Parametric amplifiers. Citations from the Engineering Index data base
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Here we report on measurements made with an improved CO2 Sounder lidar during the ASCENDS 2014 and 2016 airborne campaigns. The changes made to the 2011 version of the lidar included incorporating a rapidly wavelength-tunable, step-locked seed laser in the transmittter, using a much more sensitive HgCdTe APD detector andusing an analog digitizer with faster readout time in the receiver. We also improved the lidar's calibration approach and the XCO2 retrieval algorithm. The 2014 and 2016 flights were made over several types of topographic surfaces from3 to 12 km aircraft altitudes in the continental US. The results are compared to the XCO2 values computed from an airborne in situ sensor during spiral-down maneuvers. The 2014 results show significantly better performance and include measurement of horizontal gradients in XCO2 made over the Midwestern US that agree with chemistry transport models. The results from the 2016 airborne lidar retrievals show precisions of 0:7 parts per million (ppm) with 1 s averaging over desert surfaces, which is an improvement of about 8 times compared to similar measurements made in 2011. Measurements in 2016 were also made over fresh snow surfaces that have lower surface reflectance at the laser wavelengths. The results from both campaigns showed that the mean values of XCO2 retrieved from the lidar consistently agreed with those based on the in situ sensor to within 1 ppm. The improved precision and accuracy demonstrated in the 2014 and 2016 flights should benefit future airborne science ampaigns and advance the technique's readiness for a spacebased instrument.
UNKNOWN
No abstract provided
Optical parametric amplifiers require a seed energy at the spectral range of interest for amplification. In the case of pulsed laser systems, seed pulse characteristics such as spectral energy density and spectral uniformity influence laser system design and performance. In this letter, we present the design and modeling of a few micro-joules, wavelength-tunable, femtosecond parametric amplifier system. We employ a gain-managed nonlinear fiber amplifier output as the seed pulse. This seed pulse is relatively uniform across its bandwidth from 1010 to 1180 nm. Its spectral energy density averages 600 pJ/nm, 30 times higher than conventional counterparts. The overall amplification gain is 175, and the conversion efficiency is 17.5%. The inherent quasi-linear chirp of the seed pulse is utilized to alter the output wavelength. Our tunable femtosecond laser is an enabling technology for high-demand applications such as time-resolved spectroscopy, nonlinear and advanced material research, and biomedical imaging and microscopy modalities.
A computer program for parametric amplifier design is developed with special emphasis on practical design considerations for microwave integrated circuit degenerate amplifiers. Precision measurement techniques are developed to obtain a more realistic varactor equivalent circuit. The existing theory of a parametric amplifier is modified to include the equivalent circuit, and microwave properties, such as loss characteristics and circuit discontinuities are investigated.
Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. At NASA Goddard Space Flight Center (GSFC) we have been developing a laser-based technology needed to remotely measure CH4 from orbit. We report on our development effort for the methane lidar, especially on our laser transmitters and recent airborne demonstration. Our lidar transmitter is based on an optical parametric process to generate near infrared laser radiation at 1651 nanometers, coincident with a CH4 absorption. In an airborne flight campaign in the fall of 2015, we tested two kinds of laser transmitters --- an optical parametric amplifier (OPA) and an optical parametric oscillator (OPO). The output wavelength of the lasers was rapidly tuned over the CH4 absorption by tuning the seed laser to sample the CH4 absorption line at several wavelengths. This approach uses the same Integrated Path Differential Absorption (IPDA) technique we have used for our CO2 lidar for ASCENDS. The two laser transmitters were successfully operated in the NASAs DC-8 aircraft, measuring methane from 3 to 13 kilometers with high precision.
Average power effects relative to the operation of parametric oscillators and amplifiers have been calculated. Temperature gradients have been calculated for both radial and longitudinal heat extraction. In many instances, the thermal load on a parametric oscillator is higher than the thermal load on a parametric amplifier with the same pump power. Having one or both these wavelengths resonant increases the chances that a generated photon will be absorbed by the nonlinear crystal. Temperature profiles and thermal diffusion time constants have been calculated for Gaussian beams, given the heat-deposition rate. With radical heat extraction the temperature profile can be expressed in a power series or approximated by a Gaussian distribution function.
Radio emission measurements of moon using modulation radiometer with parametric amplifier
Field effect transistor and parametric amplifier characteristics, and bolometer fabrication for advanced astronomical infrared detectors
A 961-Mc lower-sideband up-converter was specially designed to serve as preamplifier for the satellite-tracking radar used in Project Echo. The amplifier and its power supply are separately boxed and are installed directly behind the tracking antenna. The amplifier has been functioning most satisfactorily and has been used in routine manner to track the Echo satellite from horizon to horizon. This paper describes the design considerations, and details the special steps taken to ensure that the amplifier met the particular system needs of low noise, absolute stability, insensitivity to temperature fluctuations, and high input-power level before the onset of gain compression. The satisfactory operation of this amplifier confirms the great potentiality of parametric amplifiers as stable, low-noise, high-frequency receivers.
Direct current parametric amplifier for very low voltages - description and circuit applications
Parametric amplifier and maser used to provide low-noise receivers in a space communication system
Three construction techniques reduce noise temperature of microwave parametric amplifier. Techniques include electroformed idler cavity, screw-tuned idler, and low-loss matching section.
Parametric amplifiers and tunnel diodes as L-band and S-band down-converters - frequency division multiplexing
Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas, with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. Yet, lack of understanding of the processes that control CH4 sources and sinks and its potential release from stored carbon reservoirs contributes significant uncertainty to our knowledge of the interaction between carbon cycle and climate change. At Goddard Space Flight Center (GSFC) we have been developing the technology needed to remotely measure CH4 from orbit. Our concept for a CH4 lidar is a nadir viewing instrument that uses the strong laser echoes from the Earth's surface to measure CH4. The instrument uses a tunable, narrow-frequency light source and photon-sensitive detector to make continuous measurements from orbit, in sunlight and darkness, at all latitudes and can be relatively immune to errors introduced by scattering from clouds and aerosols. Our measurement technique uses Integrated Path Differential Absorption (IPDA), which measures the absorption of laser pulses by a trace gas when tuned to a wavelength coincident with an absorption line. We have already demonstrated ground-based and airborne CH4 detection using Optical Parametric Amplifiers (OPA) at 1651 nm using a laser with approximately 10 microJ/pulse at 5kHz with a narrow linewidth. Next, we will upgrade our OPO system to add several more wavelengths in preparation for our September 2015 airborne campaign, and expect that these upgrades will enable CH4 measurements with 1% precision (10-20 ppb).