Flexible radiator system: Executive summary

A full scale prototype flexible radiator panel was designed, built and tested. The panel, has approximately 173 sq ft of radiating area and is designed to reject 1.33 kW of heat to a 0 F sink with a 100 F fluid inlet. The panel is constructed from a flexible Teflon/silver mesh fin surrounding 1/8 inch Teflon tubes. The prototype panel is stowed on a 10 inch diameter by 4 foot wide drum. (It rolls up to a diameter of 17 inches when fully stowed). Deployment of the soft tube prototype is via two four inch diameter Kevlar/Mylar inflation tubes with flat springs incorporated in each tube. Nitrogen is normally used for the deployment with approximately 1 psi required. The springs retract the panels when the inflation tubes are deflated. Another method of deployment available for the soft tube flexible is a motor driven deployable boom. This eliminates the need for expendables when the panel area is varied during the mission for heat load control. The soft tube panel is designed for a 90% probability of no punctured tube in a 30 day mission. The acceptable working fluids for this soft tube flexible are Coolanol 15, Coolanol 20 and Glycol/water (a eutectic mixture).

Oren, J. R.↗

Structural and Acoustic Numerical Modeling of a Curved Composite Honeycomb Panel

The finite and boundary element modeling of the curved section of a composite honeycomb aircraft fuselage sidewall was validated for both structural response and acoustic radiation. The curved panel was modeled in the pre-processor MSC/PATRAN. Geometry models of the curved panel were constructed based on the physical dimensions of the test article. Material properties were obtained from the panel manufacturer. Finite element models were developed to predict the modal parameters for free and supported panel boundary conditions up to a frequency of 600 Hz. Free boundary conditions were simulated by providing soft foam support under the four comers of the panel or by suspending the panel from elastic bands. Supported boundary conditions were obtained by clamping the panel between plastic tubing seated in grooves along the perimeter of a stiff and heavy frame. The frame was installed in the transmission loss window of the Structural Acoustic Loads and Transmission (SALT) facility at NASA Langley Research Center. The structural response of the curved panel due to point force excitation was predicted using MSC/NASTRAN and the radiated sound was computed with COMET/Acoustics. The predictions were compared with the results from experimental modal surveys and forced response tests on the fuselage panel. The finite element models were refined and updated to provide optimum comparison with the measured modal data. Excellent agreement was obtained between the numerical and experimental modal data for the free as well as for the supported boundary conditions. Frequency response functions (FRF) were computed relating the input force excitation at one panel location to the surface acceleration response at five panel locations. Frequency response functions were measured at the same locations on the test specimen and were compared with the calculated FRF values. Good agreement was obtained for the real and imaginary parts of the transfer functions when modal participation was allowed up to 3000 Hz. The validated finite element model was used to predict the surface velocities due to the point force excitation. Good agreement was obtained between the spatial characteristics of the predicted and measured surface velocities. The measured velocity data were input into the acoustic boundary element code to compute the sound radiated by the panel. The predicted sound pressure levels in the far-field of the panel agreed well with the sound pressure levels measured at the same location.

Grosveld, Ferdinand W.↗

Fatigue-Crack Propagation in Aluminum-Alloy Tension Panels

Results are presented of a series of fatigue tests to study crack propagation and the resulting stress distributions in tension panels. The panels were all of the same general design, and configurations varied mainly in the relative amount of cross-sectional area in the skin, stiffeners, and flanges. The panels were constructed of 2024-T3 and 7075-T6 aluminum alloys. It was found that the average rate of crack growth was slower in panels made of 2024-T3 aluminum alloy than in panels made of 7075-T6 aluminum alloy. All cracks initiated in the skin, and the slowest crack growth was measured in configurations where the highest percentage of cross-sectional area was in the stiffeners. Strain-gage surveys were made to determine the redistribution of stress as the crack grew across the panels. As a crack approached a given point in the skin, the stress at that point increased rapidly. The stress in the stiffeners also increased as the crack approached the stiffeners. During the propagation of the crack the stress was not distributed uniformly in the remaining area.

Whaley, Richard E.↗

Compression Response of a Sandwich Fuselage Keel Panel With and Without Damage

Results are presented from an experimental and analytical study of a sandwich fuselage keel panel with and without damage. The fuselage keel panel is constructed of graphite-epoxy skins bonded to a honeycomb core, and is representative of a highly loaded fuselage keel structure. The face sheets of the panel contain several terminated or dropped plies along the length of the panel. The results presented provide a better understanding of the load distribution in damaged and undamaged thick-face-sheet composite sandwich structure with dropped plies and of the failure mechanisms of such structure in the presence of low-speed impact damage and discrete-source damage. The impact-damage condition studied corresponds to barely visible impact damage (BVID), and the discrete-source damage condition studied is a notch machined through both face sheets. Results are presented from an impact-damage screening study conducted on another panel of the same design to determine the impact energy necessary to inflict BVID on the panel. Results are presented from compression tests of the panel in three conditions: undamaged; BVID in two locations; and BVID in two locations and a notch through both face sheets. Surface strains in the face sheets of the undamaged panel and the notched panel obtained experimentally are compared with finite element analysis results. The experimental and analytical results suggest that for the damage conditions studied, discrete-source damage influences the structural performance more than BVID.

McGowan, David M.↗

Vibroacoustic Model Validation for a Curved Honeycomb Composite Panel

Finite element and boundary element models are developed to investigate the vibroacoustic response of a curved honeycomb composite sidewall panel. Results from vibroacoustic tests conducted in the NASA Langley Structural Acoustic Loads and Transmission facility are used to validate the numerical predictions. The sidewall panel is constructed from a flexible honeycomb core sandwiched between carbon fiber reinforced composite laminate face sheets. This type of construction is being used in the development of an all-composite aircraft fuselage. In contrast to conventional rib-stiffened aircraft fuselage structures, the composite panel has nominally uniform thickness resulting in a uniform distribution of mass and stiffness. Due to differences in the mass and stiffness distribution, the noise transmission mechanisms for the composite panel are expected to be substantially different from those of a conventional rib-stiffened structure. The development of accurate vibroacoustic models will aide in the understanding of the dominant noise transmission mechanisms and enable optimization studies to be performed that will determine the most beneficial noise control treatments. Finite element and boundary element models of the sidewall panel are described. Vibroacoustic response predictions are presented for forced vibration input and the results are compared with experimental data.

Buehrle, Ralph D.↗

Experimental test of plant canopy reflectance models on cotton

Spectroradiometric data on the bidirectional reflectance function was collected for a cotton canopy as a function of observer zenith angle, observer angle, and solar zenith angle. The area under study was about 40 miles from the Gulf of Mexico and the prevailing winds blew inland such that cloud formation increased during the day. The standard reflectance panel was constructed of plywood that had been spray painted with a flat white latex paint. Physical and optical plant parameters were measured. A time lapse mechanism was constructed to operate a 16 mm movie camera such that single frames could be exposed at intervals of one per second up to one per hour. Data were digitized from a strip chart recorder and reflectance panel measurements.

Lemaster, E. W.↗

Experimental Evaluation of Tuned Chamber Core Panels for Payload Fairing Noise Control

Analytical models have been developed to predict the sound absorption and sound transmission loss of tuned chamber core panels. The panels are constructed of two facesheets sandwiching a corrugated core. When ports are introduced through one facesheet, the long chambers within the core can be used as an array of low-frequency acoustic resonators. To evaluate the accuracy of the analytical models, absorption and sound transmission loss tests were performed on flat panels. Measurements show that the acoustic resonators embedded in the panels improve both the absorption and transmission loss of the sandwich structure at frequencies near the natural frequency of the resonators. Analytical predictions for absorption closely match measured data. However, transmission loss predictions miss important features observed in the measurements. This suggests that higher-fidelity analytical or numerical models will be needed to supplement transmission loss predictions in the future.

Schiller, Noah H.↗

Segmented Solid Surface Reflector Concentrically Stacked With Tubular Shape Memory Composite Hinges

A new architecture for solid surface reflector antennas scalable to sizes greater than 10 m is presented. The design uses compact, light, and simple advanced deployable structures to create sub-reflectors that can be assembled in space into larger units using a robotic arm. The seven-panel hexagonal sub-reflector is divided into hexagonal panels that stack concentrically and vertically. The central panel is connected to each side panel on the back side by a pair of tubular shape memory composite hinges that enable the required deployment kinematics with controlled dynamics. A secondary mechanism closes the interpanel gap. The focus of the paper is on the development of the sub-reflector elements, namely the tubular hinges that use embedded heaters and sensors for triggering and control, the actuation mechanisms, and the lightweight sandwich construction reflector panels. A parametric study using finite element analyses was conducted to assess how design features of the hinge affect its stowage and deployment dynamics. The preliminary component fabrication and testing results for the two-panel assembly breadboard model are outlined. Finally, the results of the test campaign with the brassboard reflector model are presented. A comparison of deployed reflector surface deviation between the measured surface after the stowage and deployment process and the pre-test scans and the nominal surface revealed root mean square errors of less than 1 mm, as required by X-band radiofrequency transmission.

gravity offloading↗

Segmented Hexagonal Antenna Reflector Concentrically Stacked Using Shape Memory Composite Tubular Hinges

A new architecture for solid surface reflector antennas scalable to sizes greater than 10 m is presented. The design uses compact, light, and simple advanced deployable structures to create sub-reflectors that can be assembled in space into larger units using a robotic arm. The seven-panel hexagonal sub-reflector is divided into hexagonal panels that stack concentrically and vertically. The central panel is connected to each side panel on the back side by a pair of tubular shape memory composite hinges that enable the required deployment kinematics with controlled dynamics. A secondary mechanism closes the interpanel gap. The focus of the paper is on the development of the sub-reflector elements, namely the tubular hinges that use embedded heaters and sensors for triggering and control, the actuation mechanisms, and the lightweight sandwich construction reflector panels. A parametric study using finite element analyses was conducted to assess how design features of the hinge affect its stowage and deployment dynamics. The preliminary component fabrication and testing results for the two-panel assembly breadboard model are outlined. Finally, the results of the test campaign with the brassboard reflector model are presented. A comparison of deployed reflector surface deviation between the measured surface after the stowage and deployment process and the pre-test scans and the nominal surface revealed root mean square errors of less than 1 mm, as required by X-band radiofrequency transmission.

gravity offloading methods↗

Dynamics Impact Tolerance of Shuttle RCC Leading Edge Panels Using LS-DYNA

This paper describes a research program conducted to enable accurate prediction of the impact tolerance of the shuttle Orbiter leading-edge wing panels using physics-based codes such as LS-DYNA, a nonlinear, explicit transient dynamic finite element code. The shuttle leading-edge panels are constructed of Reinforced-Carbon-Carbon (RCC) composite material, which is used because of its thermal properties to protect the shuttle during reentry into the Earth's atmosphere. Accurate predictions of impact damage from insulating foam and other debris strikes that occur during launch required materials characterization of expected debris, including strain-rate effects. First, analytical models of individual foam and RCC materials were validated. Next, analytical models of foam cylinders impacting 6- in. x 6-in. RCC flat plates were developed and validated. LS-DYNA pre-test models of the RCC flat plate specimens established the impact velocity of the test for three damage levels: no-detectable damage, non-destructive evaluation (NDE) detectable damage, or visible damage such as a through crack or hole. Finally, the threshold of impact damage for RCC on representative Orbiter wing panels was predicted for both a small through crack and for NDE-detectable damage.

Fasanella, Edwin L.↗

Dynamic Impact Tolerance of Shuttle RCC Leading Edge Panels using LS-DYNA

This paper describes a research program conducted to enable accurate prediction of the impact tolerance of the shuttle Orbiter leading-edge wing panels using 'physics-based- codes such as LS-DYNA, a nonlinear, explicit transient dynamic finite element code. The shuttle leading-edge panels are constructed of Reinforced-Carbon-Carbon (RCC) composite material, which issued because of its thermal properties to protect the shuttle during re-entry into the Earth's atmosphere. Accurate predictions of impact damage from insulating foam and other debris strikes that occur during launch required materials characterization of expected debris, including strain-rate effects. First, analytical models of individual foam and RCC materials were validated. Next, analytical models of individual foam cylinders impacting 6-in. x 6-in. RCC flat plates were developed and validated. LS-DYNA pre-test models of the RCC flat plate specimens established the impact velocity of the test for three damage levels: no-detectable damage, non-destructive evaluation (NDE) detectable damage, or visible damage such as a through crack or hole. Finally, the threshold of impact damage for RCC on representative Orbiter wing panels was predicted for both a small through crack and for NDE-detectable damage.

Fasanella, Edwin↗

Lightweight graphite/polyimide panels

Panels are constructed of honeycombed polyimide/graphite core covered with thin face sheet of same material. Fabrication is based on extension of thin-gage graphite technology and modification of glass filament polyimide honeycomb techniques.

Poesch, J. G.↗

Improved bonding of honeycomb panels

Technique, using angular metal braces bonded onto panels, lowers construction costs. Technique improves overall structural strength, decreases assembly time, and avoids wear points created by bolts and rivets.

Sobkiewicz, S. A.↗

Investigation of fuselage acoustic treatment for a twin-engine turboprop aircraft in flight and laboratory tests

A flight and laboratory study of sidewall acoustic treatment for cabin noise control is described. In flight, cabin noise levels were measured at six locations with three treatment configurations. Noise levels from narrow-band analysis are reduced to one-third octave format and used to calculate insertion loss, IL, defined as the reduction of interior noise associated with the addition of a treatment. Laboratory tests used a specially constructed structural panel modeled after the propeller plane section of the aircraft sidewall, and acoustic treatments representing those used in flight. Lab measured transmission loss and absorption values were combined using classical acoustic procedures to obtain a prediction of IL. Comparison with IL values measured in flight for the boundary layer component of the noise indicated general agreement.

Mixson, J. S.↗

Field-incidence noise transmission loss of general aviation aircraft double wall configurations

Theoretical formulations have been developed to describe the transmission of reverberant sound through an infinite, semi-infinite and a finite double panel structure. The model incorporates the fundamental resonance frequencies of each of the panels, the mass-air-mass resonances of the structure, the standing wave resonances in the cavity between the panels and finally the coincidence resonance regions, where the exciting sound pressure wave and flexural waves of each of the panels coincide. It is shown that phase cancellation effects of pressure waves reflected from the cavity boundaries back into the cavity allows the transmission loss of a finite double panel structure to be approximated by a finite double panel mounted in an infinite baffle having no cavity boundaries. Comparison of the theory with high quality transmission loss data yields good agreement in the mass-controlled frequency region. It is shown that the application of acoustic blankets to the double panel structure does not eliminate the mass-air-mass resonances if those occur at low frequencies. It is concluded that this frequency region of low noise transmission loss is a potential interior noise problem area for propeller driven aircraft having a double panel fuselage construction.

Grosveld, F. W.↗

Measurements of the response of transport aircraft ceiling panels to fuel pool fires

Tests were performed to characterize the responses of various aircraft ceiling panel configurations to a simulated post-crash fire. Attention was given to one currently used and four new ceiling configurations exposed to a fuel pool fire in a circulated air enclosure. The tests were controlled to accurately represent conditions in a real fire. The panels were constructed of fiberglass-epoxy, graphite-phenolic resin, fiberglass-phenolic resin, Kevlar-epoxy, and Kevlar-phenolic resin materials. The phenolic resin-backed sheets performed the best under the circumstances, except when combined with Kevlar, which became porous when charred.

Bankston, C. P.↗

EAGLEView: A surface and grid generation program and its data management

An old and proven grid generation code, the EAGLE grid generation package, is given an added dimension of a graphical interface and a real time data base manager. The Numerical Aerodynamic Simulation (NAS) Panel Library is used for the graphical user interface. Through the panels, EAGLEView constructs the EAGLE script command and sends it to EAGLE to be processed. After the object is created, the script is saved in a mini-buffer which can be edited and/or saved and reinterpreted. The graphical objects are set-up in a linked-list and can be selected or queried by pointing and clicking the mouse. The added graphical enhancement to the EAGLE system emphasizes the unique capability to construct field points around complex geometry and visualize the construction every step of the way.