforced composites

A set of micromechanics equations for the analysis of particulate reinforced composites is developed using the mechanics of materials approach. Simplified equations are used to compute homogenized or equivalent thermal and mechanical properties of particulate reinforced composites in terms of the properties of the constituent materials. The microstress equations are also presented here to decompose the applied stresses on the overall composite to the microstresses in the constituent materials. The properties of a 'generic' particulate composite as well as those of a particle reinforced metal matrix composite are predicted and compared with other theories as well as some experimental data. The micromechanics predictions are in excellent agreement with the measured values.

Murthy, Pappu L. N.↗

ICAN/PART: Particulate composite analyzer, user's manual and verification studies

A methodology for predicting the equivalent properties and constituent microstresses for particulate matrix composites, based on the micromechanics approach, is developed. These equations are integrated into a computer code developed to predict the equivalent properties and microstresses of fiber reinforced polymer matrix composites to form a new computer code, ICAN/PART. Details of the flowchart, input and output for ICAN/PART are described, along with examples of the input and output. Only the differences between ICAN/PART and the original ICAN code are described in detail, and the user is assumed to be familiar with the structure and usage of the original ICAN code. Detailed verification studies, utilizing dim dimensional finite element and boundary element analyses, are conducted in order to verify that the micromechanics methodology accurately models the mechanics of particulate matrix composites. ne equivalent properties computed by ICAN/PART fall within bounds established by the finite element and boundary element results. Furthermore, constituent microstresses computed by ICAN/PART agree in average sense with results computed using the finite element method. The verification studies indicate that the micromechanics programmed into ICAN/PART do indeed accurately model the mechanics of particulate matrix composites.

Goldberg, Robert K.↗