At least 55 records · Page 3

A parametric analysis of performance characteristics of satellite-borne multiple-beam antennas

An analytical and empirical model is presented for parametric study of multiple beam antenna frequency reuse capacity and interbeam isolation. Two types of reflector antennas, the axisymmetric parabolic and the offset-parabolic reflectors, are utilized to demonstrate the model. The parameters of the model are introduced and their limitations are discussed in the context of parabolic reflector antennas. The model, however, is not restricted to analysis of reflector antenna performance. Results of the analyses are covered in two tables. The model parameters, objectives, and descriptions are given, multiple-beam antenna frequency reuse capacity and interbeam isolation analysis of the two types of reflectors are discussed as well as future developments of the program model.

Salmasi, A. B.↗

Multi-Variable Parametric Analysis of Prototype Building Energy Performance Using Current and Future Weather Scenarios For Data-Driven Market Transformation Support

This project aimed to develop a public building simulation data set that may be used to inform building code development and guidelines for building innovation. The data set consists of several common building types and many representative locations across the United States. A parametric design of building properties was developed to create a range of building energy models that represent common building design decisions with a particular focus on fenestration options. The US Department of Energy prototype building energy models were altered according to a parametric building design and simulated using both current weather data and future weather estimates derived from global climate models. The resulting data set allows for pertinent exploration of building design parameters, including fenestration, within different environments across the United States in the broader context of climate change.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric Analysis of Entry Vehicles for Giant Planet Missions

The Planetary Science Decadal Survey has identified Uranus and Saturn as high priori-ty destinations for a flagship and New Frontier missions respectively in the decade 2023-2032. The pro-posed presentation will focus on the entry and descent aspects of the entry vehicles design, considered as part of Giant Planet probe mission concepts, and associated trades for viable trajectory options. Giant Planet Entry Vehicle Parametric Study: Launch vehicle capabilities are evolving and provide an opportunity to increase instrumented probe dimensions. To assess the impact of larger aeroshell designs, a parametric study was conducted to understand the impact on aerothermal environments, TPS options, and TPS mass over a range of 1.0m to 2.0m aeroshell diameters for Uranus and Saturn probe concept missions. The 45° sphere-cone geometry is a legacy configuration that has demonstrated static stability and been used successfully in missions to Venus (Pioneer-Venus) and Jupiter (Galileo). A nose radius of 0.4 m was considered primarily to reduce the heat flux at the stagnation point compared to the smaller radii used in the Venus and Jupiter missions. Representative inertial velocities are chosen from a prior NASA Ames study. Viable entry trajectories to meet concept mission and science objectives were developed using the tool POST2. The newly developed thermal protection material called HEEET (Heatshield for Extreme Entry Environment Technology) was considered in the study. This material, which is at a technology readiness level (TRL) of 6, is highly customizable and available in two varieties: (i) a dual-layer version consisting of recession layer on top of an insulative layer, and (ii) a single-layer version consisting of the insulative layer alone, termed 3- dimensional Mid-Density Carbon Phenolic (3MDCP). Both options were considered for the forward heatshield (the sphere-cone part) in the pre-sent study.

Thermal Protection System↗

Parametric Analysis of Aircraft WingWeight Using Low-Order Physics-Based Analysis

In the conceptual aircraft design phase, prediction of the empty weight typically relies on empirically-based regression equations which execute quickly and require little detailed information about the internal structural layout. Since they are based on existing aircraft, however, empirical methods can lose their validity for newer technologies and unconventional configurations. Designers can transition to higher-order, physics-based analysis methods to improve the accuracy of the weight prediction, but at the cost of complex model setup and increased computational time. This paper describes a methodology for low-order aero-structural analysis of conceptual aircraft configurations that increases the use of physics-based analysis in conceptual design, but is less complex and time-consuming than higher-order methods such as finite-element analysis. The methodology uses Vehicle Sketch Pad (OpenVSP) to model the aircraft geometry, and ASWING to perform the aero-structural analysis. The internal forces and moments from the ASWING analysis are post-processed to calculate the resulting direct and shear stresses in the structure, and the thickness distributions of the aircraft components are varied to match the maximum von Mises stress at each cross section to the material allowable. To offset the increased computational time relative to empirical weight equations, a process is studied which uses parametric variation to develop a regression equation relating the weight of the aircraft wing to major design variables. This new weight equation is similar to existing empirical equations, but is built using the more physics-based methodology; the new equation could be used to augment or replace portions of the empirical database to improve the validity of the wing weight prediction for unconventional configurations and advanced technologies.

Olson, Erik D.↗

Parametric analysis of a thermionic space nuclear power system

Key parameters in the design of a thermionic space nuclear power system are identified and analysed in various system tradeoffs. The results are referenced to the thermionic system currently being studied for the SP-100 program. The SP-100 requirements provide definitive guidelines with respect to system optimization, the primary ones being the system mass limit of 3000 kg, the system volume constrraint of one-third of the Space Shuttle cargo bay, and the system lifetime of seven years. Many parametric influences are described and the methods used to optimize system design, in the context of the requirements, are indicated. Considerable design flexiblity is demonstrated.

Strohmayer, W. H.↗

Numerical model of solar dynamic radiator for parametric analysis

Growth power requirements for Space Station Freedom will be met through addition of 25 kW solar dynamic (SD) power modules. The SD module rejects waste heat from the power conversion cycle to space through a pumped-loop, multi-panel, deployable radiator. The baseline radiator configuration was defined during the Space Station conceptual design phase and is a function of the state point and heat rejection requirements of the power conversion unit. Requirements determined by the overall station design such as mass, system redundancy, micrometeoroid and space debris impact survivability, launch packaging, costs, and thermal and structural interaction with other station components have also been design drivers for the radiator configuration. Extensive thermal and power cycle modeling capabilities have been developed which are powerful tools in Station design and analysis, but which prove cumbersome and costly for simple component preliminary design studies. In order to aid in refining the SD radiator to the mature design stage, a simple and flexible numerical model was developed. The model simulates heat transfer and fluid flow performance of the radiator and calculates area mass and impact survivability for many combinations of flow tube and panel configurations, fluid and material properties, and environmental and cycle variations. A brief description and discussion of the numerical model, it's capabilities and limitations, and results of the parametric studies performed is presented.

Rhatigan, Jennifer L.↗

Parametric study of prospective early commercial MHD power plants (PSPEC). General Electric Company, task 1: Parametric analysis

The performance and cost of moderate technology coal-fired open cycle MHD/steam power plant designs which can be expected to require a shorter development time and have a lower development cost than previously considered mature OCMHD/steam plants were determined. Three base cases were considered: an indirectly-fired high temperature air heater (HTAH) subsystem delivering air at 2700 F, fired by a state of the art atmospheric pressure gasifier, and the HTAH subsystem was deleted and oxygen enrichment was used to obtain requisite MHD combustion temperature. Coal pile to bus bar efficiencies in ease case 1 ranged from 41.4% to 42.9%, and cost of electricity (COE) was highest of the three base cases. For base case 2 the efficiency range was 42.0% to 45.6%, and COE was lowest. For base case 3 the efficiency range was 42.9% to 44.4%, and COE was intermediate. The best parametric cases in bases cases 2 and 3 are recommended for conceptual design. Eventual choice between these approaches is dependent on further evaluation of the tradeoffs among HTAH development risk, O2 plant integration, and further refinements of comparative costs.

Marston, C. H.↗

Thermodynamic parametric analysis of refueling heavy-duty hydrogen fuel-cell electric vehicles

Reliable design and safe operation of heavy-duty hydrogen refueling stations are essential for the successful deployment of heavy-duty fuel cell electric vehicles (FCEVs). Fueling heavy-duty FCEVs is different from light-duty vehicles in terms of the dispensed hydrogen quantities and fueling rates, requiring tailored fueling station design for each vehicle class. In particular, the selection and design of the onboard hydrogen storage tank system and the fueling performance requirements influence the safe design of hydrogen fueling stations. A thermodynamic modeling and analysis are performed to evaluate the impact of various fueling parameters and boundary conditions on the fueling performance of heavy-duty FCEVs. Here, we studied the effect of dispenser pressure ramp rate and precooling temperature, initial tank temperature and pressure, ambient temperature, and onboard storage design parameters, such as onboard storage pipe diameter and length, on the fueling rate and final vehicle state-of-charge, while observing prescribed tank pressure and temperature safety limits. An important finding was the sensitivity of the temporal fueling rate profile and the final tank state of charge to the design factors impacting pressure drop between the dispenser and vehicle tank, including onboard storage pipe diameter selection, and flow coefficients of nozzle, valves, and fittings. The fueling rate profile impacts the design and cost of the hydrogen precooling unit upstream of the dispenser.

08 HYDROGEN↗

Parametric analysis on optimized design of hybrid solar power plants

There is increasing interest in utility-scale solar power plants with storage which can flexibly dispatch renewable energy to the grid. However, plant design possesses many degrees of freedom and non-obvious trade-offs in performance. Software tools can estimate or optimize the performance of a specific plant configuration under market and weather conditions of interest; the associated cost parameters and operating assumptions strongly influence estimates of plant performance and decisions regarding optimal sizing. We employ the National Renewable Energy Laboratory's Hybrid Optimization and Performance Platform, which incorporates optimal dispatch when evaluating plant performance, and investigate the sensitivity to weather and market conditions, operating limitations, and the presence of a capacity-based incentive. We demonstrate changes in plant performance and optimal sizing with respect to these inputs and discuss implications. Here results show that PV-with-battery designs are more profitable under our assumptions, but that designs including a concentrated solar power (CSP) system produce significantly greater annual energy; and that CSP-with-thermal energy storage designs maximizing the benefit-to-cost ratio have an input-dependent linear relationship between the CSP field solar multiple and the hours of storage as the project budget varies.

14 SOLAR ENERGY↗

A Novel Framework for Parametric Analysis of Coastal Transition Zone Modeling

Abstract Vulnerability of coastal regions to extreme events motivates an operational coupled inland‐coastal modeling strategy focusing on the coastal transition zone (CTZ), an area between the coast and upland river. To tackle this challenge, we propose a top‐down framework for investigating the contribution of different processes to the hydrodynamics of CTZs with various geometrical shapes, different physical properties, and under several forcing conditions. We further propose a novel method, called tidal vanishing point (TVP), for delineating the extent of CTZs through the upland. We demonstrate the applicability of our framework over the United States East and Gulf coasts. We categorize CTZs in the region into three classes, namely, without estuary (direct river–coast connection), triangular‐, and trapezoidal‐shaped estuary. The results show that although semidiurnal tidal constituents are dominant in most cases, diurnal tidal constituents become more prevalent in the river segment as the discharge increases. Also, decreasing the bed roughness value promotes more significant changes in the results than increasing it by the same value. Additionally, the estuary promotes tidal energy attenuation and consequently decreases the reach of tidal signals through the upland. The proposed framework is generic and extensible to any coastal region.

Chegini, Taher↗

A parametric analysis of oilfield design factors affecting the detectability and characterization of electrically conductive hydrofracks

Electrical responses in the vicinity of energized steel-cased well sources offer significant potential for monitoring induced fractures. However, the high complexity of well-fracture-host models spanning multiple length scales compels analysts to simplify their numerical models due to enormous computational costs. This consequently limits our understanding regarding monitoring capabilities and the limitations of electrical measurements on realistic hydraulically fracturing systems. In this paper, we use the hierarchical finite element approach to construct geoelectric models in which geometrically complex fractures and steel-cased wells are discretely represented in 3D conducting media without sacrificing the model realism and computation efficiency. We have discovered systematic numerical analyses of the electrical responses to evaluate the influences of borehole material conductivity and the source type as well as the effects of well geometry, conductivity contrast, source location, fracture growth, and fracture propagation. Furthermore, the numerical results indicate that the borehole material property has a strong control on the electrical potentials along the production and monitoring wells. The monopole source located at a steel-cased well results in a current density distribution that decays away from the source location throughout the well length, whereas the dipole source produces a current density that dominates mainly along the dipole length. Moreover, the conductivity contrast between the fractures and host does not change the overall pattern of the electrical potentials but varies its amplitude. The fracture models near different well systems indicate that the well geometry controls the entire distribution of potentials, while the characteristics of the voltage difference profiles along the wells before and after fracturing are insensitive to the well geometry and the well in which the source is located. Further, the hydraulic-fracturing models indicate that the voltage differences along the production well before and after fracturing have strong sensitivity to fracture growth and fracture set propagation.

58 GEOSCIENCES↗